manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sengate
  6. •
  7. Desktop
  8. •
  9. Sengate TA-130-100 User manual

Sengate TA-130-100 User manual

1
100M/150M/200M/250 /300M M GROUND TOWER
anchor bolts
(M10x120) x4
hex nuts
(M10) x12
flat washer
(M10) x4
sleeve anchors
(3/8"x 3") x4
TA-130-100 / TA130-150 / TA130-200 / TA130-250 / TA130-300
TA-120-100 / TA120-150 / TA120-200 / TA120-250 / TA120-300
MANUAL INSTRUCTION
Thanks for purchasing product. Read this instruction manual before using the product to make sure that you u e it correctly.s
PRODUCT PARTS:
PARTS DESCRIPTION
INSTALLATION METHOD:
2
top cover
top cover
alum-extrusion
side bracket
tamper switch
U-shaped
cover
single-sided tower double-sided tower
floor base unit x1
Optional Accessory
Heating Unit : HT-120
1. In one of the two top covers, for wiring.
2. Place the nuts in the top covers and insert the hex screw, screwing them slightly. Put the top cover onto the aluminium profile,
and tighten bolts fully.
3. Slide the hex screw along the alum-extrusion and then fix the side brackets with nut to it.
drill holes in the marked areas to allow
hex screw
(M8x16)
hex screw
(M8x16)
hex screw
(M4x10)
nuts (M4) nuts (M8)
4. After the alum and side brackets installed on the ground, according to priority, fix the heating unit, back plate of beam unit then
the supplied tamper switch near the top of the alum-extrusion.
5. Be sure the tamper switch should be flush with the arm of tamper switch rests above the top line of the alum.
tamper switch
back plate of
beam unit
heating
unit
( the priority of installation ) heating units
( optional )
the edge
should be
flush-with.
the arm of tamper switch
rests above the top line
of the alum.
2
EXTERNAL DIMEN IONS: S
3
9.87"
[250.6]
9.87"
[250.6]
9.53"
( L)
[242]
( L)
9.53"
[242]
8.78"
( L)
[223]
4.72"
7.30" [120]
[185.3]
8.78"
( L)
[223]
7.20"
3.15"
[183]
[80]
3.15"
[80]
7.20"
[183]
7.56"
5.91"
[192]
[150]
7.56"
5.91"
[192]
[150]
TA-130-100 (L=1000 mm)
TA-130-150 (L=1500 mm)
TA-130-100 / TA-130-150
TA-120-100 (L=1000 mm)
TA-120-150 (L=1500 mm)
TA-120-100 / TA-120-150
TA-130-200 (L=2000 mm)
TA-130-250 (L=2500 mm)
TA-130-300 (L=3000 mm)
TA-130-200 / TA-130-250
TA-130-300
TA-120-200 / TA-120-250
TA-120-300
TA-120-200 (L=2000 mm)
TA-120-250 (L=2500 mm)
TA-120-300 (L=3000 mm)
No:A064B02-00
Unit : [inch mm]
7.87"
8.87" [200]
[225.3]
b. anchor bolts
a. sleeve anchors
NOTE :
1. This unit is designed to detect intruder and activate alarm control panel. Being only a part of complete system,
we cannot assume responsibility for theft or damages, should it occur.
2. Specifications and design are subjected to change without prior notice.
3. No take apart the product improperly, which possibly cause the damage.
6. Wire and fix side brackets to the floor using:
a.Sleeve Anchors : Ø1/2″(12.7 mm)
fix optional side brackets and tighten sleeve anchors fully.
b.Anchor Bolts : Slide anchor bolts and M10 hex nuts along the floor base unit, embedding the floor base unit into concrete.
Special attention is required when anchoring to uneven surface, be sure a level is used. Few days later,
set side brackets, slide M10 washer/hex nut and tighten fully.【Be sure a level is used】
Making mark and drilling where tower designated to mount into concrete,
drilling and
marking
sleeve anchors
(3/8"x3")
floor base
short side bracket Mark
“ 2” hole (183x80mm)
long side bracket using Mark
“ 1” hole (192x150mm)
hex nuts
(M10)
anchor bolts
use a Level
washers
(M10)
hex nuts
(M10)
7. You can attach and align the beam units to the back plates. Do not fit the original beam covers to the beam units.
8.Mount the polycarbonate profile, inserting and sliding it along the Alum-Extrusion.
9. Place the nuts in the top cover and insert the hexscrew, screwing them slightly.
Put the top cover on the alum-extrusion, and tighten bolts fully.
Do not fit the
original beam
covers to the
beam units.
Web Site : http://www.sengate.com
E-Mail : service @ sengate.com
Designing / Manufacturing
Taiwan Security Net Co., Ltd. Designing / Manufacturing
Taiwan Security Net Co., Ltd.
No.4-46,Feng-Jen Road, Renwu, Kaohsiung, 81459, Taiwan
TEL 886-7-3721111 FAX 886-7-3728650 : :

This manual suits for next models

9

Popular Desktop manuals by other brands

Lenovo NetVista A20 user manual

Lenovo

Lenovo NetVista A20 user manual

HP Kayak XW A2-U2-W2 user guide

HP

HP Kayak XW A2-U2-W2 user guide

HP Xw4550 - Workstation - 2 GB RAM Quickspecs

HP

HP Xw4550 - Workstation - 2 GB RAM Quickspecs

Arbor Technology LYNC-817 Series user manual

Arbor Technology

Arbor Technology LYNC-817 Series user manual

Vensmile W10 instruction manual

Vensmile

Vensmile W10 instruction manual

HP Pavilion v600 - Desktop PC Technical specifications

HP

HP Pavilion v600 - Desktop PC Technical specifications

Dell OptiPlex 160 Service manual

Dell

Dell OptiPlex 160 Service manual

Lenovo ThinkCentre M73z Hardware Maintenance Manual

Lenovo

Lenovo ThinkCentre M73z Hardware Maintenance Manual

Lenovo ThinkStation D30 Používateľská príručka

Lenovo

Lenovo ThinkStation D30 Používateľská príručka

Apricot MS Series owner's guide

Apricot

Apricot MS Series owner's guide

IBM A50 user guide

IBM

IBM A50 user guide

Mega 65 Welcome guide

Mega

Mega 65 Welcome guide

Casio FX-795P owner's manual

Casio

Casio FX-795P owner's manual

HP Compaq Presario supplementary guide

HP

HP Compaq Presario supplementary guide

Sun Microsystems Ultra 10 Getting started guide

Sun Microsystems

Sun Microsystems Ultra 10 Getting started guide

Intergraph Zx10 Ultra-Tower manual 

Intergraph

Intergraph Zx10 Ultra-Tower manual 

Lenovo ThinkCentre A51 Quick reference guide

Lenovo

Lenovo ThinkCentre A51 Quick reference guide

Biotage TurboVap 96 user manual

Biotage

Biotage TurboVap 96 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.