2. Monitor Installation Mode Configuration
The A1IPMW and A1IPMB can be used on both Villa and Apartment systems, but they require to be config-
ured into the correct “Build” mode.
Ensure the monitor has been powered up, using either the DC12V input [1] or PoE Input [2].
One the monitor has fully initialised click on “System Settings”, and then enter the code “31415” and press
“OK”.
• Select “Villa” for Single Way Systems
• Select “Build” for Multi Way Systems.
Then adjust the Device type using the onscreen arrows, and then press “OK”.
3. Villa Monitor Installation
• if a monitor is being used with Villa Outdoor Station that is at factory default, then the Monitor will not
need configuring, and will operate once fully initialised.
• If the monitor is to be used with a configured Villa Outdoor Station, then do the following:
1. Once the monitor has fully initialised; Click on “System Settings”,
and then enter the code “666666” and press “OK”.
2. Then select “Extension”, and then enter the Rooms Extension [01~06]
Note:
Ensure there is always a monitor with the Extension “01” on the system.
Ensure Section 2 has been completed, to ensure the monitor is set to the Villa Mode.
A Maximum of 6 monitors on a single system is recommended.
If more are required, please contact ESP Technical for further information.
01Ext.
Please enter an extension number:
Extension
4. Multi Monitor Installation
One the monitor has fully initialised and section 2 has been completed; click on “System Settings”, and then
enter the code “666666” and press “OK”.
Then select “Extension”, and then enter the Rooms Extension.
EX. 1st Building, Room 0005, Extension 1
01Bd.0005Room01Ext.
Note:
Ensure there is always a monitor with the Extension “01” on the system.
A Maximum of 200 addresses on a single system is recommended.
If more are required, please contact ESP Technical for further information.
01Bd.0001Room01Ext.
Please enter an extension number:
Extension