Sencore OmniHub CMP203 User manual

January 2020
www.sencore.com | 1.605.978.4600 Revision 1.3
OmniHub MP203
Media Platform
User Manual

OmniHub MP203– User Manual
Page 2 of 109
Copyright
© 2019 Sencore, Inc. All rights reserved.
3200 Sencore Drive, Sioux Falls, SD USA
www.sencore.com
This publication contains confidential, proprietary, and trade secret information. No part of this document
may be copied, photocopied, reproduced, translated, or reduced to any machine-readable or electronic
format without prior written permission from Sencore. Information in this document is subject to change
without notice and Sencore Inc. assumes no responsibility or liability for any errors or inaccuracies. Sencore,
Sencore Inc, and the Sencore logo are trademarks or registered trademarks in the United States and other
countries. All other products or services mentioned in this document are identified by the trademarks, service
marks, or product names as designated by the companies who market those products. Inquiries should be
made directly to those companies. This document may also have links to third-party web pages that are
beyond the control of Sencore. The presence of such links does not imply that Sencore endorses or
recommends the content on those pages. Sencore acknowledges the use of third-party open source
software and licenses in some Sencore products. This freely available source code can be obtained by
contacting Sencore Inc.
About Sencore
Sencore is an engineering leader in the development of high-quality signal transmission solutions for the
broadcast, cable, satellite, IPTV, telecommunications, and professional audio/video markets. The company’s
world-class portfolio includes video delivery products, system monitoring and analysis solutions, and test and
measurement equipment, all designed to support system interoperability and backed by bestin-class
customer support. Sencore meets the rapidly changing needs of modern media by ensuring the efficient
delivery of high-quality video from the source to the home. For more information, visit www.sencore.com.

OmniHub MP203– User Manual
Page 3 of 109
Revision History
Date Version Description Author
12/27/18 1.0 First Draft SW
04/02/19 1.1 Add new modules and new features DA
05/23/19 1.2 Add new modules RS
12/06/19 1.3 Add new Modules and new features EH
This guide contains some symbols to call your attention.
DANGER
The DANGER symbol calls your attention to a situation
that, if ignored, may cause physical harm to the user.
AUTION
The AUTION symbol calls your attention to a situation
that, if ignored, may cause damage to Our product.
NOTE
The NOTE symbol calls your attention to important
information.
TIP
The TIP symbol calls your attention to additional
information that, if followed, can make procedures more
efficient.
Red Arrow
The Red Arrow symbols point to import details mention the
context above or below an image.
Blue Arrow
The Blue Arrow symbol indicates the motion path of an
item in an operation step.
Thick Arrow
The thick Arrow symbol calls your attention to a serial of
operation csteps mentioned in the context.
This guide also contains the following text conventions.

OmniHub MP203– User Manual
Page 4 of 109
Safety nstructions
• Read these instructions
• Keep these instructions
• Heed all warnings
• Follow all instructions
• Do not use this apparatus near water
• lean only with dry cloth
• Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions
• Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat
• Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong is provided for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.
• Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
• Only use attachments/accessories specified by the manufacturer.
• Unplug this apparatus during lightning storms or when unused for long periods of
time.
• Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
• Do not expose this apparatus to dripping or splashing and ensure that no objects
filled with liquids, such as vases, are placed on the apparatus.
• To completely disconnect this apparatus from the A Mains, disconnect the
power supply cord plug from the A receptacle.
• The mains plug of the power supply cord shall remain readily operable.
• Damage Requiring Service: Unplug this product from the wall outlet and refer
servicing to qualified service personnel under the following conditions:
o When the power-supply cord or plug is damaged.
o If liquid has been spilled, or objects have fallen into the product.
o If the product has been exposed to rain or water.
o If the product does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the
operating instructions as an improper adjustment of the controls may
result in damage and will often require extensive work by a qualified
technician to restore the product to its normal operation.
o If the product has been dropped or damaged in any way.
o The product exhibits a distinct change in performance.
• Replacement Parts: When replacement parts are required, be sure the service
technician uses replacement parts specified by Sencore, or parts having the
same operating characteristics as the original parts. Unauthorized part
substitutions made may result in fire, electric shock or other hazards.

OmniHub MP203– User Manual
Page 5 of 109
SAFETY PRECAUT ONS
There is always a danger present when using electronic equipment.
Unexpected high voltages can be present at unusual locations in defective
equipment and signal distribution systems. Become familiar with the equipment
that you are working with and observe the following safety precautions.
• Every precaution has been taken in the design of your product to ensure that it is
as safe as possible. However, safe operation depends on you the operator.
• Always be sure your equipment is in good working order. Ensure that all points
of connection are secure to the chassis and that protective covers are in place
and secured with fasteners.
• Never work alone when working in hazardous conditions. Always have another
person close by in case of an accident.
• Always refer to the manual for safe operation. If you have a question about the
application or operation email Pro are@Sencore.com
• WARNING – To reduce the risk of fire or electrical shock never allow your
equipment to be exposed to water, rain or high moisture environments. If exposed
to a liquid, remove power safely (at the breaker) and send your equipment to be
serviced by a qualified technician.
• To reduce the risk of shock the power supply must be connected to a mains socket
outlet with a protective earthing connection.
• For the mains plug the main disconnect and should always remain readily
accessible and operable .
• When utilizing D power supply, the power supply MUST be used in conjunction
with an over-current protective device rated at 50 V, 5 A, type: Slow-blo, as part
of battery-supply circuit.
• To reduce the risk of shock and damage to equipment, it is recommended to
ground the unit to the installation’s rack, the vehicle’s chassis, the battery’s
negative terminal, and/or earth ground.
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment.

OmniHub MP203– User Manual
Page 6 of 109
Package Contents
The following is a list of the items that are included:
1. OmniHub MP203 chassis
2. OmniHub MP203 Quick Start Guide
3. A power cables
4. Breakout or adapter cables depending on option modules
If any of these items were omitted from the packaging please email

OmniHub MP203– User Manual
Page 7 of 109
Table of Contents
COPYRIGHT ............................................................................................................................................. 2
ABOUT SENCORE ..................................................................................................................................... 2
REVISION HISTORY .................................................................................................................................. 3
TABLE OF CONTENTS ............................................................................................................................... 7
SECTION 1 OVERVIEW ............................................................................................................................. 9
1.1 PRODUCT OVERVIEW ........................................................................................................................10
1.2 FRONT PANEL OVERVIEW ..................................................................................................................10
1.3 REAR PANEL OVERVIEW ....................................................................................................................10
1.4 OPTION MODULE OVERVIEW .............................................................................................................11
SECTION 2 INSTALLATION ..................................................................................................................... 15
2.1 RACK INSTALLATION..........................................................................................................................16
2.2 AC POWER CONNECTION ..................................................................................................................16
SECTION 3 WEB INTERFACE OPERATION ............................................................................................... 18
3.1 OMNIHUB CMP203 WEB INTERFACE OVERVIEW ..................................................................................19
3.1.1 Connecting to the Management Port .....................................................................................19
3.1.2 LOGGING INTO THE CMP203 WEB INTERFACE ......................................................................................19
3.2 STATUS OVERVIEW ...........................................................................................................................19
3.2.1 STATUS ..........................................................................................................................................20
3.2.2 SYSTEM SETTING ..............................................................................................................................21
3.2.3 IP INPUT ........................................................................................................................................23
3.2.4 IP OUTPUT .....................................................................................................................................2
3.3 MODULE CONFIGURATION .................................................................................................................31
RECEIVER MODULES ......................................................................................................................................31
3.3.1 CR2-DVBC-00...........................................................................................................................31
3.3.2 CR2-DVBC-01...........................................................................................................................36
3.3.3 CR2-DVBS2CI-00 ......................................................................................................................37
3.3.4 CR2-DVBS2 TA-00/00A ...........................................................................................................38
3.3.5 CR2-8VSB-00 ...........................................................................................................................38
3.3.5.1 Module Status ....................................................................................................................39
3.3.5.2 Module Settings ..................................................................................................................39
3.3.6 CR2-DVBT2CI-00 ......................................................................................................................43
ENCODER MODULES ......................................................................................................................................45
3.3.7 CE2-HDMI-00/R01 ...................................................................................................................45
3.3.8 CE2-HDMI-02 ..........................................................................................................................53
3.3.9 CE2-HDMI-02C ........................................................................................................................57
3.3.10 CE2-HDMI-05/05A ..............................................................................................................61
3.3.11 CE2-SDI-00 ..........................................................................................................................65
3.3.12 CE2-CVBS-00/R01/R01A .....................................................................................................68
MODULATION MODULES ................................................................................................................................ 2
3.3.13 CM2-QAMA-00/R00 ...........................................................................................................72
3.3.14 CM2-QAMA-R01/R01A .......................................................................................................76
3.3.15 CM2-QAMB-00/R00 ............................................................................................................77
3.3.16 CM2-QAMB-R01/R01A .......................................................................................................78
3.3.17 CM2-8VSB-R01/R01A .........................................................................................................78
3.3.18 CM2-O DM-R01/R01A .......................................................................................................79

OmniHub MP203– User Manual
Page 8 of 109
3.3.19 CM2-ISDBT-R01/R01A ........................................................................................................80
FUNCTION MODULES .....................................................................................................................................82
3.3.20 CP2-EAS-00 .........................................................................................................................82
3.3.21 CP2-CAM-00 .......................................................................................................................86
SECTION 4 APPENDICES ......................................................................................................................... 88
APPENDIX A - ACRONYMS AND GLOSSARY .......................................................................................................89
APPENDIX B - A MONROE ONENETSE CONFIGURATION AND TESTING .................................................................90
APPENDIX C - SPECIFICATION ........................................................................................................................94
APPENDIX D - WARRANTY ......................................................................................................................... 109
APPENDIX E - SUPPORT AND CONTACT INFORMATION .................................................................................... 109
1 Returning for Service or Calibration ......................................................................................... 109
2 RMA Number ............................................................................................................................ 109
3 Shipping the Product ................................................................................................................ 109

OmniHub MP203– User Manual
Page 9 of 109
Section 1 Overview
SECTION 1 OVERVIEW ............................................................................................................................. 9
1.1 PRODUCT OVERVIEW ........................................................................................................................10
1.2 FRONT PANEL OVERVIEW ..................................................................................................................10
1.3 REAR PANEL OVERVIEW ....................................................................................................................10
1.4 OPTION MODULE OVERVIEW .............................................................................................................11

OmniHub MP203– User Manual
Page 10 of 109
1.1 Product Overview
OmniHub MP203 is a new generation of ompact Media Platform in Modular design
which focuses on cost-effective commercial TV market and traditional DTV market. This
is a 1RU chassis with single power supply unit and six hot modules at the back and one
modulator output in front of the unit. Thanks to the benefit of high-density, strong-
performance and large-flexibility, OmniHub MP203 product can meet all the major
video delivery requirements or signal receiving, descrambling, encoding, multiplexing,
modulation and IP processing depending on variety of model.
With powerful embedded Gigabit switch, optional commercial/broadcast encoder and
multi-mode receiver and modulator modules, it can be configured flexibly to meet any
video delivery requirements .Due to its compact design and powerful function, it can be
widely used at hotel, hospital, community, club, campus and DTV headend room where
massive programs are required to be processed in a cost-effective way. MP203 also
provides a straight-forward web interface accessible via all major browsers and
complete control of the unit. Every MP203 ships with the software suite pre-loaded on
appropriate hardware. The physical connectors available on the back of the chassis will
be depending on the optional input/output configuration.
1.2 Front Panel Overview
1. Modulation Status and Modulation Power Indicators, Modulation Output Tuner
(Only be embedded in Encoder Modulator, Receiver Modulator)
2. ooling Air Intake
3. Reset button and Power LED indicator
4. Status LED indicator
5. 2 RJ45 Management ports
6. 2 RJ45 Data ports
1.3 Rear Panel Overview
The OmniHub MP203 have exhaust fans at the top of the unit. Please mind not to
obstruct the air intake at the front and air exhaust at the top.

OmniHub MP203– User Manual
Page 11 of 109
1. Slot 1 for Option Module
2. Slot 2 for Option Module
3. Slot 3 for Option Module
4. Slot 4 for Option Module
5. Slot 5 for Option Module
6. Slot 6 for Option Module
7. hassis ground
8. Power Supply
9. On/Off switch
1.4 Option Module Overview
This describe the MP203 platform and all available modules that can expand the
functionality of the MP203 platform.
CMP
20
3
chassis
Description
Baseboard MP203-SEN 1RU chassis, Single PSU, 4xGbE ports, 14
LEDs and six hot swappable slots with 1
Modulator output in front panel
Receiver Modules
Description
R2-DVB -00 4 channel DVB- Annex A/ /DTMB
receiving module, 1 RF input connector with
4 tuners and 2 I slots
R2-DVB -01 4 channel DVB- Annex B/ISDBT receiving
module, 1 RF input connected with 4 tuners
and 2 I slots
R2-DVBS2 I-00 4 channel DVB-S2 receiving module, 2 input
connectors each with 2 transponders
receiving, with 2 I slots and independent
power supplies for each LNB.
R2-DVBS2FTA-00 4 channel DVB-S2 receiving module, 4 input
connectors. Independent power supplies for
LNB 1 and 3 only.
R2-DVBS2FTA-00A 8 channel DVB-S2 receiving module,
another interface card added on R2-
DVBS2FTA-00, each module occupies 2
slots.

OmniHub MP203– User Manual
Page 12 of 109
R2-8VSB-00 4 channel 8VSB receiving module, 4 input
connectors with 4 tuners.
R2-DVBT2 I-00 4 channel DVB-T/T2 receiving module, 1
input connected with 4 tuners and 2 I slots.
* R2-DVB -00, R2-DVB -01, R2-DVBT2 I-00, R2-DVBS2 I-00 are Different Hardware
but share the same Software.
* R2-DVBS2FTA-00, R2-DVBS2FTA-00A are Different Hardware but share the same
Software.
Encoder Modules
Description
E2-HDMI-00 4 channel HDMI encoding module, supports
H.264 HD/SD, MPEG-2 SD, MPEG1L2, A 3
and AA audio.
E2-HDMI-R01 4 channel HDMI encoding module, supports
H.264 HD/SD, MPEG-2 SD, MPEG1L2, A 3
and AA audio. Support OSD subtitle, logo
picture and QR code overlay
E2-HDMI-02 2 channel HDMI encoding module, supports
H.264 HD/SD, MPEG-2 SD, MPEG1L2, A 3
and AA audio, and supports input.
E2-HDMI-02 2 channel HDMI encoding module, supports
H.264 HD/SD, MPEG-2 SD, MPEG1L2, A 3
and AA audio. Module also supports
and analog audio input.
E2-HDMI-05 4 channel HDMI encoding module, supports
H.264/H.265 HD/SD, MPEG-2 SD,
MPEG1L2, A 3 and AA audio, and support
OSD subtitle, logo picture and QR code
overlay.
E2-HDMI-05 8 channel HDMI encoding module, supports
H.264/H.265 HD/SD, MPEG-2 SD,
MPEG1L2,A 3 and AA audio, and support
OSD subtitle, logo picture and QR code
overlay, each module occupies 2 slots,
E2- VBS-00 6 channel VBS encoding module, supports
H.264/MPEG-2 SD, MPEG1L2.
E2- VBS-R01 8 channel VBS encoding module, supports
H.264, MPEG1L2.
E2- VBS-R01A 16 channel VBS encoding module,
supports H.264, MPEG1L2, the modules
occupy 2 slots.

OmniHub MP203– User Manual
Page 13 of 109
E2-SDI-00 2 channel SDI encoder bitrate supports
H.264/MPEG-2 HD/SD, MPEG1L2, AA
and A 3 audio, and supports and
analog audio input.
Modulator Module
Description
M2-QAMA-R00 16 channel QAM modulator module, Annex
A/ , non-adjacent output, and 1 RF female
port for output
M2-QAMB-R00 16 channel QAM modulator module, Annex
B, non-adjacent output, and 1 RF female
port for output
M2-QAMA-R01 4 channel QAM modulator module, Annex
A/ , adjacent output, and 1 RF female port
for output
M2-QAMA-R01A 8 channel QAM modulation module, Annex
A/ , adjacent output, and 1 RF female port
for output
M2-QAMB-R01 4 channel QAM modulation module, Annex
B, adjacent output, and 1 RF female port for
output
M2-QAMB-R01A 8 channel QAM modulation module, Annex
B, adjacent output, and 1 RF female port for
output
M2-OFDM-R01 4 channel OFDM modulation module,
adjacent output, and 1 RF female port for
output
M2-OFDM-R01A 8 channel OFDM modulation module,
adjacent output, and 1 RF female port for
output.
M2-ISDBT-R01 4 channel ISDBT modulation module,
adjacent output, and 1 RF female port for
output.
M2-ISDBT-R01A 8 channel ISDBT modulation module,
adjacent output, and 1 RF female port for
output
M2-8VSB-R01 4 channel 8VSB (ATS ) modulation module,
adjacent output, and 1 RF female port for
output

OmniHub MP203– User Manual
Page 14 of 109
M2-8VSB-R01A 8 channel 8VSB 9ATS ) modulation
module, adjacent output, and 1 RF female
port for output.
*All -R01 model same the same hardware, and all -R01A models share the same model
except for the OFDM Module.
Function Modules
Description
P2-EAS-00 EAS processing module, supports EAS
triggering by analogue EAS input and Digital
EAS input.
P2- AM-00 AM processing module supports 2
independent I ard slots, support Xcrypt
A scramble, compatible with mainstream
AM cards, and support mainstream AS
decryption

OmniHub MP203– User Manual
Page 15 of 109
Section 2 nstallation
SECTION 2 INSTALLATION ..................................................................................................................... 15
2.1 RACK INSTALLATION..........................................................................................................................16
2.2 AC POWER CONNECTION ..................................................................................................................16

OmniHub MP203– User Manual
Page 16 of 109
2.1 Rack nstallation
The OmniHub MP203 is designed to be mounted in a standard 19” rack. It takes 1RU
of rack space. To install it into a rack, please use the following steps:
• Determine the desired position in the rack for the MP203. Make sure that the air
intake on the front of the unit and the exhausts on the back of the unit will not be
blocked.
• Install the brackets at desired position if there’s no supporting plate in the rack.
• Insert the rack mount clips into place over the mounting holes in the rack.
• Slide the MP203 into the position in the rack.
• Secure the chassis to the rack by installing the four supplied screws through the
front mounting holes and tightening.
2.2 AC Power Connection
The OmniHub MP203 to be powered by supplies with operating 120V or 240V systems.
The power supply will automatically detect the system it is connected to. To hook up the
power use the following steps:
• Locate the power cords that are included. Please only use the supplied 3-prong
power connector or one with equal specifications. NEVER tamper with or remove
the grounding pin. This could cause damage to MP203, personnel, or property.
• Plug the female end of the power cords into the front of the unit.
• Locate a protected outlet to plug the male ends of the power cables into.

OmniHub MP203– User Manual
Page 17 of 109
When you take the equipment from a cold condition into a much warmer and
humid condition, the equipment should be acclimated to the warm and humidity
condition for at least 30 minutes. Powering up a non-acclimated unit may lead to
shortcut or other damage to electronic components.
A professional UPS system is recommended for better performance of your
content distribution system.

OmniHub MP203– User Manual
Page 18 of 109
Section 3 Web nterface Operation
SECTION 3 WEB INTERFACE OPERATION ............................................................................................... 18
3.1 OMNIHUB CMP203 WEB INTERFACE OVERVIEW ..................................................................................19
3.1.1 Connecting to the Management Port .....................................................................................19
3.1.2 LOGGING INTO THE CMP203 WEB INTERFACE ......................................................................................19
3.2 STATUS OVERVIEW ...........................................................................................................................19
3.2.1 STATUS ..........................................................................................................................................20
3.2.2 SYSTEM SETTING ..............................................................................................................................21
3.2.3 IP INPUT ........................................................................................................................................23
3.2.4 IP OUTPUT .....................................................................................................................................2
3.3 MODULE CONFIGURATION .................................................................................................................31
RECEIVER MODULES ......................................................................................................................................31
3.3.1 CR2-DVBC-00...........................................................................................................................31
3.3.2 CR2-DVBC-01...........................................................................................................................36
3.3.3 CR2-DVBS2CI-00 ......................................................................................................................37
3.3.4 CR2-DVBS2 TA-00/00A ...........................................................................................................38
3.3.5 CR2-8VSB-00 ...........................................................................................................................38
3.3.5.1 Module Status ....................................................................................................................39
3.3.5.2 Module Settings ..................................................................................................................39
3.3.6 CR2-DVBT2CI-00 ......................................................................................................................43
ENCODER MODULES ......................................................................................................................................45
3.3.7 CE2-HDMI-00/R01 ...................................................................................................................45
3.3.8 CE2-HDMI-02 ..........................................................................................................................53
3.3.9 CE2-HDMI-02C ........................................................................................................................57
3.3.10 CE2-HDMI-05/05A ..............................................................................................................61
3.3.11 CE2-SDI-00 ..........................................................................................................................65
3.3.12 CE2-CVBS-00/R01/R01A .....................................................................................................68
MODULATION MODULES ................................................................................................................................ 2
3.3.13 CM2-QAMA-00/R00 ...........................................................................................................72
3.3.14 CM2-QAMA-R01/R01A .......................................................................................................76
3.3.15 CM2-QAMB-00/R00 ............................................................................................................77
3.3.16 CM2-QAMB-R01/R01A .......................................................................................................78
3.3.17 CM2-8VSB-R01/R01A .........................................................................................................78
3.3.18 CM2-O DM-R01/R01A .......................................................................................................79
3.3.19 CM2-ISDBT-R01/R01A ........................................................................................................80
FUNCTION MODULES .....................................................................................................................................82
3.3.20 CP2-EAS-00 .........................................................................................................................82
3.3.21 CP2-CAM-00 .......................................................................................................................86

OmniHub MP203– User Manual
Page 19 of 109
3.1 OmniHub CMP203 Web nterface Overview
3.1.1 Connecting to the Management Port
MP203 has an embedded gigabit switch inside the chassis. The four network ports are
respectively used for managing and data reception/streaming over IP network. From left
to right, port 1 and port 2 are used for management purposes and, port 3 and port 4 are
used for IP reception/streaming.
If external IP switch needs to install between MP203 and other headend devices, this
switch should support IGMP V2 and IGMP snooping function.
3.1.2 Logging into the CMP203 Web nterface
To open the MP203 web interface use one of the following supported browsers and
navigate to the unit’s IP address:
• Firefox
• Google hrome
Factory network settings of the Management Port:
• IP address: 192.168.1.10
• Subnet Mask: 255.255.255.0
• Gateway: 192.168.1.254
The user will need to login to the web interface. The default username and password
are admin/admin. Press the login button in order to login to the web interface.
3.2 Status Overview
After a successful login, a welcome screen is displayed. The welcome screen allows you
to navigate to:
1. Module List shows the module(s) installed inside the chassis
2. Settings buttons: status, system settings, IP inputs, IP outputs, admin
3. Device host operation status

OmniHub MP203– User Manual
Page 20 of 109
At any time, the user can return to the welcome screen by clicking the Status button and
then Device Status button. Below is the picture displaying Status View for
MP203 front and rear view.
3.2.1 Status
This Menu allow the user to access the following:
• Device Status
• Device Information
Device Status will show once you login on the MP203 management GUI as shown in
the picture above. It also shows the front and rear-view image of MP203 with friendly
label that show the status of each module connected in the 6 slots.
Device nformation page shows the firmware version, software version, and hardware
version of baseboard and every module physically installed. User can access Device
Information status page by clicking the Status button and then Device
information button.