
MANUAL Model:C3E
Thankyouverymuchforselectingproducts,PleasereadandunderstandthisMANUAL
beforeusingthisunit.
SESTOS
DIN(48X48mm)Digitalcounter
Range1-999999withUP/DOWNmode,Max.10kpcs
Presetscalerange:0.001-99.999presetscalecountfunction
MCUfordigitalcontrol,Highaccuracyandreliability
EEPROMstoredatafor10years
NPNandPNPinputswitchable
9.2mmheightLED,preventdazzle,highlyvisibledisplay
Tactswitchforupordownsetvalue,easilyoperate
Keylockfunction,preventmistakeoperation
Switchingpowersupplyandlowconsumption
,
Presetscalerange:
Powerandinput:
Voltage(Ordering):
Character:
Contactoutput:
SSRoutput:
Lifeexpectancy:
Max.countingspeed:
Databackup:
Controlsignals:
Control/Inputtype:
Inputlevel:
Externalpower:
Starttiming:
Resetmethod:
Cutoutsize:
MountingMethod:
Weight:
Ambienttemperature:
(C3E-R)
(C3E-V)
10kpcs(Rate1:1),100Hz,5KHz,10KHz
0.001-99.999
Thepowersupplyandinputcircuitareisolated.
AC100-240V10%50/60Hz5VA
AC/DC12-24V10%4VA
PV:6digital9.2mmheight,highlightredLED
SV:6digital7.0mmheight,highlightgreenLED
AC250V3A(Resistiveload)NO/NC
DC12V(Max.40mA)
Mechanical:10,000,000operationsmin.
Electrical:100,000operationsmin.
10years,Datacanbestoreornotbysetting
5ms(Reset,Gate)
Contact/No-voltageinput(NPN)/Voltageinput(PNP)
High(logic)4.5to30VDC
Low(logic)0to2.0VDC
DC12V/50mA(Max.)forsensoruseonly.
100ms
Poweron/External/Manual
45X45mm
Flushmountingandscrewterminals
Approx.120g
Operating:-1055(withnoicingorcondensation)
Storage:-2565(withnoicingorcondensation)
3585%RH
±≤
±≤
≥
≥
~℃
~℃
~
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
SESTOSTM
MD
RST
MD
RST
MD
MD
MD
MD
D.P.position
MD
MD
MD
SESTOSTM
MD
RST
COUNTER C3E
UP
1
2
34
56
MD
RST
12
34
123456
Group1keysettingdigital
:
Group2keysettingdigital
:
Group3keysettingdigital
:
Group4keysettingdigital
:
10KHz5KHz 100HzMax.counterspeed
()
DP0DP1DP2DP3
()()()()
Thisproductmustbemountedonthepanel,avoidelectricshock.
!
!
Whenthepoweristurnedon,isnotconnectingtheterminal,avoidelectricshock.
Ensuretheproductwithinthespecification.
Neverdisassemble,repairormodifytheproduct,ifneededpleasecontactagentorus
Donotusetheproductinlocationssubjecttogases,dust,vibration,corrosivedirectsunlight,
waterandoil,strongEMI
●
●
●
Ambienthumidity:
:OutputUP
:Mode
:Reset
:Up
:Down
:PresentValue
:SetValue
Indicator:
:Light--Reset;Blink--Pause
:KeyLock
PowerOn
PV
SV
Press
keyover3s Press
keyover3s
MD MD
*
*
*︽︾
1.Changetherunmodetosettingmodetheoperationiscontinuous.
2.Returntotherunmodeandautomaticresetwhenchangethe
functionsetting.
3.Whenfunctionmode,four""and""keyaresamefunction.
Ifnochangethesettingreturntotherunmodeafter60second,and
thesettingissavedsametimeautomaticreset.
InputMode UPUPMode
:
DOWNDownMode
:
Counter
speed
Outputtime
(second) 1.Whenoutputtimesetto,displayandself-holdingoutputuntil
resetsignal.
2.Whenoutputtimesetto--s;Automaticallyresetaftertimeisup.
Presetscale
Range:0.001-99.999(decimalpointpositionisfixed)
Inputselect NPN:No-voltageinput
PNP:Voltageinput
Fig1
ON:SavethePVandstatewhenPoweroff
OFF:NotsavethePVandstatewhenpoweroff
OFF:Unlock
ON:LockRSTkey(Seefig1)
、︽︾
SavePV
andstate
KeyLock