SenseNet control4all Manual

2014
Roger Althaus
control4all
13.06.2014
control4 GSM Gateway Setup

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
Table of content
General ...................................................................................................................................................................................2
Introduction ....................................................................................................................................................................2
Features.............................................................................................................................................................................2
Supported Hardware and Software.......................................................................................................................2
Limitations ..................................................................................................................................................................2
Installation............................................................................................................................................................................3
Installing the Hardware..............................................................................................................................................3
Configuration.......................................................................................................................................................................4
Prepare control4 System............................................................................................................................................4
Configure GSM Gateway .............................................................................................................................................5
Logon to Gateway.....................................................................................................................................................5
Network Settings ......................................................................................................................................................5
Route Settings............................................................................................................................................................6
SIP Settings..................................................................................................................................................................8
Troubleshoot.....................................................................................................................................................................10

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
General
Introduction
This Document describes the integration of the control4all Mobile Gateway into a control4
system.
Features
-Ring to a external Phone when someone is Ringing at the Doorstation with 2-way Audio.*
-Trigger the Door Relay to open the Door. *
-Ring from a external Phone to a Panel or Intercom Group.
-Sending Text Messages, in development ***
Supported Hardware and Software
Currently tested and supported:
-control4 Software Version 2.5.3
-Koch Door Station
-control4all Mobile Gateway MV-370 (Special Firmware)
-control4 In-Wall 7" Touch Screen V2 **
Limitations
* tested with Koch Doorstation
** only inbound calls, outbound audio fails.
***= Requires Driver

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
Installation
Installing the Hardware
Unpack the Device
Open the cover on the Backside
Locate the SIM Card Slot
Place the Card that the Edge of the Card is right in front to you
Close the Cover
Connect the Antenna, Ethernet and Power Supply.

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
Configuration
Prepare control4 System
Launch Composer
Connect to Controller
Goto “System Design”
Add „3rd Party SIP Phone“ Driver to Project
Enter desired Username and Password
(i.e. User “100” and Password “1234”)
Click “Apply”

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
Configure GSM Gateway
Logon to Gateway
Launch Webbrowser
Open http://<ip_of_gateway> and the Logon-Window appears
(default: 192.168.0.100)
Enter Default Username “voip” and Password “1234”
Click “Login”
Network Settings
Verify Network Settings. We recommend to use static IP Address Configuration.

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
Route Settings
LAN to Mobile
Position
0
URL
* = any IP allowed to Dial, or i.e. Subnet 192.168.3 only.
CallNum
Number to dial

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
Mobile to LAN
If you want to be able to make Inbound Calls (i.e. to a Touch-Panel) apply these Settings
otherwise leave the Table blank.
Item
The Rule Number. The Fist matching is taken
CID
Caller ID. If you put a “*” any call is accepted.
URL
The Format is:
-<panel_mac_id>@<controller_ip> for a Single Panel
-<intercom_group>@<controller_ip> for a Intercom Group

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
SIP Settings
Service Domain
Active
ON
Display Name
“SIP User Name” specified in Composer
User Name
“SIP User Name” specified in Composer
Register Name
“SIP User Name” specified in Composer
Register Password
“SIP User Password” specified in Composer
Domain Server
Leave blank
Proxy Server
Enter IP of control4 controller
Outbound Proxy
Leave blank
Status
After rebooting the Gateway check the status is “Registered”.
Otherwise check Username/Password.
DTMF Setting
These Settings are important if you want to able to trigger the Relay on the Koch-Doorstation.
This can be done by pressing “*7” on the called phone.

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
SIP Response Setting
Due an incompatibility on the control4 SIP implementation make sure that ”183 Session in
Progress” is set to OFF.
All other Settings on the Gateway can be left as default.

control4all by SenseNet GmbH |Guldifeld 42 |3182 Ueberstorf |031 742 11 21 |
www.control4all.ch
Troubleshoot
Check Mobile
Status
Check SIP Settings
Status must be registered