Santa Fe KF-P32 Installation instructions

1
Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions
Serial Number
Install Date
Sold By
Installation & Operation Instructions
The Santa Fe Air Puri,er utilizes HEPA-grade
!ltration and UV sterilization capability to clean
your air while also being quieter than a whisper.
SANTA FE | AIR PURIFIER
08/21 Rev A
Santa-Fe-Products.com | 800.533.7533

2Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com
Thank you for purchasing the innovative KF-P32 air puriÄer! Follow all safety precautions to ensure proper operation
of the device. These instructions describe the safety precautions to be observed during operation. They are designed
to prevent injuries or damage to this device.
•Our air puri'er operates on 120V, 60Hz.
•Unplug the unit before cleaning or maintenance. Cleaning the unit, while it is plugged in may
result in electric shock, electric spark, and serious injury.
•This air puri'er contains a UV-C emitter.
•Unintended use of the air puri'er or damage to the housing may result in the escape of
dangerous UV-C radiation. UV-C radiation may, even with minimum exposure, cause harm
to the eyes and skin.
•Do not operate air puri'ers that are clearly damaged.
•The device should be cleaned every two months. Although in high use situations the unit
may need to be cleaned every 2-4 weeks. Before cleaning, unplug the device. To clean the
device, open the back cover, remove the 'lter, and wipe the interior of the device with a wet
towel.
•If the UV light is damaged, it must be replaced by the manufacturer, a service agent, or
similarly quali'ed persons to avoid a hazard.
•The air puri'er is not to be used by persons (including children) with reduced physical,
sensory, or mental capabilities, or lack of experience and knowledge, unless they have been
given instruction or are supervised.
•This air puri'er can be used by children aged 8 years and above and persons with reduced
physical, sensory, or mental capabilities or lack of experience and knowledge if they are
supervised or receiving instruction on use of the air puri'er from an adult. Children should
not play with the air puri'er. Cleaning and user maintenance should not be completed by
children without supervision.
•Children should be supervised when product is in used. Do not allow children to play on or
near the air puri'er. Keep children’s hair, loose clothing, and body parts away from/out of
the intake grille, bents, holes, or openings.
•Do not handle the unit with wet hands. Thoroughly dry your hands before handling any part
of the air puri'er.
•Hair, loose clothing, and body parts away from openings and moving parts. Hair, loose
clothing, and body parts can get caught in the air puri'er resulting in injury.
S A F E T Y P RE CA UT IONS
CA UT ION!
REMOVE THE FILTER FROM THE PLASTIC BEFORE USING THE AIR PURIFIER.
WA RNING!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY, READ AND UNDERSTAND
THIS GUIDE BEFORE OPERATING THIS AIR PURIFIER.

3
Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions
•Do not operate unit if the cord or plug is damaged. Doing so can result in electric shock.
Discard the damaged unit or take it to an authorized service facility for examination and /
or repair.
•If the supply cord is damaged, it must be replaced by the manufacturer, service agent, or
similarly quali'ed persons to avoid damage or injury.
•Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners,
or similar coverings. DO NOT ROUTE THE CORD UNDER FURNITURE OR AIR PURIFIER.
Arrange the cord away from traf'c area and where it will not be tripped over.
•Only use the air puri'er as described in this manual.
•Do not unplug by pulling on the cord. Doing so may result in electrical spark or 're. Unplug
the unit by grasping and pulling the plug.
•Do not use this product with an extension cord.
•Do not place the air puri'er near sources of heat. (e.g.: stove tops, ovens, radiators, or
computers)
•Unplug the air puri'er from the power supply before servicing.
•This equipment should be inspected frequently. Any dirt that has collected should be
removed regularly to prevent excessive accumulation that may result in flash over or 're.
•Do not use the air puri'er outdoors or on wet surfaces.
•Do not use the air puri'er in an enclosed space where flammable, combustible or explosive
gases are present.
•Do not use in an area where toxic vapors, flammable dust or oxygen tanks are present.
•Do not place open flames, including candles, directly in front of the air puri'er.
•It is important to keep all objects away from the air intake grill.
•Place the air puri'er on a flat, stable surface. Never place the unit on soft surfaces such as
a beds or sofas.
•Position the air puri'er so that the dirty air is not drawn across your head or body while
sitting or sleeping.
•Place the air puri'er so the plug on the power cord easily reaches a standard electrical
outlet.
•This product is suitable for use with solid-state speed controls.
S A F E T Y P RE CA UT IONS

4Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com
Product Diagram
S A F E T Y P RE CA UT IONS

5
Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions
Instructions for usage
Button Icons:
Power
Speed Low Medium High
Timer
UV
Sleep
Filter Change
Power: When plugged in, the display will turn on for one second and a beep will be heard. The
display will read “OFF”, and the air puri'er will remain in standby state.
F E A T URE S A ND OP E RA T ION

6Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com
Touching the power button will turn on the air puri'er. The unit default is Auto Mode and will
display “000” flashing and “ ”. The air quality indicator on the screen will alternate between
green, yellow, orange and red. Fifteen seconds later, it will show real-time air quality data and
light up with the corresponding color to the table below. After that, air puri'er will adjust the
speed according to the air quality automatically.
Speed: Pressing the “Speed” button will remove the air puri'er from Auto Mode. This button
allows the user to cycle through fan speeds: low speed, medium speed and
high speed.
The fan speed cannot be changed during Auto or Sleep modes.
Timer: Touching the timer button will cause the display to flash “--H” and “TIMER”. Press and
hold the button to set the timer from 1-12 hours. After choosing the desired time, wait two
seconds for the display to stop flashing. After 3 seconds the display will show PM2.5 data,
indicating setting is done. It calculates by counting down every hour. When the time is up, the
air puri'er shuts down.
Touch the button till icon “--H” or long press the button for 2 seconds to cancel timer setting.
UV: Touching the “UV” button turns on the UV sterilization function and lights up the UV
symbol. To turn off the UV function press the “UV” button again, the UV symbol should go
dark.
Sleep: Touching the “Sleep” button will put the air puri'er into Sleep Mode. Sleep Mode uses
the lowest possible fan speed to create a quite environment.
The display and all buttons will turn off leaving only the “Sleep” button lit up at one-third
brightness. Touching the sleep button again will return the unit Auto Mode.
F E A T URE S A ND OP E RA T ION
Auto Mode Chart
Color Air Quality PM2.5 Data Fan Speed
Red Bad >151 High
Orange Moderate 150~101 Medium
Yellow Good 100~51 Low
Green Very Good <51 Lower

7
Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions
F E A T URE S A ND OP E RA T ION
Display Turn Off Function: Press and hold the “Sleep” button for 2 seconds to turn off the
display and buttons, only the “Power” button will be lit at one-third brightness. Touching any
button will illuminate the display, at which point the buttons will function as usual. After 15
seconds without any operation, the display will turn off again. Press and hold the “Sleep”
button to exit display turn off function.
Filter Change
When air puri'er reaches 3,000 working hours, the 'lter change indicator icon in the display
will flash red to remind user change 'lter until the 'lter is changed. After 'lter is changed, in
standby mode, press the “Speed” button two times, then hold this button for 2 seconds, 'lter
change indicator icon will flash quickly. Five seconds later the whole display flashes for a
second and then turn off to enter in standby mode indicating the 'lter change is complete.
Now, touch “Power” button to switch on the air puri'er.
Note: 3,000 hours is calculated based on low speed. It will remind 'lter change less than
3,000 hours if the air puri'er works in other speeds.
Protection
The air puri'er has a protection function. When the 'lter cover is removed or not installed
well, the air puri'er will automatic cut off.
Maintenance
After using the air puri'er for an extended period, dust on the sensor will affect its sensitivity.
We suggest cleaning the unit every two months. But time can be shortened or extended
according to indoor environment.

8Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com
F E A T URE S A ND OP E RA T ION
How to clean the dust sensor
Unplug then open the dust sensor cover and clean with a wet cotton swab. Then dry the lens
with a new, dry cotton swab.

9
Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions
T ROUBL E S HOOT ING
If your air puri'er is not working correctly, please check the table below.
Technical Speci,cations
1. Input voltage: AC 120V
2. Frequency: 60Hz
3. Consumption power: 40W
4. Applicable area: 46m²
5. Noise level: ≤55dB
6. CADR: 230CFM (390m³/H)
7. Operating condition: Temperature: 10°~45°
8. Humidity: ≤95%RH
Problem Possible Reasons Solution
No Power Fault in power source Switch on when the power source gets regular
Not Working
Plug improperly connected
Fault in electrical circuit
Unplug the unit and plug in again
Try using the unit at a different outlet
Unusual Noise
There may be a foreign object in the air puri'er
Dirty 'lter
The 'lter plastic bag was not removed
Take to service center
Replace the 'lter
Remove bag from the 'lter

10 Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com
WA RRA NT Y
We guarantee the unit TO BE free from defects in material or workmanship for a period of one
(1) year from the date of purchase.
Should this unit be operated under conditions other than those recommended or at voltages
other than the voltage indicated on the unit, or any attempts made to service or modify the
unit, this will render WARRANTY VOID. The product you buy may sometimes differ slightly
from illustration.
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of
such waste separately for special treatment is necessary.

Santa-Fe-Products.com
Other manuals for KF-P32
1
Table of contents
Other Santa Fe Air Cleaner manuals
Popular Air Cleaner manuals by other brands

General Filters
General Filters Second Wind NEMA Series Installation & maintenance manual

StressNoMore
StressNoMore E-ZE3 owner's manual

Homemaker
Homemaker KYT-12-YS-02 user manual

Lifa Air
Lifa Air LA503 user manual

GOLDENSEA UV
GOLDENSEA UV UVAIR300-F user manual

ClimateRight
ClimateRight iAirQ450 owner's manual