18
3.6 Checking of state parameter
Press and button at the same time to enter the state parameter interface. Then, press
or button to check the state parameters.
4. Parameter Setting
These settings are for Engineers only, please call if you require to change any of the system parameters.
Press and button at the same time to enter the system parameter setting interface.. Press
or to view P1-P19 parameter. Press button again to set value you need. Parameter setting
as below:
Meaning
DC inverter compressor frequence
Current
Water inlet temperature
Water tank temperature
Water outlet temperature
Reserver
Display
d01
d02
d03
d04
d05
d06
Meaning
Discharge temperature
Outdoor a temperature
Coil temperature
Suction temperature
Cooling coil temperature
Electronic expansion valves efficiency
mbient
Display
d07
d08
d09
d10
d11
d12
Number
Means Range
Default
20℃~55
℃
15℃~4
5℃
5℃~35℃
1℃~10℃
0/1
20℃~60℃
2~90min
1℃~10℃
55℃
0/1
0
60℃
30min
The water tank temperature setting of hot water tank mode
The indoor ambient temperature setting of heating mode
The indoor ambient temperature setting of cooling mode
Hot water tank mode, water tank temperature difference between the
unit stop heating and restart heating
The control mode of defrost
0:automatic 1:manual
The limit of heating mode set temperature
Heating mode, indoor ambient temperature difference between the unit stop
heating and restart heating
The auxiliary electric heater start delay time(the time to
delay after compressor turn on
The optional of auxiliary electric heater
0:heating mode electric heater 1:without electric heater 0/1
The setting temp. and real temp. difference began to keep constant temp. 0℃~6℃
0℃
Water tank electric heater stared temperature 30℃~55℃
50℃
The ambient temperature setting of ambient temperature too low protection -25℃~-1℃
-20℃
27℃
25℃
5℃
3℃
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
P15
P16
P17
P18
P19
P20
P21
P22
P23
P24
-20℃~10℃
5℃~45℃
25min~70min
-7℃
13℃
45min
The maximum time of defrost status
Enter the defrost status setting of coil temperature
Exit the defrost status setting of coil temperature
Heating defrost cycle setting
2min~20min
8min
-5℃~5℃
3℃~15℃
0℃
10℃
The compensation of hot water tank temperature
The difference setting of solar cycle pump start working
The compensation of indoor ambient and return air temperature
-5℃~5℃
0℃
Model selection(1:Hotwater 2:Heat 3:Hot water&Heat 4:Cool
5:Hot water&Cool 6:Heat&Cool 7:Multifunction 1~7
7
0-30
24-65
0℃
10℃
Heating mode (0: Heating normal 1:Heating curve )
Curve slope
Curve set
0/1
0
Model switch (0: not use Model switch 1:switch control model ) 0/1
0