Sipura Technology SPA-2100 User manual

csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
User Manual
Sipura SPA-2100 ATA
with PC Router
January 2005 v1
Linhagratuita
grupo csdata
www.linhagratuita.com.br

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
Dis laimer – Please Read:
This document contains implementation examples and techniques using Sipura Technology,
Inc. and, in some instances, other company’s technology and products and is a
recommendation only and does not constitute any legal arrangement between Sipura
Technology, Inc. and the reader, either written or implied. The conclusions reached and
recommendations and statements made are based on generic network, service and
application requirements and should be regarded as a guide to assist you in orming your own
opinions and decision regarding your particular situation. As well, Sipura Technology reserves
the right to change the eatures and unctionalities or products described in this document at
any time. These changes may involve changes to the described solutions over time.
Use of Proprietary Information and Copyright
Noti e:
This document contains proprietary in ormation that is to be used only Sipura Technology
customers. Any unauthorized disclosure, copying, distribution, or use o this in ormation is
prohibited.
Please Note:
Design and speci ications are subject to change without notice.
2

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
Complian e and Safety Information:
This equipment has been tested and ound to comply with the limits or a Class B digital
device in accordance with the speci ications in part 15 o the FCC rules. This product bears
the CE Marking indicating compliance with the 89/336/EEC directive. Standards to which
con ormity is Declared: EN 61000-4-2:1995, EN 61000-4-3:1997, EN 61000-4-4:1995, EN
61000-4-5:1995, EN 61000-4-6:1996, EN61000-4-8:1994, EN 61000-4-11:1994, EN 61000-
3-2:2001, EN 61000-3-3:1995 & EN 55022:1998 Class B Modi ications to this product not
authorized by Sipura Technology could void FCC approval, terminating end user authority to
use this product.
For Indoor Use Only.
Read installation instructions be ore connecting to a power source. The electric plug and
socket must be accessible at all times as this is the main method to disconnect power rom
the device.
Sho k Hazard:
Do not operate near water or similar luid.
Do not work with this device during periods o lightning activity.
Do not touch wires at the end o cables or within sockets.
One Year Limited Hardware Warranty:
Sipura Technology provides a one (1) year limited hardware warranty. Sipura warrants
customer that this product will con orm to its published speci ications and will be ree rom
de ects in material and workmanship at the time o delivery and or a period o one year
therea ter. Without limiting the oregoing, this warranty does not cover any de ect resulting
rom (i) any design or speci ication supplied by an entity other than Sipura, (ii)
nonobservance o technical operating parameters (e.g., exceeding limiting values), or (iii)
misuse, abuse, abnormal conditions or alteration by anyone other than Sipura.
Repla ement, Repair, Refund:
A ter the receipt o an RMA (Return Materials Authorization) request, Sipura will attempt to
re und, repair or replace the SPA. To receive an RMA number contact the party rom whom
you purchased the SPA.
3

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
SPA-2100 Installation:
Step 1: Network Installation Instru tions
A. Please Check to Make Sure That You Have the Following Package Contents:
1. Sipura SPA-2100 Unit
2. Ethernet Cable
3. SPA-2100 Quickstart Guide
4. 5 Volt Power Adapter
B. You Will Also Need:
1. One or Two Analog Touch Tone Telephones (or Fax Machine
2. Access to Your Cable or DSL Modem and the Attached Ethernet Cable
3. Access to PC That Will Connect to the PC Port o the SPA-2100 with a web browser.
C. Connect the Networked Devices with Ethernet Cables:
1. Power down all the devices you will be networking: Cable/DSL Modem, PC, SPA-
2100.
2. Connect an Ethernet cable rom the Cable or DSL Modem to the “WAN” port o the
SPA-2100.
Note: I you are connecting the SPA-2100 to a local area or home network, connect
an Ethernet cable rom the WAN port o the SPA-2100 to the PC port on your
network switch/router.
Do not connect the SPA-2100 WAN Port to an Ethernet hub.
3. Connect an Ethernet cable rom the PC Ethernet adapter port to the SPA-2100 PC
port.
Note: You may also connect an Ethernet switch or hub to the SPA-2100 PC port.
Step 2: Telephone / Fax Installation and Power-UP
From the Rear o the SPA-2100:
A. Insert a standard RJ-11 telephone cable into the SPA-2100 PHONE 1 port.
B. Connect the other end o the cable to an analog telephone or ax machine.
C. Insert a standard RJ-11 telephone cable into the SPA-2100 PHONE 2 port (Optional).
D. Connect the other end o the cable to an analog telephone or ax machine.
Note: Do not connect RJ-11 telephone cable rom the SPA-2100 to the wall jack to prevent
any chance o connection to the circuit switched telco network.
You may now insert the plug end o the power adapter into a live power outlet which will
power up the SPA-2100. At this time, you may now power on the Cable / DSL modem and
the PC connected to the SPA-2100 LAN port.
4

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
Step 3: PC Configuration
Con igure the PC That Will Connect to the Internet Through the SPA-2100:
A. Open the “Local Area Connection” settings menu o the PC.
- Windows XP: “Start - Settings - Control Panel - Network Connections”.
- Windows 2000: “Start - Settings - Control Panel - Network and Dial-up Connections”.
- Windows 95, 98, Millenium: “Start - Settings - Control Panel - Network”.
B. Select “Local Area Connection”. An “Item List” will be visible in the window. Select the
Internet Protocol (TCP/IP) line item applicable or the Ethernet adapter used to connect
to the SPA-2100.
Note: Do not choose a TCP/IP setting associated with AOL, VPN, PPPoE or DUN. I there
is no TCP/IP entry, re er to the PC Ethernet adapter installation documentation to install
TCP/IP on the PC.
C. Select the “Properties” button.
D. Select the IP Address con iguration tab and select “Obtain and IP address automatically”
E. Select “OK” on the TCP/IP Properties screen and select “OK” on the “Network” screen.
F. Restart the PC.
5

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
Step 4: Network and Servi e Configuration Settings
Precon iguration o network and service may have been provided by the service provider or
network administrator who supplied this unit. Depending on the con iguration policy, end user
access to local con igurator settings may be restricted or inaccessible. I end user
con iguration is allowed, some o the key network and service con iguration setting
instructions are described in the ollowing sections pertaining to router con iguration and
voice service con iguration.
To lo ally onfigure the SPA-2100, the user should have the following information
from their servi e provider (ISP) or network administrator:
1. IP Adress, Sub-Net and Gateway or DHCP or PPPoE In ormation
IF PPPoE, the User Name and Password will be required.
2. SIP Proxy Address and Registration In ormation.
3. SIP Service Subscriber In ormation, e.g. User ID, Password
Open a web browser and enter 192.168.0.1/admin/advan ed into the Address ield and
press the Enter key.
With the Router menu active, select the WAN tab to expose the WAN con iguration page o
the SPA-2100. Follow the instructions below depending on the method by which the SPA-
2100 willconnect to the Internet.
6
1. DHCP –
Obtain an IP Address
Automati ally:
I the ISP c
onnects you via a
dynamic IP address or DHCP,
per orm these steps:
A.
Select DHCP as the Connection
Type in
the Internet Connection
Settings area o the web page.
B.
Select the Submit All Changes
button to save the setting.
C. I you use a cable modem, you
may need to con igure MAC
Address Spoo ing (see below).
2. Stati IP Address
Configuration:
I the ISP connects you via a ixed
or static IP address, per orm these
steps:
A.
Select Static IP as the
Connection Type in the Internet
Connection Settings area
o the
web page.

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
7
B.
Enter the IP address in the
Static IP ield.
C.
Enter the subnet mask in the
NetMask ield.
D.
Enter the de ault gateway
address in the Gateway ield.
E.
Enter the DNS server
address(es) in the Primary and
(optional) Secundary DNS ield.
F.
Select the Submit All Changes
button to save the settings.
3. PPPoE Configuration:
I the ISP (DSL Provider) connects
you via PPPoE or i you are required
to enter a user name and password
to connect to the Internet per orm
these steps:
A. Select P
PPoE as the Connection
Type in the Internet Connection
Settings area o the web page.
B. B.
Enter the user name in the
PPPoE Login Name ield.
C.
Enter the password in the PPPoE
Login Password ield.
D.
Select the Submit All Changes
button to save the settings.
4. MAC Address Clone
Configuration:
I the ISP
requires that a speci ic PC
MAC address be used with their
service to connect to the Internet
per orm these steps:
A.
In the MAC Clone Settings
section o the web page, set
Enable MAC Clone te YES.
B. Enter the
MAC Address o the PC
in the MAC Address Spoo ing
ield.
C.
Select the Submit All Changes
button to save the setting.

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
Router Configuration Parameters
WAN Setup
Internet Conne tion Settings:
The SPA-2100 supports three types o Internet connections: DHCP, Static IP and PPPoE (PPP
over Ethernet).
Stati IP Settings:
Note: These settings only take e ect i Internet Connection Type is “Static IP”.
PPPoE Settings:
Note: These settings only take e ect i Internet Connect Type is “PPPOE”.
8
Parameter Name Des ription Type Default
Connection Type Select the type o your Internet
Connection. Options: DHCP/Static
IP/PPPOE.
Choice DHCP
Parameter Name Des ription Type Default
Static IP IP address used by the SPA-2100
when Internet Connection Type is
“Static IP”.
IP 0.0.0.0
Netmask Network mask used by the SPA-
2100 when Internet Connection
Type is “Static IP”.
IP 0.0.0.0
Gateway Gateway used by the SPA-2100
when Internet Connection Type is
“Static IP”.
IP 0.0.0.0
Parameter Name Des ription Type Default
PPPoE Login Name PPPoE login name (provided by
your Internet Service Provider).
Str128
PPPoE Login Password Corresponding PPPoE login
password (provided by your
Internet Service Provider).
Str128
PPPoE Service Name PPPoE Service Name (optional,
check with your Internet service
provider)
Str128

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
MAC Clone Settings:
Remote Management:
Remote Management allows you to con igure the SPA-2100 through the web inter ace via the
WAN port. By de ault, this unction is disabled and must be enabled by the Administrator o
the SPA-2100.
QoS Settings:
QoS enables the prioritization o voice communication when upload tra ic causes the
available upstream bandwidth to become congested.
VLAN Settings:
VLAN (801.Q) settings enable you to use SPA-2100 in the Virtual LAN environment.
9
Parameter Name Des ription Type Default
Enable MAC Clone Enable/Disable MAC Cloning Bool No
Cloned MAC Address The MAC address to be cloned MACAddr
Parameter Name Des ription Type Default
Enable WAN Web
Server
Enable/Disable WAN port web
server
Bool No
WAN Web Server Port WAN port web server port Uns16 80
Parameter Name Des ription Type Default
QOS Qdisc Select QoS method. “NONE” means
no QoS is used “CBQ” and “TBF”
are two di erent methods to do
QoS
Choice NONE
Maximum Uplink Speed
The total maximum upload speed o
your Internet connection
Uns16 128Kb/ps
Parameter Name Des ription Type Default
Enable VLAN Enable/Disable VLAN Bool No
VLAN ID The VLAN ID used by the SPA-2100
Valid values are 1 to 7.
Uns8 1

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
LAN Setup
LAN Network Settings:
Stati DHCP Lease Settings:
Static DHCP Leases enable the SPA-2100 to always assign the same IP address to speci ied
device. There are a total o ten entries. Each entry has the same three properties described
below:
Important Note:
The assigned “Host IP Address” CANNOT be in the con igured IP address range used or the
DHCP clients. See: “DHCP Client Starting IP address” and “Number o Client IP Address” in
LAN Network Settings above.
10
Parameter Name Des ription Type Default
LAN IP Address The IP address used by the LAN (PC)
port
IP 192.168.0.1
LAN IP Mask The network mask used by the LAN
port
Choice 255.255.255.0
Enable DHCP
Server
Enable/Disable the embedded DHCP
server running on the SPA-2100
Bool yes
DHCP Lease
Time
The DHCP lease time used by the SPA-
2100 to distribute IP address to the
clients
Uns16 24 hours
DHCP Client
Starting IP
address
The starting IP address o the DHCP
client IP address range
IP 192.168.0.2
Number o Client
IP Address
Maximum number o IP addresses that
can be distributed to clients
Uns8 50
Parameter Name Des ription Type Default
Enable Enable/Disable Bool No
Host MAC Address The MAC address o the speci ied
device
MACAddr
Host IP Address The IP address assigned to the
speci ied device
IP

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
Appli ation
Port Forwarding Settings:
There are twenty (20) port orwarding entries. Each entry can de ine a port range to be
orwarded to a server host. Each port orwarding entry has six properties described below:
DMZ Settings:
System Reserved Ports Range:
Note:
The “Starting Port” has a ixed base o 10000. For example, by de ault it is set to 50000, thus
the system reserved ports range will be [60000, 60256].
System Reserved Ports Range de ines the random TCP/UDP ports used by application
running on the SPA-2100. These ports and other system reserved ports CANNOT
be used by Port Forwarding and/or DMZ servi e.
For example, 5060 is reserved i line 1 o the SPA-2100 is enabled.
11
Parameter Name Des ription Type Default
Enable
Enable/Disable this port orwarding
entry
Bool No
Service Name Name used to identi y this entry
(optional)
Str128
Starting Port The starting port o the orwarded port
range
Uns16
Ending Port The ending port o the orwarded port
range
Uns16
Protocol T
he protocol (TCP/UDP/Both) applied in
the port orwarding
Choice TCP
Server IP Address The target host that the tra ic is
orwarded
IP 0
Parameter Name Des ription Type Default
Enable DMZ Enable/Disable DMZ settings Bool No
DMZ Host IP The DMZ server IP address IP 0
Parameter Name Des ription Type Default
Starting Port
The starting port o the system
reserved port range
Uns16 50000
Num o Ports
Reserved
Total ports reserved by the system Choice 256

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
IVR Interfa e
IVR A tion IVR
Menu
Parameter(s) Notes
Activate IVR Menu **** None Ignore SIT or other tones until
you hear, “Sipura
con iguration menu. Please
enter option ollowed by the
pound key or hang-up to
exit.”
Check WAN IP Address 110 None IVR will announce the IP
address o the WAN port
Check WAN Network Mask 120 None IVR will announce the network
mask o the WAN port
Check WAN Gateway 130 None IVR will announce the
gateway o the WAN port
Check MAC Address 140 None IVR will announce MAC
address o the SPA-2100
Check Firmware Version 150 None IVR will announce the
irmware version running on
SPA-2100
Check Primary DNS
Server IP Address
160 None IVR will announce the primary
DNS server IP address
Check WAN Port Web
Server Port
170 None IVR will announce the WAN
port web server port
Check LAN IP Address 210 None IVR will announce the IP
address o the LAN port
Check WAN Internet
Connection Type
100 None IVR will announce the WAN
Internet Connection Type
Set WAN Internet
Connection Type (see
“Wan Setup” -> “Internet
Connection Settings”)
101 Enter 0 to use DHCP
Enter 1 to use Static IP
Enter 3 to use PPPoE
Set Static IP address (WAN
Port)
111 Enter IP address using
numbers on the telephone
keypad. Use the * (star) key
when enter a decimal point
WAN Internet Connection
Type must be set to “Static
IP”, otherwise you will hear
“Invalid Option” when you try
to use this option
Set WAN Network Mask 121 Enter network mask using
numbers on the telephone
keypad. Use the * (star) key
when enter a decimal point
WAN Internet Connection
Type must be set to “Static
IP”, otherwise you will hear
“Invalid Option” when you try
to use this option
Set WAN Gateway 131 Enter IP address using
numbers on the telephone
keypad. Use the * (star) key
when entering a decimal
point.
WAN Internet Connection
Type must be set to “Static
IP”, otherwise you will hear
“Invalid Option” when you try
to use this option
12

Sipura SPA-2100 ATA User Manual csdata the VoIP Company
csdata brasil Ltda. / Tel. +55 81 3422 1714 / Fax. +55 81 3422 1984 / VoIP 2031
SPA-2100 Voi e Servi e Configuration and Settings
Please see the SPA ATA User Guide or in ormation about the voice service con iguration and
settings. The SPA ATA User Guide can be ound on the Sipura Technology web site.
http://www.sipura.com/support
Support
Service providers may contact csdata brasil Ltda. and receive direct support by sending email
to suporte@linhagratuita.com.br
Thank you or your support.
csdata brasil Ltda.
13
Set Primary DNS Server IP
Address
161 Enter IP address using
numbers on the telephone
keypad. Use the * (star) key
when entering a decimal
point.
Enable/Disable Wan Port
Web Server
7932 Enter 1 to enable
Enter 0 to disable
Reboot the SPA-2100 7326
68
None The unit will reboot a ter you
hang-up the phone
Factory Reset 7373
8
Enter 1 to con irm
Enter * (star) to cancel
SPA will prompt or con irm, i
you con irmed to do actory
reset, you will hear “Option
Success ul,” hangup, Unit will
reboot and all con iguration
parameters will be reset to
actory de ault values
User Factory Reset 8777
78
Enter 1 to con irm
Enter * (start) to cancel
SPA will prompt or con irm, i
you con irmed to do user
actory reset, you will hear
“Option Success ul,” hangup,
Unit will reboot and all user
writable parameters will be
reset to actory de ault values
Other manuals for SPA-2100
3
Table of contents