Senville SENAP-W36US User manual

Instruction Manual
Model# SENAP-W36US
PLEASE READ AND SAVE THESE INSTRUCTIONS
Air Purifier
For any inquiries, please give us a call at our toll-free number below
1-800-242-4935

Statement
READ AND SAVE THESE INSTRUCTIONS
This product meets the relevant requirements of AHAM, ETL and Energy Star.
With the technological innovation and improvement of the product, the product
manual contents of the same model as this product may be changed, and the
updated part will not further notify.
All the illustrations shown in this manual are based on the appearance of the
standard model purifier. They are for illustrative purposes only. The actual
appearance of the purifier is subject to the purchased product.
Due to product improvement, some of the parameters may be changed. The
changed parameters have no retroactive effect on this product. Please refer to
the product nameplate parameters.
If there is any change in the content of this manual, our company will make
announcement through the official website of the company without further
notice one by one, and unless otherwise stated in the notice of announcement,
the content of the change shall not be retroactive to this product in principle.
The right to explain the relevant provisions of this manual belongs to
Guangdong Midea Environmental Electrical Manufacturing Co., Ltd.
1

Important safety instructions
Maintenance
Use Restrictions
USE
- Must be repaired by professionals- When moving, cleaning
or disassembling the purifier, it must be stopped and
disconnected from the power supply
- It is forbidden to replace the power cord without
authorization. If the power cord is damaged, it must be
replaced by a professional of its manufacturer, maintenance
department or similar department in order to avoid danger.
- Filter needs to be replaced regularly. To change the Filter,
please contact the qualified service provider authorized by
our local company.
- Do not operate with wet hands
- Do not press hard on the top control panel of the machine
- Do not place items on the top of the machine
- Do not insert foreign objects into the air inlet and outlet
- Prohibit the storage of flammable and explosive gases at the
place where the purifier is used.
- Avoid long-term direct sunlight.
- It is forbidden to use in places such as bathrooms where
moisture is heavy and water is easy to pour.
- Do not place this machine on a slope or other uneven places.
- Do not use this machine in a oil-smoke environment, such as
kitchens.
- Do not use this machine outdoors
2

Important safety instructions
Warning:
- This appliance has a polarized plug (one blade is wider than
the other).
To reduce the risk of electric shock, this plug is intended to fit
in a polarized outlet only one way. If the plug does not fit fully
in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician. Do not attempt to defeat this safety
feature.
To Reduce The Risk Of Fire Or Electric Shock, Do Not Use
This Fan With Any Solid-State Speed Control Device.
- Skin or eye damage may result from directly viewing the light
produ-ced by the lamp in this apparatus. Always disconnect
power before relamping or servicing.Never replace the UV
lamp without authorized technician!
3

Lifting handle
Back cover
Status Display and
Control Panel
Lifting handle
Air outlet
Power cord
Control Panel
Activated carbon
Filter HEPA Filter
Product Introduction
4

1Remove the back cover
Grasp the position of wedging block
and pull outwards to remove the
back cover
Hold the drawstring at both
of Filter assembly and
remove the Filter assembly.
Disassemble the
packaging bag of the
Filter.
Install the Filter assembly.
The activated carbon Filter
is on the outside
2Install the Filter
Please make sure that the front side of filter elements installed correctly.
1
3
2
Installation
5

On/off button
Press this button to start.
Press again, it will shutdown
Purification volume button
Press this button to adjust the
volume of purification, with high,
medium and low grades
The status of the purification
volume can be intuitively indicated
by three indicators: LOW, MED,
and HIGH.
This product will default to the
last working gear each time you
turn on the machine.
Control and Status Display Panel
Installation
3Install the back cover
Simultaneously slide the two left
and right buckles at the bottom of
the back cover into the machine
body with both hands
Press the top with both hands
simultaneously and insert the
top two buckles into the
machine body. At this time, the
installation is in place.
Usage
6

Correct placement
more than 30cm
more than 30cm
more than 50cm
UV button
Press this button to turn on the
UV lamp when the switch is on,
then press to off.
This product uses a certain algorithm to
calculate the life of the Filter with the
opening time accumulated as a
reference value.
When the filter life is reached, the UV
indicator will flash, at this time to remind
the user to replace the filter;
After the filter replacement is completed,
long press the UV button for 3 seconds
to reset the filter status; after reset, the
UV indicator will no longer flash.
Usage
In order to achieve better cleaning effect and avoid the influence of metal shielding effect on
communication, please ensure that the air purifier is more than 30cm away from the wall and other
obstructions when using it, and maintain a distance of more than 50cm from the metal/appliance.
7

Filter cleaning/replacement
When the UV light on the display panel flashes,
it prompts you to replace the filter
Please select a filter that matches the model of the
machine for replacement. Please purchase from your
local authorized dealer.
For more details on the installation of the filter,
please see the “installation” section.
Press the UV button for 3 seconds,
the filter resets and restarts the timer
Cleaning
Maintenance
WARNING: RISK OF ELECTRIC SHOCKThese servicing instructions are for use by qualified
personnel only. To reduce the risk of electric shock, do not perform any servicing other than that
contained in the operating instructions unless you are qualified to do so!
- It is recommended to clean the filter twice a week and replace the filter half a year (adjust the cleaning and
replacement cycle according to the use environ-ment);
- Can not wash the filter;
- Smaller soft brushes or household vacuum cleaners are recommended for filter cleaning.
- When using the brush to clean, it should be brushed horizontally along the filter to avoid vertical brush, so as not to
damage the filter;
- When cleaning with a vacuum cleaner, keep the suction outlet 5-1Omm away from the surface of the filter so as
not to damage the filter.
- When used under the strong odor produced by cigarettes, barbecues, etc., the filter may have an odor in a matter
of weeks or months. Please clean and dry filter (2-5 days). If you still cannot eliminate the odor, replace the filter.
8

Model
High-grade CADRparticles (CFM)
Rated voltage (V-)
Rated frequency (Hz)
Rated power (W)
Noise [dB(A)]
SENAP-W36US
125
120
60
58
32-52
Technical Parameters
1. The performance parameters in the table are measured before delivery and are for reference only.
2. Due to product improvement, the following parameters may be changed and shall refer to the
product nameplate parameters.
3. The applicable area is according to the theoretical value calculated by (0.07 ~ 0.12) x CADR
particulate matter; with the use of different environments or outdoor pollution and other factors,
the applicable area will also change.
4. Purifying principle: The air purifier blows air into the machine and filters the air through the built-in
filter core. It can mainly play the role of filtering dust (such as PM2.5), formaldehyde, odor,
sterilization and others.
9

Before you ask for maintenance, please check according to the table below.
Please send it to repair in case of the following:
1. If the operation is abnormal or the machine does not operate, and the above
method is invalid;
2. Substances or water from the outside have entered and abnormal operation
has occurred.
Problems
encountered Reasons Solutions
Fault self-detection
Purifier cannot run - It is possible that the power cord is not
plugged or poor contact with power
cord
- May not turn on the power switch
- It is possible that the filter is not
installed in place and safety switch is
not triggered
- Please connect power and
make good contact
- Please turn on the power
switch
- Please properly install the
filter and buckle the back
cover
The effect is bad to
eliminate smoke and
odor
- It is possible that the filter assembly is
not installed well
- It is possible that the filter assembly
has reached the end of life
- It is possible that the air inlet is blocked
by foreign matter
- Please properly install the
filter assembly
- Please replace the new
filter assembly
- Please remove foreign
matter from the air inlet
Filter cleaning light
does not extinguish
- It may be that the "UV" button is not
long pressed for 3 seconds after the
filter assembly is replaced.
- After cleaning the filter
assembly, long press the
"UV" button for 3 seconds
It is hard to eliminate
the odor and smoke
- It may be that the filter assembly is also
wrapped in a packaging bag
- Please remove the
packaging bag outside the
filter assembly
10

11

12