2% SLOPE2% SLOPE
2% SLOPE2% SLOPE
OROR
2% SLOPE2% SLOPE
2% SLOPE
AirVentAirVent
AirVentAirVent
AirVentAirVent
LONG SWEEPING 90°ELBOWLONG SWEEPING 90°ELBOW
2 PCS 45° ELBOW2 PCS 45° ELBOW
OROR
Diagram B
DO NOT DROP
BREAKABLE CERAMIC
TOILET
17 Lbs - SVP-600A
28 Lbs - SVT-220
MACERATING BLADES
INSIDE
PERSONAL PROTECTIVE
EQUIPMENT NEEDED
DURING INSTALLATION
GENERAL SAFETY DURING USE
Ensure all power sources conform to the equipment's 110 Volts requirement and ensure the power source is not
connected during installation
Installation of the Ground Fault Circuit Interruptor (GFCI) must follow The National Electrical Code (NEC), or NFPA 70
standards.
Electrical cords may be trip hazards.
In the event of a power loss, do not use the toilet or any other sanitary fixture connected to the macerating unit
since the Macerator Pump will not work until the power is restored.
Do NOT immerse the macerator unit in water.
Please feel free to reach out to our Customer Care Center with any questions you may have; our email address is
[email protected], our
Customer Care direct line is (800) 972 8597. For a more detailed guide please check our help section on the web at http://www.silentvenus.com.
9. Secure the connection
between the toilet and
Macerator pump inlet.
10. Connect the side inlets to
the Macerator pump.
11. Connect the
discharge pipe.
Secure the connection
with provided metal
clamps.
7. Connect the water inlet to
the existing water supply
and test for leaks.
8. Align the connection
between the toilet and
Macerator pump inlet.
TIP
To attain its full efficiency, a straight vertical is
recommended. If it is necessary to extend the pipe
before the vertical run, only a maximum of 12
inches horizontal distance is allowed.
Use a ¾“⌀ or 1”⌀ reducer from the outlet to the
discharge pipe.
12. Complete all inlet and
outlet connections making
sure there are no water
leaks.
13. Plug the macerator into
an electrical outlet
protected with the GFCI and
test the unit.
78
910
12 13
11
Diagram A