Simply Automated SimplyBrilliant US11-30 User manual

Standard Dimming Transceiver Switch Model US11-30
Simply Automated, Incorporated
5825 Avenida Encinas, Suite 101, Carlsbad, CA 92008 USA
Technical Support: www.simply-automated.com or 800-630-9234
Revised: August 15, 2005
TROUBLESHOOTING
PROBLEM PROBABLE CAUSE SOLUTION
Master switch is wired
properly but has no power. Air gap power disconnect may be disengaged
(pulled out). Push light pipe (indicator) back into position flush with faceplate
assembly housing.
3-way remote switch actuator may be binding,
causing the switch to be stuck ON or OFF. Loosen mounting screws on remote switch and/or wallplate to
relieve pressure on housing.
Master switch actuator
doesn’t turn load ON
and/or OFF. Actuator faceplate may not be seated properly
on the switch body. Exercise actuator several times to ensure proper seating and
operation.
Mounting screws may be too tight or j-box may
be deformed, causing the switch body to warp. Loosen mounting screws to relieve pressure on the switch
housing.
Rocker sticks or doesn’t
actuate properly when
pressed. Actuator springs may have backed out of their
correct location during shipping. Reseat the springs: place the faceplate face-up on a flat surface,
then press down on both sides of each rocker at the same time.
Switch is overloaded. Reduce the power load by removing bulbs from the circuit.
Switch runs hot when
dimming the load. Switch is dimming a load that is not rated for
use with incandescent dimmers. Reconfigure the switch for ON/OFF operation with no dimming
(using UPStart, for example).
UPB FACTORY DEFAULT SETTINGS
To restore the following default settings, place the US1 in SETUP mode
and tap any actuator exactly 10 times. The indicator will continuously
blink RED. Tap the actuator twice again to exit SETUP mode.
Network Name “Network 1”
Room Name “New Room Name”
Device Name “New SA US1/US2”
Unit ID 22
Network ID 255
Network Password 1234
Transmit Link 1
Receive Links 1 (ON) and 2(OFF)
POWER DISCONNECTION
To physically disconnect power to the connected lamp fixture, depress
the top of the rocker switch, grab the underside of the clear plastic
indicator tab with your fingernail, pull the tab out about 0.05”, then push
the tab down to lock it in place. The indicator will extinguish to show
that power is now disconnected. To reconnect power, simply push the
tab up and it will snap back into its normal position.
Simply Automated, Incorporated
5825 Avenida Encinas, Suite 101, Carlsbad, CA 92008 USA
Technical Support: www.simply-automated.com or 800-630-9234
Revised: August 15, 2005
UPB Standard Dimming Transceiver Switch
Model US11-30
Provides ON/OFF and dimming control for:
•Incandescent lighting
•Magnetic low-voltage lighting
•Halogen lighting
IMPORTANT!
Read This Before Installing!
•This incandescent dimmer cannot be used to dim
FLUORESCENT, ELECTRONIC LOW-VOLTAGE or
METAL HALIDE lighting, unless specifically
allowed by the lighting manufacturer. Please see
instructions to configure this product for ON/OFF
operation with these types of lighting.
•DO NOT WIRE HOT! Permanent damage may
result. Improper installation voids the warranty.
Model US11-30 shown with actuator faceplate
FUNCTION
The SimplyBrilliant™ UPB Dimming Transceiver Switch, model US11-30,
allows remote control of permanently-installed new or existing lighting
fixtures, lamps and other electrical devices. Each unit has one rocker
switch that directly controls a load up to 900W. Incandescent lamps can
be turned ON or OFF, and can also be dimmed and brightened. The
US11-30 can be configured to turn other types of non-dimmable loads ON
and OFF. The switch also acts as a transmitter that can communicate
with other UPB devices, either individually or collectively for lighting
scenes.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical products, basic safety precautions should always
be followed, including the following:
1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2. REMOVE YELLOW “INSTALL WITH CARE” LABEL BEFORE
INSTALLING.
3. Installation should be performed by a qualified electrician.
4. Keep away from water. If product comes into contact with water or
other liquid, disconnect immediately.
5. Never use products that have been dropped or damaged.
6. Do not use this product outdoors.
7. Do not use this product for other than its intended use.
8. Do not connect multiple lamps that, when combined, exceed the
maximum load rating of the product, de-rated for multi-gang boxes.
9. Do not install in areas that can exceed 120°F (e.g., in an attic).
10. To avoid the risk of overheating and possible damage to other
equipment, do not use this product to control a receptacle.
11. Do not cover the product with any material when in use.
12. SAVE THESE INSTRUCTIONS.
INSTALLATION
The SimplyBrilliant™ UPB Dimming Transceiver Switch (US11-30) is
designed to be installed in a junction box that is wired to a readily
accessible over-current protection device in the building wiring per NEC
and CEC electrical codes.
CAUTION: The default switch configuration operates as a dimmer for
incandescent lamps. It will also dim magnetic low-voltage and
halogen lamps. To control fluorescent, electronic low-voltage or
metal halide lamps, or motor-operated appliances, transformer-
supplied appliances or fans, the switch must be reconfigured for
ON/OFF operation (no dimming) prior to use. Refer to the section on
Configuration.
CAUTION: DO NOT WIRE THIS DEVICE WITH POWER
CONNECTED. Injury or permanent damage to the device
may result. Improper installation voids the product warranty.
1. Locate the existing wall switch for the lighting to be controlled. Note
that the lamp rating (or the combined rating of all connected lamps)
must not exceed what is shown in the de-rating table below.
Number of Load
Dimmers in J-box
123+
1600W -- --
2800W 500W --
Number
of J-box
Gangs 3+ 900W 700W 500W
2. Disconnect power at the circuit breaker.
3. Remove the existing wall switch hardware. Disconnect the wires to
the switch.
4. Remove the yellow “INSTALL WITH CARE” label, if present.
5. Using a wire nut, connect the black (Line) wire of the switch to the
black (Line) power wire.
6. Using a wire nut, connect all white (Neutral) wires together.
7. Using a wire nut, connect the brown (load output) wire of the US11-
30 to the black wire of the device to be controlled.
8. IF THIS IS TO BE A 3- OR MORE-WAY INSTALLATION, use a wire
nut to connect the brown/white wire to the traveler wire that extends
to the slave switch. If there is a second slave and a second traveler,
use a wire nut to connect the red/white traveler to the wire that
extends to the second slave switch location. Refer to the wiring
diagrams on pages 3 and 4.
9. Mount the switch inside the J-box using captive screws. DO NOT
OVER TIGHTEN THE SCREWS.
10. Reconnect power at the circuit breaker.

Standard Dimming Transceiver Switch Model US11-30
REMOTE SWITCH INSTALLATION
To install a USR Dedicated Remote switch for 3- or more-way control:
1. Locate the remote switch that is connected to the master wall
switch.
2. Disconnect power at the circuit breaker.
3. Remove the existing wall switch hardware. Disconnect the wires
to the existing 3-way switch.
4. Using a wire nut, connect the white (Neutral) wire of the USR to
the white (Neutral) power wire.
5. Using a wire nut, connect the brown/white wire of the USR to the
traveler wire that extends to the master switch.
6. To use the second switch of a dual slave configuration, connect
the red/white wire to the traveler wire that extends to the second
master switch.
7. OPTIONAL: Using a wire nut, connect the brown wire (black on
some models) of the USR to the switched load wire or to the black
(Line) power wire. This powers the LED indicator. If connected to
the switched load wire, the LED will illuminate when the load is on.
If connected to line power, the LED will always be on.
8. Cap off any unused wires to prevent shorting.
9. Mount the switch inside the J-box using existing screws. DO NOT
OVER TIGHTEN SCREWS.
10. Reconnect power at the circuit breaker.
CONFIGURATION
Configuration requires UPB setup/configuration software and a model
UMC Computer Interface Module. Before using UPStart configuration
software, be sure to download the latest version from the Simply
Automated website.
The US11-30 default settings assume a ZS11 (single rocker) faceplate.
The device will not operate correctly with any other model of
faceplate. Because US11-30 and US2-30 devices use the same
Product ID code, UPB settings must be properly configured. When
using UPStart, this is done by selecting the US11 Single Rocker
faceplate “variant” when adding the device to the network.
SETUP MODE
When configuring a UPB system, it is often necessary to place the
US11 in SETUP mode in order to initiate self-identification on the
powerline. To place the US11 in SETUP mode, tap any
rocker/pushbutton exactly 5 times consecutively. The LED indicator will
continuously blink GREEN when the unit is in SETUP mode. To exit
SETUP mode and enter NORMAL mode, tap the rocker/pushbutton
twice again.
OPERATION
Unless otherwise configured, rocker actuator behaves as follows:
Dimmer Action
Rocker Event Top Rocker Bottom Rocker
Single-Tap Brighten to 100% at
Default Rate Fade to 0% at
Default Rate
Double-Tap Snap to 100% Snap to 0%
Hold Start brightening to
100% at Default Rate Start fading to 0%
at Default Rate
Release Stop brightening and
hold current level Stop fading and
hold current level
1. By linking a transmitting switch to a UPB Receptacle, Appliance
Module or Relay Module, the connected load can be turned ON by
tapping the top of the rocker and OFF by tapping the bottom of the
rocker.
2. By linking a transmitting switch to a UPB Lamp or Fixture Dimmer
Module, the connected load can be controlled according to the
table above.
INSTALLING/CHANGING FACEPLATES
SimplyBrilliant Dimming Wall Switches are designed with removable
actuator faceplates, making it possible to change color in the field
without disconnecting the switch from the wall.
To install a faceplate assembly, do the following:
1. Hold the rocker faceplate assembly so that clear plastic light pipe
(LED) on the switch fits nicely into the recess on the top of the
rocker.
2. Align the four prongs on the rocker assembly with the four slots on
the switch body.
3. Press the rocker faceplate assembly into the switch body. Ensure
that all four prongs are fully inserted and latched into the switch
body. If all four prongs are not fully latched, the rocker plungers
may not function properly.
4. Exercise rocker actuator several times in both directions to ensure
proper seating and operation
To remove the faceplate assembly to upgrade functionality
or to change color, do the following:
1. Remove the wall plate from the switch.
2. Using the thumb and index finger, press the top two prongs of the
rocker faceplate assembly inward so that they unlatch from the
switch body AND at the same time, using your thumbnail, slightly
lift up the clear plastic light pipe. This will release the top of the
rocker assembly.
3. Press the two lower prongs inward, and pull the faceplate
assembly away and slightly downward from the switch body,
moving it away from the clear plastic light pipe.
4. Once the old rocker faceplate is removed, follow steps 1-4 above
for instructions on installing a new rocker faceplate assembly.
Standard Dimming Transceiver Switch Model US11-30
Other Simply Automated Switch manuals
Popular Switch manuals by other brands

yellow jacket
yellow jacket 93117 quick start guide

Enterasys
Enterasys SmartSwitch 2200 Installation & user guide

Perle
Perle IOLAN SDG4 W quick start guide

Pilz
Pilz PSEN sl-0.5p 6.1 operating manual

Hewlett Packard Enterprise
Hewlett Packard Enterprise Aruba 2530 Advanced traffic management guide

StarTech.com
StarTech.com VS421HD4KA Quick install guide