HOLOVISION Viking E-10 User manual

Manual Type 1.1.0.3-RF
Viking E-10, C-2000B
with Essex 265 Controller
For Models
Specifications
Communication
Viking E-10 Doorbox uses “half-duplex”
communication, allowing for high speaker and
microphone volume, witout the possibility of
feedback.
Viking C-2000A allows up to 4 doorphones to
share a CO line.
Access Control
Essex 5 button keypad
2 relays
5-6 users
16.5 VAC power supply included
nternal rectifier gives optional ‘’dc out’’ for strikes
INSTALLATI N
INSTRUCTI NS
501 E. Goetz Ave.
Santa Ana, Ca 92707
www.eholovision.com
Ph. 714-434-6904
Fax 800-362-0002
H L VISI N
101-V K
107-V K
201-V K
203-V K
301-V K
302-V K
Holovision Face Plate
shown with E-10
installed
VIKINGcModel C-2000B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
EARTH GND
PHONE L NE NPUT
L NE OUT TO PHONES
ENTRY PHONE 1
DOOR STR KE 1
ENTRY PHONE 2
DOOR STR KE 2
ENTRY PHONE 3
DOOR STR KE 3
ENTRY PHONE 4
DOOR STR KE 4
DOORBELL SW TCH/AUX NPUT
AUX CONTACT OUTPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
ON
1 2 3 4 5
ANALOG STAT ON NPUT
CNNECTC LINE IN
13.8
VAC
1.25A

Viking C-2000B and Essex CM265 Wiring
AC Out for Strike
To Door Phone 2
To Door Phone 3
To Door Phone 4
Holovision Faceplate
with Keypad
NOTE 1: Remove the jumper wire & MOVs from left side terminal strip. Wire right side terminal strip “color for color”.
NOTE 2: MOV (metal oxide varistor) is the small red component which is included. ts purpose is to absorb “inductive
kick back” which can be created when power is removed from the strike.
Page 2 TYPE 1.1.0.3-RF
VIKINGcModel C-2000B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
EARTH GND
PHONE L NE NPUT
L NE OUT TO PHONES
ENTRY PHONE 1
DOOR STR KE 1
ENTRY PHONE 2
DOOR STR KE 2
ENTRY PHONE 3
DOOR STR KE 3
ENTRY PHONE 4
DOOR STR KE 4
DOORBELL SW TCH/AUX NPUT
AUX CONTACT OUTPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
ON
1 2 3 4 5
ANALOG STAT ON NPUT
13.8
VAC
1.25A
House
Telephones
Essex Model 265
NC 2
NO 2
COM 2
NC 1
NO 1
COM 1
DC
OUT
AC
N
Remote
Monitor
Earth
16.5
VAC
Gate Strike
Remote
Bypass
Button
22/12 Essex Keypad Cable

Viking C-2000B and Essex CM265 Wiring
Contact Closure for Gate Operation
NOTE 1: Remove the jumper wire & MOVs from left side terminal strip. Wire right side terminal strip “color for color”.
TYPE 1.1.0.3-RF Page 3
To Door Phone 2
To Door Phone 3
To Door Phone 4
Holovision Faceplate
with Keypad
VIKINGcModel C-2000B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
EARTH GND
PHONE L NE NPUT
L NE OUT TO PHONES
ENTRY PHONE 1
DOOR STR KE 1
ENTRY PHONE 2
DOOR STR KE 2
ENTRY PHONE 3
DOOR STR KE 3
ENTRY PHONE 4
DOOR STR KE 4
DOORBELL SW TCH/AUX NPUT
AUX CONTACT OUTPUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
ON
1 2 3 4 5
ANALOG STAT ON NPUT
13.8
VAC
1.25A
House
Telephones
Essex Model 265
NC 2
NO 2
COM 2
NC 1
NO 1
COM 1
DC
OUT
AC
N
Remote
Monitor
Earth
16.5
VAC
22/12 Essex Keypad Cable
“OPEN”
Terminals
on Gate
Motor

Instructions for E-10 Doorphones
n certain noisy locations (traffic or wind), the microphone volume may need to be decreased. A symptom of this is one-way talk path, in which the distant party
cannot be heard over the speaker. A “MIC V L” adjustment is provided on the doorphone for increasing or decreasing the microphone volume.
Microphone Volume
D P Position Description
Switch
1 ON Auto Answer - Doorphone answers when incoming call is detected.
2 ON Call Timer - See E-10 manual for a description of this feature. Recommended setting is “ON”. This is the factory default.
3 OFF Programming Mode - E-10 is factory pre-set, and normally does not need re-programming. Refer to E-10 manual
(Viking document which is included) for details
ON ON ON
1 2 3
ON ON ON
1 2 3
+
+
Spkr Vol
Mic Vol
Holovision recommends the default settings on the dip switches. See the E-10 manual for more information.
(E-10)
The “SPKR V L” pot can be adjusted to increase or decrease the speaker volume to the desired level.
Speaker Volume
Dip Switch Settings
Doorphone Programming
Page 4 TYPE 1.1.0.3-RF
Instructions for C-2000B Controller
D P Position Description
Switch
1 OFF Auxiliary Contact Mode
1 ON Doorbell Mode- Factory Default
2 OFF Normal Operation Mode- Factory Default
2 ON Security Code Bypass Mode
3 OFF Entry Phone automatic disconnect (CPC) disabled
3 ON Entry Phone automatic disconnect (CPC) enabled- Factory Default
4 OFF Entry Phone busy signal disabled
4 ON Entry Phone busy signal enabled- Factory Default
5 OFF Single Line Ring Through Mode- Factory Default
5 ON Analog Station Dial Through Mode
Dip Switch Settings C-2000B
ON
1 2 3 4 5

Viking Operation
peration Instructions for C-2000B Controller
ANSWER A CALL FR M D RB X
When the phones ring, pick up a phone to be connected to the visitor.
PLACING C LINE CALLS N H LD (CALL WAITING)
f a phone call is in progress, and a doorbox is activated, one to four beeps will be heard (indicating which doorphone is calling). To place the call in progress on
hold and speak to the visitor, push #. When you want to return to the original phone call, push #.
ACTIVATING A D RSTRIKE R PENING A GATE
When a call is in progress, press to open the gate and return to the original call. f you do not want to open the gate, press # to return to the original call.
**
1 Move D P switch 2 from OFF to ON position.
2 Come off-hook with any house phone connected to terminals 4 & 5 LINE UT T PH NES.
3Double beep indicates accessing the programming mode.
4 You can now program the C-2000A. The features covered in this manual are Maximum Doorphone Ring Count
and Door Strike Activation Time. For information on programming other features see the Viking C-2000 manual.
5 Move D P switch 2 back to the FF position.
STEP ACTION
Access Programming Mode (Local Access)
1 Follow steps 1-3 from “Access Programming Mode” (above).
2 At “double beep” enter desired number of rings, followed by #61. Example: For 7 rings, enter “07#61”.
3Hang up the phone.
STEP ACTION
Maximum Doorphone Ring Count - Factory Default is 5 Rings
1 Follow steps 1-3 from “Access Programming Mode” (above).
2 At “double beep” enter desired number of rings, followed by:
#19 for Gate 1, #29 for Gate 2, #39 for Gate 3, #49 for Gate 4
Examples:
Set Gate 1 for 8 seconds (08#19); Set Gate 3 for 15 seconds (15#39)
3 Hang up the phone.
STEP ACTION
Program Gate Strike Relays - Factory Default is 0.5 Seconds
Doorphone Programming
TYPE 1.1.0.3-RF Page 5

Set Essex Relay ptions
Step Action
Procedure
G AL: To use jumper pins on circuit board to configure standard
relay options. n this configuration, Codes 1 and 2
operate Relay 1. Codes 3, 4, 5 operate Relay 2.
1 Relay 1 and 2 activate. Only Relay 1 latch*
Code Relay 1 Relay 2
Open Latch Open Latch
Master Code No No No No
Code 1,2 Yes Yes No No
Code 3, 4, 5 No No Yes No
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
Master Unlock
1, 2 Unlock
3,4,5 Unlock
1,2 Latch
3, 4,5 Latch
CCTV
Doorbell
Relay 1
Relay 2
Step Action
2 Relay 1 and 2 activate and latch*
Code Relay 1 Relay 2
Open Latch Open Latch
Master Code No No No No
Code 1,2 Yes Yes No No
Code 3, 4, 5 No No Yes Yes
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
Master Unlock
1, 2 Unlock
3,4,5 Unlock
1,2 Latch
3, 4,5 Latch
CCTV
Doorbell
Relay 1
Relay 2
*LATCH NG RELAY: n order to latch either relay, simply enter the code, followed by “7”.
Repeat (code, 7) in order to unlatch the relay.
The top example would be used where the driveway gate was connected to Relay 1 (and could be locked open),
and the pedestrian gate was connected to Relay 2. (No latching possible).
Page 6 TYPE 1.1.0.3-RF

Programming the Essex Keypad
1 Enter “Master Code”
2 Enter 113 (3 beeps).
3 Enter User Code 2.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 2
Step Action
1 Press “Program” switch once. (keypad will beep 4 times)
2 Once “Program” switch is pressed, you have 2 minutes to complete Step 5.
3 Press “1119”. (you will hear 3 beeps)
4 Step 5 must be completed within 5 seconds of Step 3.
5 Enter “Master Code” *
6 Wait 5 seconds for 3 beeps to confirm new “Master Code”.
Set Master Code
Step Action
1 Enter “Master Code”
2 Enter 111 (3 beeps).
3 Enter User Code 1.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 1
Step Action
* MASTER CODE: The default Master Code is 13579. This should be replaced by a unique code
to be used only by your company. The Master Code can be 3 to 8 digits long.
1 Enter “Master Code”.
2 Enter 115 (3 beeps).
3 Enter User Code 3.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 3
Step Action
TYPE 1.1.0.3-RF Page 7

Programming the Essex Keypad
1 Enter “Master Code”.
2 Enter 119 (3 beeps).
3 Enter User Code 5.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 5
Step Action
1 Enter Master Code .
2 Enter address of code to be deleted (111, 113, etc.).
3 Do not enter any code until you hear 3 reset beeps.
4 Wait 5 seconds for 3 reset beeps.
Delete Any Code
Step Action
Note: User codes can be 3 to 8 digits
1 Enter any User Code (1 -5).
2 Enter “7”. This will cause the relay to latch (subject to the jumper pin settings - see Page 5).
3 To unlatch the relay, re-enter the user Code, followed by “7”.
Step Action
Latch a Relay
1 Enter “Master Code”.
2 Enter 117 (3 beeps).
3 Enter User Code 4.
4 Wait 5 seconds for 3 reset beeps.
Set User Code 4
Step Action
Page 8 TYPE 1.1.0.3-RF

Programming the Essex Keypad
1 Press “Program” switch (keypad will beep 4 times).
2 Enter 1117 (3 beeps).
3 Enter 1 for every 1 second latch time, and 5 for every 5 seconds.
Examples:
6 seconds = 5, 1
8 seconds = 5, 1, 1, 1
12 seconds = 5, 5, 1, 1
4 Wait 5 seconds for 4 reset beeps.
Set Activation Time Of Relay 1 (User codes 1 & 2 - see note below)
Step Action
1 Press “Program” switch (keypad will beep 4 times).
2 Enter 1115 (3 beeps).
3 Enter 1 for every 1 second latch time, and 5 for every 5 seconds.
Examples:
6 seconds = 5, 1
8 seconds = 5, 1, 1, 1
12 seconds = 5, 5, 1, 1
4 Wait 5 seconds for 4 reset beeps.
Set Activation Time Of Relay 2 (User codes 3, 4& 5 - see note below)
Step Action
Note: The above 2 steps are actually setting the activation times for user code 1, 2 and user code 3, 4, 5. Using the
jumper pin setting as shown in “Set Essex Relay Options”, this will set activation time of Relays 1 & 2.
TYPE 1.1.0.3-RF Page 9

www.eholovision.com
501 E. Goetz Ave.
Santa Ana, Ca 92707
Ph. 714-434-6904
Fax 800-362-0002
Other manuals for Viking E-10
1
This manual suits for next models
1
Table of contents
Popular Controllers manuals by other brands

Phocos
Phocos CIS-MPPT 50/10 user manual

Siemens
Siemens SINAMICS S120 Equipment manual

Honeywell
Honeywell UDC1200 MICRO-PRO product manual

Danfoss
Danfoss ECL Comfort 310 installation guide

Doug Fleenor Design
Doug Fleenor Design Preset 10 Architectural Two owner's manual

Omron
Omron R88D-1SN10F-ECT user manual

Texas Instruments
Texas Instruments TPS92512EVM-001 user guide

Flycolor
Flycolor X-Tower F4 FC user manual

Ocean Optics
Ocean Optics TR-2 quick start guide

Linear
Linear ANALOG DEVICES DC2448A-D Demo Manual

Clearwater Enviro Technologies
Clearwater Enviro Technologies AG-150 Installation & operation manual

SKYDANCE
SKYDANCE V4-U manual