Semicool ERT-10-3-321C User manual

®
SEMICOOL
85-875 Bydgoszcz
tel./fax (+48) 052/346-40-12, 345-08-74, 345-08-75
ul. Chêciñska 11
Thermoregulator
Regulator parameters
ERT-10-3-321C ERT-10-2-221C ERT-10-2-222C
Installed regulator meets class II requirements for electric shock protection.
Regulator designed for 0I, I, and II class equipment.
Supply voltage - 230 V 50/60Hz
Ambient temperature - +5 C to +40 C
Humidity - 20% to 80 % RH
Degree of protection -regulator - IP20
Degree of protection -front panel - IP65 – for front panel assembly using gasket
compressor - 0,6 kW compressor - 1kW compressor - 1,5HP
defrosting heater - 0,6 kW AUX - 1kW AUX - 1 kW
AUX - 0,6 kW
Max. current running through terminals - 12 A
oo
Max. load:
1. COMP/UP
Cfn COMP
COMP
SET
2. DEF/DOWN
SET
3. SET SET
SET PRG
4. PRG/AUX
rl2 rL3
PRG Std
button – holding for more than 5 seconds activates one of preprogrammed compressor special modes
( parameter). Quick press returns to normal mode. button highlighting specifies compressor state: no
highlighting – compressor off; highlighting – compressor is on. Special mode is signaled by flashing button.
In change setting mode ( button highlighted) pressing the button increases the temperature. In parameter
modification mode pressing the button displays consecutive parameter symbol or increases the value. In input
service code mode pressing the button increases the code number.
button - holding for more than 5 seconds activates manual defrosting signaled by flashing. Automatic
defrosting is signaled by continuous highlighting. In change setting mode ( button highlighted) pressing the
button decreases the temperature. In parameter modification mode pressing the button displays preceding
parameter symbol or decreases the value In input service code mode pressing the button decreases the code
number.
button - holding for more than 1 second activates change setting mode signaled by highlighting
button. In parameter modification mode pressing the button switches between parameter symbol and its
value. In input service code mode pressing the button confirms the code. Holding and buttons for
more than 5 seconds activates all available parameters modification mode (preceded by inputting correct
service code)
button - holding for more than 5 seconds activates selected parameter modification mode (parameters not
requiring service code). In case of , = 2 parameter, quick button pressing switches on and off relay AUX (e.g.
lighting). In parameter modification mode holding the button for more than 1second saves modified
parameters and returns to normal mode. Holding the button while switching on till message displays,
returns to parameter default settings.
SEMICOOL
5
1
2
4
3
PRG
SET
AUX
DEF
COMP
1
ERT-10-3-321C ERT-10-2-221C ERT-10-2-222C

2356798 1
10A 16A
ERT-10-2-221C
ERT-10-2-222C
1,5 HP
Programming
key
230Vac
Thermostat
probe
Thermostat
probe
Defrost
probe
Defrost
probe
NL
ERT-10-2-221C
ERT-10-2-222C
Connections - output
5. LED display (3 - digit ) SdL- In standard mode it displays detector temperature determined by the parameter
(0 – thermostat probe, 1 – defrost probe). Displayed temperature range: between - 40 C and + 40 C.
Temperature below -10 C is displayed with resolution of 1 C, and temperature above -9.9 C with resolution of
0.1 C. In change settings mode (SET button highlighted) the set temperature is displayed. In programming mode –
parameter editing - parameter symbol or value is displayed. Alarm codes and service code being input are also
displayed (in service code input verification).
OO
OOO
O
ALARM ALARM
AUX AUX
According to the parameter ‘rL3’ According to the parameter ‘rL2’
10A
5A5A
Programming
key
23456798 1
230Vac NL
AUX AUX
ERT-10-3-321C
Dimensions and mounting
Mounting hole
71x29 mm
Regulator panel 77,2x36 mm
Housing dimensions behind mounting panel
with side catches and disassembled
cramps
Width - 83,5 mm
Height - 37 mm
Depth - 80 mm
2
Programming temperature setting
SET
UP DOWN
SET SET
SET
Manual defrosting
dEt DOWN/DEF
DOWN/DEF
Access to configuration parameters commonly available without a service code
PRG
Access to all configuration parameters
PRG SET
UP DOWN PRG
SET
Parameter modification
UP DOWN
SET
UP DOWN
SET
Saving new parameter values
PRG
To display or modify settings:
1) Press and hold for more than 1 second. The temperature setting is displayed and the button is highlighted.
2) Set the temperature using and .
3) Confirm by pressing again. Highlighting button is off. Current temperature is displayed.
If button is not pressed for 30 seconds, previous settings are restored.
It is possible to initiate defrosting manually. The necessary condition is that defrost probe temperature is below
( (final defrosting temperature) -1 ). To initiate defrosting process press and hold for more than 5
seconds. Manual process initiation is signaled by flashing button. When theprocess is initiated automatically
the button is highlighted continuously.
Press and hold for more than 5 seconds, the screen displays the code of the first commonly available parameter.
1) Press and hold and for more than 5 seconds, the screen displays “0”.
2) Press or to display “33” (password granting access to all configuration parameters). button
returns to normal running mode.
3) confirms the password. Confirming incorrect password displays “0”.
4) Correct password – code of the first modified parameter is displayed.
After displaying code of the first parameter:
1) Press or to display the number of a parameter to modify.
2) Press to display parameter value.
3) Press or to increase or decrease parameter value.
4) Press to initially save new parameter value and return to parameter code display.
5) To modify other parameters, repeat steps 1 to 4.
To save modified values, press and hold for more than 1 second and the programming procedure is
terminated.
OC

Compressor standstill time –thermostat probe malfunction
Compressor running time - thermostat probe malfunction
Nr Code U.M. Type
Default
Min Max
Parameter
Probe calibration (regulator detector)
Stability/measurement delay (delay between displays
0 – at 0.25s intervals,1-1s,2-2s)
Select probe displayed
0 – thermostat probe
1 – defrost probe
Histeresis
Min. setting value
Max. setting value
Min. compressor standstill time(0–nolimit )
Max. compressor running time (121 – no limit)
1
2
3
4
5
6
7
8
9
10
11
12
Compressor turn off temperature in the 3rd – special mode (Cfn = 3)
Probe parameters
Control parameters
Compressor parameters
OFs
Stb
SdL
HYS
SLo
SHI
oFC
onC
oFE
onE
CFn
CSt
OC
OC
OC
OC
OC
min
min
min
min
1
22020
2
12110
2 +1 -35 SHI
2
22
60 2 121
10 2 120
15 2 120
020
2
2
2
2
2 0 -35 +25
103
+10 SLo +25
001
0-55
Special running modes – “COMP” (to enter special mode, press and hold COMP for
more than 5 seconds; to leave special mode, quickly press COMP)
0 - no “COMP’’ button control
1 - always off - signaled by short flashes of COMP button
2 - always on - signaled by long flashes of COMP button
3 - always on with temperature limit – Cst parameter
Compressor is turned off when it reaches the temperature specified by Cst
parameter, and turned on when temperature rises to Cst + AHS
Modes 2 and 3 – active limits: min. compressor standstill time and
max. compressor running time.
Unit special running modes
COMP
CFn COMP
CFn COMP
Special functions
PRG
Std
DOWN
Alarms
Std
EE
E0
E1
HI
L0
To enter special mode, press and hold for more than 5 seconds.
“Compressor - always off” mode ( =1) is signaled by short flashes of button.
“Compressor - always on” modes ( =2 or 3) signaled by longer flashes of button.
1) Holding while initiating the regulator (during dot flashing) restores default settings; signaled by
displaying for 2.5 seconds.
2) Holding while initiating the regulator (during dot flashing) enters service mode. In service mode
compressor control time limits are eliminated; useful when testing and initiating cooling unit.
- displayed during initialization of regulator with default settings
- signals read/write EEPROM data error
- thermostat probe malfunction
- defrost probe malfunction
- high temperature alert (displayed In rotation with detector temperature specified by SdL parametr)
- low temperature alert (displayed In rotation with detector temperature specified by SdL parametr)
3
13 dtY 2004
Defrosting mode
0 - defrosting heater – termination based on the temperature or when time limit
is exceeded
1 - "hot gas" (compressor is on) -termination based on the temperature or
when time limit is exceeded
2 - defrosting heater - termination after time limit is exceeded
3 - hot gas - termination after time limit is exceeded
4 - defrosting off
Detector not required in modes 2, 3 and4-no“nodetector” alarms.
Defrosting parameters

Fan controls
0 – fan is on, no defrosting
1 – fan is on depending on the evaporator detector temperature
Setting – fan switching on
fan on if: evaporator temp.< fan setting – alarm hist. (FSt - AHS)
fan off: evaporator temp. > fan setting (FSt)
Fan switching off if compressor is on.
0 – no switching off
1 – switching off
Low temp. alarm – deviation from setting
ALo=0-alarm off
High temp. alarm – deviation from setting
AHI=0-alarm off
2
1
2
2
2
1
1
1
2
2
1
+15
0
1
2
5
5
60
6
1
2
-30
01
0
1
0
0
0
0
0
6
5
0
1
5
20
20
120
20
+20
001
O
C
O
C
O
C
O
C
min
min
Fan during defrosting and dripping
0 – switching on
1 – switching off
Temp. alarm delay
Fan standstill time after dripping phase
19
20
21
22
23
24
25
26
27
28
28
FFn
FSt
Fco
FdF
FSd
AHS
ALo
AHI
AdL
rL2
rL3
Temperature and fan alarm histeresis
High temp. alarm on = setting + AHI
High temp. alarm off = setting + AHI - AHS
Low temp. alarm on = setting - ALo
Low temp. alarm off = setting - ALo + AHS
Relay (output) 2 - function
0 - inactive (off)
1 - fan
2 - lighting -'PRG' button
3 - alarm HI – transmitter on during 'HI' message
4 - alarm LO – transmitter on during 'LO' message
5 - LO and HI alarms - transmitter on during 'LO' and 'HI' messages
6 - defrosting
only ERT-10-2-221C and ERT-10-2-222C
Relay (output) 3 - function
0 - inactive (off)
1 - fan
2 - lighting -'PRG' button
3 - alarm HI – transmitter on during 'HI' message
4 - alarm LO – transmitter on during 'LO' message
5 - LO and HI alarms - transmitter on during 'LO' and 'HI' messages
only ERT-10-3-321C
U.M. Type
Default.
Min Max
Nr
Code
Parameter
14
15
16
17
18
Defrosting parameters
Time between defrosting
End of defrosting temperature
Drip time – compressor and fan switching on delay
Value displayed on the screen during defrosting
0 – actual temperature
1 – commencement of defrosting temperature – return to normal indications
after reaching the temperature before defrosting or reaching the set temperature
Max. defrosting time
For modes 2 and3–itisdefrosting time.
121 – unlimited defrosting time
dCL
dEt
dLt
dAd
ddL
O
C
min
min
1
1
1
1
2001
3020
8
60
+7
2
0
2
40
+35
121
hours.
Evaporator fan parameters
Alarm parameters
Other settings
4
Parameter types:
1 - Parameters available without service password.
2 - Parameters requiring service password (all parameters)
This manual suits for next models
2
Table of contents
Popular Controllers manuals by other brands

CRE Technology
CRE Technology Gensys Compact Prime Technical documentation

Balboa Instruments
Balboa Instruments GL8000 Mach 3 Tech sheet

Tekmar
Tekmar Mixing Control 356 manual

FRANCE ETUVES
FRANCE ETUVES C3030 Original instructions

Medialink
Medialink MLC 62 IR D user guide

Controlli
Controlli NR9003 Mounting instructions

Inverter
Inverter MPPT Series user manual

Eaton
Eaton HFX Series Installation and operation manual

IP Power
IP Power 9258 Quick start user manual

Roger Technology
Roger Technology CTRL Instruction and warnings for the installer

JUMO
JUMO IMAGO 500 Interface description

Aerotech
Aerotech Ensemble HLe Hardware manual