Sihon SO-DP10G User manual

SihonElectronicsCo.,Ltd
R
SO-DP10G


COMPANY
PROFILE
Sihon Electronics Co., Ltd. Was Established In The Year Of 2007. It Lies In The City Of
Tianchang,china.
We Mainly Produce Ozone Generator And Various Models Of The Ozone Power, Ozone
Ceramic Plate, Ozone Tube And Ozonizer, Etc.
We Also Export The Anion Generator, Charger, And All Kinds Of Ignition For Various
Applications Of High Pressure Generator Different Models Of Anion Power,variety Of
Electronic Anti-riots Etc, For Public Security Agencies And Other Security Units.
We Have Set Up A Strict Test System For Materials And Products. Each Piece Of The
Product Must Pass The Quality Checkout. All Our Products Pass The ISO9001:2000
Standard, Iec And Mil. We Also Passed The Ccc, Ce, Rohs Certification Successfully
In Near Years.

I.Overview
Thank you for purchasing the ozone sterilization anddisinfection
machine. In order to use the ozone sterilization and disinfection
machine correctly, please read the instruction manual carefully
before use.
This product is simple in design, small and portable,easy to
operate, low noise, and durable. (Non-professional maintenance
personnel, please do not disassemble this machine).
II.Introduction
warning
Please make sure the room you need to deal with
Or no people or animals in the place
WORKINGPRINCIPLE
Ozone is produced by ceramic sheethigh frequency and high press
-ureprinciple,airsource is air source,noother raw materials.
AIRPURIFIERFUNCTIONLTUTILIZES
R
-1-
Tel&Whatsapp&Wechat : 0086-18098384778
E-mail:[email protected] Web:www.sihon-ozone.com / www.cnxhe.com
The wide spectrum,hugh efficiency and rapid sterilization function
of ozonelndoor air disinfection so that a variety of bacteria such as
fungi bacteria eggs The white matter shell is oxidized to kill bacterial
propagators and spores,Virus,fungus,etc.Use ozone and a variety
of toxic ingredients in the air(e.g.formaldehyde,benzene,ammonia,
smoke and odour smelling organic matter Produce oxidation reaction,
eliminate odor and remove its toxicity. Ozone:ozone is a widely
recognized and highly effective fungicide.In recent years more and
more areapplied to various fields,ozone chemistrylt is especially active
and is a strong oxidizing agent at a certain concentratio Under can

PRECAUTIONSFORINSTALLATIONANDUSE
1. The ozone disinfection machine should be placed as high
as possible. The power can be touched by raising the flat
arm. There should be no covering around the host.
2. Do not insert foreign objects into the air outlet of the ozone
disinfection machine to avoid danger.
3. The user shall not modify any device of the original product
by himself.
4. There is high voltage in the machine, do not open the cover
casually, and do not extend your hands or objects into the
swinging leaf to prevent electric shock.
5. During the use of the product,if there is any abnormal situation,
it should be cut immediately power off,and the company’s
after-sales service.
R
-2-
Tel&Whatsapp&Wechat : 0086-18098384778
E-mail:[email protected] Web:www.sihon-ozone.com / www.cnxhe.com
quickly kill bacterial reproduction and spores,viruses,fungi,etc.
And can destroy the botulinum toxin,can remove and kill air,water,
Toxic substances and bacteria in food,remove odor,common big
Enterobacterium,streptococcus faecalis,pseudomonas aeruginosa,
staphylococcus aureus,In the ozone environment,the killing rate
of 15 munutes is more than 99%.
Certain concentration of ozone is harmless to the human body, the
human sense of smell is extremely sensitive,used for air sterilization
of ozone concentration is generally 0.25 to 2.5 parts per million,and the
human experience of 0.01 parts per million,Exposure at a concentration
of 0.1 PPM is allowed for 10 hours according to the national ministry of
health Will not have any impact on people and damage(industrial
hygiene standards for 0.15 parts per million(PPM).At the same time,
ozone sterilization and odor removal without residue,Because of its
instability,ozine is rapidly reduced to oxygen in the airGas,no residue,
no secondary pollution.

Timer knob
III.ProductParameters
Model :
Voltage:
Power:
Flow Rate:
Ozone Production:
Noise:
Product Size:
Cooling Method:
Gas :
Suit Space:
Product Weight:
IV.ProductPicture
SO-DP10G
110V / 220V
90W
90CFM
10g/h
35 dB
220×210×200mm
Air Cooling
Air
100m
2.5Kgs
2
R
-3-
Tel&Whatsapp&Wechat : 0086-18098384778
E-mail:[email protected] Web:www.sihon-ozone.com / www.cnxhe.com
Handle

V.ProductInstructions
VI.Use Place
1. Family: used for disinfection and sterilization of living rooms,
kitchens, rooms, carpets, etc. to remove odors;
2. Public places: indoor disinfection and air purification of enterprises
and institutions, hotels, hotels, restaurants,beauty salons, KTV,
mahjong halls, etc .;
3. Internal cleaning, disinfection and sterilization of cars, trains,
yachts, etc .;
4. Air purification and disinfection in hospitals and nursing homes;
5. New buildings, interior decoration pollutants: such as formaldehyde,
benzene, TVOC, preservatives, etc .;
6. Disinfection and sterilization of food workshops,sterile rooms,
changing rooms, warehouses and related appliances;
7. Breeding industry: regular disinfection and sterilization of space;
8. Warehouse and cold room: disinfection and sterilization;
9. Others: any place where air needs to be disinfected and sterilized,
any place where odor needs to be eliminated.
R
-4-
Tel&Whatsapp&Wechat : 0086-18098384778
E-mail:[email protected] Web:www.sihon-ozone.com / www.cnxhe.com
2. After the power is turned on, the indicator light is on;
4. After the set working time is completed, the machine will
shut down automatically;
5. Please conduct ventilate treatment after the machine is closed
for 40 minutes,e.g Open doors,Windows,etc.
1. Ensure that there are no people and animals in the room or
place to be displsed of;
3. According to the need to set the timer time,clockwise rotation
Timer,set the specific time to work,time setting range for 5 to
120 minutes;

VII.Maintenance
When the air purifier works, it produces very little ozone,or when
no ozone is produced,new quartz tubes need to be replaced,
usuallyunder the circumstance,the quartz tube needs to be replaced
after working 5000 hours.
REPLACEQUARTZTUBE:
1. Unplug the power cord;
2. Remove the screws around the lid and open the lid;
3. Gently sway the old quartz tube,to be loose after pulling out old
quartz tube;
4. Install the new quartz tube completely on the bracket and buckle
the bracket lockbuckle.
R
-5-
Tel&Whatsapp&Wechat : 0086-18098384778
E-mail:[email protected] Web:www.sihon-ozone.com / www.cnxhe.com

Table of contents
Other Sihon Air Cleaner manuals
Popular Air Cleaner manuals by other brands

Philips
Philips MicroCube AC5659 quick start guide

Dust Free
Dust Free CARBON 13052 Installation & operation manual

Ultravation
Ultravation PHOTRONIC UVMatrix CW Series owner's guide

Bionaire
Bionaire BAP520-CN Instruction leaflet

Lennox
Lennox PureAir PCO3S-14-16 installation instructions

Philips
Philips GoPure GP5212 user manual