Shishido Electrostatic CABX350 User manual

AC 60Hz
AC 50Hz
HDC-AC 200Hz
AC 33Hz
8
7
6
5
4
3
2
1
0
0 500 1000 1500 2000 2500 3000 3500 4000
Running Time(h)
Decay TIme(sec)
C
o
m
i
t
t
m
e
n
t
(+)Decay Time
(-)Decay Time
Characteristic Decay Time(Running:4000 hours)
THREE COMMITMENT FROM SHISHIDO
Ordinary ones...
With SSD HDC-AC technology, the new ionizer does not require
cleaning over the long-time. HDC-AC ionizer have "Breaking-time" as
non discharging time. It makes less damage onto the discharge emitter.
C
o
m
m
i
t
m
e
n
t
Develop "AC" + "Shock-less" ionizer.
●Superior ion balance
●Long-term stability
●Shock-free
Long-term Stability in Ionizing
●Minimize the impact from the
dust on the emitter needle
●Minimize the impact from the
abrasions of emitter needle
Require constant cleaning and maintenance.
In general, the emitter needle requires cleaning every few weeks
to several months
The white crystals such as silica
(SiO2) and ammonium nitrate
(NH4NO3) adheres to the tip of the
emitter needle even being used in
the clean room (shown on the right).
Reluctant in maintenance could
cause contamination due to the fall
off of accumulated particles.
Long-term Maintenance-Free
●Prolong cleaning intervals for
the filter and emitter needle
Filter: After 3 months
Filter: New
Emitter Needle:
After cleaning
Magnified x 300
Emitter Needle:
After 3months
After 4000H
Quick Cleaning
Cleaned by IPA
Magnified photo on emitter needle
* Prolong cleaning intervals
* Substaintially decreased on the abrasions
of emitter needle
* Minimum ozone production
2
C
o
m
m
i
t
m
e
n
t
C
o
m
m
i
t
m
e
n
t
BREAKING TIME

PULSE TYPE
HDC-AC (200Hz)
Device: Compact and lightweight with Digital controlled. High power
the output of static elimination
Advanced ionizing capability by eliminating static electricity evenly
from high-speed moving objects
Long-term stability in performance
Require less maintanenace
(50/60Hz)
Device: Heavy and large due to winding transformer
High voltage of 4-7KV is required
Minor uncleanness and abrasion of emitter needle does not impact
the result of static elimination
Unclean emitter needle may cause the current to leak out and damage
the insulator
Speed of static elimination is slightly inferior to DC type
Use sine wave, less noise generated compares to pulse type device
(DC/AC)
Frequency (kHz)
Device: extremely compact and small due to HV power
Low voltage of 2KV is required
Damage to the insulator due to current leakage is small
Abrasion of emitter needle is minimum, replacement of emitter
needle may not be required depends on the material used
Ion generated near the emitter needle can be carried away by metal
pipes and vinyl tubes,etc.
Minimum change in the ion balance
AC TYPE
S t e a d y T y p e
Positive ion charged emitter needle and Negative ion charged emitter
needle generate large amount of ions which increase static elimination
speed. Requrie additioanl device to monitor the ion balance as the
abrasions of emitter needle may differ between Positive ion charged
emitter needle and Negative ion charged emitter needle
DC TYPE
(FewHz~30Hz)
Speedy in static elimination due to various frequncies
Big Electrical noise
Applied voltage 6-10KV
Unclean emitter needle may cause the current to leak out and
damage the insulator
High Voltage Static Eliminator Types and Characters
Method and Features
AC TYPE
(With ion adjustment)
Stable and well-balanced static
elimination by SSD unique
technology
AC TYPE
(Without ion adjustment)
Ion controller is required as the
Positive and Negative ions emitted
are not even
D C T Y P E
Uneven static elimination over the
entire area as ions ejected are
seperated by different emitter
needles
About Icons
Contents
● Characters and Details
Real ESD Solutions & New Technology
P2~3
●AC HV BUILT-IN IONIZER ELIMINOSTAT characters & details P4~5
HDC-AC Bar Type Ionizer P6~8
●STATIC ELIMINATOR BLOWERS WINSTAT HDC-AC Type HV BUILT-IN P9~14
High Frequency Type P15~17
DC Type P18~19
●HIGH FREQUENCY COMPACT SIZE TRANSFORMER BUILT-IN
AC TYPE SMALL SIZE IONIZER Nozzle Type P20~23
PIEZONIZER Gun Type P24~25
Pencil Type P25
●STATIC ELIMINATOR TESTER STATIRON Static Electricity Meter P26
In-Line Static Electricity Meter P26
●DECAY TESTER Handy Type CPM P27
Charged Plate Moniter P27
STATIC HONESTMETER Half Decay Tester P28
Honest Data Analyzing System P28
●RESISTANCE METER Digital Resistance Meter P29
SHOETESTERII Antistatic Shoe Leakage Tester P30
●AC POWER SUPPLY IONIZER ELIMINOSTAT High Voltage P31~32
Bar Electrode P33
Air Electrode P34
●DC POWER SUPPLY IONIZER ELIMINOSTAT Intergrated Power Supply Ionizer P35
●EXPLOSION-PROOF IONIZER Explosion-Proof Ionizer System P35
●HEAT-RESISTANCE IONIZER
ELIMINOSTAT P36
●LIGHT IRRADIATION IONIZER IRISYS Soft X-ray irradiation Ionizer P36
●DC HV GENERATOR STATILLER P37
●DUST HALER DUST HALER P38~39
●ANTI-STATIC SPRAY STATINOL P39
3
ChargeSNS
ChargeSNS
Removable
Balancer
fixfixfixfixfixfixfix
Replaceable
Buzzer Alarm
Buzzer rings when ion alarm or fan alarm is activated
HV Alarm
LED signals when HV transformer is abnormal
HV Alarm Output
LED/ OUTPUT signals when HV transformer is abnormal
Fan Alarm
LED displays when abnormal fan activity happens
Fan Alarm Output
LED/OUTPUT signals when FAN is abnoraml
Safety Louver
Operation stops when removing louver as easy
Maintenance
Serial Connection
Multiple serial connection available inside the
device
Tungsten Emitter Needle
SSD's Original Long life Emitter Needle
Emitter Needle Automatic Cleaning
Automatic emitter needle cleaning (24H/Time)
Ion Balance Monitor
Shows Ion Balance
DC corona discharge system
The ionizer uses a DC corona discharge system
Built-in Ion Balancer
Built-in tuned ion balancer
Air Speed Adjustment
Controllable Air speed
Over Current
LED signals when there is a over current for Safety
control
Cleaning Check
Signals when emitter needle is dirty or low ion
generation
HDC-AC
SSD unique techonology
Hybrid Digitally controlled AC
Abnormal Discharge Alarm
LED signals when emitter needle is discharging
abnormally
Over Current Alarm (Value Setting)
Prevent over current with self value-setting
Over Current Alarm (FIXED)
Prevent over current with a fixed value
Over Current Alarm (3 steps)
Prevent over current with 3 stages of setting
Charged Object Sensor
Detect any approach of charged objects
Emitter Needle Missing Sensor
Remind any missing emitter needle during
replacement
Emitter Needle Replaceable
Emitter needle set and needle can be replaced by
customer
MEG102

Long-term stability in static elimination
― SSD developed a unique and unparalledled standard for ionizer ―
Hybrid Digital Controlled AC
4

Control by
moving
one polarity
Control by varing the
pulse input
200Hz Chage the shape of output to control the
primary side signal of transformer with PWM.
0 95 240 360 480 600 720 780 6756 10404 12756 19200
0
5
10
15
20
25
30
Ion Balance Voltage(V)/±Decay time(sec)
Running time (h)
Ⅰ.B+DEC -DEC
HDC-AC
HDC-AC Features
Digital Control AC
(Hybrid Digital Controlled AC)
②Easy to control the output of high voltage by the digital input
of transformer (PWM = pulse with modulation).
Unique ion balance
adjustment function
Amplitude modulation:
Controls the amount of ions generated
Position modulation:
Emitter needle absorbs excess ions
Decrease in emitter needle abrasions
Less dirt generation and maintain a
long-term stability by the pulse of
high-voltage power supply
HDC-AC ionizer enables excellent stability over a long period
of time in static elimiation.
Long-term stability in static capabilities
Running Data (HDC-AC Ionizer)
The unique AC-type high voltage power supply (patented)
developed by SSD is a compact and stable power supply unit.
The winding transformer can be digitally controlled to deliver the
following features.
① Generate high-voltage with minimum compact size
(10 times smaller in size and 15 times lighter in weight than old models)
Ultra low ozone
Same as background level
HDC-AC
Transformer
Old Model
Transformer
Sustainable Static Elimination
SSD ionizer can safely and steadily remove statics
from all electronic products.
During the transportation of LCD,
the statics can be eliminated
evenly across the entire panel.
Eliminate statics all over the entire
area when moving wafer to the
cassette.
When the wafer stage is
detached, a quick rise of statics
can be removed.
Eliminate static evenly when
moving LCD into cassette.
Maintain low voltage in
the IC tray.
A variety of nozzle options are
available, such as for wafer
mounting process, electronic
parts, static elimination and dust
removal for parts feeders and
parts inside containers.
static elimination inside a
small container
(dust removal)
Partial
static elimination
for parts feeder during
transportation
electronic parts static
elimination
wafer static
elimination
CABX initial CABX: after used for 4years
5

TIMER RESET
TIME SELECT
CLEANING
ALARM
RUN
POWER
❶
❷
❸
❹
❺
❻
❼
❽
❾
30% improved in both sta�c elimina�on �me and size
Small ow type discharge needle nozzle with low air
consump�on is also available
Pre-set cleaning schedule on �mer
Varia�on of the discharge needle
Safety features
()
~
Main Features
Bar type Ionizer
HDC-AC with build-in high-voltage power supply
Function
POWER :
RUN :
ALARM :
CLEANING : ・
TIMER RESET :
T・SELECT :
Indicator Panel
150mA
I
A
N
IR
PU
PR
T
ES
:2
S
4
U
V
RE
D
:0
C
.01-0.5MPa(CleanandDry
AirOnly)
0
9
8
7
6
5
4
3
2
1
Dimensional Diagrams

★Let us know the length of the elecrode pole, type of emitter
needle, and the product model when you place the order.
Such as:CABX□□□□□□
●Length 350~3100mm(250mm pitch)
●Nozzle Flow Hor L
●Emitter needle material W(Tungstane) or S(Silicon)
(Example) Length 1850㎜, High flow tungsten emitter needle,
CABX1850HW
Length 600㎜、Low flow silicon emitter needle,
CABX600LS
Length
Nozzle Type
3.0
2.5
2.0
1.5
1.0
0.5
0
3.0
2.5
2.0
1.5
1.0
0.5
0
100 300 500 700 1000 100 300 500 700 1000 1200
measured distance(mm)
Decay Time (sec)
CABX850 High Flow Nozzle
CABX850 Low Flow Nozzle
CABC (conventional product)
CABX850 High Flow Nozzle
CABX850 Low Flow Nozzle
Decay Time(sec)
measured distance(mm)
CABX850mm, Air Pressure:0.3MPa CABX850mm, Air Pressure:0.5MPa
350mm
600mm
850mm
1100mm
1350mm
1600mm
1850mm
2100mm
2350mm
2600mm
2850mm
3100mm
450g
650g
860g
1060g
1260g
1470g
1670g
1880g
2080g
2290g
2500g
2710g
WeightsLengths
CABX3100
CABX350
CABX3100
CABX2850
CABX2600
CABX2350
CABX2100
CABX1850
CABX1600
CABX1350
CABX1100
CABX850
CABX600
0 95 240 360 480 600 720 780 6756 10404 12756 19200
30
25
20
20
15
10
5
0
Ⅰ.B Voltage(V) / Decay Time S(sec)
Time (h)
Ⅰ.B+DEC -DEC
Features
Measured Distance (mm)
CABX high flow nozzle
CABX low flow nozzle
CABC (conventional product)
100
0.2
0.2
0.3
300
0.3
0.4
0.7
500
0.6
0.8
1.1
700
1.0
1.5
1.8
1000
1.7
2.4
2.7
Measure Distance(mm)
CABX high flow nozzle
CABX low flow nozzle
100
0.2
0.2
300
0.3
0.3
500
0.5
0.6
700
0.7
1.1
1000
1.3
1.8
1200
1.9
2.2
Running Data
Le ngt h
CABX
﹇
H
D
C
-
A
C
型
﹈
Blower type Ionizer [HDC-AC models]
For more information, please check our website. http://www.shishido-esd.co.jp/english/index.html 7

•
Emitter Needle Guard(attached parts)
Emitter Needle Nozzle
23.8
23.2
19.8
Connector
HV Connector
(34)
29
31
29
Mounting Bracket
Adjustable ElectrodeAngle
Main Body
HV Cable(1000mm)
One Touch Air Joint
Diameter Ø6
Mounting Hole
Emitter Needle
L + 25
20.5
4.2
6
L + 10
L
A55
ELIMINOSTAT CABS can be used in a narrow area as the
controller and HV power supply are seperated.
●Equipped with new features of
• emitter needle removal detection sensor (Needle Error)
• signals out when emitter needle is detached during the
exchange process.
• detection of charged object detection sensor
(Charge SNS)
●ION detection (Cleaning) notifies the decrease of static
elimination performance.
●Electrodes can be manufactured in 110mm. increments
and up to 1030mm in 40mm increments.
●More varieties avalable for products less than 1m.
●Optimized structure increased the static elimination
performance by 30% (vs CABX) for the short-distance
ionization.
Main Feature Model CABS-AW-y-z-****
y: CT-TR connection cable L 2:2m, 5:5m
z: Power・Signal cable L 2:2m, 5:5m
****: Length of Bar L 110 ~ 1030mm (40mm/pitch)
Electrode CABS-D BW -xxxx <*1>
System Controller CABS-CT1 -xxxx <*1>
HV Power Supply CABS-TR1
Ion Generation Corona Discharge
Input Voltage DC24V±5%
Electrical Specification
Electric Consumption
12VA
Output Voltage ± 8kV0-p
Air Tube Size Diameter φ 6 Air Tube
Maximum Air Pressure 0.5MPa
Supplied Air Clean Dry Air
Ion Balance Within ±30V
Decay Time Peformance Within 1.0sec
(Distance 300mm, Air Pressure 0.3MPa, Electrode Length 350mm)
<*1> Bar length included, and it is available for same length model controller.
Specifications
Senser Details
HV Error
minor electrical discharge or over current detected
Needle Error emitter nozzle or needle detached
Cleaning decrease of ion generation detected
ChargeSNS detection of charged object
Specifications
Dimension Diagram
By using glass emitter needle and silicon emitter needle to
operate in an environment where slight dust is not allowed.
●AC Adaptor : OCAB-DA2
(voltage AC100V ~ 240V)
●
Intermediate Bracket
: OCABX-SUSP-A
(
over 1100㎜as a standard spec)
●Power/Signal Cable : OCABX-ENC3M
(length:3m)
●
Emitter Needle Guard
: KA13232
●Low Flow Type Nozzle L Nozzle
Tungsten type : OCABX-NDL-LW01
Silicon type : OCABX-NDL-LS01
●High Flow Type Nozzle H Nozzle
Tungsten type : OCABX-NDL-HW01
Silicon type : OCABX-NDL-HS01
Optional Components
HDC-AC
Built-in high-voltage power supply CABX
Seperated high-voltage power supply CABS
Bar type Ionizer
Improvement in Air Consumption
Small flow type nozzle reduces the air consumption by 60% comparing
with other SSD products. It supports powerful and stable static
elimination. The nozzle is replaceable and easy to install and detach
from the device.
Detection on abnormal discharge and spark
The safety feature automatically shuts off the high
voltage input when a short-circuit and abnormal
high voltage discharge is detected from the
emitter needle.
Stable static elimination over the entire area
Our product can supply large amount of positve
and negative ions evenly throughtout the static
elimination area, it is most suitable to use for
electronic devices that needs delicate static
elimination.
<image>
<image>
Emitter Nozzle Guard
Bar type ionizer ELIMINOSTAT CABX
Bar type Ionizer ELIMINOSTAT CABS
Controller (CABS-CT1)
HV Power Supply (CABS-TR1)
check our website
for details
system configuration
controller dimension diagram
ionizing area
Image of replacing emitter needle
8
ChargeSNS
ChargeSNS
Replaceable
This manual suits for next models
11