SAUNACORE "MERCURI" Control Operating Instructions
Display windows:
Left Window “Minutes” Time Display
Right Window “Degrees” Temperature Display
Signaling LED’s:
C - Temperature is displayed in deg C
F - Temperature is displayed in deg F
Heat - Flashing means heater is on
Run - Sauna is during operation cycle
Aux - Auxiliary output is active
Pwr - Unit is connected to power source.
Arrows Up and Down below “Minutes” window change period of the sauna cycle.
Time can be adjusted between 1 to 60 minutes. It is time during which temperature
inside sauna room will be maintained within set temperature +- 3 deg C.
If sauna is not during operation time can be adjusted up and down. During operation
time can be only be adjusted down. Meaning operation period will be decreased.
Arrows Up and Down below “Degrees” window change target temperature of the
operation cycle. Target temperature can be can be adjusted between 1 to 90 deg C
( 32 to 190 deg F).
If sauna is not during operation temperature can be adjusted up and down.
During operation temperature can be only be adjusted down. Meaning target
temperature will be decreased.
During sauna operation Degrees windows will show target temperature for
1 second and current room temperature for 3 seconds.
Unit is capable of displaying temperature both on deg C and deg F. In order to switch
between units both down arrows need to be held continuously depressed for 10 seconds,
until LED beside “degrees” windows changes, lighting up unit required units window (F or C).
As default deg C are selected.
Initially for the first 5 seconds, when either Up or Down key is depressed and held, modified
value (time or temperature) changes every second. If button is pressed continuously for longer
then 5 seconds, changes are more rapid, every 0.5 second, and finally after 15 seconds every
0.25 second, allowing fast wide range changes.
Controller is capable of detecting faulty temperature sensor and overheating of the sauna room.
Message ‘ts’ means temperature sensor problem, message ‘too hot’ means overheating of the room.
In both conditions heater operation is disabled and sauna becomes not operational until first - fault
condition is corrected and secondly unit is restarted by power cycling or error is cleared by continuously
holding start button for 15 seconds.
Sauna operation is triggered by “Start” button. Unit will maintain set temperature for set period of time.
Unit remembers last setting, so if no changes are made and start button is depressed and released,
last used values are used.
After set time expires unit remains in stand-by mode for 10 minutes displaying last time used values
of time and temperature. After that goes to sleep mode, where only PWR LED is on and display is
blanked. Unit wakes-up if any of the buttons is touched.
Unit is equipped with Aux output 120VAC 10 A. This output is controlled by AUX button
and is not associated with sauna cycle. Can be used i.e. for lights, radio, fan etc.
Once turned on will remain on as long as is not turned off by user, regardless of the state of the
sauna room.
6
Figure 99
Figure 88
Coil
Electronic Control
(rear view)
1 Amp
240 V
Fuse
(INLINE)
H1 L1 L2 H2
Temperature Plug
Temperature
Sensor
in sauna
(over stove, ceiling
height)
Control
Ground
H.L.
Heater
Conduit
or BX
Ground
POWER
SUPPLY
Ground
L1
L2
Conduit
or BX
L3
L1
L2
L3
H1 L1 L2 H2
H.L.
Heater
Temperature Plug
Temperature
Sensor
Power Supply
Ground L1 L2
Conduit
or BX
Ground
Control
7 www.saunacore.com
Mercuri Digital Control
SAUNACORE
Mercuri Digital Controls
(120v/240v 1Phase 30 Amps + Under)
(rear view)
Mercuri Digital Controls
(240v/208v) 1 Phase Over 30 Amps or Any 3 Phase)
IMPORTANT!
Loose connections or connectors
may cause electrical shortage.
Make sure all connections and
connectors are firmly secure.
Operation:
Set time and temperature.
Temperature display window will
alternate simultaneously from
current
room temperature and set
tempurature
Note:
All power supply wires
from control box to stove
must be protected by
metal conduit.
(rear view)
AUX
LIGHT
N
LIGHT
N
CAUTION: THE MANUAL RESET LIMIT SHALL BE WIRED IN THE CIRCUIT
For supply connections, use suitable
AWG wires suitable for at least
90 C (190 F). (Use only copper wire).
o
o
Ground wire must be insulated.
Mercuri control must be installed outside of
the sauna room, into a 3 gang masonry
electrical box.
When the magnetic contactor
is used, it also must be installed
into an appropriate metal
electrical enclosure box outside the sauna.
Box Size: 3.5" deep x 3.75" high x 5-19/32" wide
Volume (63 Cu.in.)
Box Size: min 6" wide x 6" high x 3" deep
Volume (108 Cu.in.)
Eurpean Connection
( L2 = N - "Neutral")
8 www.saunacore.com
Mercuri Digital Control
SAUNACORE
Figure 10
Coil
Electronic Control
(rear view)
1 Amp
240 V
Fuse
(INLINE)
H1 L1 L2 H2 Temperature Plug
Temperature
Sensor
in sauna
(over stove, ceiling
height)
Control
Ground
H.L.
Heater
Conduit
or BX Ground
Ground
Conduit
or BX
L1
L2
L3
Coil
HEATER
Conduit
or BX
Ground
L1
L2
L3
Mecuri Digital Control
(240v/208v) 1 or 3 Phase 50 Amps and over)
L1 L2L3
Breaker Panel
Ground
L2
L3
L1
L1 L2
L3
(Main Power Supply)
Mercuri control must be installed outside of the sauna room, into a 3 gang masonry
electrical box. When a magnetic contactor is used, it also must be installed into an
appropriate metal electrical enclosure box outside of the sauna.
For supply connections, use suitable AWG wires suitable for at least 90 C (190 F).
(Use copper wire only). - Ground wire must be insulated. oo
CAUTION: THE MANUAL RESET LIMIT SHALL BE WIRED IN THE CIRCUIT.
(applies to Canadian application)
Terminal Connection
Block

Popular Control Unit manuals by other brands

EnOcean ESK 300 user manual

EnOcean

EnOcean ESK 300 user manual

Texas Instruments ADS7042EVM-PDK user guide

Texas Instruments

Texas Instruments ADS7042EVM-PDK user guide

WAGNER VM 5000 operating manual

WAGNER

WAGNER VM 5000 operating manual

Konica Minolta IP-011 user guide

Konica Minolta

Konica Minolta IP-011 user guide

Ross Vision Crosspoint Module installation guide

Ross

Ross Vision Crosspoint Module installation guide

Vaillant ambiSENSE operating instructions

Vaillant

Vaillant ambiSENSE operating instructions

M-system R3-NL1 instruction manual

M-system

M-system R3-NL1 instruction manual

jbc HDU instruction manual

jbc

jbc HDU instruction manual

Dyna-Flo DF269 Operation, Parts, and Instruction Manual

Dyna-Flo

Dyna-Flo DF269 Operation, Parts, and Instruction Manual

Kessel Pumpfix F Standard Instructions for assembly, operation and maintenance

Kessel

Kessel Pumpfix F Standard Instructions for assembly, operation and maintenance

Land Pride 380-344A installation instructions

Land Pride

Land Pride 380-344A installation instructions

GRAF & MEYER eXentro ECU Safety and Installation Guideline

GRAF & MEYER

GRAF & MEYER eXentro ECU Safety and Installation Guideline

DMP Electronics 734N-WIFI How-to guide

DMP Electronics

DMP Electronics 734N-WIFI How-to guide

BE Ag & Industrial 57GUNMOD Operations & parts manual

BE Ag & Industrial

BE Ag & Industrial 57GUNMOD Operations & parts manual

Congatec SMARC conga-SMX8-X user guide

Congatec

Congatec SMARC conga-SMX8-X user guide

STIEBEL ELTRON WPM G Commissioning

STIEBEL ELTRON

STIEBEL ELTRON WPM G Commissioning

Stahl IS1+ 9475/32-04-72 Series operating instructions

Stahl

Stahl IS1+ 9475/32-04-72 Series operating instructions

Logic Controls LS6000 installation guide

Logic Controls

Logic Controls LS6000 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.