schanz Studio Star Operating manual

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 1 von 16
Setting Instructions
Electronic Motor
-Studio Star-
This Operating Instruction contains important safety instructions. For
the safety of persons it is important to follow these instructions.
This instruction should be kept.
Schanz Rollladensysteme GmbH
Forchenbusch 9
D- 72226 Simmersfeld
Tel. +49 (0)7484/9291-0
Fax: +49 (0)7484/ 9291-36
Internet: www.rollladen.de

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 2 von 16
Content
1. Setting the drive into learning mode........................................................................................................................................3
1.1. Setting with test cable.....................................................................................................................................................3
1.2. Setting with micro switch and switch..............................................................................................................................3
2. Setting Instructions - Type: S, GS, SI, SIG, R, G....................................................................................................................4
2.1. Overview Off-Mode 1 – Only suitable for type S ............................................................................................................4
2.2. Overview Off-Mode 2 - For all types with box on bottom ...............................................................................................4
2.3. Setting Off-Mode 1 (with test cable) - Only suitable for type S.......................................................................................5
2.4. Setting Off-Mode 1 (with micro switch and switch) - Only suitable for type S ................................................................6
2.5. Setting Off-Mode 2 (with test cable) – For all types with box on bottom........................................................................7
2.6. Setting Off-Mode 2 (with micro switch and switch) – For all types with box on bottom..................................................8
3. Setting Instructions - Type: GU, SU, GSU, SIU, SIGU, RU ....................................................................................................9
3.1. Overview Off-Mode 1......................................................................................................................................................9
3.2. Overview Off-Mode 2 – Standard for type GU ...............................................................................................................9
3.3. Overview Off-Mode 3......................................................................................................................................................9
3.4. Overview Off-Mode 4......................................................................................................................................................9
3.5. Setting Off-Mode 1 (with test cable).............................................................................................................................10
3.6. Setting Off-Mode 1 (with micro switch and switch).......................................................................................................10
3.7. Setting Off-Mode 2 (with test cable) - Standard for type GU........................................................................................11
3.8. Setting Off-Mode 2 (with micro switch or switch) - Standard for type GU....................................................................12
3.9. Setting Off-Mode 3 (with test cable).............................................................................................................................12
3.10. Setting Off-Mode 3 (with micro switch and switch).......................................................................................................13
3.11. Setting Off-Mode 4 (with test cable).............................................................................................................................14
3.12. Setting Mode 4 (with micro-switch or switch) ...............................................................................................................15
4. Copyright / References to this documentation ......................................................................................................................16
General Information:
The motor is fitted with an overheating protection.
In case the motor switches off through overheating it can only be put into service again after a
common cooling phase.
If a mistake occurs during the learning process, the power fails or the overheating protection
starts, the setting of the end-points has to be performed again.
In the event of a malfunction in the direction UP or DOWN a start in the same direction is not pos-
sible, the drive must be freed at first in the opposite direction.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 3 von 16
1. Setting the drive into learning mode
1.1. Setting with test cable
Step No. Operation Note Check
The motor is delivered in learning mode. If a fault occurs during the programming or if an already programmed drive
should be installed in a different position or changes were made to the roller shutter, then the drive can be set again
into learning mode. All defined values will be deleted.
Therefore and for setting the endpoints in mode 2-4 a special test cable is necessary so that UP and DOWN can be
pressed simultaneously.
10
Press either both buttons or the programming button* for at least
6 sec. until the drive twitches once.
If the drive is already in learning mode a second twitch occurs af-
ter approx. 1 sec. This has to be ignored.
Note:
This step can be ignored when setting the roller shutter for the
first time as the drive is in learning mode upon delivery.
*Depending on test cable model
1.2. Setting with micro switch and switch
Step No. Operation Note Check
The motor is delivered in learning mode. If a fault occurs during the programming or if an already programmed drive
should be installed in a different position or changes were made to the roller shutter, then the drive can be set again
into learning mode. Besides all values are deleted.
10
Keep the button in the micro-switch pressed.
Keep the UP or DOWN button pressed for 6 sec. until the drive
twitches once.
If the drive is already in learning mode a second twitch occurs af-
ter approx. 1 sec. This has to be ignored.
If the drive does not move, release the micro-switch and bring the
control switch back in the neutral position.
Then again keep the button in the micro-switch pressed and
press the other UP or DOWN button for 6 sec. until the roller
shutter slat twitches once.
The button that functions is from now the active button. For
any further setting this active button has to be used.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 4 von 16
2. Setting Instructions - Type: S, GS, SI, SIG, R, G
The drive has 2 different switching modes, the selection takes place automatically via the setting.
2.1. Overview Off-Mode 1 – Only suitable for type S
Upper end position about torque detection
(shutter moves against the stop) / End position
down after putting on the armor guided tour through
the system detects that the winding shaft.
An end position readjustment, caused by elongation or
Cord elongation, automatically carried out from the up-
per end position.
2.2. Overview Off-Mode 2 - For all types with box on bottom
Upper end position about torque detection
(shutter moves against the stop) / set end position
bottom.
An end position readjustment, caused by elongation or
Cord elongation, automatically carried out from the up-
per end position.
Note
After the installation of the drive the spring shaft can be loaded via the programming button and the cord can be put in the cor-
rect position.
- Please note the separate instructions
-Upon delivery, unnecessary
If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be set into learn-
ing mode again.
Important! Adhere to the sequence, first the upper and then the lower float stop has to be
teached.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 5 von 16
2.3. Setting Off-Mode 1 (with test cable) - Only suitable for type S
(Upper end position about torque detection / End position down after putting on the armor guided tour through the system de-
tects that the winding shaft) - Automatic setting
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for
at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-Button,
until the lower end position is reached and the drive switches off
automatically shortly after the fastening of the end rod. Keep
pressing the button for at least 1 sec. longer after switching off.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 6 von 16
2.4. Setting Off-Mode 1 (with micro switch and switch) - Only suitable for type S
(Upper end position about torque detection / End position down after putting on the armor guided tour through the system de-
tects that the winding shaft) - Automatic setting
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button
for at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-Button,
until the lower end position is reached and the drive switches off
automatically shortly after the fastening of the end rod. Keep
pressing the button for at least 1 sec. longer after switching off.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 7 von 16
2.5. Setting Off-Mode 2 (with test cable) – For all types with box on bottom
(Upper end position about torque detection / set end position bottom)
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button
for at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-Button,
until the desired position is reached. The end rod is in the area of
the end stop, the cord is not yet loose.
Moving back or moving in short impulses is allowed.
30
Press both buttons simultaneously or the programming button* for ca. 2 sec. in order to learn the
lower position. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
The setting mode is exited.
*Depending on test cable model
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 8 von 16
2.6. Setting Off-Mode 2 (with micro switch and switch) – For all types with box on bottom
(Upper end position about torque detection / set end position bottom)
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for
at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-Button
until the desired position is reached. The end rod is in the area of
the end stop, the cord is not yet loose.
Moving back or moving in short impulses is allowed.
30
First press the micro switch and then the active button for ca. 2 sec. in order to learn the lower po-
sition. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 9 von 16
3. Setting Instructions - Type: GU, SU, GSU, SIU, SIGU, RU
The drive has 4 different switching modes, the selection takes place automatically via the setting.
3.1. Overview Off-Mode 1
Upper and lower end position about torque detec-
tion (shutter moves against the stop).
Both end position stops are being readjusted automati-
cally.
Note:
This mode is suitable only with solid shaft connectors
and not for the Schanz special profile
3.2. Overview Off-Mode 2 – Standard for type GU
Upper end position about torque detection
(shutter moves against the stop) / set end position
bottom.
The upper end position is being readjusted automatical-
ly, the lower end position stays fix.
3.3. Overview Off-Mode 3
Set end position at the top / lower end position
about torque detection (shutter moves against the
stop)
The upper end position is being readjusted automatical-
ly, the lower end position stays fix.
Note:
This mode is suitable only with solid shaft connectors
and not for the Schanz special profile.
3.4. Overview Off-Mode 4
Set end position at the top / set end position bottom
An automatic readjustment does not take place.
Important! Adhere to the sequence, first the upper and then the lower float stop has to be
teached.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 10 von 16
3.5. Setting Off-Mode 1 (with test cable)
(Upper and lower end position about torque detection) - Automatic setting
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for
at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-Button,
until the lower end position is reached and the drive switches off
automatically shortly after the fastening of the end rod. Keep
pressing the button for at least 1 sec. longer after switching off.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.
3.6. Setting Off-Mode 1 (with micro switch and switch)
(Upper and lower end position about torque detection) - Automatic setting
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for
at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-Button,
until the lower end position is reached and the drive switches off
automatically shortly after the fastening of the end rod. Keep
pressing the button for at least 1 sec. longer after switching off.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 11 von 16
3.7. Setting Off-Mode 2 (with test cable) - Standard for type GU
(Upper end position about torque detection / set end position bottom)
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for
at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-button,
until the desired lower end position is reached.
Only for type GU with foamed slats:
- Hangers lie outside (right roller shutter) or at the window (left
rolling shutter) the spring has no pressure yet.
- Final rail is on the ground, light slits are closed, if they
exist.
Moving back or moving in short impulses is allowed.
30
Press both buttons simultaneously or the programming button* for ca. 2 sec. in order to learn the
lower position. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
The setting mode is exited.
*Depending on test cable model
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 12 von 16
3.8. Setting Off-Mode 2 (with micro switch or switch) - Standard for type GU
(Upper end position about torque detection / set end position bottom)
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the upper end position is reached and switches off auto-
matically about the torque detection. Keep pressing the button for
at least 1 sec. longer after switching off.
20
Setting the lower end position
Press DOWN-button,
until the desired lower end position is reached.
Only for type GU with foamed slats:
- Hangers lie outside (right roller shutter) or at the window (left
rolling shutter) the spring has no pressure yet.
- Final rail is on the ground, light slits are closed, if they
exist.
Moving back or moving in short impulses is allowed.
30
First press the micro switch and then the active button for ca. 2 sec. in order to learn the upper
position. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.
3.9. Setting Off-Mode 3 (with test cable)
(Set end position at the top / lower end position about torque detection)
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the shutter is in the desired upper end position. However it
has to stand stable within the guiding so that it does not leave it
when changing the winding behaviour.
Moving back or moving in short impulses is allowed.
20
Press both buttons simultaneously or the programming button* for ca. 2 sec. in order to learn the
upper position. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
*Depending on test cable model

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 13 von 16
Step No. Operation Note Check
30
Setting the lower end position
Press DOWN-Button,
until the lower end position is reached and the drive switches off,
keep pressing the button for at least 1 sec. longer after switching
off.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.
3.10. Setting Off-Mode 3 (with micro switch and switch)
(Set end position at the top / lower end position about torque detection)
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the shutter is in the desired upper end position. However it
has to stand stable within the guiding so that it does not leave it
when changing the winding behaviour.
Moving back or moving in short impulses is allowed.
20
First press the micro switch and then the active button for ca. 2 sec. in order to learn the upper
position. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
30
Setting the lower end position
Press DOWN-Button,
until the lower end position is reached and the drive switches off,
keep pressing the button for at least 1 sec. longer after switching
off.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 14 von 16
3.11. Setting Off-Mode 4 (with test cable)
(Set end Position at the top / set end position bottom)
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the shutter is in the desired upper end position. However it
has to stand stable within the guiding so that it does not leave it
when changing the winding behaviour.
Moving back or moving in short impulses is allowed.
20
Press both buttons simultaneously or the programming button* for ca. 2 sec. in order to learn the
upper position. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
*Depending on test cable model
30
Setting the lower end position
Press DOWN-button,
until the desired lower end position is reached.
Only for type GU with foamed slats:
- Hangers lie outside (right roller shutter) or at the window (left
rolling shutter) the spring has no pressure yet.
- Final rail is on the ground, light slits are closed, if they
exist.
Moving back or moving in short impulses is allowed.
40
Press both buttons simultaneously or the programming button for ca. 2 sec. in order to learn the
lower position. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
The setting mode is exited.
* Depending on test cable model
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 15 von 16
3.12. Setting Mode 4 (with micro-switch or switch)
(Set end position at the top / set end position bottom)
Step No. Operation Note Check
Important:
- First, there must always be taught the upper end position.
- If the drive switches off due to a malfunction (too fast increase of force) before reaching the endpoint, it has to be
set into learning mode again.
10
Setting the upper end position
Press UP-Button,
until the shutter is in the desired upper end position. However it
has to stand stable within the guiding so that it does not leave it
when changing the winding behaviour.
Moving back or moving in short impulses is allowed.
20
First press the micro switch and then the active button for ca. 2 sec. in order to learn the upper po-
sition. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
30
Setting the lower end position
Press DOWN-button,
until the desired lower end position is reached.
Only for type GU with foamed slats:
- Hangers lie outside (right roller shutter) or at the window (left
rolling shutter) the spring has no pressure yet.
- Final rail is on the ground, light slits are closed, if they
exist.
Moving back or moving in short impulses is allowed.
40
First press the micro switch and then the active button for ca. 2 sec. in order to learn the down po-
sition. As a learning confirmation it twitches twice.
Attention: Pressing the buttons not long enough the position will not be learned.
The setting mode is exited.
The learning of the forces happens automatically when running continuously from one end position to the other.
Perform this first test run only after completing all installation.

Einstellanleitung Elektronikmotor-Studio Star_englisch.docx Stand: 13.01.16 Seite 16 von 16
4. Copyright / References to this documentation
The copyright (copyright ©) for the present documentation is being kept by Schanz Rollladensysteme GmbH as well as partial-
ly by the suppliers of the sub vendor documentation.
The containing information is solely designed for the operating companies of our roller shutters. It may not be changed, extend-
ed, duplicated, saved on data linked institutions and spread without our written agreement nor should it be used for other pur-
poses. The containing information in this document makes no claim to be complete. We have done everything to reflect the con-
tent concerning our products to be correctly and up to date. However a warranty for the correctness of the documentation can-
not be given. Especially photographs and other images can contain components which do not belong to the standard scope of
delivery (options), or which have been changed in the meantime. Changes in connection with a further development as well as
the „state of technology“ are subject to alteration. Copyright © Schanz Rollladensysteme GmbH, 2015
Table of contents