ENGLISH
TABLE OF CONTENTS
SAFETY ...................................................................................................................3-6
Safety Labels 3
Safety Instructions 4-5
Limitations on Use 6
INTRODUCTION............................................................................................................. 7
ASSEMBLY .............................................................................................................. 8-11
Unpacking 8
Parts & Replacement Information 9
Assembly Instructions 10-11
OPERATION ............................................................................................................ 12-13
Quick Start Guides 12-13
SERVICE INSTRUCTIONS & MAINTENANCE INFORMATION............................................................. 14-18
Maintenance Information 14-18
Bulb Breakage & Disposal 15
Bulb Replacement 15
Filter & Fuse Replacement & Disposal 16-17
Troubleshooting 18
DISCLAIMER ...............................................................................................................19
WARRANTY ................................................................................................................20

3©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
SAFETY LABELS
Read, Understand, and Follow All Safety Instructions
Save all Warnings and Instructions for future reference
All personnel should be alerted to the potential hazards indicated by the product safety labeling of this unit
The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to
observe precautions could result in electric shock, re and/or serious injury to people or damage to property.
This symbol is used to alert you of potential
personal injury hazards.
This symbol is used to identify an ELECTRICAL
SHOCK or ELECTROCUTION hazard.
This symbol is used to identify ULTRAVIOLET
LIGHT hazard.
This symbol is used to identify the need to wear
approved ultraviolet blocking eye wear. Always
protect eyes and skin from direct reflected
radiation.
This symbol is used to identify the need to wear an
approved ultraviolet blocking face shield. Always
protect eyes and skin from direct reflected radiation.
This symbol is used to identify components which
must not be disposed of in the trash.
This symbol is used to identify the need to wear
protective gloves.
CAUTION indicates a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
CAUTION
WARNING
WARNING indicates a potentially
hazardous situation which, if not avoided,
COULD result in serious injury or death.

4
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
To guard against injury, basic safety precautions should be observed, including the following:
WARNING
Read, understand, and follow ALL instructions in this manual
before assembling, starting, or servicing the unit. Improper use of
the unit can cause serious injury.
WARNING
Avoid exposure to direct or reected germicidal ultraviolet rays.
Germicidal ultraviolet rays are harmful to eyes and skin.
WARNING
Intended for indoor use only. To reduce risk of electric shock, do
not expose to water or rain.
WARNING
Do not alter design or construction of the product. Damage or
personal injury could result.
WARNING
Do not use this xture for anything other than its intended
purpose, as described in this manual.
CAUTION
Do not override safety interlock.
WARNING
Do not mount under any source of moisture or condensation
such as humidiers, cooling coils etc.
CAUTION
DO NOT remove any labels or devices.
WARNING
Do not operate without proper electrical ground.
WARNING
Do not operate the unit if there is visible or suspected damage to
the unit or, if applicable, if there is damage to the power cord and
or plug.
CAUTION
Keep inlet and outlet of the blowers clean and clear of debris.
WARNING
Do not operate without access cover secured.
CAUTION
Stay clear of blowers or other moving parts that can cause injuries.
CAUTION
Do not use to exhaust hazardous or explosive materials and
vapors. Never use in spaces which contain products such as
gasoline, solvents, paint thinners, dust particles, volatile or
airborne combustibles, or any unknown chemicals.
WARNING
This product can expose you to chemicals, including lead and
lead compounds, which are known to the State of California to
cause cancer and birth defects or other reproductive harm. For
more information go to www. P65Warnings.ca.gov.
WARNING
Never leave the unit unattended while operating or while
connected to a power source.
WARNING
This is not a toy. To reduce the risk or personal injury and electric
shock, the unit should not be played with or placed where small
children can reach it.
WARNING
To reduce the risk of re or electric shock, do not use this unit with
any solid-state speed control device.
WARNING
To reduce the risk of electric shock and injury to persons, do not
use near a window.
WARNING
Do not operate any unit with a damaged cord or plug. Discard unit
or return to an authorized service facility for examination and/or
repair. Do not run cord under carpeting. Do not cover cord with
throw rugs, runner, or similar coverings. Do not route cord under
furniture or appliances. Arrange cord away from trac areas and
where it will not be tripped over.

5©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Always use on a dry, level surface.
WARNING
Do not attempt to repair or adjust this unit aside from replacing the
bulb or lter. Doing so will void warranty. Replace bulb and lter
with only genuine Defender parts.
WARNING
Improper connection of the equipment-grounding conductor
can result in a risk of electric shock. Check with a qualied
electrician or service person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the plug provided
with the appliance if it will not t the outlet. Have a proper outlet
installed by a qualied electrician.
WARNING
Utility power supplied to the unit must match power
requirements listed on the unit label.
WARNING
Always disconnect power to the unit before performing any
service or maintenance.
WARNING
Read and follow all notices and warnings on the unit.
WARNING
To reduce the risk of re, electric shock or injury to persons, do
not use replacement parts that have not been recommended by
the manufacturer (e.g. parts made at home using a 3D printer).
WARNING
This product employs overload protection (fuse). A blown fuse
indicates an overload or short-circuit situation. If the fuse blows,
unplug the product from the outlet. Replace the fuse as per the
user servicing instructions (follow product marking for proper
fuse rating) and check the product. If the replacement fuse
blows, a short-circuit may be present and the product should
be discarded or returned to an authorized service facility for
examination and/or repair.
WARNING
Skin or eye damage may result from directly viewing the light
produced by the lamp in this apparatus. Always disconnect
power before relamping or servicing. Replace lamp with lamp
Model No. D-AV1000-UVC-10 if ordered directly from Pinnacle
Climate Technologies, Inc. or PN Signify TUV PL-L 24W.
WARNING
Do not use outdoors.
WARNING
Before operating, always check fan for loose or damaged parts.
Inspect power cord for any damage. Never use fan if any parts are
damaged or missing.
WARNING
Operate only on 120 volt 60 Hz (cycle) current with a minimum of
a 15 amp circuit.
SAVE THESE INSTRUCTIONS.

6
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
LIMITATIONS ON USE
WARNING CAUTION
OVEREXPOSURE TO GERMICIDAL ULTRAVIOLET RAYS WILL
RESULT IN THE IRRITATION OF THE EYES AND THE REDDENING
OF THE SKIN. FOR THAT REASON, THE DEVICE IS EQUIPPED
WITH A DOOR INTERLOCK WHICH DISABLES THE UV-C LAMP
WHEN THE CABINET DOOR IS OPEN.
IF USER OVERRIDES CABINET DOOR INTERLOCK, RESULTANT
EXPOSURE TO UV-C LAMP RADIATION EXCEEDS DAILY
RECOMMENDATIONS AND WILL CAUSE INJURY TO USER AND
DAMAGE TO EQUIPMENT.
AV1000 IS INTENDED FOR INDOOR USE ONLY. FAILURE TO
FOLLOW THIS WARNING MAY RESULT IN SERIOUS INJURY,
ELECTROCUTION, BURNS AND OR DEATH.
THE FAN USED IN THE AV1000 UNIT IS A ROTATING PIECE OF
EQUIPMENT RUNNING AT 3,000 RPM. ALWAYS SHUT DOWN
THE EQUIPMENT PRIOR TO SERVICE WORK. UNPLUG IT FROM
IT’S POWER SOURCE AND WAIT A MINIMUM OF ONE MINUTE
FOR THE FAN TO STOP PRIOR TO UNLOCKING THE DOOR FOR
SERVICE. THE AV1000 UTILIZES SAFETY SWITCHES IN THE
DOOR THAT AUTOMATICALLY DISENGAGE POWER TO THE
UNIT UPON OPENING. IF THE DOOR IS OPENED WHILE THE
UNIT IS RUNNING, POWER WILL AUTOMATICALLY SHUT OFF;
IN THIS CIRCUMSTANCE, THE FAN WILL STILL BE IN ROTATION
AND BEGIN WINDING DOWN WHEN THE DOOR IS OPENED.
THIS PRESENTS A HAZARD TO PERSONNEL AS A ROTATING FAN
BLADE OF THIS NATURE CAN CAUSE HARM. ONLY CERTIFIED
TECHNICIANS SHOULD BYPASS PROPERLY SHUTTING DOWN
THE EQUIPMENT PRIOR TO OPENING THE DOOR FOR ANY
REASON.

7©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
INTRODUCTION
The Defender by Schaefer™AV1000 Air Purication unit is
designed for ambient capture in commercial and institutional
settings. The fan is designed to move up to 1,000 CFM, capturing
and destroying chemical and biological contaminants.
How the AV1000 Works
1. Air is drawn into the AV1000 through the bottom grate.
2. Air is pulled through the carbon lter, which removes
Volatile Organic Compounds (VOC's).
3. Air moves through the antimicrobial pre-lter to remove
microorganisms.
4. Air is then further circulated through the destroy chamber
and any residual aerosolized particles are exposed to
germicidal UV-C light.
5. Air travels through the HEPA lter, which is 99.99% ecient at
0.3 micron particulate.
The combination of UV-C sterilization chamber with True HEPA*
ltration delivers 99.99% puried air back into the workplace.
Model Name AV1000
Airow 1,000 CFM (1,700 m³/hr)
Height 90.75 in. (2305.1 mm)
Width 30.72 in. (780.4 mm)
Depth 15.42 in. (391.8 mm)
Power Supply Single phase 115 V – 60 Hz
Current 10 amps
Weight 230 lbs. (104.3 kg)
Coverage Area 9,000 cu. ft. (836 m³)
UV-C Wavelength 254 nm
*A True HEPA ltration device or lter is the only type of HEPA lter that truly conforms to the
DOE standard for HEPA ltration, has the highest eciency, and hits the 99.97% threshold.
If the HEPA lter does not meet the DOE’s standards for HEPA ltration, then it is not
considered True HEPA.

8
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
ASSEMBLY INSTRUCTIONS - UNPACKING
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE
FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A
FACE SHIELD, AS WELL AS GLOVES
CAREFULLY READ ALL UNPACKING INSTRUCTIONS PRIOR
TO UNPACKING UNIT
What is included in the packaging?
(1) AV1000
(2) User manual
(3) Wall brackets
(4) UV-C bulbs (10) 24W
(5) One (1) Large Hex key (8mm)
(6) One (1) Small Hex key (1/8”)
1. Inspect the AV1000 package for damage. Immediately
record any packaging defects via photograph. Make a
note to the shipping company on the manifest or waybill
indicating that the carton was damaged. Then, send the
damage report, waybill with damage noted, and photos to
Pinnacle Climate Technologies (PCT).
customerser[email protected]
2. PCT takes all possible precautions when packaging this
device to prevent damage occurring during shipping. The
AV1000 is shipped as one package, with a smaller package
within the main package that contains the UV lamps.
3. Each of the MERV 8, Carbon, and HEPA lters are pre-
installed and ready to use, to ensure maximum protection.
4. Do not discard the packing materials until the device is
assembled and a working inspection is complete.
5. It is recommended to use the proper lifting equipment
when transporting the unit to the nal location where the
unit will be installed (See Below).
6. You must install bulbs prior to use. See Page 11.

9©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
ASSEMBLY INSTRUCTIONS -
PARTS AND REPLACEMENT INFORMATION
The AV1000 device consists of:
A. Wall bracket (see pg.10 for installation instructions).
B. A 99.99% ecient at 0.3-micron, True HEPA*lter.
C. Ten (10) 24-watt OEM supplied Philips (by Signify) compact
UV-C germicidal lamps designed for use in professional water
and air disinfection units.
D. A MERV 8 pleated lter.
E. A MERV 6 carbon impregnated prelter.
A
B
C
D
E
*A True HEPA ltration device or lter is the only type of HEPA lter that truly conforms
to the DOE standard for HEPA ltration, has the highest eciency, and hits the 99.97%
threshold. If the HEPA lter does not meet the DOE’s standards for HEPA ltration, then it is
not considered True HEPA.
SCAN FOR REPLACEMENT PARTS

10
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
Read all instructions prior to assembly.
Warranty is voided if the wall bracket is not installed and
correctly secured to the wall.
NOTE: Due to the variable nature of the location of placement,
the bolts for securing the unit to the wall are not included. A
qualied installer is required to select the appropriate bolts for
the specic structure.
REQUIRED TOOLS ( NOT Included)
• One (1) Medium Hex Key (5/32”)
1. Locate the studs for securing the L shape bracket (Fig.1) to
wall, consult an engineer if required, and follow all local
building codes and bylaws related to seismic restraint.
2. Put the unit in place and level it.
3. Remove 3 screws at the top of the unit, with included
Medium Hex Key.
4. Secure the L shape bracket (Fig. 2) to the unit with screws or
bolts. L bracket can either be mounted up or down.
5. Remove the bracket from the unit. Use the L shape bracket
as a guide to mark drill holes on the wall where the 3 screws
will go. Remove bracket from the wall and drill the holes. Bolt
the bracket back to the wall. Note: when cutting or drilling
into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
6. Line up slots on L shape brackets with the 3 screws that were
previously removed. Reinstall the 3 screws to the unit with
the Medium Hex Key and leave loose for nal adjustment.
7. Make sure unit sits at 90 degrees with a level. The unit comes
with four leveling legs, which can be adjusted to level the
unit. If you need to adjust the rear leveling legs, remove the
back cover. (Fig. 3)
8. Once the unit is leveled, tighten the 3 screws and unit to the L
shape bracket attached to the wall.
ASSEMBLY INSTRUCTIONS
Fig. 1
Fig. 2
Fig. 3

11 ©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
ASSEMBLY INSTRUCTIONS
The unit should be hung and secured before rigging and
assembling it.
Always disconnect power to fixture before performing any
service or maintenance.
WARNING
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE
FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE
SHIELD, AS WELL AS GLOVES.
1. If you are sure that there is no shipping damage, put on
your safety goggles and gloves and remove the device from
its packaging.
2. Ensure the machine is UNPLUGGED. Open the main door
using the Large Hex Key.
3. Remove the UV-C chamber cover by removing the 12
screws with the Small Hex Key, as shown.
4. Using safety goggles and gloves, remove the lamps from
their packaging. Do not touch lamp with bare skin, this will
reduce the life of the bulb(s).
5. Insert each lamp into its socket, then secure lamps
into their respective clamps.
6. Re-install the UV-C chamber cover and 12 screws with the
Small Hex Key.
7. Close and secure the main door using the Large Hex Key,
ensuring all latches are completely secured. The unit will
not run if the door is not secured.
8. Once installed, follow the quick start guide to ensure the
machine is working as expected.
REQUIRED TOOLS (Included)
• One (1) Large Hex key (8mm)
• One (1) Small Hex key (1/8”)

12
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
QUICK START GUIDE
Plug the device into a standard, 120V outlet and follow these steps to verify proper operation.
The “Start Center” page will appear on power up.
To open the unit’s main screen, press the “Start”
button in the center of the page.
The main page will be locked by default on power up.
To unlock the display, press the F4 button located at bottom
right of the screen frame. The “SCREEN LOCKED” indication will
disappear, and the screen controls can be manipulated.
To relock the screen press F4.
Ensure the door of the unit is closed.
You should see this as the initial start screen.
Wait until the Start Center screen appears. To start the unit rst chose the desired running mode by
pressing the shield button.
Defend – Normal Fan Speed
Defend Plus – High Fan Speed
Press the power button to start the unit.
The unit will run continuously.
To stop the unit, press the power button.
The AV1000 “Defend mode” can be used with a daily timer to switch
from “Defend Mode Plus” (high speed) for a set amount of time.
To set the time for “Defend mode” press the SETTINGS button on
the main page.
Press the DEFEND MODE BUTTON on the statistics page.
DEFEND MODE SETTINGS

13 ©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
QUICK START GUIDE
LAMP & FILTER STATISTICS
The total run hours and remaining hours for the UV bulbs can be
found on the “Statistics” screen.
The current draw of the light ballasts and motor are displayed in
amperes on the top right-hand side of the page.
Total run hours and remaining hours can be found for the HEPA Filter.
See the maintenance section for replacement information.
Total run hours and remaining hours can be found for the Carbon Filter.
See the maintenance section for replacement information.
DEFEND MODE SETTINGS CONTINUED
Before using the “Timed Defend Mode” setting ensure the time of
day is reading correct.
This is displayed in the “System Time” at the bottom of display.
If the time is not correct press the “SET TIME” button
Set the time using the shown boxes.
*Note the year is only set with the last 2 digits Example: 2023 would be written as 23
.
Press the “BACK” button to return to the timed defend mode page.
Enter in the desired time of day to switch from “Defend mode plus”
to “Defend mode” the unit will operate in “Defend mode” within the
specied timed period.
Press the “Enable Timed Defend Mode” power button to enable the
timed defend mode.
Press the home button on the bottom left to return to the main page.

14
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
SERVICE INSTRUCTIONS & MAINTENANCE INFORMATION
The AV1000 is designed to operate with a minimal amount of
maintenance.
UV Lamp:
The bulb is rated from the manufacturer for 7,000 hours of
continuous us under normal operating conditions. The lamps
are recommended to be replaced every 1-2 years to ensure
their operational eectiveness.
HEPA Filter:
Required to be replaced once each year under normal
operating conditions. HEPA lters are NOT washable.
Carbon Filter:
Required to be replaced quarterly each year (every 3 months)
under normal operating conditions. Carbon lters are NOT
washable.
ANNUAL GENERAL INSPECTION
The sealing integrity of the AV1000 is crucial. It is essential to
verify that all gaskets are in proper condition to prevent any
leakage or bypass of the contaminated air.
No motor maintenance is required.
LAMP BREAKAGE & DISPOSAL
WARNING CAUTION
Do not override the safety interlock switch. Always disconnect
power to the xture before performing any service or
maintenance. Operation of the xture with the interlock switch
overridden and the Access Door open will expose personnel
to direct or strongly reected germicidal ultraviolet rays.
Germicidal ultraviolet rays are harmful to the eyes and skin.
Avoid exposure to direct or reected germicidal ultraviolet
rays.
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE
FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE
SHIELD, AS WELL AS GLOVES.
IN CASE OF BULB BREAKAGE
Wear protective gloves, safety glass, or a face shield when
handling broken ultraviolet lamps. In the event of breakage,
DO NOT use a household vacuum cleaner to pick up quartz
fragments. Sweep debris into a plastic bag and dispose of
properly.
Broken quartz is SHARP.
CAUTION
Germicidal ultraviolet lamps, like standard uorescent lamps,
contain small amounts of mercury. Mercury-added lamps
should not be placed in the trash. Dispose of properly. For
further information regarding the disposal and recycling of
lamps containing mercury, reference the following source
from the Environmental Protection Agency: https://www.epa.
gov/c/recycling-and-disposal-cs-and-other-bulbs-contain-
mercury

15 ©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
1. Disconnect power from the device and unplug the power
cord. WAIT ONE (1) MINUTE TO ALLOW FAN TO CYCLE
DOWN TO A FULL STOP.
2. Put on safety goggles and gloves before unlocking and
opening the door.
3. Open the main door using the included Large Hex Key.
4. Remove the UV-C chamber cover using the included Small
Hex Key.
5. Using safety goggles and gloves, remove the old lamps
from the clamps and sockets in the device and place them
in a secure space where they will not fall or break.
6. Using safety goggles and gloves, carefully remove the new
lamps from their packaging. Do not let skin touch the new
bulbs. This will greatly reduce the bulb life.
7. Insert each lamp into its socket, then secure lamps into
their respective clamps.
8. Re-install the UV-C chamber cover using the Small Hex Key.
9. Close and secure the main door using the Large Hex Key,
ensuring all latches are completely secured.
10. Properly dispose of old lamps utilizing recycling
procedures in your area. Refer to the previous page if a
lamp breaks.
SERVICE INSTRUCTIONS & MAINTENANCE INFORMATION
UV-C LAMP REPLACEMENT
SCAN FOR HOW TO REPLACE LIGHT BULBS

16
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
FILTER & FUSE REPLACEMENT & DISPOSAL
HEPA FILTER & CARBON FILTER
Always disconnect power to the fixture before performing any
service or maintenance.
WARNING
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE
FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE
SHIELD, AS WELL AS GLOVES.
FILTER-ALERT SYSTEM & FILTER REPLACEMENT
Proper maintenance of the unit is critical to extend the life and the
overall ecacy of the system. The information below outlines basic
maintenance procedures to ensure the unit will operate trouble-
free for years to come.
When the HEPA lters have reached the pre-set total pressure drop
of 1 inch of water, you will see a display warning on the HMI screen
“Alarm message HEPA lter clogged.”
Description Replacement
Frequency Part Numbers
HEPA Filter, 99.99% @ 0.3 micron Every 12 months D-AV1000-H
MERV 8, Pleated Filter Every 3 month D-AV1000-PF
Carbon Filter Every 3 month D-AV1000-CF
Annual Filter Pack (1 HEPA Filter, 4 Pre-Filters,
4 Carbon Filters, and lubricant) As needed D-AV1000-AFP
UV 24 W Bulb Every 1-2 years D-AV1000-UVC-1
UV 24 W Bulbs - Kit (10 bulbs) Every 1-2 years D-AV1000-UVC-10
Replacement Key, Small - Hex L-Key with
Standard Tip, 1/8" Size, 3-15/16" Overall Length NA GC-02257
Replacement Key, Large - Hex L-Key with
Standard Tip, 8 mm Size, 4-5/16" Overall Length NA GC-02194
Ballast As needed IUV2S36M2LD35M
2.0 Amp Fuse As needed GGM2
5.0 Amp Fuse As needed GGM5
SCAN FOR REPLACEMENT PARTS

17 ©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
FILTER REPLACEMENT
Please note that it is critical for the HEPA lters to be tight and
secure to avoid by-pass of the contaminants.
Applying the provided lubricant to the gasket prior to installing
new lter will make it easier to install and remove the lter.
To remove the HEPA lter, pull the handle and slide out the lter
upward toward you. Be carefully not to damage the aluminum
shield below the lter.
1. Disconnect power from the device and unplug the power cord
WAIT ONE (1) MINUTE TO ALLOW FAN TO CYCLE DOWN TO A
FULL STOP.
2. Put on eye protection, face mask and disposable gloves.
3. Open the main door using the Large Hex Key.
4. Remove HEPA, Carbon lter and/or MERV 8 lter from its
housing, noting airow direction.
5. Install replacement lter into the housing, ensuring that airow
direction is correct. For HEPA lter replacement, the lubricant
must be applied to the gasket.
6. Close and secure the main door using the Large Hex Key,
ensuring all latches are completely secured.
FUSE REPLACEMENT
Please call a service technician to replace fuse.
There are two fuses. The fuse for the power supply is a GGM2,
2 amp 250V rated fuse. The fuse for the light circuit and the motor
circuit is a GGM5, 5 amp 250V rated fuse.
Note: GGM type fuses are rated for voltages up to 250V. The fuse
will be marked with a 250V rating.
1. Grasp plug and remove from the receptacle or other outlet
device. Do not unplug by pulling on cord.
2. Open fuse cover by unscrewing the rear panel.
3. Remove fuse from the fuse holder carefully.
Risk of re. Replace fuse only with appropriate fuse.
4. Close fuse cover by installing the rear panel with screws.
FILTER & FUSE REPLACEMENT & DISPOSAL
SCAN FOR HOW TO REPLACE FILTERS

18
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
IMPORTANT: This unit is to be serviced ONLY by qualied and
appropriately trained and/or licensed personnel.
WARNING
Always disconnect power to the xture before performing any
service or maintenance.
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE
FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE
SHIELD, AS WELL AS GLOVES.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Unit is not
operating
No electrical power Verify that unit is connected to a live power source
Power connection to device is
loose or disconnected Verify power connection to device is fully engaged
Internal fan is
not blowing
Loose power connection Conrm connection to blower; connection is tight
and makes full contact
Faulty fan motor Replace blower motor
UV Lamp is not
functioning
Lamp ballast is not functioning Swap lamp with known good lamp. If lamp still
does not operate, replace ballast
Lamp is not functioning Swap lamp with known good lamp. If lamp still
does not operate, replace with new lamp
Lamp not properly seated Conrm full contact of lamp to lamp holder
Interlock switch open Conrm access door is closed and locked
Interlock switch faulty Replace interlock switch
Key Pad is not
responding
Display is locked Press F4 Key on Display Screen
Control is Frozen Unplug unit, wait 5 minutes, plug unit back in to
reboot
Unit is louder
or making a
whistling noise
HEPA Filter needs to be replaced See page 17
Air inlet or outlet is blocked Clear openings and make sure there is not any
loose materials blocking the lters internally

19 ©2022 Defender by Schaeferwww.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
DISCLAIMER
KEEP THIS MANUAL IN A CLEAN, DRY PLACE FOR FUTURE REFERENCE.
The purchaser of this equipment (the “User”) acknowledges and is aware of the contagious nature of the Coronavirus/COVID-19 and like
viruses. Use of this product does not guarantee that parties will not become infected with/exposed to Coronavirus/COVID-19 and
other pathogens, including but not limited to influenza, SARS, MERS, Hepatitis, Varicella, Tuberculosis, Endemic Coronavirus,
HPV, aerosolized mercury, etc.
The User understands that the risk of becoming exposed to and/or infected by the Coronavirus/COVID-19 may result from actions,
omissions, or negligence of the User and others, including, but not limited to, User sta, and other User clients and their families.
It is the User’s responsibility to determine and validate the suitability of this equipment for use in the User’s environment. No representation
is made by the Manufacturer with respect to the suitability or performance of this equipment or to the impact that may result from its use.
Additionally, the user should periodically inspect the equipment, clean as necessary, and conrm the presence and good legibility of the
product safety labels. Contact PCT for replacement labels.
If you need replacement parts, please call Pinnacle Climate Technologies (PCT) at 800-779-3267, or visit
https://schaeferventilation.com/contact-us/.
All information, illustrations and specications in this manual are based on the latest product information available at the time of printing.
Product specications subject to change without notice.

20
©2022 Defender by Schaefer www.schaeferventilation.com/defender/ • 800.779.3267
ENGLISH
SCHAEFER LIMITED WARRANTY
I. A limited warranty with a brand- or product specific
term (see Section III below) applies to all products,
components and assemblies provided by PCT that prove
to be defective in material or workmanship, unless
noted below as an exception.
•Any such defective product will be replaced or repaired at
PCT’s option.
• Defective products shall only be returned to PCT with the
approval of PCT and at customer’s expense.
• Replacement products or repair parts will be shipped to
customer at PCT expense.
• Field repairs will be performed by customer at customer’s
expense.
II. This limited warranty does not cover:
a. Failure, damage or malfunction as a result of:
i. Improper installation or installation not in accordance
with installation instructions.
ii. Operating conditions that reasonably would be |
expected to damage the product and/or vary from
PCT’s operating instructions.
iii. Misuse, abuse, negligence, alteration, or accident.
iv. Damage incurred while transporting the product.
v. Improper operation of the product.
vi. Lack of appropriate or regular maintenance of the
product, including, but not limited to, operating the
product with debris buildup on the motor or blade.
b. Loss of time, inconvenience, loss of use of the product or
other consequential or incidental damages.
c. Wear part replacement.
d. Supercial or cosmetic rust or corrosion.
e. Damage to a product whose name plate has been removed.
f. Damage to a product that has been modied in any way.
III. Warranty Term*
• Schaefer Defender – 2 years
* PCT reserves the right to add or remove brands, products or
components to/from this Warranty Term List at any time. If
there is a warranty term discrepancy between this Warranty
Term List and the product’s operating manual, the shorter of
the terms shall apply.
IV. Other
• There are no warranties of merchantability or tness of use.
• PCT reserves the right to change product designs and
specications without prior notice or liability.
• The above constitutes the sole warranty oered by Pinnacle
Climate Technologies.
Effective Date: December 1, 2016
Return of Stock Merchandise
No merchandise may be returned without a Return
Authorization from the Pinnacle Climate Technologies
Customer Care Center. Return Authorization must be
obtained within 30 days of the date of purchase. Return
Authorizations expire 30 days after date of issue and will not
be re-issued.
All returns must be shipped prepaid to the Pinnacle
Climate Technologies location designated on the Return
Authorization. For standard products in “like new” condition,
credit will be issued minus a 25% restocking fee and any
unpaid freight charges, after receipt and inspection of
the product at Pinnacle Climate Technologies. For custom
products and standard products returned in less than “like
new” condition, the restocking fee will be determined upon
inspection and will range from 30% to 100%. Obsolete
products are not returnable.
A BRAND OF PINNACLE CLIMATE TECHNOLOGIES™
www.schaeferventilation.com/defender
800.779.3267
©2022 Defender by Schaefer
Pinnacle Climate Technologies (PCT) provides the following limited warranty from the date of invoice to the initial purchaser of
our products or to its customer with a dated proof of purchase:
Schafer is a register trademark of Pinnacle Climate Technologies, inc.
Defender by Schafer name and logo are trademarks of Pinnacle Climate Technologies, inc.
Table of contents
Other Schaefer Air Cleaner manuals