1
Getting to Know Your SecureStart™
Prepare Your SecureStart™ Before First Use
STEP 1: Upon purchase, disconnect the external 13-cell D size alkaline battery pack
that is connected with a wire connector to the SecureStart™ by pulling the connecting
wire out. Discard this 13-cell alkaline battery pack.
STEP 2: Insert and connect the jumper link into the unit. Mount the jumper cover
plate with the screw. The jumper link is to connect the built-in NiMH battery to replace
the discarded 13 D-size cell alkaline battery for backup purpose.
Note: The 13 D-size cell alkaline battery is for backing up the SecureStart™ Lead Acid
battery during storage before sales for limited period only.
WARNING: DO NOT allow the cable clamps to TOUCH each other! The
cable clamps carry electrical current at all times. If they touch each other, severe
sparks may cause personal injury and battery explosion. Use only the wall
adaptor supplied with your SecureStart™ for charging. To avoid damage, do not
use any other chargers or apply any other charging methods.
!
Cable Clamps
Fuel-Gauge
Indicator
Fuel-Gauge
Switch
DC Charging
Socket
13 cells D size Alkaline Battery
Pack with connector wire
Wall Adaptor
Input: 100-240Vac 50/60Hz
auto switching
Output: 24V DC 2.5Amp
Selector switch
Jumper link cover
13 cells D size alkaline
battery input jack

2
STEP 3: Charge your SecureStart™ by using wall adaptor immediately.
Make sure that the selector switch is in “OFF” position. Only at this position, the
SecureStart™ can be charged.
Plug the DC jack of the adaptor into the DC charging socket on SecureStart™.
Your SecureStart™ will begin charging upon switching on the wall adaptor.
Minimum 4 hours or permanently plugged-in charging. To maximize
SecureStart™ performance, permanent plugged-in charging is recommended.
On-Charge indication:
RED : FAST Charging
GREEN : SLOW Charging (ready)
IMPORTANT: The selector switch of the SecureStartTM must always be switched
to “OFF” position when it is not used for cranking.
When to Recharge Your SecureStart™
It is mandatory to recharge SecureStart™ immediately after used. SecureStart™ is
incorporated with smart charging system as to prevent overcharging. It is recommended
that the SecureStart™ be plugged in when not in used.
To determine whether the unit is ready to use simply press and hold the fuel-gauge switch to
observe the LED color on the indicator.
NOTE: The selector switch must be at “OFF” position.
Fuel gauge indication:
•RED : Immediately recharge your SecureStart™
•GREEN : Ready to jump-start
•As fuel gauge traces the battery voltage, the indication may not be accurate right after the
unit is unplugged from the charging. Please check the fuel gauge after 30 minutes rest
from charging.
Recommended to plug in the wall adaptor when not in used.
It is recommended to store your SecureStart™ in a cool, dry location to maximize its
performance.
Failure to follow the charging instructions may shorten your unit’s service life.
For charging, plug the jack into the socket here
3
Jump-Starting Your Vehicle
IMPORTANT: Check the vehicle cranking system voltage first (12V or 24V)
before use.
1. Turn vehicle ignition switch to OFF before accessing battery in vehicle or connecting cable
clamps to vehicle battery.
2. Open hood of vehicle and position SecureStart™ away from fan blades, belts, pulleys or any
other moving parts.
3. Make sure that the selector switch of the SecureStart™ is at ‘OFF’ position.
4. Connect the Red positive (+) cable clamp first to the vehicle battery’s positive (+) terminal.
Rotate clamp slightly to ensure a good connection.
5. Connect the Black negative (-) cable clamp last to vehicle chassis, engine block, hanging
hook or other unpainted, non-moving metal surface that is away from the vehicle battery.
Rotate clamp slightly to ensure a good connection.
6. Turn the selector-switch on the SecureStart™ to the vehicle cranking system voltage.
IMPORTANT: Turn to the wrong voltage will damage the vehicle electrical system.
7. Turn vehicle ignition switch and start the engine.
8. If you intend to crank another engine immediately it is recommended to leave the cable
clamps of SecureStart™ connected for 3 minutes to allow a top up charge from the alternator
of the idling vehicle.
9. Turn the selector switch to ‘OFF’ position after used to prevent accidental short circuit of the
clamps and to allow recharge from the wall adaptor.
10. Disconnect the Black negative (-) cable clamp first and place it to its storage position in
your SecureStart™.
11. ONLY after removing and storing the Black negative (-) cable clamp, disconnect the Red
positive (+) cable clamp last from the vehicle battery positive (+) terminal and place it to its
storage position in your SecureStart™.
12. It is mandatory to recharge your SecureStart™ immediately with wall adaptor for at least 4
hours.
Note: The SecureStart™ has successfully cranked on 12L diesel engine.
NOTE: Use SecureStart™ on gasoline-powered or diesel engines with a 12-volt or
24-volt cranking system. Read all instructions and safety warnings before use.

4
Warranty Terms and Conditions
Your SecureStart™ is covered by a conditional, limited warranty to the original purchaser.
Your SecureStart™ is warranted to be free from defects in material and workmanship for a
limited period (as stated on card) from the date of sale. If your jumpstart unit malfunctions
or fails within the warranty period because of a defect in material or workmanship, we will
repair or replace it, at our discretion, without charge. You must present a sales invoice or
receipt to prove the date of purchase. If the warranty seal sticker is damaged, the warranty
shall be voided.
Returned units determined to have been subjected to misuse shall not be covered under
warranty. This warranty does not cover defects or failures of your SecureStart™ due to any
cause other than defective manufacturer’s material or workmanship, including without
limitation any malfunctions or failures caused by repairs made by an unauthorized person,
mishandling, modifications, normal wear, unreasonable use or damage. IN NO EVENT
SHALL THE MANUFACTURER BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL
DAMAGES.
EXCEPT FOR THIS LIMITED WARRANTY, THE MANUFACTURER HAS NOT MADE, AND
SPECIFICALLY DISCLAIMS, ANY WARRANTY OR REPRESENTATION OF ANY KIND,
EXPRESS OR IMPLIED, DIRECT OR INDIRECT, OF PRODUCT FITNESS FOR A
PARTICULAR PURPOSE. THIS LIMITED, CONDITIONAL WARRANTY PROVIDES THE
EXCLUSIVE REMEDY FOR ANY CLAIM OR DAMAGE EXCEPT AS OTHERWISE
REQUIRED BY LAW.
5
IMPORTANT
Read All Instructions And Safety Warnings
Before Using SecureStart™
Warning / Safety Information
1. Read and follow all instructions in this manual before using the SecureStart™.
2. Follow all instructions published by the automobile and vehicle battery manufacturers,
especially the procedure of jump-starting of a vehicle.
3. KEEP OUT OF THE REACH OF CHILDREN.
4. NEVER ALLOW cable clamps (“+” & “-“) to TOUCH each other. Cable clamps are “live” at all
times, and will spark once they touch, SecureStart™ will generate heat too. Always ensure
clamps are stowed securely in clamp holders when not connected for jump-starting.
5. Check the vehicle cranking system voltage first (12V or 24V) before use. Turn the selector-
switch on the SecureStart™ to the correct vehicle cranking system voltage. Turn to the
wrong voltage will damage the vehicle electrical system.
6. ALWAYS VERIFY vehicle battery positive terminal (RED “+”) before connecting cable clamps
to battery. Be aware of connecting sequence.
7. Handle SecureStart™ and vehicle battery with care while jump-starting a vehicle. Vehicle
batteries generate hydrogen gas during normal battery operation, such gas may cause
explosion with a spark. Care should be taken to ensure sparks are not generated near the
vehicle battery. Sparks occur when connecting or disconnecting leads. Keep sparks and
flames away from batteries.
8. Keep hands and cables clear of fan blades, belts pulleys and other moving parts when
working near a running engine. Remove jewelry, watch and loose clothing when near the
engine compartment. Take extra care to protect eyes during jump-starting.
9. Do not charge the SecureStart™ in wet or moist locations through the DC charging jack.
Severe electrical shock may result.
10. Do not charge the SecureStart™ in an airtight container, provide adequate ventilation during
charging.
11. Do not attempt to disassemble the SecureStart™. Do not cut any cables or wires on this
product. The TMF®power pack contained within your unit is capable of generating very high
current. This current may cause severe burns or personal injury.
12. Use your SecureStart™ to jump-start vehicles that run with lead-acid battery only.
13. Never immerse SecureStart™ into water or seawater.
14. Keep SecureStart™ away from sunlight, hot and high humidity environment. Do not store
with metal parts such as tools and wires etc.
15. SecureStart™ contains non-spill-able sealed lead-acid batteries. Under normal and
appropriate use, the product is safe and there is no exposure to lead.
16. Return used SecureStart™ to sales outlet for recycling. // LEIM010001, 20090618//
Other SecureStart Remote Starter manuals
Popular Remote Starter manuals by other brands

Kings Adventure
Kings Adventure AKEP-LJS1000A_01 user manual

Voxx
Voxx PRO9056TWE Pursuit Series owner's manual

ProStart
ProStart ProStart CT-3360 user guide

Limitless Innovations
Limitless Innovations JumpSmart user manual

DieHard
DieHard 28.71686 Operator's manual

Motomaster
Motomaster 011-2062-4 product manual