SCUDO 600 User manual

SCUDO Automatic Voltage Regulator Quick Guide V.1.0
Introduction
Thank you for purchasing SCUDO product. This series is designed to automatically
maintain a constant voltage level to protect sensitive electronics from brownouts
and overvoltages. With its fashionable and flexible cabinet, it can be installed on a
desk or wall without causing an unsightly or unprofessional image, and will perfectly
utilize a limited working environment. This series offers one-step boost and one-step
buck stabilizer to continuously supply a clean power source to its connected equipment.
1
2Product Overview
3Installation & Initial Startup
Inspection
Remove the unit from the shipping package and inspect it for damage
that may occurred during transportation. Notify the carrier and place
of purchase if any damage is found.
Placement & Storage Conditions
Install the unit in a protected area that is free of excessive dust and has adequate
air flow. Please place the UPS away from other units at least 2.5cm to avoid
interference. Do NOT block the top or side air vents on the unit.
Do not operation the unit in an environment where the ambient temperature or
humidity is outside the limits listed in the specifications. Operate the unit in an
environment free of excessive dust, mechanical vibration, inflammable gases and
explosive or corrosive atmospheres.
Connect to the Wall Outlet
Plug the input power cord of the unit to the wall outlet.
Connect the Loads
Plug in the loads to output receptacles of the unit and switch the unit “ON” by pressing
the side panel ON/OFF switch to “ON” position. Then the connected devices will be
powered.
Connect Modem/Phone for Surge Protection
(Only for the model with RJ-11)
Connect a single modem/phone line into surge-protected “IN” outlet on the unit.
Connect from “OUT” outlet to the computer with phone line cable.
Turn On/Off the Unit
Turn on the unit by pressing the power switch to “ON” (l)position. This switch may be
used as the master ON/OFF switch for all connected devices.
1
3
2
45
6
7
Output receptacles (for connecting equipment)
AC input Power switch
Circuit breaker Power LED
Modem/phone surge protection Boost/Buck LED
1
2
3
4
5
6
7
2.5cm
(1 inch)
Wall Mount the Unit
The unit can be mounted to a wall surface. Please follow below steps:
1. Use tape to hold this page in place against the wall.
2. Use a sharp nail to puncture the center of the two holes to mark the wall.
(see below chart 1)
3. Mount the unit by positioning the key-hole slots over the mounting
nails. (see chart 2)
128 mm
Chart 1 Chart 2
Wall

Trouble Shooting
6
Before using the product, please be sure that Power LED is on. If the Power LED is
not on, please check the following steps:
1. Check if the mains is normal.
2. Check if the power cord is connected firmly.
3. Check if the connected devices are connected to the unit firmly.
4. Check if the unit is turned on.
Use the below table to solve the minor problems.
Specifications
7
Important Safety Warning
4
CAUTION: The total power consumption of all equipment plugged into the
voltage regulator must not exceed its capacity*. A total load in excess
of its capacity* will cause the fuse to fault (blow).
*For the capacity of unit, please check the specifications.
The voltage regulator is designed for use with voltage sensitive equipment
such as: a home computer, monitor, inkjet printer, scanner or fax. It is also
designed for use with home electronics equipment such as television,
stereos, CD players, VCRs, and DVD players, data processing equipment,
modems, typewriters, calculators, and telephone equipment.
Appliances not suitable for use with the product are items such as freezers,
power tools, air conditioners, dehumidifiers, blenders, or any device that
employs an AC motor for operation. Not for use with small fuel generators.
Also excluded are life sustaining equipment.
When use the voltage regulator with an Interruptible Power Supply (UPS),
connect the UPS to the output of this product, then connect the product
to the wall outlet.
Problem Possible Cause Solutions
Circuit breaker
is “tripped”.
The unit is
turned off
automatically
and the Power
LED is not lit.
The unit is overload.
The unit is over-
heated. It’s internal
protected function.
Remove some loads
first. Reset the circuit
breaker by pressing the
button again.
Remove some loads and
wait until the unit is cool.
Then turn on the unit
again.
If any abnormal situations occur that are not listed above, please call
service people immediately.
Model 600 1000 1200
CAPACITY
INPUT
Voltage
Voltage Range
Frequency
OUTPUT
Voltage Regulation
AVR
INDICATORS
Power LED
AVR LED
PROTECTION
Comprehensive
Protection
PHYSICAL
Dimension (DxWxH mm)
Net Weight (kgs)
ENVIRONMENT
Humidity
Nosie Level
600 VA / 360 W 1000 VA / 600 W 1200 VA / 720 W
166 x 161 x 86.7
1.7 2.0 2.1
220 VAC
180 - 264 VAC
50 Hz
+/-12%
+/- 8%
Green lighting
Red lighting
Short circuit, overload, and over-temperature
protection
0-90 % RH @ 0-40 C (non-condensing)
Less than 40 dB
To safely operate this voltage regulator, please read and follow all
instructions carefully. Read this manual thoroughly before attempting to
unpack, install, or operate. You may keep this quick guide for further
reference.
CAUTION: The unit is designed only for use under the 50 Hz input frequency and
pure sine wave environment. Any other input frequency or wave form will effect the
voltage range and load capability.
CAUTION: Please DO NOT connect the unit to the environment with direct voltage
or simulated sine wave.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and
humidity controlled indoor area free of conductive contaminants. (See the
specifications for the acceptable temperature and humidity range.)
5Applications
This manual suits for next models
2