Schippers MS Fancontrol Touch User manual

MS Fan Controller Touch
3409617
Title page Fancontroller 1

MS Fan Controller Touch
3409617
EN - MS Fancontroller Touch 3

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 2
Dear customer,
This manual contains all the necessary information to quickly master the operation of the MS Fancontrol
Touch. Please read this manual carefully before starting to operate the MS Fancontrol Touch. In this way,
you will learn how to operate the controller more easily.
Keep this manual in a safe place so that you can use it as a reference at all times. With a view to its
programme of continuous development and improvement, MS Schippers reserves the right to revise or
change its product range without prior notice. No rights can be derived from this manual.
EN - MS Fancontroller Touch 4

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 3
Table of contents
1Safety instructions and general warnings 4
1.1 General Warnings ___________________________________________________________________ 4
1.2 Safety warnings ____________________________________________________________________ 4
1.3 Wiring precautions __________________________________________________________________ 5
1.4 Deletion___________________________________________________________________________ 5
2Introduction 6
2.1 Possibilities of the MS Fancontrol Touch _________________________________________________ 6
2.2 Screen overview ____________________________________________________________________ 7
3User menus 9
3.1 24-hour overview ___________________________________________________________________ 9
3.2 Target temperature _________________________________________________________________ 9
3.3 Minimum ventilation _________________________________________________________________ 9
3.4 Maximum ventilation ________________________________________________________________ 9
3.5 Bandwidth________________________________________________________________________ 10
3.6 Ventilation stop____________________________________________________________________ 10
3.7 Switching the controller on or off _____________________________________________________ 10
3.8 Restore factory value _______________________________________________________________ 10
3.9 System time ______________________________________________________________________ 11
3.10 System info_______________________________________________________________________ 11
3.11 QR-code manual___________________________________________________________________ 11
4Alarm overview 12
5Printed circuit board overview 13
5.1 Front pcb ________________________________________________________________________ 13
5.2 Bottom pbc _______________________________________________________________________ 14
6Wiring diagram 15
6.1 Hirschmann connectors _____________________________________________________________ 15
6.2 Temperature sensor & mains voltage __________________________________________________ 15
6.3 Alarms (Optional) __________________________________________________________________ 16
7Technical specifications 17
EN - MS Fancontroller Touch 5

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 4
1Safety instructions and general warnings
Read, understand and carefully follow all warnings and instructions of MS Schippers to use our products
safely. These warnings and instructions can be found on the equipment, in manuals, in brochures, on our
website or by contacting us. The selection and application of MS Schippers products remains the
responsibility of the installer or end user of the equipment. MS Schippers accepts no responsibility for the
way its products are applied. All MS Schippers products must be delivered to the end user with appropriate
warnings and instructions regarding safe use and operation. MS Schippers does not accept any liability for
personal injury, material damage, losses or claims as a result of incorrect application of its products.
1.1 General Warnings
⚠WARNING
Read and understand all warnings and instructions provided by MS Schippers before
installing, using or maintaining any of our products.
All work may only be carried out by qualified personnel.
The product may only be placed, used or stored in places that are inaccessible to children.
Handle the product with care; impacts, shocks or falls, even from a low height, can
damage the product.
Do not expose the product to direct sunlight, high heat or cold.
Always check all settings after installation to make sure they are working correctly.
Do not use running water to clean your computer. The computer is splashproof, not
waterproof!
1.2 Safety warnings
⚠WARNING
Do not wear metal or conductive materials, such as jewellery (necklaces, bracelets, rings,
etc.) when installing or servicing electrical parts or components.
Always switch off the power before opening the enclosure.
Never remove components or wires from electronic boards when the device is turned on.
Use the correct mains voltage.
Make sure that all clamp screws are correctly tightened.
Always use cable glands when installing cables in the controller.
After installation, unused cable glands or blind holes must be sealed to prevent water,
dust and other substances from entering the regulator.
If you have reason to believe that the device can no longer be used safely, disconnect it
immediately and ensure that it is not operated inadvertently.
EN - MS Fancontroller Touch 6

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 5
1.3 Wiring precautions
⚠WARNING
Always use a shielded cable for all low-voltage connections.
Always use a shielded cable for all high voltage connections.
For communication connections, always use a twisted-pair shielded cable.
Do not connect the shielding of low-voltage connections to the earthing block (PE).
Do not connect the shielding of communication links to the earthing block (PE).
The maximum length of the communication link shall not exceed 1200 metres.
Disconnect high-voltage connections from low-voltage connections and/or
communication connections to prevent interference.
If inductive loads such as magnetic switches etc. are connected to the equipment,
Schippers advises to disconnect these loads by placing an RC filter (100ohm + 100nF)
in parallel.
1.4 Deletion
Electronic devices are recyclable and should not be disposed of as household waste. At the end
of its service life, dispose of the product in accordance with the applicable legal regulations.
EN - MS Fancontroller Touch 7

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 6
2Introduction
2.1 Possibilities of the MS Fancontrol Touch
The MS Fancontrol Touch is specially designed for controlling fans in a cattle shed. The controller has
the following features:
Measurement of room temperature
Graph with measurements of today and yesterday
Control of 1 to a maximum of 10 ventilators (2 groups of maximum 5 ventilators per group).
Ventilation stop below a set temperature
Minimum and maximum temperature alarm
Alarm on defective room sensor
External alarm input
EN - MS Fancontroller Touch 8

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 7
2.2 Screen overview
Figure 1: MS Fancontrol Touch screen layout
A: The alarm bell icon is displayed here. If no alarm is active, this icon is gray
. If an alarm is active, the icon turns red. The alarm bell icon is orange
when alarms have been silenced but not yet resolved.
B: On the right side of the screen, you can swipe up and down through all the control icons.
By pressing the icon, you can enter your desired settings (see Figure 2: Change settings). The set values
are displayed to the right of the corresponding icon.
C:
1 The set point value in °C.
2 The measured room temperature in °C.
3 The current state of ventilation.
4 The minimum to maximum ventilation set.
EN - MS Fancontroller Touch 9

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 8
G
Figure 2: Adjusting settings
D: If you press any of the control icons, the displayed settings bar will be visible. You
can adjust the controls settings by pressing "+" to increase and
"-" to lower. Press "OK" as soon as the desired setting is entered.
Remark: If you want to cancel a newly entered value, press the left half of the screen. The settings bar
closes and the value is reset to the previous setting.
EN - MS Fancontroller Touch 10

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 9
3User menus
This chapter discusses all settings in the user menu.
3.1 24-hour overview
24 uur grafiek Open grafiek
This opens a 24-hour temperature and ventilation graph. Different graphs can be selected with the icons on
the right side of the graph. The graph can be closed by pressing the 'X' icon in the upper right corner of the
graph.
Yesterday's measurements are shown with a thin orange graph line. A thicker blue graph line shows today’s
measurements to the present time.
3.2 Target temperature
Streef-
temperatuur °C
Input range: 0.0°C - 50.0°C [factory value: 20°C]
Here you can set the desired temperature for the department.
3.3 Minimum ventilation
Minimum
ventilatie %
Input range: 0% - 100% [factory value: 10%]
Here you can set the desired minimum ventilation. This is the ventilation rate when the room temperature is
equal to or lower than the set temperature.
3.4 Maximum ventilation
Maximum
ventilatie %
Input range: 5% - 100% [factory value: 100%]
Here you can set the desired maximum ventilation. This is the ventilation rate when the room temperature
has reached the end of the bandwidth.
EN - MS Fancontroller Touch 11

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 10
3.5 Bandwidth
Bandbreedte °C
Input range: 1.0°C - 20.0°C [factory value: 5.0°C]
Here you can set the desired temperature range in which the ventilation is increased from minimum to
maximum.
3.6 Ventilation stop
Ventilatie stop
offset °C
Input range: -10.0°C - 10.0°C [factory value: -10.0°C]
Temperature deviation with respect to the set temperature at which the ventilation stop is activated. The
ventilation stop activates relay 2 with a potential-free changeover contact.
3.7 Switching the controller on or off
Regelaar
in-/uitschakelen Aan/Uit
Input range: On or off
When the controller is turned on, the background colour is blue. All functionality is enabled in this situation.
When the controller is switched off, the background colour changes to orange. When switched off, the
ventilation stop is active and the analogue fan signal is 0V. The alarm function remains active.
3.8 Restore factory value
Herstel naar
fabriekswaarde Open Pop-up
This function resets all settings to their default values. If clicked, a pop-up appears to confirm this action. If
the controller was switched off (see above), this function will switch the controller back on again.
EN - MS Fancontroller Touch 12

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 11
3.9 System time
Systeem tijd uu:mm
Input range: 00:00 - 23:59 hrs:mm
Here you set the current time. This time is needed to display the 24 hour graph correctly.
3.10 System info
Systeem info Open Pop-up
Opens a pop-up with the system information. The version is displayed as Vxx.yy.zz where xx.yy is the main
release number and zz is the revision number.
3.11 QR-code manual
Opens a QR code with a hyperlink to this manual for digital download. The code can be scanned by phone or
any mobile device.
QR-code
handleiding Open QR-code
EN - MS Fancontroller Touch 13

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 12
4Alarm overview
This chapter discusses the alarms that the MS Fancontrol Touch can display.
No alarms are active
If no alarms are active, the alarm bell icon is grey.
One or more alarms are active
If one or more alarms are active, the alarm bell icon flashes with a red background, switching between the
alarm bell icon and the alarms that are active.
Also, the alarm relay will be activated.
Resolve or stop an alarm
To deactivate an alarm, simply press the alarm icon that is visible on the home screen.
The alarm relay will be activated,
When the alarm is resolved, the alarm icon will automatically appear gray. If the alarm is not resolved, the
alarm bell icon turns orange, indicating that the alarm has been silenced. If the MS Fancontrol Touch detects
that the alarm is still active within 5 minutes, or if a new alarm situation occurs, the display switches back to
the active alarm bell icon. The alarm relay will activated.
Remark: The various alarm icons can only be displayed if the corresponding control is active and an alarm
occurs in relation to that control.
No alarms: There are no alarms at the moment.
Alarm alert: One or more alarms are active, but are suppressed for 5 minutes.
Alarm: One or more alarms are active and the alarm relay has been activated.
Minimum temperature alarm: The measured room temperature is equal to or
below the set minimum alarm limit.
Maximum temperature alarm: The measured room temperature has risen to
equal to or above the set maximum alarm limit.
Sensor defect alarm: The measured temperature is out of range (lower than -
60°C or higher than 130°C).
IO alert: The communication between the front pbc and the bottom pbc has
been interrupted
EN - MS Fancontroller Touch 14

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 13
5Printed circuit board overview
This chapter shows the print overview of the MS Fancontrol Touch.
5.1 Front pcb
LEDs voor bodem print communicatie (IO)
Tx: Transmit
Rx: Receive
MicroSD kaart ingang
SW1: knop 1
RESET: reset knop
RUN LED
ADRESS LED
Serie
nummer
Spannings LED
Remark: The LEDs for communication at the bottom (IO) indicate the communication between the PCB on
the front panel and the PCB on the bottom.
EN - MS Fancontroller Touch 15

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 14
5.2 Bottom pbc
24V LED
LEDs voor frontprint communicatie (IO)
TxD: Transmit
RxD: Receive
SW1: Knop 1
RESET: Reset knop
ADDRESS LED
RUN LED
POWER LED
Remark: The LEDs for communication at the bottom (IO) indicate the communication between the PCB on
the front panel and the PCB on the bottom.
EN - MS Fancontroller Touch 16

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 15
6Wiring diagram
6.1 Hirschmann connectors
6.2 Temperature sensor & mains voltage
EN - MS Fancontroller Touch 17

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 16
6.3 Alarms (Optional)
Important: Connect alarm input when not in use!
EN - MS Fancontroller Touch 18

MS_FANCONTROL_TOUCH_GEBRUIKERSHANDLEIDING Page 17
7Technical specifications
General
Dimensions (external)
Enclosure:
Connections
Ambient temperature:
: 204x229x116mm (depth x width x height)
: Plastic IP54
: Through Hirschmann Connectors and fixed cabling
: 0 - 45˚C no direct sunlight or radiation from heat source
Supply voltage
Mains frequency
Energy consumption
: 110 –240Vac
: 50/60Hz
: Max. 20 Watt
24Vdc output
12Vdc output
: Max. 125mA
: Max. 250mA
Analogue inputs
Analogue input 1
Analogue input 2
Analogue input 3
Measuring range temperature inputs
: Room temperature sensor (type: PT3000)
0-10V / 10K input impedance (1mA)
: No function
: No function
: -70.0˚C to 130.0˚C
Digital inputs
Digital input 1
Digital input 2
: No function
: External alarm (NC)
NPN sensor / max. 250Hz; no-load voltage 24Vdc
(Transfer if not used!)
Analogue Outputs
Analogue output 1
Analogue output 2
FAN output
: No function
: No function
: 0-10V output to frequency inverter
Relay outputs
Relay 1
Relay 2
Alarm relay
: No function
: Ventilation stop
: Max. 24Vac/dc 2Amp. potential free
EN - MS Fancontroller Touch 19

MS Fancontroller Touch
3409617
NL - MS Fancontroller Touch 20
This manual suits for next models
1
Table of contents
Languages:
Popular Controllers manuals by other brands

LR
LR SPG501 006 Operation manual

Hitachi
Hitachi Eco Compact PC-ARC-A Installation & maintenance manual

AudioCodes
AudioCodes Mediant 800C Quick setup guide

Advantech
Advantech Celeron M Universal Network Controller with PC/104 Extension... user manual

ZPA Pecky, a.s.
ZPA Pecky, a.s. MODACT MOA installation instructions

SICK
SICK Flexi Soft operating instructions