manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Thermostat
  8. •
  9. Siemens RDE100 Series User manual

Siemens RDE100 Series User manual

Other manuals for RDE100 Series

4

This manual suits for next models

2

Other Siemens Thermostat manuals

Siemens RDS110 User manual

Siemens

Siemens RDS110 User manual

Siemens RDD100 Series User manual

Siemens

Siemens RDD100 Series User manual

Siemens RDS110.R User manual

Siemens

Siemens RDS110.R User manual

Siemens RDH100 User manual

Siemens

Siemens RDH100 User manual

Siemens TH 192 HC Owner's manual

Siemens

Siemens TH 192 HC Owner's manual

Siemens raa20 series User manual

Siemens

Siemens raa20 series User manual

Siemens Powers ET 134 Owner's manual

Siemens

Siemens Powers ET 134 Owner's manual

Siemens RDD810KN/NF User manual

Siemens

Siemens RDD810KN/NF User manual

Siemens QAW20 User manual

Siemens

Siemens QAW20 User manual

Siemens RDF510 Series User manual

Siemens

Siemens RDF510 Series User manual

Siemens RDE100 Series User manual

Siemens

Siemens RDE100 Series User manual

Siemens QAF64 Series Instruction manual

Siemens

Siemens QAF64 Series Instruction manual

Siemens QMX3.P37 User manual

Siemens

Siemens QMX3.P37 User manual

Siemens RCR10/868 User manual

Siemens

Siemens RCR10/868 User manual

Siemens RDG20 KN Series Operator's manual

Siemens

Siemens RDG20 KN Series Operator's manual

Siemens RDH100 User manual

Siemens

Siemens RDH100 User manual

Siemens RAA20 User manual

Siemens

Siemens RAA20 User manual

Siemens RDG User guide

Siemens

Siemens RDG User guide

Siemens RDD100.1RF User manual

Siemens

Siemens RDD100.1RF User manual

Siemens RDG100KN Operator's manual

Siemens

Siemens RDG100KN Operator's manual

Siemens RDE100.1RF User manual

Siemens

Siemens RDE100.1RF User manual

Siemens REV17 Series User manual

Siemens

Siemens REV17 Series User manual

Siemens RDB160BN Operator's manual

Siemens

Siemens RDB160BN Operator's manual

Siemens DF301 Operator's manual

Siemens

Siemens DF301 Operator's manual

Popular Thermostat manuals by other brands

Full Gauge TIC-17C product manual

Full Gauge

Full Gauge TIC-17C product manual

Imit Chronomix S manual

Imit

Imit Chronomix S manual

ChiliTec ST-35 ana instruction manual

ChiliTec

ChiliTec ST-35 ana instruction manual

Salus VS05 Installer's/user's manual

Salus

Salus VS05 Installer's/user's manual

Azel D-500 user guide

Azel

Azel D-500 user guide

Honeywell Chronotherm III owner's manual

Honeywell

Honeywell Chronotherm III owner's manual

Charmeg MP-R user manual

Charmeg

Charmeg MP-R user manual

dixell WING XW40LS Installing and operating instructions

dixell

dixell WING XW40LS Installing and operating instructions

Network Thermostat NetX X7C-WIFI Installation and programming manual

Network Thermostat

Network Thermostat NetX X7C-WIFI Installation and programming manual

Radio Thermostat CT80 Operation guide

Radio Thermostat

Radio Thermostat CT80 Operation guide

HAI Omnistat RC-120 installation manual

HAI

HAI Omnistat RC-120 installation manual

Lennox iComfort E30 Installation and setup guide

Lennox

Lennox iComfort E30 Installation and setup guide

Lux Products PSD011Ba Installation and operating instructions

Lux Products

Lux Products PSD011Ba Installation and operating instructions

Computherm Q20 operating instructions

Computherm

Computherm Q20 operating instructions

Heatmiser neoStat user manual

Heatmiser

Heatmiser neoStat user manual

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

Mars

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

LUX LP0511D user manual

LUX

LUX LP0511D user manual

Saswell SAS920XWHB-7-S-RF User manual and warranty card

Saswell

Saswell SAS920XWHB-7-S-RF User manual and warranty card

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

s
1422
Room thermostat with Auto
Timer, Option External Input
RDE100..
for heating systems
•Room temperature control
•2-position control with On/Off output for heating
•Comfort, Economy, Auto timer and Protection mode
•Auto time switch
•Adjustable commissioning and control parameters
•Mains-powered AC 230 V (RDE100) or battery-powered DC 3 V (RDE100.1)
•Multifunction input (RDE100.1 only) for external floor sensor, keycard
contact, etc.
Use
The RDE100.. is used to control the room temperature in heating systems.
Typical applications:
•Apartments
•Commercial spaces
•Schools
For the control of the following pieces of equipment:
•Thermal valves or zone valves
•Gas or oil boilers
•Fans
•Pumps
•Floor Heating
CB1N1422en
2016-03-10
Building Technologies
Functions
•Room temperature control via built-in sensor or external input
•Selection of operating mode with operating mode touchkey
•Setting auto time switch (individual day, 7 day or 5-2 day)
•Display of current room temperature or setpoint in °C or °F
•Touchkey lock (manually)
•Setpoint lock
•Periodic pump run
•Reloading factory settings for commissioning and control parameters
•One multifunctional input (RDE100.1 only) freely selectable for:
Floor Heating temperature limitation function
Operating mode switchover contact (keycard, window contact, etc.)
Temperature control
The RDE100.. acquires the room temperature with its built-in sensor and maintains
the setpoint by delivering control commands. The switching differential is 1 K.
Q14
T[°C]
ON
OFF W
SD
1422D01
T
Room temperature
SD
Switching differential
W
Room temperature setpoint
Q14
Output signal for heating
Floor heating limitation function (RDE100.1 only)
The factory setting for this function is Off (disabled) and must be set to "On" if floor
heating is used.
The external floor temperature sensor is connected to input X1, and acquires
the floor temperature. If the floor temperature exceeds the parameterized
temperature limit xx ºC (P14 = 1, P15 = 1, P16 = xx ºC), the heating valve is fully
closed until the floor temperature returns to a level below the parameterized limit.
Typical application is rooms (dry floor).
If the application does not require floor heating temperature limitation but instead
uses the external sensor as a source for both room temperature display and
control, the parameters will have to be set as follows: P14 = 1, P15 = 0. A typical
application is the bathroom (wet floor) where a constant floor temperature is
required.
It is not recommended to have only an internal built-in room sensor for floor
heating since there is a potential risk of overheating.
Operating mode switchover function
This function allows keycard application, please refer to the section “Operating
notes, Economy mode”.
2 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10
Periodic pump run function
Can only be used when circulating pump or valve is controlled!
This function protects the pump or valve against seizing during longer off periods.
Periodic pump run is activated for 3 minutes every 24 hours at 12:00.
Parameter
Pump status
P12 = 0 (Default)
Pump run off
P12 = 1
Pump run on
12:00 12:00
3 min. 24 h
on
off
142
2Z04
Type summary
Product No.
Stock No.
Features
RDE100
S55770-T278
Mains-powered AC 230 V
RDE100.1
S55770-T279
Battery-powered DC 3 V
Ordering
•When ordering, please indicate product No. / stock No. and description.
•Example:
Valve actuators/external sensor must be ordered separately.
Product No.
Stock No.
Description
RDE100
S55770-T278
Room thermostat
3 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10
Equipment combinations
Description
Product No.
Data Sheet
Electromotoric actuator
SFA21.. 4863
Electrothermal actuator (for
radiator valves)
STA23.. 4884
Electrothermal actuator (for
small valves 2.5 mm)
STP23.. 4884
Damper actuator
GDB.. 4634
Damper actuator
GSD.. 4603
Damper actuator
GQD.. 4604
Rotary damper actuator
GXD.. 4622
Cable temperature sensor
QAH11.1 1840
Room temperature sensor
QAA32 .. 1747
Mechanical design
The room thermostat consists 2 parts:
•Plastic housing which accommodates the electronics, the operating elements
and the room temperature sensor
•Mounting plate with screw terminals
The housing engages in the mounting plate and is secured with a screw.
Description Product No.
Mounting
Instruction
Adapter plate
(for China 86 conduit box,
BS4662 UK conduit box)
ARG70.5 A6V10563479
4 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10
1) Operating mode touch key
2) Set
3) Ok
4) Touch key for decreasing a value
5) Touch key for increasing a value
Operation and settings
5 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10
1
2
3
5
6
7
8 9 10 11 13
14
15
16
19
2021
22
17
412
18
#
Symbol
Description #
Symbol
Description
1
Indicating that batteries need to be
replaced
(only with battery-powered version
RDE100.1)
12
Display of time
2 Protection mode
(protection mode symbol can be
enabled via parameter settings) 13
Morning: 12-hour format
Afternoon: 12-hour format
3
Auto timer mode 14
Confirmation
4 View and set auto time switch 15
F
Room temperature in degrees Fahrenheit
5 Comfort mode 16
Touch key lock activated
6 Economy mode 17
C
Room temperature in degrees Celsius
7
Escape 18
Display of room temperature, set point,
etc.
8
External input enabled
(RDE100.1 only)
19
Heating On
9 Permanent set point setting 20
Weekday 1 = Monday 7 = Sunday
10 Day and time setting 21
Timer bar
11 Holiday mode setting 22
Current room temperature
Display
6 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10
Mounting and installation notes
Do not mount the thermostat in niches or bookshelves, not behind curtains, not
above or near heat sources, and not exposed to direct solar radiation. Mount about
1.5 m above the floor.
Mounting •Mount the thermostat in a clean and dry location without direct air flow from a
heating/cooling equipment, and not exposed to drip or splash water
Note: When RDE100.. is equipped with either China 86 conduit box or BS4662
UK conduit box, ARG70.5 adapter plate is suggested to provide a better fitting
installation.
Wiring See Mounting Instructions M1429 enclosed with the thermostat.
•Ensure that wiring, protection and earthing comply with local regulations
•Correctly size the cables to the thermostat and the valve actuators
•Use only valve actuators rated for AC 24…230 V
Warning!
No internal line protection for supply lines to external consumers.
Risk of fire and injury due to short-circuits!
•Adapt the line diameters as per local regulations to the rated value of the
installed overcurrent protection device
•The AC 230 V mains supply line must have a circuit breaker with a rated
current of no more than 10 A
•Disconnect from power supply before removing the unit from its mounting plate
•External Inputs X1, may carry mains potential. Sensor cables or window
contact must carefully install before powering up the thermostat
Commissioning notes
After power is applied, the thermostat carries out a reset during which all LCD
segments flash, indicating that the reset was made correctly. After the reset, the
thermostat is ready for commissioning by qualified HVAC personnel.
The control parameters of the thermostat can be set to ensure optimum
performance of the entire system. Please refer to Operating Instructions
CB1B1422, section "Do you want to change parameters?".
Commissioning
Sensor calibration
7 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10
If the temperature on the display does not agree with the room temperature
effectively measured, the temperature sensor can be recalibrated. For that
purpose, adjust parameter P04.
We recommend reviewing the setpoint lock (for public areas) in parameters P06
and P08 and changing them as needed.
Since the thermostat uses touch technology and to minimize battery power
consumption, a parameter P21 (adjustable from 0.25 to 1.5 seconds) is
implemented for the user to adjust. This function is only valid for the battery-
powered version and the default value is 1 second.
This means that when, for a certain time, the user does not touch the touchpad, the
unit operates in power saving mode and the touchpad is running at a scanning rate
of 1 second.
(From the calculation – assuming 4 operations per day on the thermostat, the
estimated 1-second scanning rate results in a battery life of 1 year. If the user
increases the scanning rate, the batteries’ life is extended.)
If the battery symbol appears, the batteries are almost exhausted and should
be replaced. Use alkaline batteries type AAA.
Operating notes
The RDE100.. provides Comfort, Economy, Auto timer and Protection mode. The
difference between Comfort and Economy mode is only the room temperature
setpoint. The changeover between Comfort, Economy and Protection mode is
made either automatically by the auto time switch or by pressing touchkey mode.
When Comfort mode is activated, symbol appears on the display. The setpoint
(20 ºC) can be readjusted by pressing touchkeys +and –.
When Economy mode is activated, symbol appears on the display. The setpoint
(16 ºC) can be readjusted by pressing touchkeys +and –.
In RDE100.1, a window contact feature is that a user can connect a window
contact to the input X1, . Depending on whether the window contact is
configured to Normally Open or Normally Close (Parameter P14 = 2, Parameter
P17 = 0 or 1), a change in this status will automatically switch the thermostat from
any modes to Economy mode. This feature is good for public area. The factory
setting for this function is Off (disabled).
If the temperature falls below 5 ºC, the unit automatically activates the heating
output. The symbol appears only, if the icon is enabled via parameter settings.
When Auto timer mode is enabled, the changeover between the operating modes
(Comfort and Economy mode) will take place automatically. There are three
options for time switch setting: individual day, 7 day or 5-2 day. You can select
Comfort or Economy mode in every 15 minutes interval of the day. The 0:00 to
24:00 hour time bar will allow you to set the mode throughout the selected day(s).
Default
value
Day/s
Comfort mode
Economy mode
Mo (1) – Fr (5) 6:00 – 8:00 hr
17:00 – 22:00 hr
22:00 – 6:00 hr
8:00 – 17:00 hr
Setpoint lock
Touchpad scanning
rate
Change of batteries
(only with battery-
powered version
RDE100.1)
Comfort mode
Economy mode
Protection mode
Time switch
8 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10
Sa (6) – Su (7)
7:00 – 22:00 hr
22:00 – 7:00 hr
Please refer to Operating Instructions CB1B1422, section "Do you want to enter
your own time switch?"
When holiday mode is activated, symbol appears on the display. The set point
(12 ºC) and the number of days a user is away can be readjusted by pressing
touch keys + and –.
Maintenance notes
The thermostats are maintenance-free.
Disposal
The devices are considered electronics devices for disposal in term of European
Directive 2012/19/EU and may not be disposed of as domestic waste.
•Dispose of the device via the channels provided for this purpose.
•Comply with all local and currently applicable laws and regulations.
•Dispose of empty batteries at designated collection points.
Holiday mode
9 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10
Technical data
Operating voltage
•
RDE100 at L - N
Frequency
Power consumption
AC 230 V +10/
-15%
50 Hz
4 VA
•RDE100.1
DC 3 V (2 x 1.5 V alkaline batteries AAA)
For battery life (RDE100.1), see below (alkaline batteries type AAA).
Battery life
calculation is based on the touchpad scanning rate during idle time
(assuming a user presses 4 touch keys per day):
Scanning rate 0.25 s
Scan
ning rate 0.50 s
Scan
ning rate 1.00 s
Scan
ning rate 1.50 s
194 days battery life
274
days battery life
3
46 days battery life
37
9 days battery life
Control
input Q11-Nx (Com)
•
Rating RDE100
•Rating RDE100.1
(AC
24…230 V) Max. 5(2) A Min. 8 mA
(AC 24...230 V) Max. 5(2) A Min. 8 mA
External sensor
‘
X1’ - ‘ ’ (Reference)
Or
Digital On/Off
‘X1’ - ‘ ’ (Reference)
NTC3K/QAH11
.1/QAA32
On/Off switch
Control output Q12-Nx (NC contact)
Rating RDE100
Rating RDE100.1
(AC 24...230 V) Max. 5(2) A Min.
8 mA
(AC 24...230 V) Max. 5(2) A Min. 8 mA
Control output Q14-Nx (NO contact)
Rating RDE100
Rating RDE100.1
(AC
24...230 V) Max. 5(2) A Min. 8 mA
(AC 24...230 V) Max. 5(2) A Min. 8 mA
No internal fuse.
External preliminary protection with max. C 10 A circuit breaker in the supply lines
required under all circumstances.
External protection for incoming cable
Circuit breaker
Circuit breaker tripping characteristic
Max. 10
A
Type B, C or D to EN 60898 and EN 60947
Switching differential SD
Comfort mode
Economy mode
Holiday mode
1 K
20 °C (5...35 °C)
16 °C (5...35 °C)
12 °C (5...35 °C) (Standalone)
Built
-in room temperature sensor
Setpoint setting range
Accuracy at 25 °C
Temperature calibration range
5…35 °C (
Comfort/Economy mode)
< ±0.5 K
±3.0 K
Resolution of settings and displays
Setpoints
Tempera
ture value displays
0.5 °C
0.5 °C
Operation
Climatic conditions
T
emperature
Humidity
As per
IEC 60721-3-3
Class
3K5
0…50 °C
<95% r.h.
Power supply
Control inputs
External sensor
(RDE100.1 only)
Control outputs
Function data
Environmental conditions
10 / 14
Siemens RDE100.. Room thermostat with Auto Timer, Option External Input CB1N1422en
Building Technologies 2016-03-10