GS241T-H02
Compound Carbon Dioxide Temperature and Humidity Alarm
Operating Instruction
1Product Overview
GS241T-H02 compound carbon dioxide temperature and humidity alarm, adopt high-precision NDIR
carbon dioxide sensor, digital temperature and humidity sensor chip, is used for detection of the indoor
environment of the carbon dioxide content, temperature and humidity and display in the screen, when they
tested the carbon dioxide, temperature or humidity is beyond the preset alarm value, the product will be in
the form of traffic lights remind users. Avoid excessive CO2 concentration to cause harm to human body,
protect the safety of life and property.
This product is suitable for CO2 concentration, temperature and humidity monitoring in ordinary houses,
offices, schools and other places. It is built with a 24-hour automatic calibration algorithm program, do not
need manual calibration.
2Product Features
High precision NDIR carbon dioxide sensor, detection accuracy ±(50ppm+5% reading value)
High precision ambient temperature detection, detection accuracy ±0.5 or 0.9
High precision ambient humidity detection, detection accuracy ±5% RH
With traffic light indicator, realize fast and intuitive abnormal reminder function
You can choose Celsius or Fahrenheit to display, according to different areas of use habits
Own display screen, easy to view
With light intensity detection function, automatically adjust the display brightness
With touch button, easy to operate
The backup battery life is more than 12 hours
It can be placed on the desktop or mounted on the wall
The service life of the product can reach 10 years
3Product Photographs
4Operating Instructions
This product has the function of CO2 concentration detection and alarm, as well as the function of
temperature and humidity detection and display.
LED panel displays information such as CO2 concentration, ambient temperature and humidity
4.1 Power supply and startup
At the same time, the product is equipped with externalAC power adapter for power supply and
built-in backup rechargeable polymer lithium battery, which can work for 12 hours afterAC power is
cut off, and remind users to charge when the battery is low voltage
The product is started when the AC power adapter is inserted or the backup power is switched
on. It takes 3 minutes to warm up after the product is started. WhenAC is powered, the traffic light
indicator window is always on, while when backup battery is powered, the traffic light indicator
window flashes. When the backup battery is low voltage. The traffic light indicates that every 4S will
be bright yellow.
4.2 CO2 detection and display
This product can detect and display the CO2 concentration of the surrounding environment and
give corresponding warning. The default warning value is 800ppm, and the default alarm value is
1500ppm. If users have more reasonable suggestions please discuss with us.
Good condition: When 800ppm, the warning window shows green color (See figure 3);
Normal condition: When 800ppm ~1500ppm, the warning window shows yellow (See figure 4);
Poor condition: when 1500ppm, the warning window will display red color (See figure 5).
figure 3 figure 4 figure 5
4.3 Temperature detection and display
This product can detect and display the ambient temperature, (the temperature measurement range
is -5 ~ 50 or 23 °F ~ 122 °F.
figure 6
4.4 Humidity detection and display
This product can detect the ambient humidity.
figure 7
(figure 1)(figure 2)
Number Function Number Function
1 6
CO2
2
Traffic light indicator
7
SET/AUTO
Button
3
Functional indicator light
8
TEST/HUSH
Button
4
Temperature
9
Power adapter socket
5
Humidity
Backup power switch
(Tab1)
1
2
3
4
567
≥
8
9
4.5 Touch button function
SET/AUTO
Short press -- manually select the display temperature, humidity, CO2, and automatically scroll display;
Long press -- Convert the temperature unit to / , press for 3 seconds in the temperature display
state;
TEST/HUSH: Short press
Long press - CO2 test alarm.
4.6 Environmental light detection function
When AC power supply is normal, CO2, temperature and humidity are in the normal range, if the
ambient brightness is very low (at night, indoor lights are all off), the brightness of the product's display
screen and indicator light will automatically decrease to reduce the impact on users' sleep. Normal
brightness is displayed when CO2 or temperature and humidity are detected abnormal.
4.7 Installation
This product recommends wall installation.
Method of wall installation
Select the appropriate installation location of the alarm to ensure that there are no wires or pipes
in the vicinity or within the walls.
Determine the position of the two fixing screws on the alarm panel, the center distance of the two
holes is 58mm, and drill the two diameters 5 mm depth of about 30~40mm hole;
Insert two expansion rubber plugs into the holes respectively in the installation package;
Screw the screws in the mounting package into the rubber plug and set aside about 3~5 mm;
Install the alarm as shown in figure 8.
figure 8
figure 9
5Product Technical Parameters
Working voltage DC5V (Power adapter 5V/1A)
CO2 measurement range 400 ~ 5000 PPM
CO2 measurement error range ±(50ppm+5% reading value) (Note 1 and Note 2)
Pressure dependence + 1.6 % reading per kPa deviation from normal pressure
CO2 measurement resolution and response
time 1 PPM ; T90 < 120s
Temperature range -5 ~ 50 or 23 ~ 122
Temperature measurement error range ±0.5 or 0.9
Temperature measurement resolution and
response time 0.1 / ; T90 < 120s
Humidity measurement range 0.0% ~ 99.9%RH
Humidity measurement error range ±5% RH
Humidity measurement resolution and response
time 0.1% ; T90 < 600s
Backup battery running time 12 Hours
Extreme Work environment Working temperature -5 ~ 50 , working humidity 0 ~ 90%RH(no
condensation)
Storage environment Storage temperature -10 ~ 60 , storage humidity 0 ~ 95%RH(no
condensation)
Product service life 10 years (End of product service life display "End")
Level of prevention and care IP40
Environmental protection standard RoHS
Overall dimensions 99mm*99mm*37mm
Product weight Net weight 268g
Note 1: In indoor air CO2 detection applications, the accuracy is measured after 24 hours of continuous
operation of the equipment.
Note 2: The nominal accuracy of the data at room temperature +25°C and atmospheric pressure 101.3kPa,
the device used for calibration and the gas have an uncertainty of ±1%.
6Matters Needing Attention
6.1 In the process of product use, due to transportation, installation and other factors, may cause NDIR
carbon dioxide sensor zero drift and detection accuracy reduction, the first use or change the use of
the environment, should let the product continue to work for more than 24 hours, automatically correct
the drift.
If CO2 concentration is obviously abnormal or above 1500PPM when it is used for the first time,
manual calibration can be adopted to quickly correct the drift. The method of manual calibration is as
follows: after the product is started, it is placed in a fresh outdoor environment for more than 5 minutes,
and the wire or metal wire is short-connected to the manual calibration port as shown below for 2
seconds and then released. The equipment will be manually calibrated to 400PPM in 6 seconds.
6.2 This product cannot be used in factories, warehouses and other industrial environments that may be
in high CO2 concentration for a long time. The CO2 detector used in industrial environments needs
regular manual calibration.
6.3 If the product is to be placed in a narrow space, the space should be well ventilated, especially the
two diffusion Windows should be in a well-ventilated position.
6.4 The product should be away from heat source, and avoid direct sunlight or other thermal radiation.
6.5 This product should not be used in the environment with high dust density for a long time.
6.6 Do not use the device in potentially explosive rooms.
6.7 Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and
labels legible condition.
6.8 Do not open the device in case it is damaged.
6.9 Clean the device with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing.
Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners, but only clean
water to moisten the cloth.
6.10 The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates
that this equipment must not be disposed of with the household waste at the end of its life. You will find
collection points for free return of waste electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local administration. The separate collection of
waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of
recovery of waste equipment as well as to prevent negative effects for the environment and human
health caused by the disposal of hazardous substances potentially contained in the equipment.
7Troubleshooting
Number Fault phenomenon Cause analysis, Solution
1
The device is not
displayed, the indicator
light is not on, and
there is no response to
the button operation
Controller is not powered
on Check the power supply
Equipment failure Contact the after-sales
2 The measurement of
CO2 concentration
value is not accurate
The 24-hour self-
calibration process is not
complete Power on for 24 hours
CO2 sensor failure Contact the after-sales
3 Intermittent device
voice low voltage
The backup battery
voltage of the device is
too low
ConnectAC power and turn
on the backup power switch
for charging
Free standing on table is also workable.
Method of free standing: (See figure 9)
Twist off the back cover, get adapter wire through the center hole of back cover,
plug in, twist back the cover. Put the detector on a horizontal desktop.

Other Siterwell Security System manuals

Siterwell GS828 User manual

Siterwell

Siterwell GS828 User manual

Siterwell GS816B User manual

Siterwell

Siterwell GS816B User manual

Siterwell GS811-A User manual

Siterwell

Siterwell GS811-A User manual

Siterwell GS412B User manual

Siterwell

Siterwell GS412B User manual

Siterwell SWM816A User manual

Siterwell

Siterwell SWM816A User manual

Siterwell GS869 User manual

Siterwell

Siterwell GS869 User manual

Popular Security System manuals by other brands

mcmurdo Fast find 200 user manual

mcmurdo

mcmurdo Fast find 200 user manual

SAFE Security Alarm System Operation manual

SAFE Security

SAFE Security Alarm System Operation manual

Le Las KLM 405 E User guide and installation manual

Le Las

Le Las KLM 405 E User guide and installation manual

Comelit Secur HUB Technical manual

Comelit

Comelit Secur HUB Technical manual

Risco Agility 4 Quick user guide

Risco

Risco Agility 4 Quick user guide

HORN LHD6001+ installation manual

HORN

HORN LHD6001+ installation manual

DAS VoiceNav Lite user manual

DAS

DAS VoiceNav Lite user manual

Express Controls EZMultiPli owner's manual

Express Controls

Express Controls EZMultiPli owner's manual

FHF ActiveLine GH5 manual

FHF

FHF ActiveLine GH5 manual

Protect Fog Cannon Important information for the user

Protect

Protect Fog Cannon Important information for the user

Ziton ZP755HAV-2 Installation sheet

Ziton

Ziton ZP755HAV-2 Installation sheet

Stitch 35383 user manual

Stitch

Stitch 35383 user manual

Signet QV-3020 user manual

Signet

Signet QV-3020 user manual

Verint Nextiva S4200-BZ user guide

Verint

Verint Nextiva S4200-BZ user guide

Kidde 900-CUAR-VCA user guide

Kidde

Kidde 900-CUAR-VCA user guide

Risco WisDom Installation and programming manual

Risco

Risco WisDom Installation and programming manual

Inner Range Integriti Prisma Keypad user manual

Inner Range

Inner Range Integriti Prisma Keypad user manual

Ganz H.264 Network Camera Series user manual

Ganz

Ganz H.264 Network Camera Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.