sirea MicroARM-A4 User manual

MicroARM-A4
Programmable Logic Controller
User Manual
Date Version Modification
30/04/12 1 Initial version
03/08/12 2 Adding COM2 RS232
23/03/18 3 ranslated version, sections 5 to 9 added, new layout following SIREA’s graphic chart
1

MicroARM-A4
Programmable Logic Controller
Table of content
1. Introduction ................................................................................ 3
2. Characteristics ............................................................................ 3
2.1 Presentation of the board.................................................................................3
2.2 LED meanings.....................................................................................................4
2.3 Mechanical dimension.......................................................................................4
3. Connections ............................................................................... 4
3.1 Digital..................................................................................................................4
3.1.1 Digital input.........................................................................................................4
3.1.2 Digital output with PNP transistor......................................................................5
3.1.3 Digital output with relay......................................................................................5
3.2 Analog.................................................................................................................5
3.2.1 Analog input........................................................................................................5
3.2.2 Analog output.....................................................................................................6
3.3 Communication port..........................................................................................6
3.3.1 COM0 RS232 and COM2 RS232........................................................................6
3.3.2 COM1 RS485.......................................................................................................6
3.4 Power supply......................................................................................................7
4. Loading an application ............................................................... 7
5. Safety and warnings .................................................................... 7
6. rotection device ........................................................................ 8
7. Elimination ................................................................................. 8
8. Cleaning ..................................................................................... 8
9. Technical features ....................................................................... 8
2

MicroARM-A4
Programmable Logic Controller
1. Introduction
his manual describes the specifics of the MicroARM-A4.
For information common to programming, see the "MicroLADDER manual". o visualize
better the corresponding addresses in MicroLADDER, they appear in color, on the sides of
the diagrams.
Do not declare the digital output if the analog outputs are to be used.
2. Characteristics
2.1 Presentation of the board
➔ARM7 LPC2368 Processor
➔512Ko Flash (to save the monitor and the application) and 32Ko RAM
3

MicroARM-A4
Programmable Logic Controller
➔2 RS232 ports (COM 0 and COM2) on the same SubD 9 points connector for
loading or free of use
➔1 RS485 port (COM1) for loading or free of use
➔1 R C (Real ime clock) on bus I2C with backup battery (optional)
➔1 EEPROM 16 Ko on bus I2C (to backup variables)
➔1 SRAM 32Ko on bus I2C (to backup variables) (optional)
➔8 inputs can be used as digital or analog (0-20mA or 0-10V)
➔4 outputs with transistor can be used as digital or analog (0-10V)
➔3 digital outputs with transistor
➔1 digital output with relay
➔1 reset push-button (inter 2) (located at the left of RS232 connector, jumper side)
➔1 push-button to change the program (inter 1) (located on the right of RS232
connector, relay side)
2.2 LED meanings
L1 : Working state of the Programmable Logic Controller (PLC)
L2 : Presence 3,3 volts tension
L3 : Presence tension supply
See red circles on drawing 2.1.
2.3 Mechanical dimension
3. Connections
3.1 Digital
3.1.1 Digital input
Value range from 0 to 1.
123456789
%I100 %I101 %I102 %I103 %I104 %I105 %I106 %I107 +Alim
4
110 mm
119 mm 51 mm
%I104
%I106
%I105
%I107
%I102 %I103
%I100 %I101
Jumpers configured in voltage
1234 5678 9

MicroARM-A4
Programmable Logic Controller
3.1.2 Digital output with PNP transistor
Value range from 0 to 1.
1 2 3 4 5 6 7 8 9 10 11 12 13
Commun
0V
Commun
0V
%Q100 %Q101 %Q102 %Q103 Commun
0V
Commun
0V
%Q104 %Q105 %Q106 Commun
0V
Commun
0V
3.1.3 Digital output with relay
Value range from 0 to 1.
3.2 Analog
3.2.1 Analog input
Value range from 0 to 10000 if configured in voltage and 0 to 20000 if configured in current
1234567891011
%IW100 %IW101 %IW102 %IW103 Commun
0V
Commun
0V
%IW104 %IW105 %IW106 %IW107 Commun
0V
5
%IW104
%IW106
%IW105
%IW107
%IW102 %IW103
%IW100 %IW101
Jumpers configured in voltage
%IW104
%IW106
%IW105
%IW107
%IW102 %IW103
%IW100 %IW101
Jumpers configured in current
%Q107
1 2
3 4 5 6 7 8 9 10 11 12
13
1 2 3 4 5 6 7 8 9 10 11

MicroARM-A4
Programmable Logic Controller
3.2.2 Analog output
Value range from 0 to 10000. Do not declare the digital output
if the analog output must be used.
12345678910
Commun
0V
Commun
0V
%QW100 %QW101 %QW102 %QW103 Commun
0V
Commun
0V
Commun
0V
Commun
0V
3.3 Communication port
3.3.1 COM0 RS232 and COM2 RS232
Standard pin on DB9.
Pins on 7 and 8 are used for the COM2.
his communication port is located on DB9 connector.
1 NC 6 NC
2 RX0 7 X2
3 X0 8 RX2
4 NC 9 NC
5 GND 0V
3.3.2 COM1 RS485
6
B
A
9
1 2 3 4 5 6 7 8 10
1
6
5
9

MicroARM-A4
Programmable Logic Controller
3.4 Power supply
4. Loading an application
Since there is no SD card, the loading must be done by MicroControl.
Before the first load, on power-up, the PLC attempts to launch the application that does
not exist (default settings) and crashes.
o avoid blocking, press the PROG button in the first second after the power-on. his
forces the PLC to stay on the monitor. It is then possible to act with MicroControl.
5. Safety and warnings
If the device is not used as per these instructions, the safety of people and
equipment can be compromised. We disclaim any liability for any material
damage or due to improper handling or failure to comply with the safety
instructions.
he interventions on the devices must be made by staff who are competent to work on
electric installations.
Before all interventions, all power supplies must be switched off. he cutting devices on
the installation must be dimensioned and placed according to the standard U E C
15-100.
For all interventions on a device installed on an electric installation, the Personal Protective
Equipment (PPE) as defined by the safety regulations on the electric installations must be
carried by the worker.
In the event of a failure or malfunction, the device must not be opened and must be
returned to the factory.
Observe the following pictograms:
Attention.
On the product label this symbol means that the notice must be consulted.
In this manual, this symbol indicates important information.
Direct current.
7
0V
24V

MicroARM-A4
Programmable Logic Controller
his device is CE approved and complies with the national and European
guidelines.
6. rotection device
Quick fuse protections must be positioned on the 24 volt continuous start feeding the
PLC. hese fuses will be sized according to the number of devices set in series behind the
start.
7. Elimination
Old electronic devices are recyclables goods that should not be thrown into the
trash can. If the device reaches the end of its life, it should be eliminated in
accordance with the legal regulations in force to the recovery centres in your
municipality. Elimination in the household trashes is prohibited.
8. Cleaning
For cleaning, use a clean, dry, antistatic, lint-free cloth without corrosive products.
9. Technical features
Power supply 10 to 28 V
Maximum operating Altitude 2000 m
Maximum operating emperature 45 °celsius
Maximum Operating Humidity 70 %
8
Other sirea Controllers manuals
Popular Controllers manuals by other brands

Juniper
Juniper WLC Series Complete hardware guide

Rainbow Pool Products
Rainbow Pool Products CHEMIGEM DM52CHL manual

Argo
Argo IR Series Installation manual and operating instructions

Allen-Bradley
Allen-Bradley PowerFlex 750 Series Programming manual

ICT
ICT Protege GX quick start guide

maximal
maximal Maximal3D installation guide