Sentinel ELIMINATOR User manual

1
Eliminator
EN Central Heating Filter Installation Manual 3
FR Filtre pour chauffage central Manuel d’installation 13
IT Filtro per impianti di riscaldamento Manuale d’installazione 23
ES Manual de instalación de filtro para calefacción central 33
V2-CM-03-17
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 1 14/03/2017 14:20

Eliminator V2-CM- 03-172
IMPORTANT
Please retain these instructions for reference during servicing
IMPORTANT
Conservez ce manuel d’utilisation comme référence lors des
opérations de maintenance
IMPORTANTE!
Si prega di conservare queste istruzioni come riferimento durante
le operazioni di manutenzione
IMPORTANTE
Por favor conserve estas instrucciones para referencia durante
trabajos de servicio
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 2 14/03/2017 14:20

Eliminator V2-CM- 03-17
EN
3
SCHEMATIC DIAGRAM
For product demonstration please view on You Tube or via www.sentinelprotects.com/uk/eliminator
Directional T piece
Flow arrow
Dual seals
Bleed valve
Isolation valve
Isolation valve
Collar
Collection bin
Cyclone
cartridge
Magnet tray
Anti tamper drain valve
Washer
Fig. 1
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 3 14/03/2017 14:20

Eliminator V2-CM- 03-17
EN
4
SAFETY CONSIDERATIONS
Caution: Strong magnetic field.
The Sentinel Eliminator® is a vessel under pressure containing a hot fluid. It is
recommended that it is installed by a suitably qualified person.
Always ensure that the system has cooled before attempting installation. Check
very carefully for any leaks after fitting the filter and pressurising the system.
The T-piece collar must be hand tightened only; do not attempt to use a tool as
this could damage the seal.
Care should be taken when flushing a hot system.
SYSTEM DESIGN
The Sentinel Eliminator is suitable for use on all wet central heating systems.
The cyclones are not optimsed for flow rates above 25 litres per minute.
The Sentinel Eliminator is rigorously tested to confirm it meets the temperature
and pressure requirements of a typical domestic system.
The filter should be preferably mounted on the boiler return pipe only.
The Sentinel Eliminator is compatible with the full Sentinel chemical range.
For full system protection it is recommended that the system be cleaned prior
to fitting the filter and Sentinel X100 Inhibitor be added to prevent corrosion
and the formation of limescale.
MOUNTING CONSIDERATIONS
Before fitting the filter, ensure that adequate clearance is available, including
the vertical space required to drain the filter during servicing.
The filter can be fitted to either horizontal or vertical pipe-work by rotating the
T-piece. Regardless of the pipe-work orientation, the filter body must be orientated
vertically. IMPORTANT: Ensure that T-piece is aligned to the direction of flow.
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 4 14/03/2017 14:20

Eliminator V2-CM- 03-17
EN
5
INSTALLATION PROCEDURE
Step 1:
Ensure heating system is turned off and drained.
Step 2:
Position filter on return pipe close to boiler, as per Figure 2.
Step 3:
Attach drain valve to filter in closed position, as per Figure 3.
Boiler
Fig. 2
Washer
Fig. 3
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 5 14/03/2017 14:20

Eliminator V2-CM- 03-17
EN
6
Step 4:
Remove 195mm from pipe in chosen location and attach isolation valves to cut
ends as per Figure 4. Note that the pipe can be horizontal or vertical, but the final
filter position must always be vertical.
Step 5:
Attach the filter to pipe work. Ensure that the supplied washers are in place,
sealing the valves to the plastic T-piece. Ensure filter is mounted vertically by
loosening the collar and rotating the filter body as required. Re-tighten the collar
by hand, checking the flow direction on the T-piece, as per Figure 5.
Step 6:
Set Isolation valves to open, as per Figure 6.
Fig. 4 Fig. 5
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 6 14/03/2017 14:20

Eliminator V2-CM- 03-17
EN
7
Step 7:
Refill system and check carefully for
any leaks.
Step 8:
After filling the system with water,
open bleed valve using a suitable
screwdriver to release air trapped in
filter. Once water starts to escape,
close valve. After the system has
been running, repeat if nessesary to
release any trapped air. Check again
for leaks.
Open
Fig. 6
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 7 14/03/2017 14:20

Eliminator V2-CM- 03-17
EN
8
DRAIN VALVE OPERATION
To Open:
Remove end cap from bottom of
valve. Remove retaining nut, take off
handle and flip over. Replace handle
and turn to open valve, as per Figures
7 & 8.
To Close:
Turn valve to closed position, take off
handle, flip over and replace retaining
nut. Replace end cap.
BLEED VALVE OPERATION
After filling the system with water,
open bleed valve using a suitable
screwdriver to release air trapped in
filter. Once water starts to escape,
close valve. After the system has
been running for several hours,
repeat to release any trapped air.
Nut
Fig. 7
Nut
Fig. 8
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 8 14/03/2017 14:20

9Eliminator V2- CM-0 3-17
EN
SERVICING
Sentinel recommend that cleaning is carried out during the annual system
service.
Step 1:
Ensure heating system is turned off and allowed to cool prior to commencing
clean.
Step 2:
Squeeze to disengage magnetic tray, as per Figure 9.
Step 3:
Place suitable container under drain valve, as per Figure 10. Open drain valve
(see page 8). Close drain valve and re-engage magnetic tray. There is also an
option to clean by opening the bin.
Optional Removal of Bin
Close both isolation valves, allow drain water to stop flowing. Unscrew bin
to carry out thorough clean, as per Figure 11. After cleaning, replace bin and
tighten by hand. Close drain valve, re-engage magnetic tray, and open both
isolation valves to fill filter and release any trapped air using the bleed valve
(see page 8).
It is recommended after a filter flush to carry out an inhibitor test such as
Sentinel X100 Quick Test and top up with Sentinel X100 Inhibitor if required.
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 9 14/03/2017 14:20

Eliminator V2-CM- 03-17
EN
10
Fig. 9
Fig. 10
Closed
Fig. 11
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 10 14/03/2017 14:20

Eliminator V2-CM- 03-17
EN
11
GUARANTEE REGISTRATION
Please complete and return the form opposite to Sentinel to register for your
10 year guarantee. Alternatively, you can register online at
http://www.sentinelprotects.com/uk/guarantee-registration
and select Eliminator. Full Terms and Conditions can also be found on the
website.
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 11 14/03/2017 14:20

EN
GUARANTEE REGISTRATION
Please complete and return to register your 10 year guarantee.
Occupier
Name
Address
Postcode Telephone
Email
Sentinel Performance Solutions Ltd and its sister companies may wish to send you information on
products, services and promotions in the future. If you would like to receive communications please tick
here – via Post Email Telephone
Sentinel Performance Solutions Ltd and its sister companies may wish to send you information on
products, services and promotions in the future. If you would like to receive communications please tick
here – via Post Email Telephone
Installer
Installer Name/Company
Address
Postcode Telephone
Email
Place of purchase
Date of purchase Date of installation
RETURN COMPLETED FORM TO:
Eliminator
Central Heating Filter
Sentinel Performance Solutions Ltd, 7650 Daresbury Park, Warrington, Cheshire, WA4 4BS
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 12 14/03/2017 14:20

Eliminator V2-CM- 03-17
FR
GUARANTEE REGISTRATION
Please complete and return to register your 10 year guarantee.
Occupier
Name
Address
Postcode Telephone
Email
Sentinel Performance Solutions Ltd and its sister companies may wish to send you information on
products, services and promotions in the future. If you would like to receive communications please tick
here – via Post Email Telephone
Sentinel Performance Solutions Ltd and its sister companies may wish to send you information on
products, services and promotions in the future. If you would like to receive communications please tick
here – via Post Email Telephone
Installer
Installer Name/Company
Address
Postcode Telephone
Email
Place of purchase
Date of purchase Date of installation
RETURN COMPLETED FORM TO:
Eliminator
Central Heating Filter
Sentinel Performance Solutions Ltd, 7650 Daresbury Park, Warrington, Cheshire, WA4 4BS
13
SCHÉMA
Visualisez le filtre Eliminator en images sur Youtube ou sur www.sentinelprotects.com
T de connexion avec
flèche de sens de
circulation de l’eau
Doubles joints
Purgeur
Collet
(d’orientation
du filtre)
Réservoir à débris
Cartouche
cyclonique
Collecteur magnétique
Vanne de vidange sécurisée
Joint
Vanne d'isolement
Vanne d'isolement
Fig. 1
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 13 14/03/2017 14:20

Eliminator V2-CM- 03-17
FR
14
RECOMMANDATIONS DE SÉCURITÉ
Attention : Champs magnétique puissant.
Le filtre Sentinel Eliminator® est un équipement sous pression contenant du
fluide chaud. Il est recommandé qu’il soit installé par un professionnel qualifié.
Avant toute installation, toujours s’assurer que l’installation ait refroidi. Vérifier
soigneusement qu’il n’ y a pas de fuites après l’installation du filtre et la mise
sous pression du circuit.
Le T de connexion doit être serré à la main uniquement. Ne pas utiliser d’outils
pour le serrage, sous peine d’endommager le joint.
Soyez prudent lorsque vous rincez une installation chaude.
CONCEPTION DU FILTRE
Le filtre Sentinel Eliminator est destiné à être utilisé dans toutes les
installations de chauffage central. Les cyclones ne sont pas optimisés pour des
débits supérieurs à 25 litres par minute.
Le filtre Sentinel Eliminator a été rigoureusement testé pour démontrer
sa compatibilité avec les exigences de température et de pression d’une
installation domestique typîque.
Le filtre doit être installé de préférence sur le retour de la chaudière.
Le filtre Sentinel Eliminator est compatible avec les additifs de la gamme
Sentinel. Pour une protection durable de l’installation, il est recommandé de
la nettoyer avant d’installer le filtre et d’ajouter l’inhibiteur Sentinel X100 pour
prévenir la formation de corrosion et de calcaire.
RECOMMANDATIONS DE MONTAGE
Avant d’installer le filtre, assurez-vous que l’espace disponible est suffisant, y
compris l’espace vertical nécessaire pour vidanger le filtre lors de la maintenance.
Le filtre peut être installé sur une tuyauterie horizontale ou verticale en faisant
juste pivoter le T de connexion. Qu’elle que soit l’orientation de la tuyauterie, le
corps du filtre doit être positionné verticalement. IMPORTANT : Assurez-vous que
le T de connesion est positionné de telle sorte que la circulation de l’eau se fasse
dans le même sens que la flèche sur le filtre.
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 14 14/03/2017 14:20

Eliminator V2-CM- 03-17
FR
15
PROCÉDURE D’INSTALLATION
Étape 1 :
S’assurer que la chaudière est éteinte et l’installation vidangée.
Étape 2 :
Monter le filtre sur le retour, au plus près de la chaudière, comme sur la Figure 2.
Étape 3 :
Raccorder la vanne de vidange au filtre, en position fermée, comme sur la
Figure 3.
Chaudière
Fig. 2
Joint
Fig. 3
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 15 14/03/2017 14:20

Eliminator V2-CM- 03-17
FR
16
Étape 4 :
Raccords à visser Mâle ¾" : cette vanne d’isolement ¾" est une vanne ¾" BSP
avec raccord union à visser mâle. Couper le tuyau à l’emplacement choisi et fixer
les vannes d’isolement à chaque extrémité, comme sur la figure 4.
Ou :
Raccords olive 22mm : Couper 195mm à l’emplacement choisi et fixer les vannes
d’isolement à chaque extrémité, comme sur la figure 5. NB : Bien que le tuyau
puisse être horizontal ou vertical, la position finale du filtre doit toujours être
verticale. Avant de procéder à la découpe des tuyaux, n’oubliez pas de prendre en
compte la dimension des raccords supplémentaires, si nécessaire.
Étape 5 :
Fixer le filtre sur la tuyauterie. Veillez à installer les joints fournis, pour assurer
l’étanchéité des vannes sur le T de connexion. Positionner le filtre à la verticale
218mm
Fig. 4
195mm
Fig. 5
Ou
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 16 14/03/2017 14:20

Eliminator V2-CM- 03-17
FR
Fig. 6
17
en desserrant le collet et en faisant pivoter le corps du filtre jusqu’à la bonne
position. Reserrer le collet à la main, en vérifiant le sens de circulation sur le T de
connexion, comme sur la Figure 6.
Étape 6 :
Ouvrir les vannes d’isolement, comme sur la Figure 7.
Étape 7 :
Remplir l’installation et vérifier attentivement qu’il n’y a pas de fuites.
Étape 8 :
Après la remise en eau de l’installation, ouvrir le purgeur à l’aide d’un tournevis
adapté pour libérer l’air piégé dans le filtre. Dès que l’eau commence à couler,
fermer le purgeur. Après plusieurs heures de fonctionnement, libérer l’air
emprisonné à l’aide du purgeur et vérifier de nouveau qu’il n’y a aucune fuite.
Ouvert
Fig. 7
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 17 14/03/2017 14:20

Eliminator V2-CM- 03-17
FR
18
FONCTIONNEMENT DE LA VANNE
DE VIDANGE
Pour ouvrir :
Retirer le capuchon. Utiliser une clé à
mollette pour retirer l’écrou. Tirer la
poignée, la faire pivoter, replacer puis
tourner pour ouvrir la vanne, comme
sur les Figures 8 et 9.
Pour fermer :
Mettre la vanne en position fermée,
tirer la poignée, tourner et remettre
en place. Revisser l’écrou et remettre
en place le capuchon.
FONCTIONNEMENT DU PURGEUR
Après la remise en eau de
l’installation, ouvrir le purgeur à l’aide
d’un tournevis adapté pour libérer
l’air piégé dans le filtre. Dès que
l’eau commence à couler, fermer le
purgeur. Après plusieurs heures de
fonctionnement, libérer l’air
emprisonné à l’aide du purgeur.
Écrou
Fig. 8
Écrou
Fig. 9
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 18 14/03/2017 14:20

19Eliminator V2-CM- 03-17
FR
MAINTENANCE
Sentinel recommande d’effectuer le nettoyage du filtre lors de la visite de
maintenance annuelle de l’installation.
Étape 1 :
S’assurer que la chaudière est éteinte et laisser refroidir l’installation, avant de
commencer le nettoyage.
Étape 2 :
Faire coulisser le collecteur magnétique, comme sur la Figure 10.
Étape 3 :
Placer un récipient adapté sous la vanne de vidange, comme sur la Figure 11.
Ouvrir la vanne de vidange (voir page 18). Puis refermer la vanne de vidange
et enclencher le collecteur magnétique a. Il existe une autre possibilité de
nettoyage en dévissant le réservoir à débris.
Dépose facultative du réservoir à débris
Fermer les deux vannes d’isolement pour arrêter l’écoulement de l’eau.
Dévisser le réservoir à débris pour effectuer un nettoyage complet, comme sur
la Figure 12. Une fois le nettoyage terminé, revisser le réservoir et serrer à la
main. Puis, refermer la vanne de vidange, enclencher le collecteur magnétique
et ouvrir les vannes d’isolement afin de remplir le filtre. Libérer tout l’air piégé à
l’aide du purgeur (voir page 18).
Après un nettoyage du filtre, il est recommandé de vérifier la pression de
l’installation et le bon dosage d’inhibiteur, à l’aide du Sentinel X100 Quick Test,
avant de remettre l’installation en service. Faire l’appoint d’Inhibiteur Sentinel
X100, si nécessaire.
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 19 14/03/2017 14:20

Eliminator V2-CM- 03-17
FR
20
Fig. 10
Fig. 11
Fermé
Fig. 12
Eliminator Instructions V1-CM (14-03-17) (inc Spanish).indd 20 14/03/2017 14:21
Other manuals for ELIMINATOR
1
Table of contents
Languages:
Other Sentinel Heating System manuals
Popular Heating System manuals by other brands

Viessmann
Viessmann VITOTRONIC 200 operating instructions

Envirovent
Envirovent energiSava 325 Installation guide for engineer / installer

Daikin
Daikin EHBX04C3V Technical data

Viessmann
Viessmann VITOBLOC 200 Technical description

Roberts Gorden
Roberts Gorden CRV-Series Installation & operation

Bromic Heating
Bromic Heating SMART-HEAT CONNECT Setup and user's manual