INSTALLATION AND SET UP PROCEDURES.
The equipment (motor + controller) is ready for operation ; connect the line 115VAC supply source with the earth connection (the
section of additional line wires must be > 0,75mm²).
DO NOT USE THE DRIVE SYSTEM IN AN EXPLOSIVE ATMOSPHERE
DANGER : If changes on the calibrations are needed they must be done by qualified electrical maintenance personnel : THE
TRIMMERS MUST BE ADJUSTED WITH INSULATED SCREW DRIVES.
RXI CALIBRATION :- START THE MOTOR AND WAIT FEW MINUTES FOR THE THERMAL STABILIZATION
- MEASURE THE SPEED WITHOUT THE LOAD
- LOAD THE MOTOR AND CALIBRATE THE TRIMMER TILL THE SAME SPEED WILL BE OBTAINED
If changes on the internal wires connections or fuse exchange are needed TAKE-OFF THE MAIN SUPPLY BEFORE ANY
OPERATION.
AUTOMATIC RESTART OF THE CONTROLLER MAY OCCUR IF THE LINE POWER IS TEMPORARY LOST.
CONNECTION OF EXTERNAL DEVICES : PAY ATTENTION TO THE RIGHT CONNECTIONS OF THE INHIBIT AND 115VAC
SUPPLY
TROUBLESHOOTING.
MOTOR NOT RUN - CHECK THE MAIN POWER CONNECTION
- ENSURE THE MAIN SWITCH TO “ON”
- ENSURE INHIBIT OPEN
- CURRENT LIMIT (CHECK THE CAUSE OF MOTOR OVERLOAD)
BLOW FUSE
(GREEN LED OFF)
- DAMAGE WIRES
- WRONG LINE VOLTAGE
- MOTOR SHORT CIRCUIT
NO SPEED CONTROL - CHECK THE POTENTIOMETER WIRES
- CHECK THE CONNECTOR TO EXTERNAL SPEED
ALARM
(RED LED ON)
- CHECK THE LOAD TO ENSURE THE RATED POWER OPERATION OF THE
MOTOR AND IF THE ROTOR IS LOCKED