Number
Name
1 Buzzer sound hole
2 Button
3 Alarm indicator(Red)
4 Fault indicator(Yellow)
5 Power Indicator(Green)
1.
Overview
CO Alarm (SWM816A) adopts electrochemical sensors, is used to detect
carbon monoxide gas generated when fuels such as coal are not fully burned, and
inform users in time to avoid the occurrence of poisoning caused by the
accumulation of carbon monoxide.
If a CO Alarm which is added to BASE intelligent security system (gateway) has
detected carbon monoxide, its own will be issued a high-decibel alarm tone, the
intelligent gateway will also send out alarm immediately and push this message to a
smart terminal such as a smart phone in time.
If a CO Alarm which is added to ganged alarm system has detected carbon
monoxide,its own will be issued a high-decibel alarm tone and the alarm devices in
the same system will also send out alarm.
Notice! Information in this manual may change according to BASE application
system updates.
Please check the latest version from our website www.safewith.me
2.
Features
• Can use alone.
• Can be added to the BASE intelligent security system.
• Can be added to the ganged alarm system.
• Alarm tone issued by the alarm is 85 dB at least.
• Low standby current, long battery life.
• Two-way wireless communication, convenient to use.
• MC-DE3 wireless communication protocol, safe, reliable, convenient.
• Wireless distance is more than 100 meters.
• Easy to join BASE intelligent security system.
3.
Illustration

SWM816A User Manual V2.0
3 / 10
4.
Installation instruction
4.1 Installation location
• Recommended to locate 1~3 meter away from fuel burning appliances.
• Install in a bedroom or hallway located close to the sleeping area. Take special care
to verify the alarm can be heard in sleeping areas
• Placing at eye level allows you for optimum monitoring of the red and green indicator.
• Insure that all vents of the unit are unobstructed.
• Place out of the reach of children. Under no circumstance should children be allowed
to handle the CO alarm.
• CO alarm is recommended to be installed on each level of a multilevel home.
4.2 Inadmissible installation location
• Do not install in dead air spaces such as peaks of vaulted ceilings, or gabled roofs.
• Do not install in turbulent air from ceiling fans.
• Do not place near fresh air vents or close to doors and windows.
• Keep the CO alarm away from excessively dusty, dirty, or greasy areas such as
kitchens, garages and furnace rooms.
• Do not place behind curtains or furniture.
• Do not place near metal objects, otherwise it will affect the distance of wireless signal
transmission.
4.3 Installation method
Figure 3 Installation diagram
• Select a suitable installation location and ensure that no hidden objects such as
wires or water pipes in the wall.
• Drill two holes of 5mm in diameter in the mounting position referring to the screw
holes spacing on the bracket, see Figure 1.
• Plug the 2 plastic plugs in the kit into the hole.
• Fix the bracket to the wall with 2 screws in the kit, taking care to tighten the screws.
• Connect the alarm on the bracket.

SWM816A User Manual V2.0
4 / 10
5.
Operation instruction
5.1 Adding to BASE smart home ecosystem
It needs the cooperation of SWM188A (gateway) to be added to the BASE
intelligent security system, please refer to the 'BASE User Guide' for details.
Step 1 Step 2
Press the button of heat
alarm 3 times quickly.
Step 3
5.2 Add to ganged alarm system
It needs the cooperation of other alarms to be added to the interconnected BASE alarm
system, please refer to the 'Interconnected alarm system Quick Start'.

SWM816A User Manual V2.0
5 / 10
CO Alarm as a host device, press the button of CO Alarm 3 times quickly. Wait
for the indicator and then press the button of other devices 3 times quickly and
wait until the buzzer of host sends a 'beep' sound which means completed.
CO Alarm as a peripheral, press the buttons of other alarms (hosts) 3 times, the
indicator will be on. Press the buttons of CO Alarm 3 times quickly and wait until
the indicator of the host flashes 10 times or the buzzer sends out a 'beep' sound.
5.3 Test the alarm
There are two ways to test the alarm.
Hold on the button for about 5 seconds.
Click a test button of the alarm once in the APP (The alarm needs to be added
to the gateway).
Note!
Do not use flame to test the alarm, or the device may go broke and cannot be
repaired.
Due to the alarm tone issued by the alarm is 85 dB at least, so keep a bit
distance from the alarm.
In order to ensure the normal operation of the alarm, test needs to be conducted
once a week.
5.4 Alarm mute
If the safety of the area has been ensured when after alarm, you can press the
button to make a brief silence in order to avoid noise. Quiet time is about 10 minutes.

SWM816A User Manual V2.0
6 / 10
5.5 Alarm disposal
Once carbon monoxide poisoning occurs, it is very dangerous. If the carbon
monoxide alarm sends out an alarm, the following actions are recommended in the
following order.
1) Stay calm and open all doors and windows for ventilation. Stop using all fuel
burning equipment, if possible, make sure they are all off.
2) If the alarm continues to be activated, please leave the place. Leave the doors
and windows open and re-enter only when the alarm stops. If it is a multi-story
dwelling, ensure that all households are aware of the risks.
3) Anyone who suffers from carbon monoxide poisoning needs medical help.
4) Call the relevant repair or maintenance agency and ask professionals to
troubleshoot and correct carbon monoxide emission sources. Unless the warning
is clearly false, do not use the suspected fuel burning equipment.
5.6 Status Description
Green indicator flashes every 3 seconds (duration about
30s) while the alarm has just been attached to the battery:
Preheat -status.
Green indicator flashes every 32 seconds: Normal status.
Red indicator flashes 4 times every 5 seconds and buzzer
sends out 'beep' sound 4 times in a row: Alarm status.
Pressing the button once, red indicator flashes 4 times
every 5 seconds and buzzer sends out 'bi' sound 4
times
in a row, repeat twice:
Test status.
Yellow light flashes once every 30 seconds and the buzzer
sends out 'beep' sound: Fault status
Yellow light flashes 3 times every 30 seconds and the
buzzer sounds 3 times in a row: End of product life.
Pressing the button while alarming, the alarm will be silent
for about 5 minutes and the red indicator flashes: Silence status.

SWM816A User Manual V2.0
7 / 10
6.
Technical Specifications
Power input
DC3V(AA×2)
Standby current
≤50μA
Trigger current
≤20mA
Frequency
868MHz
Wireless distance
≥100 meters @in an open air
Executive standard
EN 50291-1:2010+A1:2012 standard
Alarm concentration
60~90mins@50PPM
10~40mins@100PPM
<3mins@300PPM
Alarm volume
≥85dB@3m
Silence time
About 5 minutes
Environment
-10~40
℃
, ≤95%RH Non-condensate
Safety standard
CE
Environmental
standards
RoHS
Size
95×95×34mm

SWM816A User Manual V2.0
8 / 10
7.
Troubleshooting
Number
Problems Reasons Solutions
1
Alarming while detecting
CO, but the status in
APP does not change.
Alarm doesn't connect to
BASE.
Refer to section 5.1.
Gateway doesn’t
connect to the Wi-Fi
network.
Check Wi-Fi or
reconfigure the
network.
Smart phone doesn’t
connect to the Wi-Fi
network.
Connect the Wi-Fi
and reconfigure the
network.
Distance between alarm
and gateway is too large.
Reinstall according
to the
recommended
installation location.
2
When the area has
carbon monoxide, the
alarm responds very
slowly
The installation location
is not suitable.
3
Not alarm while carbon
monoxide is detected.
Battery exhausted.
Replace battery.
4
Will not alarm by
pressing the test button.
5
Yellow indicator flashes
twice every 30 seconds
Low battery power.

SWM816A User Manual V2.0
9 / 10
and the buzzer beeps 2
sound

SWM816A User Manual V2.0
10 / 10
Statement
The information in the User's Manual is absolutely correct at the time of publication,
however we are not responsible for the application of this document. The application
mentioned in this document is for illustration purposes only. We do not guarantee or
represent that these applications without further modifications are appropriate and that
we also have the right to modify the product without any notice. For the latest
information, please refer to our website http://www.china-siter.com。
SITERWELL
ELECTRONICS CO.,LIMITED
Address: No.666 Qingfeng Road, Jiangbei District,
Ningbo, Zhejiang
Phone: 0086-574-87729576
Postcode:
315000
Web:
Importer:
www.china-siter.com
Suomen Turvakauppa Oy, Kaarina,
Finland.
Table of contents
Other Siterwell Security System manuals