PUS H DIM
L
N
DA
DA
DALI DIMMER
0-6 0 -9
1-
2-
3-
4-
DA
DA
DA
DA
DAL I
V-
V-
V+
V+
DC IN PUT
12- 36V
LED O UTPUT
PUS H DIM
L
N
DA
DA
DALI DIMMER
0-6 0 -9
1-
2-
3-
4-
DA
DA
DA
DA
DAL I
V-
V-
V+
V+
DC IN PUT
12- 36V
LED O UTPUT
PUS H DIM
L
N
DA
DA
DALI DIMMER
0-6 0 -9
1-
2-
3-
4-
DA
DA
DA
DA
DAL I
V-
V-
V+
V+
DC IN PUT
12- 36V
LED O UTPUT
Note: DALI address can be manually assigned from 00-63-FF, by factory defaults, no DALI address is
assigned for the dimmer, and the display shows . Setting DALI address as will reset the dimmer
to factory defaults.
With DALI master
Wiring diagram
• DO NOT install with power applied to device.
• DO NOT expose the device to moisture.
Product Data
Safety & Warnings
2 groups DALI
signal input & output/
Push switch input
• In compliance with IEC 62386-101:2014, IEC 62386-102:2014, IEC 62386-207 Ed2.
• Match all DALI systems in the market
• Manual /automatically DALI address setting
• Four channels, can set addresses from one to four.
• DALI address digital indicate
• To work with power repeater to expand output power unlimitedly.
• Waterproof grade:IP20
• Push dimmer/DALI dimmer optional
• Built-in DALI-2 interface, DALI DT6 device
1 2
1. Switching of Two Modes
DALI and Push DIM functions cannot be used simultaneously, which can be controlled respectively by DALI
master controllers and push switches.
This product can be operated under DALI Dimmer mode and Push Dimmer mode while connected with DALI
master controllers and push switches respectively.
Operation
2. Set DALI Address Quantity
2.1. Press and hold down both of the two buttons until numeric digital display flashes, then
release the button.
2.2. Click first button to select “1A”, “2A”, “3A” or “4A” which means 1 address, 2 addresses, 3
addresses or 4 addresses.
2.3. Then press and hold down any of the 2 buttons until the numeric digital display stops
flashing to confirm the setting.
3. DALI Address Assigned by DALI Masters
Note: The digital display will show When the DALI master is assigning addresses.
DALI address can also be assigned by DALI Master controller automatically, please refer to user manuals of
compatible DALI Masters for specific operations.
PUSH DIM
L
N
DA
DA
4. Push Dimmer Mode
4.2. Memory function after power off or power failure enables the device to memorize the status before power
off while power on again.
While connected with a AC push switch, the digital display will show “PD” which means Push Dimmer Mode,
operations under Push Dimmer Mode are as follows:
4.1. Click the button to switch ON/OFF
4.2. Press and hold down the button to increase or decrease light intensity to desired level and release it, then
repeat the operation to adjust light intensity to opposite direction. The dimming range is from 1% to 100%.
Set DALI Address Manually Via Buttons
1.1. Press and hold down any of the two buttons until numeric digital display flashes, then release the button.
1.3. Then press and hold down any of the 2 buttons until the numeric digital display stops flashing to confirm the
setting.
1.2. Click any of the two buttons once to select a digit, click again to change the digit until the desired DALI
address appears. Click first button to set “tens” position and second button to set “units” position. The address
can be set from 00~63.
12-36V DC power input
Common Anode output(+)
CH 1:R output(-)
CH 2:G output(-)
CH 3:B output(-)
CH 4:W output(-)
Manual set button
Digital display
DALI Master
L
N
GV+
V-
OUTPUT
INPUT
AC Power
50/60Hz
12V/24V/36V
CV PSU
If Connect with RGBW L ED St rip
V+ V+
R- R-
G- G-
B- B-
W- W-
V+ V+
1- V-
2- V-
3- V-
4- V-
If Connect with S ingle Color LED Strip
V+ V+
WW WW
CW CW
WW WW
CW CW
If Connect with D ual C olor LED Strip
For example, when we set address to 22:
When select 1A, all four channels will be the same address 22.
When select 2A, channel 1 & 3 will be the same address 22, channel 2 & 4 will be the same address 23.
When select 3A, channel 1, 2, 3 will be address 22, 23, 24 respectively, and channel 4 address is also 24.
When select 4A, channel 1, 2, 3, 4 will be address 22, 23, 24, 25 respectively.
Input
Voltage Remarks
Output
Current
12-36VDC Constant voltage
4x(60-180)W
4x5A
Output
Power
12-36VDC Constant current
4x(4.2-12.6)W
4x350mA
12-36VDC Constant current
4x(8.4-25.2)W4x700mA
No.
1
2
3
Size(LxWxH)
170x53.4x28mm
170x53.4x28mm
170x53.4x28mm
2mA
DALI
Consumption
2mA
2mA
0.1%-100%
Dimming
Range
0.1%-100%
0.1%-100%
Ambient
Temperature
-20℃ ~ +50℃
-20℃ ~ +50℃
-20℃ ~ +50℃
DALI DIMMER
0-6 0-9
1-
2-
3-
4-
DA
DA
DA
DA
DALI
V-
V-
V+
V+
DC INPUT
12-36V
Function introduction
Important: Read All Instructions Prior to Installation
9057001
DALI Controller DC/DC 4x8A
LED OUTPUT
PUS H DIM
L
N
DA
DA
DALI DIMMER
0-6 0 -9
1-
2-
3-
4-
DA
DA
DA
DA
DAL I
V-
V-
V+
V+
DC IN PUT
12- 36V
LED O UTPUT
With AC
push dimmer
AC PUSH
SWITCH
N
L
L
N
GV+
V-
OUTPUT
INPUT
AC Power
50/60Hz
12V/24V/36V
CV PSU
V+ V+
1- V-
2- V-
3- V-
4- V-
If Connect with S ingle Color LED Strip
With AC Push Switch
Product Dimension
170 mm
53.4 mm 28 mm
• Immunity standard according to EN 61547:2009
• Radio Frequency Interference according to EN 55015:2013/A1:2015
• Mains current harmonics according to EN 61000-3-2:2014
• Limits for Voltage Fluctuations and Flicker according to EN 61000-3-3:2013
• CE marked
Conformity & Standards
Sigor Licht GmbH
Eichenhofer Weg 81 · 42279 Wuppertal
Telefon 0 23 39 – 12 61 0 · Telefax 0 23 39 - 12 61 61
info@sigor.de · www.sigor.de

Popular Controllers manuals by other brands

maxxess eMAX-LP2500 Specification and installation guide

maxxess

maxxess eMAX-LP2500 Specification and installation guide

Sollae Systems PES-2403 user manual

Sollae Systems

Sollae Systems PES-2403 user manual

Pixel VIS131.1 Operation manual

Pixel

Pixel VIS131.1 Operation manual

Sunricher SR-2812 user manual

Sunricher

Sunricher SR-2812 user manual

Pride Mobility Controller Flight Basic operation instructions

Pride Mobility

Pride Mobility Controller Flight Basic operation instructions

Toshiba V Series Operation manual

Toshiba

Toshiba V Series Operation manual

Flycolor X-CROSS BL-32 user manual

Flycolor

Flycolor X-CROSS BL-32 user manual

ABB ControlMaster CMF manual

ABB

ABB ControlMaster CMF manual

Pixsys PL500 user manual

Pixsys

Pixsys PL500 user manual

Ricoh Fiery E-820 Configuration guide

Ricoh

Ricoh Fiery E-820 Configuration guide

HID EDGE EVO EH400-K installation guide

HID

HID EDGE EVO EH400-K installation guide

Lumens VS-KB30 user manual

Lumens

Lumens VS-KB30 user manual

SOMFY animeo KNX 1860286 installation guide

SOMFY

SOMFY animeo KNX 1860286 installation guide

MOULDPRO Flosense 3.0 user guide

MOULDPRO

MOULDPRO Flosense 3.0 user guide

Unitronics Vision OPLC V130-J-TR20 installation guide

Unitronics

Unitronics Vision OPLC V130-J-TR20 installation guide

Samsung Function controller Owner's instructions

Samsung

Samsung Function controller Owner's instructions

King Pigeon RTU5024 user manual

King Pigeon

King Pigeon RTU5024 user manual

Jobsite V-10-50 Installation & user guide

Jobsite

Jobsite V-10-50 Installation & user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.