Sentinel ICG-30 User manual

SANTA ROSA, CALIFORNIA

2 3
There are two different ICG-30 units, one is used for
Propane (ICG-30LP) and one is used for Natural Gas (ICG-30NG).
Below are the differences between the two units. Make sure you have
selected the correct unit and are using the matching fuel supply.
• Forsafety,itisrecommendedtoalwaysuseaSentinelCo2monitor/controller
withtheunittomeasurecurrentCo2gaslevelsintheenvironment.Levels
over2,000PPMshouldbeavoided.
• Mountunitsecurelyinahangingpositionusingthehardwareprovided.
Maintainaminimumof20”ofclearanceonallsidesoftheunit.DONOT
PLACEUNITONGROUND/TABLEETC.
• NG/LPgasesaredangerous–Checkallfittingsbysprayingwithsoapywater
before operating unit
• Ifgasissmelled,immediatelyunplugunitandventilatethearea.Checkall
connections again.
• Alwaysdisconnectpowertotheunitbeforeusingfoggersorbugbombs.
• Unitgetsextremelyhotwheninoperation.Topreventburns,donottouchthe
unit.Donotallowflammableobjectstocomeintocontactwiththeunit.
• Thisunitshallnotbeexposedtodripping,splashingorsprayingofliquids.
Protectunitfromvapors,foggersetc.
• Cleanunitwithcleandrycloth,nooilsorsolvents
• Donotputpaperclips,toolsetcinsideunitopeningsorreceptacles.Possible
fire,shockordeathmayoccur.
• Verifypowersourcepriortoconnectingunittopowersourceand/orCO2
controller or timer
• UseonlySentinelsuppliedpowersupplytooperatetheunit.Useofanyother
powersupplywillvoidwarranty,andcouldcauseapossiblesafetyhazard.
• Protectanypowercordsfrombeingwalkedon,pinchedorcrushed
• Protectanygassupplyhosesfrombeingwalkedon,pinchedorcrushed
• Allbrassfittingsareflarefittingsandself-sealing.DonotuseTeflontapeon
gas connections.
• Unitistobeusedwithindefinedenvironmentalparameters
• Usecautionwhenoperatinginhighhumidityenvironments
• Thisunitcontainsnouser-serviceableparts.Donotattempttoservicethis
product. Breaking any warranty seal will void warranty.
ICG-30LP: Liquid Propane,otherwise
known as LP or Propane, is stored in
pressurized tanks of varying sizes.
The gas exiting the pressurized tank
must first be regulated to a very low
pressurebeforeitenterstheICG-30.
The standard for measuring the low
pressure is inches of water column
orInch/WC.TheICG-30LPoperates
at11”WC,orabout1/2PSI(2.8kPa).
The LP regulator provided with the
unitMUSTbeusedunlessitisverified
that the propane gas supply is already
regulatedto11”WC.TheprovidedLP
regulator is designed to connect di-
rectlytoportableLPtanks.Italsohas
a built-in safety function that limits
the flow of gas to a very low level in
the event of a large gas leak.
OncetheLPgasisregulateddownto
thecorrectpressure,itenterstheunit
and flows through solenoid valves and
theproprietarySentinelstainlesssteel
burnerassembly.TheSentinelburner
assembly is designed to be the most
efficient, cleanest burning CO2 gen-
erator available to today’s gardeners.
ItistheONLYCO2generatorburner
weareawareofwithalowNOXde-
sign. The 3 stage design allows the
ICG-30LP to have a Co2 output of
10.6,21.2and31.8cuft/hour.These
modeswillcreate9,000,18,000and
27,000BTU/hrorheat,andalarge
amount of water vapor.
ICG-30NG: Natural Gas, otherwise
known as NG, is piped directly into
homesandbusinessesfromanexten-
sive pipeline system. The gas supply
entering the building can vary from
verylowpressure(lessthan1/4 PSI)
toover5PSI.TheNGprovidedtothe
ICG-30NGmustfirstbe regulatedto
a very low pressure before it enters
theunit.Thestandardformeasuring
the low pressure is inches of water
columnorInch/WC.TheICG-30NG
operatesat4.5”WC,orabout1/4PSI
(1.15kPa).TheNGregulatorprovided
withtheunitMUSTbeusedunlessit
is verified that the natural gas supply
isalreadyregulatedto4.5”WC.
OncetheNGgasisregulateddownto
thecorrectpressure,itenterstheunit
and flows through the solenoid valves
andtheproprietarySentinelstainless
steel burner assembly. The Sentinel
burner assembly is designed to be the
most efficient, cleanest burning CO2
generator available to today’s gar-
deners.ItistheONLYCO2generator
burnerweareawareofwithalowNOX
design.The3stagedesignallowsthe
ICG-30NGtohaveaCo2outputof9,
18and27cuft/hour.Thesemodes
willcreate9,000,18,000and27,000
BTU/hrorheat,andalargeamount
of water vapor.
ICG-30 LP / ICG-30 NG INSTRUCTIONS
Important Warnings and Cautions
Read all instructions before installation and usage.
Save these instructions.
ICG-30 LP AND ICG-30 NG INTRODUCTION
Sentinel Intelligent Carbon Dioxide Generator
WARNING: Installation and connection of gas lines must be in
compliance with local and national building codes.
ANY QUESTIONS...
Consult a licensed installer or contact Sentinel technical support

45
1. TheICG-30LP/NGisdesignedtohangfromaceilingjoistoroverheadsupport.
Itcomeswithtwoeyebolts,hooksandsectionsofchain.
2. DONOTplacetheICG-30LP/NGontopofsomethinglikeatabletooperateit.
Thegeneratorrequiresafreeflowofaircominginthroughthebottomoftheenclosure.
3. Thechainsprovidedare20”long.Aminimumof20”mustbemaintainedbetween
theICG-30LP/NGandanywallsorotherobstructions.Takecaretomountawayfrom
flammable materials.
4. Installthetwoscrewhooksintoasuitablesupports.Thechainsarethensecuredtothe
ICG-30LP/NGandthescrewhookswiththeincludedShooks.
5. Ensurethattheunitishanginglevel.TheICG-30LP/NGisdesignedwithananti-tip
oversafetyfeature.IntheeventthattheICG-30LP/NGisnotlevelortipsover,the
gas supply and ignition are disabled.
6. Thegasconnectionfittingsmustbetightenedproperly.Thesupplied12foot(4m)hose
isconnectedfromtheflarefittingontheICG-30LP/NGtotheprovidedappropriate
gasregulator.TheflarefittingislocatedonthebottomoftheICG-30LP/NG.Secure
the connection with two wrenches.
Takecarewhenattachingandtighteningthebrassflarefittings.
AllICG-30LP/NGunitsarecheckedandcertifiedfromthefactorytonothave
cross-threadedorstrippedfittings.CrossthreadedorstrippedfittingsARENOT
coveredunderSentinelwarrantyterms.
ThebrassflareconnectionunderneaththeICG-30canbedifficulttogetto.
Pleasebepatient.Ithasbeendesignedthiswaytoprotectthefittinginsidethe
steelcaseduringshippingfromthefactory,andmovingaroundinthegrowroom,
greenhouse or garden during cleaning and maintenance.
7. Oncethegasconnectionsaresecured,pressurizethegaslineandcheckforleaks
usingthesoapywater.Spraythewaterontothegasconnectionfittingsandlookfor
anybubbles.Re-secureifnecessary.
8. AftertheICG-30hasbeenhungproperly,andgasconnectionshavebeenchecked,
testfiretheunit.Plugthelowvoltageconnectionofsupplied24vpoweradaptorinto
theICG-30,andplugthehighvoltageconnectionintoanyNEMA5-15120v/60Hz
receptacle.SwitchthepowerbuttontotheONposition.Pressthemodebutton
(M/S)untilthe“M”(Manualmode)isdisplayedontheICG-30statusscreen.The
ICG-30willturnonandignitetheburner.Note:Sometimesduringinitialinstallation
(andsubsequentLPtankchanges)severalattemptsareneedtoignitetheICG-30
duetoairbeingpurgedoutofthegaslines.Thisisnormal.
9. OncetheICG-30isoperatingproperly,presstheoutputbuttonsupordownto
cyclethroughthedifferentoutputsettings.Itisnormalfor5-10secondstotakeplace
betweenoutputchanges.Notehowtheburnerpatternchangesduringthedifferent
output modes.
10.Ifeverythingisoperatingproperly,switchoffthepowerbuttonandproceedto
“OperatingInstructions”.
INITIAL INSTALLATION INSTRUCTIONS
GETTING TO KNOW YOUR ICG-30
•Variablemulti-modeCO2outputsuptoover31
cubic feet per hour
•NewSentinelproprietarystainlesssteel,
low-NOXburnerassemblyiscleanerandmore
efficientthanANYCO2generator
•SentinelIntelligentignitionandcontrolmodule
eliminates open pilot flames and provides for
maximumsafety
•Tip-overswitchautomaticallyshutsoffunit
•Advanced,multi-stagesolenoidvalveprovides
consistent operation and redundant safety
•Unitcomescompletewithappropriategasvalve
and hose assembly
•RoHScompliantforenvironmentalfriendliness
POWER BUTTON
MODE SWITCH (M/S)
LED STATUS DISPLAY
OUTPUT UP
OUTPUT DOWN
POWER INPUT PORT
Scan this code to learn more about the
Sentinel ICG-30 on your smart phone!

67
A. Operation in the S.I.C.E. (Sentinel Intelligent CO2 Enrichment ™ ) mode
YournewICG-30seriesgeneratoristhemostadvancedCO2generatoravailable
onthemarkettoday.ItincorporatestheproprietaryS.I.C.E.–SentinelIntelligent
CO2Enrichment–communicationandcontrolcomponentsandprogramming
thatareuniquetoSentinel.Thispatentpendingsystemallowsforcommunications
betweenSentinelS.I.C.Eseriesproducts,providingalevelofcontrolneverbefore
seeninyourgreenhouse,gardenorgrowroom.
ThesystemworksbyaSentinelS.I.C.E.seriescontroller,suchastheSentinelCPPM-4i
orSentinelCHHC-4i,measuringandmonitoringyourgrowingenvironment.Asthe
atmosphericCO2levelschange,thecontrollerwilltelltheICGseriesgeneratorto
increaseoutput,decreaseoutput,orgointoidlemode…allcomputercontrolled.
Inthisway,agrowingenvironmentthathasverylowCo2levels,suchasthestart
ofthedayorafteraventilationcycle,canberapidlybroughtbackuptooptimal
growingconditions.Astheoptimalconditionsarereached,theS.I.C.E.systemcan
decreaseCo2output,makingsurethattheuserdefinedoptimallevelisnotovershot.
Asneeded,thegrowingenvironmentcanbe“toppedoff”withCO2enrichmentona
loweroutputsetting,allowingforairconditionersanddehumidifierstobetterdeal
withtheheatandmoistureloadsassociatedwithCo2enrichmentandmaintaining
moresteadytemperatureandrHlevels.
1. FollowtheInitialInstallationInstructionsforyourICGseriesgenerator,andyour
S.I.C.E.SeriesCo2controller.
2. PlugtheICG-30powersupplyintoanelectricaloutletthatwillalwaysbe
energized.DONOTplugthepowersupplyfortheICG-30intotheCO2controller.
3. TurnthepowerswitchfortheICG-30totheONposition.
4. PresstheMODEbutton(S/M)until“S”showsontheICG-30LEDsystem
status screen.
5. TurnthepowerswitchtotheOFFposition.
6. ConnecttheappropriateSentinelS.I.C.E.shieldedcommunicationcablebetween
theICG-30andtheSentinelS.I.C.E.CO2controller.
S.I.C.E.shieldedcommunicationscablesareavailablefromyourpreferredretailer,
or from www.growgps.com/store.SentinelS.I.C.Eshieldedcommunications
cablesareavailablein5meter(part#SICEcbl5),10meter(part#SICEcbl10),
25meter(part#SICEcbl25),and50meter(part#SICEcbl50)lengths.
TheseareNOTstandardEthernetcables.Theyareshieldedtoreduceinterference
comingfromdigitalballasts,andarespeciallycoatedtonotallowmoistureinside.
TheuseofstandardEthernetcablesinNOTrecommended,andanyharmthat
comesfromtheuseofnon-SentinelapprovedcablesVOIDS any and all warranties.
Thespecialcoatingsonthesecablesmakesthemless-flexiblethan
standardEthernetcables.Theyarenotintendedtobehighlyflexible.
Itisrecommendedafterinstallationthatthecablesareaffixedsecurely
to the walls or ceilings of your greenhouse or grow room in a manner
that makes sure the cables are not pinched or crushed.
7. SettheSentinelS.I.C.EseriesCO2controllertothepreferredlevelsusing
the“SentinelIntelligence”settingasoutlinedintheusermanualoftheS.I.C.E.
series controller.
8. TurnthepowerswitchtotheONposition.
9. EnjoythemostadvancedCO2enrichmentoperationavailable!
B. Operation in the manual setting enrichment mode
WhiletheICG-30seriesCO2generatorshavebeendesignedwithadvanced
communication and control componentry for ideal operation using the proprietary
S.I.C.E.system,theICG-30canworkwithanypreviousSentinelbrandCO2
controllersaswellasothermanufacturerofferings.Andthebestpartisyoucan
alwaysupgradetoaSentinelS.I.C.E.seriescontrollerinthefuture!
1. FollowtheInitialInstallationInstructionsforyourICGseriesgeneratorandthe
appropriateinstructionsforyourexistingCO2controller.
2. PlugtheICG-30powersupplyintotheappropriateCO2controllerreceptacle.
3. TurnthepowerswitchfortheICG-30totheONposition.
4. PresstheMODEbutton(S/M)until“M”showsontheICG-30LEDdisplayscreen.
5. Presstheoutputbuttons(#or $)toselectbetweenoutputsetting#1,#2,or#3
asshownontheICG-30LEDsystemstatusscreen.
Asaverybasicstartingpoint,growingenvironmentsunder3,0003feet should be
settooutputlevel1,growingenvironmentsfrom3,0003to7,5003feet should be
settooutputlevel#2,andfrom7,5003feet and larger set to output level 3.
Ifitistakingtoolongtoreachyourdesiredsetpoint,considerusing
thenexthighersetting.Ifyouareconsistentlyover-shootingyour
desiredsetpoint,considerusingthenextlowersetting.
Remember,themostprecisecontrolavailableisobtainedusingaSentinel
S.I.C.E.seriesCO2controllerinconjunctionwiththeICG-30seriesgenerator.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS (continued)

©2015SentinelGlobalProductSolutionsInc.Allrightsreserved.
DistributedbySentinelGlobalProductSolutionsInc.,SantaRosa,CA95403
SentinelGPSInc.isdedicatedtoproducingenvironmentally
sustainableproducts.Theenclosedproductcomplieswith
RoHSDirective(2002/95/EC)that restrictsthe use of 6
hazardoussubstancessuchasmercury,cadmiumandlead.
Table of contents
Other Sentinel Portable Generator manuals
Popular Portable Generator manuals by other brands

Parker Balston
Parker Balston H2PEMPD-510 Installation, operation and maintenance manual

GOAL ZERO
GOAL ZERO Yeti 400 Lithium user guide

RVMP
RVMP Flex Power RVMP-OEM-4L1-RV401 installation manual

Firman
Firman H07552 owner's manual

Pecron
Pecron E1000 user manual

Shindaiwa
Shindaiwa DG1000MI Owner's and operator's manual