Installation Instruction
PLEASE READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
1. To prevent personal injury or product damage only licensed electricians should install.
2. To avoid electrical shock or component damage, disconnect power before attempting installation or servicing.
3. This product must be installed in accordance with the national electric code (NEC) and all applicable federal, state and local electric 
 codes and safety standards.
4. Disconnect product and allow cooling prior to any further steps.
5. Any alteration or modification of this product is expressly forbidden as it may cause serious personal injury, death, property damage 
 and/or product malfunction.
6. To prevent product malfunction and/or electrical shock this product must be properly grounded.
7. This luminaire is designed to operate in ambient temperatures ranging from -25°C to 40°C and to be horizontally mounted with the 
 LED board facing downward.
Surface-mounted with J-BOX
1. Loosen the screw on the 
 side of the housing and pull
 out the connecting plate
2. Fix the connecting plate 
 onto the ceiling and put 
 the wire through center 
 hole
 
3. Buckle the connecting plate
 into the clips and connect 
 the wires as following shows
Black Line
White Neutral
Green/Yellow Ground
4. Slide lamp back into the 
 connecting plate and fix 
 the screw that is removed 
 in step one
Pendent Installation with 3/4 inch conduit
1. Loosen the screw on the side of the 
 housing and pull out the connecting 
 plate, 
2. connect the wires as following shows, 
Line
Neutral
Green/Yellow Ground
Black
White
3. Screw the lamp and conduit pole 
 together tightly
Parking Garage Fixture