LED (Green) RUN (CANOPEN) Meaning
LED (Green) Tx (MODBUS) Meaning
Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other European
countries with separate collections programs). This symbol, found on your producr or on its packaging, indicates
that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be
handed over to an applicable collection point for the recycling of electrical & electronic equipment. By ensuring this
product is didposed of correctly, you will help prevent potential negative consequences to the environment and
human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of materials
will help to conserve natural resources. For more detailed information about the recycling of the product, please
contact your local city office, waste disposal service of the retail store where you purchased this product.
LED RUN (Green)
LED RUN (Green)
STATE
Single flash
On
Blinking
ON
Pre-operational
Operational
The Device is in the PRE-OPERATIONAL state.
The Device is in the OPERATIONAL state.
The device is transmitting.
Stop The Device is in STOPPED state.
All DIP-switch OFF:
- MODBUS Protocol / - Communication parameters: 38400 8,N,1 Addr. 1
- In case of fail, outputs go low.
- Modbus communication monitoring, not active.
All dip switch OFF except and :SW2 (ON) SW4 (ON)
- CANopen Protocol / - Communication parameters: 20K Addr. 127
- In case of fail, outputs go low.
Variations of standard parameters are possible by using configuration softwares Z-NET
and EASY-Z-PC (www.seneca.it).
FACTORY SETTINGS
MI001523-E ENGLISH 8/8
LEDS FAIL AND PWR: GENERAL SYSTEM DIAGNOSTICS
LEDS 01..24: DIGITAL OUTPUTS STATE
LED 01..24
(Green) Meaning
LED PWR
(Green) Meaning LED FAIL
(Yellow) Meaning
The corresponding output (01..24) is ON.
ON
ON
ON /
Blinking
Power Supply Presence
- Data reception on the
RS232 port (COM).
- Fault: at least an output
is in fault condition.