10
After the power indicator light switching power
supply is not lit No power supply Check the fuses on the network connection
LED is overheating The device has been overheated. Wait a few minutes until the LED goes out and
continue welding.
The fan is not working The fan was blocked folded cover Straighten fan cover
Unsatisfactory quality of the weld in MIG
Inadequate or poor quality materials or
consumables,
Replace consumables. Change the welding wire or the
gas cylinder for materials suitable or higher quality
Shielding gas flows from the wrong intensity. Check the gas hose, improve the connection hose with
fittings and quick status check Cylinder regulator, adjust
the inductance.
Inductance wrong setting.
Unsatisfactory quality of the weld MMA
electrode sticks to the work piece
Wrong polarity of welding cables Connect the correct welding wires
Humid electrode. replace electrode
Welder is supplied from the generator or by a long
extension cord diameter is too small cable Connect directly to the mains
Unsatisfactory quality of the weld TIG welding
Inadequate or poor quality materials or
consumables ,.
Replace consumables. Change the tungsten electrode
or the gas cylinder for higher quality materials
Improper flow of shielding gas Check that the shielding gas flows at the right
intensity
Incorrect shielding gas pressure
Check the regulator przybutlowy check gas hose,
improve the connection hose with quick connectors, and
status
10. OPERATING INSTRUCTIONS
Semi-automatic welding operation DUALMIG S3 210 and S4 210 DUALMIG should take place in an atmosphere free of corrosive components and
dusty. Do not place the device in dusty, near the working grinders, etc. Dust and pollution control boards metallic filings, wires and connections inside the
unit may cause an electrical short, and consequently damage to the welding machine.
Avoid use in environments with high humidity, especially in situations of occurrence of dew on the metal parts.
In the case of dew on the metal parts, eg. The device after the cold into a warm room, wait until it is completely dry and warm the device to room
temperature. Starting in these conditions, cold welding can cause damage. It is recommended that in the event of welding operation outdoor place it
under a roof to protect against adverse weather conditions. DUALMIG S3 device 210 should be operated under the following conditions:
-changes in the effective value of the supply voltage is not greater than 10%
- ambient temperature of from -10 ° C to + 40 ° C
- Atmospheric pressure 860 to 1060 hPa
- relative humidity of the atmosphere is not more than 80%
- height above sea level to 1000m
You kaz wear parts: You kaz wear parts:
lp For steel wire For aluminum wires
1 Contact tip M6x25 TW-15 Al end of the current TW-15 M6x25 2 Contact tip M6x25 TW-15 Al end of the current TW-15 M6x25 2
The connector current TW-15
3 Gas nozzle TW-15
4 The contribution of steel The contribution of Teflon
For a full list of consumables and spare parts is available on the website and in the company www.tecweld.pl TECWELD. There is a
possibility of direct purchase of these parts.