SIGLENT SPD3000 Series User manual

User Manual
SPD3000 Series
Programmable DC Power Supply
SIGLENT TECHNOLOGIES CO., LTD
www.biall.com.pl

SIGLENT
SPD3000 User Manual I
Copyright information
1. SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved.
2. Information in this publication replaces all previous corresponding material.
3. SIGLENT reserves the right to change the specifications and price of the
product.
4. Any way of copying, extracting and translating the content of the manual is
not allowed without permission of SIGLENT.
Note:
SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., LTD.
www.biall.com.pl

SIGLENT
II SPD3000 User Manual
General Safety Summary
Please review the following safety precautions carefully to avoid personal
injury or damage to this product or any product connected to it. To prevent
potential danger, please use the instrument as specified.
Use proper power cord
Only the power cord designed for the instrument and authorized by local
country could be used.
Power supply
AC Input Voltages: 100V/110V/220V/230V ±10%, 50/60Hz.
Use proper fuse
The fuse types: 100V/110V: T6.3A/250V; 220V/230V: T3.15A/250V;
Make sure to use the correct type of fuse before turning on the instrument.
Do not connect the power cord before replacing the fuse.
Find out the reason why the fuse burned out before replacing the fuse.
Ground the instrument
The instrument is grounded through the protective terra conductor of the power
cord. To avoid electric shock, the grounding conductor must be connected to
the earth. Make sure that the instrument is properly grounded before any
inputs or outputs.
Observe all terminal ratings
To avoid fire or electric shock, please observe all ratings and symbols on the
instrument. Read this guide carefully to know more details about the ratings
before connection.
Keep proper ventilation
Inadequate ventilation may cause an increase of temperature,, which will lead
to further damage. Please keep proper ventilation and check the fan and
air-vents regularly when using the instrument.
Operate condition
Location: indoor, no strong light, almost no Interfering pollution;
Comparative humidity: <80%
Altitude: <2000m
Temperature: 0℃ to 40℃
www.biall.com.pl

SIGLENT
SPD3000 User Manual III
Do not operate in an explosive atmosphere
To avoid personal injury or damage to instrument, please do not operate in an
explosive atmosphere.
Keep surface of the product clean and dry
To avoid dust or moisture in the air influence the performance of the
instrument , please keep surface of the product clean and dry.
www.biall.com.pl

SIGLENT
IV SPD3000 User Manual
Safety Terms and Symbols
Terms may appear on the product:
DANGER: Indicates direct injury or hazard that may happen.
WARNING: Indicates potential injury or hazard that may happen.
CAUTION: Indicates potential damage to the instrument or other property that
may happen.
Symbols may appear on the product:
Hazardous Protective Warning Earth Power
Vlotage Earth Ground Ground Switch
www.biall.com.pl

SIGLENT
SPD3000 User Manual V
SPD3000 Series Brief Introduction
SPD3000 series Programmable DC Power Supply is convenient, flexible and
multi-function. It has three independent outputs, two sets of adjustable voltage
value and a fixed set of selectable voltage value of 2.5V, 3.3V, and 5V ,and it
also provides output short circuit and overload protection at the same time.
Main features of SPD3000 Series
4.3” TFT color LCD display with content of 16M;
Three independent outputs, two of which are adjustable, and the total power
up to 195W;
Four kinds of input voltage values includes 100V, 110V, 220V and 230V to
satisfy different requirements;
Function of storage and call setting parameters;
Function of timing output ;
Function of waveform display, Real-time display of voltage or current
waveforms with digital display of voltage, current and power values
Start up screen protective procedure every fixed interval(30 minutes)
Perfect PC software to realize the real-time control through USBTMC..
www.biall.com.pl

SIGLENT
VI SPD3000 User Manual
Content
General Safety Summary ....................................................................................................II
SPD3000 Series Brief Introduction..................................................................................... V
Chapter 1 Start Guide..........................................................................................................1
The front panel..........................................................................................................................2
The rear panel ...........................................................................................................................6
Notice in first use of SPD3000 Series .................................................................................7
Input power requirement ...........................................................................................................7
Electrical check.........................................................................................................................7
Output check .............................................................................................................................8
Chapter 2 Control panel operation ......................................................................................9
2.1 Output summary ............................................................................................................10
2.2 CH1/CH2 Independent Output.....................................................................................11
2.3 CH3 Independent mode................................................................................................12
2.4 CH1/CH2 Series mode .................................................................................................13
2.5 CH1/CH2 Parallel mode ...............................................................................................15
2.7 Timer................................................................................................................................17
2.9 Version information........................................................................................................20
2.10 Upgrade firmware........................................................................................................21
Chapter 3 Remote control .................................................................................................23
3.1 Command list..................................................................................................................23
3.2 Command description ...................................................................................................24
Chapter 4 Specification......................................................................................................30
Chapter 5 Troubleshooting ................................................................................................32
Chapter 6 Service and Support .........................................................................................33
Maintain summary................................................................................................................33
Contact SIGLENT.................................................................................................................33
Appendix A: Accessories ........................................................................................................34
www.biall.com.pl

SIGLENT
SPD3000 User Manual 1
Chapter 1 Start Guide
In this chapter, we mainly introduce the panel and Display Interface of
SPD3000, and also the notes about how to check and operate it at the first use.
You can quickly understand how to operate it after reading the following steps.
Please check the instrument according to the following steps.
1. The machine and packing inspection
If the packing or cushioning material is seriously damaged, please retained
them for follow-up inspection.
If the instrument is damaged during shipment, the compensation will be
provided by consigner or carrier, and SIGLENT will not undertake free repair
or replacement.
If there is a mechanical damage or loss please contact with your sales
representative.
2.Accessory examination
Information about the accessories is introduced in detail at the end of the
manual, you can refer to this description to check whether the accessories are
completed t.
If there are accessories damaged or lacked, please contact with your
SIGLENT sales representative.
www.biall.com.pl

SIGLENT
2 SPD3000 User Manual
The front panel
NO. Description NO. Description
1 Logo 9 CH3 DIP Switch
2 Display Area 10 Power Switch
3 Model 11 CH1 Output Terminal
4 System parameter
configuration button 12 Ground Terminal
5 Multi-function knob 13 CH2 Output Terminal
6 Fine Adjust button 14 CV/CC indicator light
7 Right/Left Direction button 15 CH3 Output Terminal
8 Channel Control button
○
6
○
7
○
8
○
9
○
10 ○
11 ○
12 ○
13 ○
14 ○
15
○
1 ○
2 ○
3 ○
4 ○
5
www.biall.com.pl

SIGLENT
SPD3000 User Manual 3
Instruction for buttons
Buttons for setting parameters
: Press the button to turn on/off the waveform display interface;
: Press the button to set series mode of CH1/CH2, and the logo
“ ” displays at the same time;
:Press the butten to set parallel mode of CH1/CH2, and the logo
“ ” displays at the same time;
:Press the butten to enter the storage function interface
:Press the butten to enter timer setting interface
: Press the button longer to lock it and shorter to turn to system
information interface.
Buttons for controlling the channel
: Press the button to turn on/off all the channels;
: Press the button to select CH1 as the current channel;
: Press the button to select CH2 as the current channel;
: Press the button to turn on/off the CH1 output;
: Press the button to turn on/off the CH3 output.
Other buttons
: Press the button to open the fine tuning function and change the
parameters with the minimum step;
: To move the cursor around.
WAVEDISP
SER
PARA
LOCK/VER
TIMER
RECALL/SAVE
CH3 ON/OFF
CH2
CH1
ALL ON/OFF
ON/OFF
FINE
www.biall.com.pl

SIGLENT
4 SPD3000 User Manual
The output terminal on front panel
The output terminals of CH1、CH2 and CH3 include positive terminal and
negative terminal, and a common ground for CH1 and CH2 additional. Each
channel has its own logo. The operation details are introduced in the
follow-up ” control panel operation”.
www.biall.com.pl

SIGLENT
SPD3000 User Manual 5
User interface
○
1 Parallel/Series logo: The logo will be displayed when the corresponding
mode is on
○
2 Channel logo;
○
3 Operating mode logo: The corresponding logo will display when working in
CV or CC mode;
○
4 LOCK logo: It will display when the LOCK is turned on
○
5 USB logo: It will display when there is a USB connection;
○
6 Voltage value;
○
7 Current value;
○
8 Power value;
○
9 Timer lD: Timer state identification
○
10 Channel on/off logo;
○
10
○
6
○
7
○
8
○
1 ○
2 ○
3 ○
4 ○
5
○
9
www.biall.com.pl

SIGLENT
6 SPD3000 User Manual
The rear panel
Description:
○
1 warning message
○
2 The DIP switch of the AC power and its identification .
○
3 The description of the AC input voltage
○
4 AC power socket
○
5 The fan air vents
○
6 CE certification mark
○
7 USB interface and identification
○
1 ○
2
○
6 ○
5 ○
4 ○
3
○
7
www.biall.com.pl

SIGLENT
SPD3000 User Manual 7
Notice in first use of SPD3000 Series
To ensure that the instrument can work normally,, you need to undertake the
necessary inspection before using the SPD3000.
Input power requirement
The SPD3000 series allows two kinds of frequency that are 50hz and 60hz,
four kinds of AC power that are 100v、110v、220v and 230v. You can choose
the different input power with the “DIP switch ”at the rear panel according to
your actual requirement.
Warning
Pease disconnect the power cords at first and then dial the code to
the corresponding gear if you want to change a new power supply.
Electrical check
Please use power cord provided as accessories and connect the instrument to
AC power first, and then starting power check according to the following steps.
1. Connect the power supply
Warning
To avoid electrical shock, please make sure that the instrument has
been properly earthing.
2. Turn on the power switch
Press the button “POWER” to enter boot interface, and the default setup
will show automatically after a while.
www.biall.com.pl

SIGLENT
8 SPD3000 User Manual
Output check
The output check includes voltage check in condition of all channels with no
load and current check in condition of short circuit so as to make sure that the
instrument correctly responds to operation of the front panel.
1. Voltage output check
(1) Within no load, turn on the power, and make sure the setting current values
of all channels are not zero;
(2) Check the voltage output of CH1/CH2
Turn on CH1/CH2 and the instrument work in CV mode. Check whether the
voltage value could be changed from 0V to 32V.
2. Current output check
(1) Turn on the power.
(2) Check the current output of CH1/CH2
Use an insulated wire to connect the positive and negative terminal of
CH1/CH2;
Turn off CH1 and CH2;
Revolve the knob to set the voltage value to 32V;
Revolve the knob to set the current value to 0A;
Adjust the current parameters to check whether the current value can be
changed from 0A to 3.2A.
www.biall.com.pl

SIGLENT
SPD3000 User Manual 9
Chapter 2 Control panel operation
In this chapter,the function and operation of SPD3000 series control panel will
be introduced in detail to giving you an all-around understanding of it, which
will eventually lead to easier work.
Brief introduction:
Output summary
CH1/CH2 independent output
CH3 independent output
Parallel output
Series output
Waveform display
Timer
Save and recall
www.biall.com.pl

SIGLENT
10 SPD3000 User Manual
2.1 Output summary
Summary
SPD3000 series have three independent outputs, two of which are adjustable
in voltage value and the other one includes selectable 2.5V, 3.3V or 5.0V
Independent/Parallel/Series
SPD3000 series have three output modes: independent、parallel and series,
which can be selected through the track switch on the front panel. In the
independent mode, the output current and voltage are controlled respectively.
In the parallel mode, the current value is twice that of the single channel. In
the series mode, the voltage value is twice that of the single channel.
Constant voltage/current
In the constant current mode (independent or tracking mode), the current value
is rated and controlled through the front panel. The indicator light displays red
and the voltage value is under rating. It will return to constant voltage mode
when the current value is under dating.
In the constant voltage mode, the current value is less than the setting value,
and the voltage value is controlled through the front panel. The indicator light
displays green and the current value is maintained at the set value. It will
return to constant current mode when the voltage value is under dating.
www.biall.com.pl

SIGLENT
SPD3000 User Manual 11
2.2 CH1/CH2 Independent Output
Instruction CH1 and CH2 are working in the independent mode, at the same
time,they are insulated from the ground.
Output rating 0~30V/0~3A (max:32V, 3.2A)
Operation steps
1. Make sure that parallel/series mode is off.
2. Connect load to the positive and negative terminals of CH1/CH2.
3. Set voltage and current value of CH1/CH2: Firstly, move the cursor to
select the wanted parameter(voltage,current), and then revolve the
multi-function knob to change the corresponding parameter(you can press
“FINE” to make accurate adjusting).
Coarse adjusting: 0.1V or 0.1A each step.
Fine adjusting: the least precision each step.
4. Open output :Press “ON/OFF” button to turn on the output, the
corresponding indicator light gets lighted immediately and “CC” or “CV” is
showed on the current interface.
www.biall.com.pl

SIGLENT
12 SPD3000 User Manual
2.3 CH3 Independent mode
Instruction
CH3 is independent from CH1 and CH2, and it works neither in parallel mode
nor in series mode. Its voltage and current ratings are respectively 2.5V,3.3V,
5V and 3A.
Output ratings 2.5V/3.3V/5V, 3A
Operation steps:
1. Connect the load to the positive and negative terminals of CH3 on the front
panel.
2. Select the wanted voltage value by moving CH3 “DIP switch”.
3. Open output :Press “ON/OFF” button to turn on the output, the
corresponding indicator light gets lighted immediately.
CV CC
When the current value is higher than 3A, the overload indicator light turns red
and the working mode turns to CC from CV
Note: “overload” does not mean abnormal operation.
www.biall.com.pl

SIGLENT
SPD3000 User Manual 13
2.4 CH1/CH2 Series mode
Instruction
In the series mode, CH1 and CH2 are linked internally into one channel which
is controlled by CH1, and the output voltage value is twice compared with that
of single channel.
Output rating 0~60V/0~3A (max: 64V,3.2A)
Operation steps:
1. Press the “SER” button to start the Series mode, and the indicator light
turns bright immediately;
2. Connect the load to the positive terminal of CH2 and the negative terminal
of CH1;
3. Turn on CH2, and then adjust its current value by revolving the
multi-function button to 3A. In the default setup, the instrument works in
“Coarse”, you can turn to “Fine” by pressing “FINE” button;
Coarse: 0.1V or 0.1A each step;
Fine: the least precision each step;
4. Turn on CH1, and then set the output voltage/current value by revolving the
multi-function knob;
5. Press “ON/OFF” button to open the output.
Note: You can identify the current working state “CC” or ”CV” by referring to
indicator light of CH1/CH2.(red means CV, green means CC).
www.biall.com.pl
Table of contents
Other SIGLENT Power Supply manuals

SIGLENT
SIGLENT SPS5000X Series User manual

SIGLENT
SIGLENT SPD1305X User manual

SIGLENT
SIGLENT SPD3303C Series User manual

SIGLENT
SIGLENT SPD1168X User manual

SIGLENT
SIGLENT SPS5000X Series User manual

SIGLENT
SIGLENT SPD3303X User manual

SIGLENT
SIGLENT SPS5000X Series User manual

SIGLENT
SIGLENT SPD1000X Series User manual

SIGLENT
SIGLENT SPD3303C Series User manual

SIGLENT
SIGLENT SPD3303S User manual