Screen Technics Interfit Projector Lift User manual

Interfit PROJECTOR LIFT Models C, D and F Type
ThankyouforpurchasingaScreenTechnicsAVLifter
andpleaseensuretoreadtheinstructionfullybefore
proceedingtoinstalltheunit.
GeneralAdvice
TheInterfitAVLifterisafullyintegratedunitthatisdesignedtobeinstalledabovetheceilinglineoftheroomandutilises
bottomceilingedgetrimpiecestocreateaneatfinishagainsttheceilingmaterialcut‐out.
Noplasterorpainttradesarerequiredforthisstandardinstallation.
Allelectricalandcontrolequipmentiscontainedintheceilingspace.Astandard3pinGPOforpowersupplyisrequired.
Reviewthecut‐outdimensionfactsheetattachedtothetoplidoftheunit,asmodelsizesvarythroughouttherange.
Beforeproceedingensurethatyouhaveenoughin‐ceilingheighttofittheunit.Andthatyourmodellifterwill
accommodatetheprojectorthatisspecifiedfortheproject.
MakesureyouhavereviewedtheLensThrowDistanceChartprovidedwiththeprojectorsothattheLifterwillbethe
correctdistancefromtheprojectionscreenandtoallowforanysidewayslensoff‐settoachieveaperfectresult.
InstallationAdvice
HavingdecidedonthepositionoftheLifteryoumustnowcuttheceilingmaterialtothestatedcut‐outdimension.Werecommend
thatyoudividethecut‐outintwoandremoveonehalfatatimetopreventtornedges.
Everyaboveceilingenvironmentisuniqueandthereforethereisnosingularapproachtosecuringtheunit
withintheceilingspace.Followingaresomeacceptedinstallpractices:
PleaseNote:Iftheceilingenvironmentisgoingtobesealedwithoutman‐holeaccessupintotheroof,thenfor
laterserviceremoval,itisimportanttousetheelongatedverticalslotsonthelowerhalfoftheframeuprights
tosecurethesuppliedanglebrackets.Thiswillallow(withsomedifficulty)removalofthedevicefrombelowif
mechanicalfailureoccurs.
ChainandTurnbuckle
Securethechaintoasuitablestructure,suchasoverheadtimberbeams,ordyna‐boltedtoan
overheadconcreteslab.
Aminimumof4pointstosecurethechainisrequiredanditistheinstallersresponsibilityto
ensurethechainturnbucklesystemchosenisstrongenoughforthesafeinstallationofthe
unit.
Nowraisetheunitintotheceiling,holdinpositionfrombelowwhileasecondperson
securestheotherendofthechaintothelifterusingthesuppliedanglebracketsandtighten
theturnbucklestilltheunitsceilingedgetrimsarefirmlypressingagainsttheundersideof
theceilingmaterial.
Lockofftheturnbuckles.

All‐threadBrookerRod
Secure4xbrookerrodstoasuitableoverheadstructurewithaproprietaryloxinsystem
designedtoacceptthreadedrod.
Spacearoundtheoutsidecornerdimensionsoftheunit.
Windasetofnutsuptherodsabovetheinstallationheightandtheninserttherodsthrough
thesuppliedanglebrackets,nowattachedtothelifterunit.
Nowwindonasetofnutsunderthebrackettilltheceilingedgetrimsarefirmlypressing
againsttheundersideoftheceilingmaterial,thenwindtheuppernutsdownontotheangle
bracketstolockoffunit.
Installationsarebestachievedbyhaveaccessintotheroofspacebutthisisnotalwayspossible,andintheseinstancesweadvise
thefollowingpractices:
InstallingfromBeneaththeCeilingLine
Connectpowerinasafemannertotheunitandsupporttheliftersoyoucanmotortheprojectorcagelowerthanthe
ceilingedgetrimsandyouwillsee6Allenkeyboltsholdingthecageassemblytotheunit.Removetheseandsetaside
thecageunit.
Removetheprojectormountingplatebyremovingthe2Allenkeyboltsatthefrontundersideofplateandpullthe
forwardtoremovefromthelifterassembly.
Motortheremainingassemblytothefullupposition(watchoutforyourfingers…)andyounowhaveroomtoaccess
theinterioroftheunit.
Inspectthe8installationslotsrunningupthecornerframeuprights.Theseareusedtosecurethedevicetosome
suitablestructurefrombelowtheceilingline.
Eitheraddsometimberintheceilingalongtwosidestocoachboltintoplaceorsuspendfromthreadedrodorsome
suitableanglebrackets.
Raisetheunitintotheceiling,fitthescrewsorbolts(asappropriatetoselectedmethod)andapplyupwardpressureto
theunitsotheceilingedgetrimsarepressedfirmlyagainsttheundersideoftheceilingmaterialandtightenoffthe
screwsorbolts.
Motordownthemechanismandrefittheprojectorplateandcageassembly.
PleaseNote:Whenutilisingtheabovemethodofinstallationfrombeneaththeceiling,itisbesttouseamethodoffixingtoany
structurethatwillallowyouatalatterdatetoremovethelifterforanyfutureservicingissues,withouttheneedtobreakintothe
ceiling–pleaseconsiderthisissuebeforedecidingonthebestinstallationmethod.
ProjectorInstallation
Thisunitcomeswithablankprojectormountingplatethatrequiresyoutomarkoutthe
mountingholesanddrillwhereappropriate.
Removaloftheplatefordrillingandfittingisachievedbyundoingthe2offAllenkeybolts
alongthefrontundersideedgeofthemountingplate,andpullingtheplateforward.
These2offAllenkeyboltswilllaterbetheadjustmentmethodusedforyaworsideto
sidealignmentoftheprojector,withthethreadedadjustmentwinderusedforpitchorup
anddownadjustmentofprojector.
Foreaseofadjustmentandcablefittingtheceilingplatecanberemovedfromthe
projectorshroudassemblybyundoingthe6xAllenkeyboltsthatsurroundtheceiling
platefromtheoutsideperimeteroftheshroud,asbelow.

CableManagementforUnitswith200mmto600mmTravel
Therearoftheprojectormountingplatehasacablemanagementaccessholethatallows
youtoruncablesthroughandintothecablemanagementchannel.
Layouttherequiredcablesandlockthemintopositionutilisingcabletiesinthesmall
regularholesrunningupthechannel.
Besuretoallowenoughslackinthecablesateveryhingedelbowpointsothecablesdon’t
interferewiththetravelofthelifter.
Exitcablesthroughthesuppliedopeningontopoftheunit.
CableManagementforUnitsover600mmTravel
Onunitswithlongertravelasecondtypeofcablemanagementisrequired.
Abovetheprojectormountingpositionisanaccessholeforthecablesandvariouscabletie
mountingholes,pleaseseethepicturebelowthistext.
Thisallowsthecablestorunupthecentrallymountedcablerunplanes,tothemidsection
oftheplane,wherethecabletieholescease.
Thisisthepointwhereyoustopandruntothefrontoftheuppercablerunplane,leaving
enoughslackintheinstallationforsocablesdon’tpinchorstretch.
Control
ConnectControlModule–Standard
AftertheinstallationoftheInterfitProjectorLiftiscompleted,plugintoastandardpowerpointandturnon.
TheAVLiftcanbeoperatedinthreeways:
2ChannelInfraRedRemoteControl‐supplied
ImpulsewallSwitch–Up&Down(suppliedbyothers)
DryContactClosure–SPDT(SinglePoleDoubleThrow),forcontrolsystemconnection.

Point1TheAVLiftcomeswiredwithastandard3pinpowerplugwhichissuitableforAustralianandNewZealandGPO’s(general
poweroutlet).
Point2Infra‐RedRemoteControl
TheAVLiftispackagedwitha2channelInfraRedTransmitteranda
300mmlongIRSensor,forconnectiontotheConnectModule.
PositiontheIRSensorEyewithdoublesidedtapeoraUPin,sothatitcan
beseenfromwhereyouwishtooperatetheAVLift,andusetheupand
downbuttonsonthetransmitteronchannels2onlytooperatetheunit.
Point3a‐ImpulseWallSwitch(suppliedSeparately‐ItemNumber3500998).
TheConnectModuleequippedProjectorLiftercanalsohavesimplewallswitchoperation,althoughduetointeriordécorchoicesthe
actualswitchitselfisnotsuppliedwiththeAVLiftandneedstobesourced.
Youwillneedtoconnecttheimpulsewallswitchtothedrycontactclosureinput,itprovideslocalcontrolofyourProjectorLifter
Point3b‐DryContactClosure
ThisistheindustrystandardmethodofswitchinganAVLifterviaaBuildingControlSystem.
ItisoperatedonaSPDT(singlepoledoublethrow)switchingstandardwithanOpen,CloseandCommon
inputport.ItutilisesthesameconnectionastheabovedescribedImpulseWallSwitch.
rcv
I
R
LED UCD
Connect Network
InOut
Contact Close
Input
IR Receiver
Input
Connect Network
In
Out
Next Connect Module
Maximum 9 Modules
UpDown
Momentary Contact Close
rcv
I
R
M
Motor Output
240 V
Input
IEC
Socket
1 2 3 4
Motor Wiring
Pin 1 - Brown Screen Down
Pin 2 - Black Screen Up
Pin 3 - Yellow/Green Earth
Pin 4 - Blue Neutral
Infra Red
Receiver
RJ12 Connector
6 Core wired
straight through
In
Out
4
1
2
3 5

Point4a–InputfromOtherConnectProducts(ProjectionScreen)
TheLeftRJ11Inputallowsyoutodaisychainfromanotherconnectmoduleeg:ElectricinemaProjectionScreenandhaveboth
productscontrolledviatheIRremotecontrol
Point4b–OutputtoOtherConnectProducts
TheRightRJ11outputallowsyoutodaisychaintoanotherconnectmoduleeg:ElectricinemaProjectionScreenandhaveboth
productscontrolledviatheIRremotecontrol.
Note:ConnectionmustbefromtherightRJ11outputtotheleftRJ11Inputupto9ModulesinTotal
Point5–ConnectionofLowVoltageTriggerModule(NotSupplied)
TheLeftRJ11InputallowsyoutoconnecttheLowVoltageTriggerModule,themodulerequires5V–24VDCtooperate.WhenDC
voltageissuppliedtoLowVoltageTriggerfromaprojectororcontrolsystemtheprojectorliftwilllowerandwhennoDCvoltageis
presenttheprojectorliftwillraise.
Note:TheLowVoltageTriggermustbeconnectedtotheLeftRJ11using6CoreFlatCabletofirstConnectModule.
Onceyouhavechosenyourswitchingmethodensurethatyourefitthelidofthecontrolboxbeforeapplyingmainspowertothe
ProjectorLifter.
Right RJ11 Output
to connect modules Left RJ11 Input from
previous module
5V – 24V
DC Input

LimitSettingforallInterfitProjectorLiftswithConnect
exceptCW&CXrange
Thefollowinginstructionsarefortheadjustmentofthelimitswitchesthataltertheupper
andlowerstoppositionsonInterfitProjectorLiftswith300mmoftravelorlonger
WhereareTheLimitSwitches?
Atthesameendtothepowercable(RightHandSide).
Oneswitchisaccessibleeitherwhentheliftisdownor
whenthesidecoverisremoved
WhichSwitchisforUpandDown?
Downswitch–Theoneclosesttotherearofthelifter
Upswitch–Theoneclosesttothefrontofthelifter
WhatToolsdoINeed?
Eitherthelimitsettingtool(supplied),anarrowtipscrewdriver(lessthan4mm)ora4mmAllenKey
WhichWaydoITurntheSwitch?
Clockwisealwaysincreasestheamountofrotation(travel)ofthemotor.
Anti‐clockwisealwaysreducestheamountofrotation(travel)ofthemotor.
Sopicktheswitchresponsibleforthelimitposition,upordown.Clockwiseturningoftheswitchwill
alwaysletthemotortravelfurtherinthatdirection.Anti‐clockwiseturningoftheswitchwilllessen
theamountoftravelinthatdirection.
CanIadjusttheswitchwhilethelifterissittingonthelimit‐i.e.fullyupordown?
Clockwiseadjustment?–YES.Butitisbettertobackthelifterawayfromthelimitandthenadjust
Anti‐clockwiseadjustment?‐NOyouwilldamagethemicroswitchifyouturnitanti‐clockwisewhile
thelifterissittingonthelimit.Neverattemptthis.Youmustbackthelifterawayfromthelimit
beforeadjustment.Afteradjustmentyouwillneedtorunthelifterupanddowntopickupthenew
limit
WillIvoidtheproductwarrantyifIdamagethelifterwhilstmakingtheseadjustments?
Yesitispossible.

LimitSettingAdjustmentforInterfitProjectorLiftsModels
143030CW‐143030CX‐143060CW‐143060CX
143090CW–143090CX
Thefollowinginstructionsarefortheadjustmentofthelimitswitchesthatalter
theupperandlowerstoppositionsonInterfitProjectorLiftswith300mmof
travelorlonger
WhereareTheLimitSwitches?
Atthesameendtothepowercable(RightHandSide).
Oneswitchisaccessibleeitherwhentheliftisdownor
whenthesidecoverisremoved
WhichSwitchisforUpandDown?
Downswitch–Theoneclosesttotherearofthelifter
Upswitch–Theoneclosesttothefrontofthelifter
WhatToolsdoINeed?
Eitherthelimitsettingtool(supplied),anarrowtipscrewdriver(lessthan4mm)ora4mmAllenKey
WhichWaydoITurntheSwitch?
Clockwisealwaysdecreasestheamountofrotation(travel)ofthemotor.
Anti‐clockwisealwaysincreasestheamountofrotation(travel)ofthemotor.
Sopicktheswitchresponsibleforthelimitposition,upordown.Clockwiseturningoftheswitchwillalways
letthemotortravellessinthatdirection.Anti‐clockwiseturningoftheswitchwillincreasetheamountof
travelinthatdirection.
CanIadjusttheswitchwhilethelifterissittingonthelimit‐i.e.fullyupordown?
AntiClockwiseadjustment?–YES.Butitisbettertobackthelifterawayfromthelimitandthenadjust
Clockwiseadjustment?‐NOyouwilldamagethemicroswitchifyouturnitanti‐clockwisewhilethelifteris
sittingonthelimit.Neverattemptthis.Youmustbackthelifterawayfromthelimitbeforeadjustment.After
adjustmentyouwillneedtorunthelifterupanddowntopickupthenewlimit
WillIvoidtheproductwarrantyifIdamagethelifterwhilstmakingtheseadjustments?
Yesitispossible.
Shouldyouhaveanyquestionsregardingtheinstallationofourproducts
pleasecalloursalesdeskon+61248692100forassistance