SI-3 is delivered as single pole 16A version and dual pole 10A version. This manual
applies to both versions. The connections are the same.
Technical specifications
Manufacturer: Sikom AS, Norway
Type/Model: Wireless thermostat SI-3 300-8063V10/300-8064V10
Compatible with: Comfort and ECO system
Operating voltage: 230VAC
Max load: Single pole version 16A. Dual pole version 10A.
Regulation: P-Regulator. 0-100%
Measurement range: 0°C to +45°C ±2°C
Regulation range: 5°C to +40°C
Operating temp.: 0°C to +45°C
Color: White (polar white, similar to RAL 9010)
Radio Frequency: 433.9 MHz
Sealing: IP20
Complies with the European R&TTE directive.
Designed for indoor use only.
Package contents
•Wireless thermostat
•Front cover and frame.
•Temperature sensor with 3m cable. Called “sensor” in the following.
Do not expose the sensor cable to the sun or UV lighting.
NB:
This thermostat does not offer galvanic separation between high and low
voltages. The sensor must therefore be regarded as a high voltage cable.
Wireless thermostat SI-3
Installation and user guide

Please leave this guide to the end user
64 000 13 Monteringsanvisning Termostat SI-3 Eng Rev1.0.docx.0 www.sikom.no
Installation
Sensor:
The standard sensor on the thermostat is a floor sensor from Sikom.
A room sensor and/or floor sensor can be used. The room sensor is integrated in the
thermostat. To activate this sensor, see the programming instructions.
The wire from thermostat to sensor should be as short as possible.
Room sensor: If the room sensor is used, the temperature will be measured at the
thermostat. Do not place the thermostat in direct sunlight or close to other heat sources.
Do not place it on an external wall or in zones exposed to draughts from windows or
doors.
Floor sensor: If the sensor is to be placed under the floor, it must be right in the middle
of two heating cable segments, and as close to the surface as possible. The sensor wire
should not be laid out near high current cables. The sensor should be placed inside a pipe
that is grounded or covered with a grounded net. The pipe should also be closed at the
sensor extremity. The installation shall be equipped with an earth leakage circuit breaker.
All standard installation regulations must be followed.
Installation:
Connect 230V wires and floor sensor (if required) as shown in the figure below. Place the
plastic frame on top of the thermostat (bottom part) before connecting the gray 10-lead
cable to the front cover. Snap the front cover in place in the frame.
Floor sensor
LOUT%%%LIN%%%NOUT%NIN%%%G
Load
N
230VAC
Thermostat SI-3
(Front view of bottom part)
L
L
N

Please leave this guide to the end user
64 000 13 Monteringsanvisning Termostat SI-3 Eng Rev1.0.docx.0 www.sikom.no
Registration with the central unit
Registration ECO system:
•On the central unit, select the “Setup” screen,
then “Register new device” (follow these icons):
•Activate the registration procedure on the thermostat by menu P7
•”Registration OK” and a number will now be shown in the display of the central unit.
Take note of this number for the end user; this number will be used for remote
control of the thermostat.
Registration Comfort system:
•Select menu 8 on the central unit.
•Select submenu 1 and press OK.
•Activate the registration procedure on the thermostat by menu P7
•”Registration OK” and a number will now be shown in the display of the central unit.
Take note of this number for the end user; this number will be used for remote
control of the thermostat.
Display and LEDs
•Element on/off: Lights when the heating element receives current.
•Comfort: Comfort mode active.
•Eco: Eco mode active.
•On/Off switch: On mode or standby mode.
•Programming: PProgramming switch.
SIKOM AS
SI-2
20
P
!

Please leave this guide to the end user
64 000 13 Monteringsanvisning Termostat SI-3 Eng Rev1.0.docx.0 www.sikom.no
Possible errors
•E0: Floor sensor faulty.
•E1: Faulty radio. No communication with the central unit.
•E2: Overheating inside the thermostat. Check the load.
•E3: Faulty overheating measurement. Contact dealer.
•E4: Faulty room sensor. Contact dealer.
Errors will be shown in the display if there is something wrong with the functionality.
If the thermostat is overheated, it will turn off the output relay until the temperature
inside the unit is normal again.
If there is something wrong with the sensor, the thermostat will shut down. An error will
be shown in the display.
Operation
The thermostat can be configured and operated either remotely (e.g. by SMS messaging)
or locally from the central unit, or finally directly via the thermostat buttons. Please refer
to the manual of the central unit for further information.
The thermostat will automatically dim the display after a while. Before the thermostat
can be operated manually you must press any button to reactivate the display.
Switching between eco and comfort modes:
Press the up button to set comfort mode -> Green led will light.
Press the down button to set eco mode -> Red led will light.
Adjusting the target temperature:
First, follow the above instructions to set the thermostat into the mode (eco or comfort)
to be adjusted.
•Press the «P» button. Dots will start blinking in the display, and the set temperature
will be shown for that mode.
•Use the up and down buttons to adjust the target temperature.
•Press the «P» button to store the temperature setting.
Advanced operation:
The thermostat has an advanced menu for registration and settings.
This menu is activated as follows:
•Turn off the thermostat by using the power button.
•Press the «on/off» switch simultaneously with the «up» switch and release both
after 5 seconds.
•The thermostat will display «P1»
Menu Explanation MIN MAX Standard
P1: Floor sensor type. 1 6 6
P2: Max temp in floor. 25 30 27
P3: Temperature compensation. -5 5 0
P4: Dimming. 0 45 30
P5: Thermostat type. 1 3 1
P6: Cycle time. 10 50 10
P7: Registration.
To navigate between the menus, press the «P» button repeatedly. «P1 to P7» will be
shown on the display. When you have reached the desired menu, wait until the setting
for that menu is displayed. Adjust the setting with the up and down buttons. When
settings are adjusted, press the «on/off» button to exit the advanced menu.

Please leave this guide to the end user
64 000 13 Monteringsanvisning Termostat SI-3 Eng Rev1.0.docx.0 www.sikom.no
P1: Floor sensor type:
6 temperature sensors are supported. Choose the correct one according to the sensor
type used. The default value is the Sikom sensor.
Note: If room sensor is chosen in P5, this menu has no effect.
1. Microsafe
2. Microtemp
3. Devi
4. Elko
5. Ebeco
6. Sikom
P2: Max temp in floor:
If the maximum temperature in floor function is activated, the temperature limit can be
adjusted here. As soon as the floor sensor measures this temperature, the heat element
will be turned off even though the room sensor measures lower temperature.
P3: Adjusting temperature compensation:
The thermostat can be compensated if the displayed temperature is too high/low. The
need for compensation is more frequent when the sensor is located under the floor. The
compensation can be from -5ºC to +5ºC. This means that if the sensor measures 30ºC
degrees and the compensation is set to -5ºC degrees, this will be reflected by the
display, which will then show 25ºC degrees instead of 30ºC.
P4: Adjusting dimming value:
After a couple of minutes, the lights on the thermostat will dim. The dimming can be
adjusted by this menu. The range is 0-45, where 0 is the weakest brightness.
P5: Thermostat type:
The thermostat can operate in 3 different ways:
1. Floor sensor. The thermostat measures temperature by the floor sensor.
2. Room sensor. The thermostat measures temperature by built in room sensor.
3. Maxtemp. The thermostat measures temperature by the room sensor, but
limits the actual temperature in the floor by limit set in «P2». This
temperature is measured by the floor sensor.
P6: Cycle time:
The heating element will be turned on and off 0-100% with a cycle time which can be
adjusted in this menu. The interval can be from 10 to 50 minutes. The heating element
will be switched on/off about once in this time interval based on the regulation
calculation.
P7: Registration:
Use this menu to register the thermostat with the central unit.
Activate the registration procedure on the central, and press «up» button when «--» is
shown in the display. Wait until the registration completes successfully.

Please leave this guide to the end user
64 000 13 Monteringsanvisning Termostat SI-3 Eng Rev1.0.docx.0 www.sikom.no
Compliance with international regulations
This equipment complies with the European R&TTE directive. Further information may be
obtained by contacting either www.EcoStarter.com or the manufacturer:
Sikom AS (www.sikom.no)
WARRANTY
Sikom A.S. products are covered by a two years warranty against any faults due to
material flaws or manufacturing errors, which limit or render useless certain functions
described for the product. The warranty requires the customer to present the original bill,
with date of purchase and type of equipment clearly readable.
What is covered by the warranty?
During the warranty period, Sikom A.S. reserves the right to repair the product or to
replace defective parts with functionally equivalent parts. If, after several attempts,
Sikom A.S. is unable to correct the problem, and the product does not work as described
in the manual, Sikom may elect to refund the purchase price or to replace the product
with a functionally equivalent one. All replaced parts and products become the property
of Sikom A.S.
What is not covered by the warranty?
•Indirect damage to life, health, property, revenue and environment caused by circuits
and appliances connected to the units (install and use this product responsibly).
•Costs related to (re)installing, transporting and dismantling units; recycling may be
governed by special rules (see the relevant chapter).
•Damages caused by use outside of the operating conditions specified in the manual.
•Malfunctions caused by transport damages.
•Any unauthorized repair, modification or disassembly.
•Use of non-original parts.
•External factors, such as lightning, power supply issues, mobile network issues, flood
damage or fire.
•Units with modified, removed or unreadable serial number.
Sikom assumes no responsibility for any errors that may appear in this manual.
Information contained herein is subject to change without notice.
RECYCLING INFORMATION
The WEEE (Waste Electrical and Electronic Equipment) symbol indicates that this product
must not be disposed of along with other household waste. It is the customer's
responsibility to dispose of the product properly by taking it to a designated site for
recycling. To locate a recycling/disposal site near you, contact your local city recycling
program, your regular waste disposal service or the agent from whom you purchased this
product.
For Switzerland, this product includes in its purchase price a contribution (the advanced
recycling fee) to the SWICO Recycling Warranty, which means that used equipment can
be handed in free of charge for recycling. Collection sites are listed at
www.swicorecycling.ch.
Table of contents
Other SiKom Thermostat manuals
Popular Thermostat manuals by other brands

Vaillant
Vaillant VRT 15 installation instructions

White Rodgers
White Rodgers 1F80-51 Installation and operation instructions

Secure
Secure STP328 quick start guide

Honeywell
Honeywell TRADELINE Y594 Installation, instruction and service manual

LUX
LUX ELV4 Troubleshooting

Honeywell
Honeywell TL8100A1008 - Line Voltage Thermostat user guide

Honeywell
Honeywell EVOTOUCH CONTROLLER user guide

Sensi
Sensi 1F95U-42WF Series Navigation & Scheduling guide

Vive Comfort
Vive Comfort TP-S-701i installation instructions

TIS
TIS TERRE Series installation manual

URC
URC THZ-100 owner's manual

American Standard
American Standard Ceratherm T050.541 installation instructions