manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. sauter
  6. •
  7. Switch
  8. •
  9. sauter AKM105 User manual

sauter AKM105 User manual

This manual suits for next models

5

Other sauter Switch manuals

sauter EGH102F901 Repair manual

sauter

sauter EGH102F901 Repair manual

sauter AVM 32 Series User manual

sauter

sauter AVM 32 Series User manual

sauter 0370992 Instruction Manual

sauter

sauter 0370992 Instruction Manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1/3www.sauter-controls.com
de Installationsanweisung für die Elektrofachkraft
fr Notice d‘installation pour l‘électricien
en Guidelines for the electrician
it Informazioni per l‘installatore elettrico
es Instrucciones de instalación para el electricista
sv Installationsinstruktion för behörig elektriker
nl Instalatie aanwijzing voor de elektromonteur
de Für den Einsatz in üblicher Umgebung, 3K3 nach EN 60721.
Verschmutzungsgrad II, Überspannungskategorie III,
nach EN 60730.
fr Pour usage dans un environnement normal, 3K3 selon
EN 60721.
Degré de pollution II, catégorie surtension III
selon EN 60730.
en For use in normal environments, 3K3 as per EN 60721.
Pollution degree II, over voltage category III,
as per EN 60730.
it Per impiego in ambiente usuale, 3K3 a norme EN 60721.
Grado di insudiciamento II, categoria di sovratensione III,
a norme EN 60730.
es Para el uso en ambiente normal, 3K3 según EN 60721.
Grado de suciedad II, Categoria de altatensión III,
según EN 60730.
sv För användning i normal miljö, 3K3 enligt EN 60721.
Grad av nedsmutsningsgrad II, Överspänningskategori III,
enligt EN 60730.
nl Voor toepassing in normale omgeving, 3K3 volgens EN 60721.
Vervuilingsgraad II, Overspanningskategorie III,
volgens EN 60730.
de Hilfsschaltereinheit
fr Unité d‘interrupteurs auxiliaires
en Auxiliary switch unit
it Contatti ausiliari
es Unidad conmutador auxiliar
sv Hjälpomkopplarenhet
nl Hulpcontacteenheid
de Montagevorschrift
fr Instruction de montage
en Fitting instructions
it Intruzioni di montaggio
es Instrucciones de montaje
sv Monteringanvisning
nl Montagevoorschrift
0510480001
0510480002
0510480007
AKM105
AKM115(S)
50
°C
0
122
°F
32
WARNUNG
Einsatz bei defektem Kabel verboten.
AVERTISSEMENT
Usage interdit avec câble défectueux.
WARNING
Do not use if the cable is defective.
AVVERTENZA
Impiego vietato nel caso di cavo
danneggiato.
ADVERTENCIA
Está prohibido el uso con un cable
defectuoso.
1
121,4
32
44
69,4
21,2
65,4
5-85%RH
145,5 24
169,5
R70
2.2
1x 1x 2x
VARNING
Förbjuden att använda vid skadad
kabel.
WAARSCHUWING
Gebruik bij defecte kabel verboden.
2.1
2/3 www.sauter-controls.com
3
5
~100 %
+
7
78
2...3
6
9
1
10
3.1
14
3.3
3.2
100 %
2
1+
2...3
de Dokument aufbewahren
fr Ce document est à conserver
en Retain this document
it Conservare il documento
es Guardar el documento
sv Spara dokumenationen
nl Document bewaren
© Fr. Sauter AG
Im Surinam 55
CH-4016 Basel
Tel. +41 61 - 695 55 55
Fax +41 61 - 695 55 10
www.sauter-controls.com
[email protected]
3/3P100002035 B
4
BN RD BK GY VT GN
de braun rot schwarz grau violett grün
fr brun rouge noir gris pourpre vert
en brown red black grey purpel green
it marrone rosso nero grigio porpora verde
es marrón rojo negro gris purpura verde
sv brun röd svart grå violett grön
nl bruin rood zwart grijs violett groen
1C
EN60529
IP40
X
S2
VT
GN
GY
BK
RD
BN
X
S1
0510480002, 0510480007
RD
BN
BK
GN
GY
VT
0510480001
RD
BN
BK
BK
RD
BN
X
S1
0...100 % (man/auto)
230V 5(2)A
0510480001: Xs1
0510480002: Xs1/Xs2
1
2
0510480007: Xs1/Xs2
2...3
4a
0%(man/auto)
230V 5(2)A
0510480001: Xs10...100 %
0510480002: Xs1/Xs20...100
...100
%
2
1
0510480007: Xs1/Xs20 %
2...3
4b