Skold SCBA Phantom NFPA 2002 User manual


HUD INSTRUCTIONS
FOR SCBA Phantöm NFPA 2002
FIRST PART: Outline
Wireless Pressure Head-Up Display Device (Names HUD) is an indicator, it displays the pressure
change inside the cylinder, by wireless matching and then receiving the signal from the pressu-
re sensor controller.
HUD supplies a visual system for monitoring the air volume inside the cylinder. The HUD device
is installed inside the face mask, it can be observed by peripheral vision. It can indicate the
change in air volume when it is at 10Mpa, 10Mpa-6Mpa and below 6Mpa and alarm. Please
evacuate the danger zone before the gas using up.
SECOND PART: Introduction to the System
Main Feature
Consistent with the public safety industry standard positive pressure air respirator GA 124-2013
fire requirements comply with the safety certification Ex ia II CT3 Ga.
HUD
1.- Wireless connection, inspect the change in air pressure.
2.- Reduce the frequency of users to view pressure gauge.
3.- Small size and lightweight.
4.- Low power, low voltage alarm.
5.- Waterproof, dustproof, explosion-proof design.
Digital Display
1.- Wireless connected with HUD, the wireless communication distance is more than 15 meters.
2.- Three digital display pressure, more intuitive and quick.
3.- IP67-rated waterproof design, with the support of long spray environments.
4.- There are fall alarms and manual alarm function.
5.- LCD with backlight function, to ensure poor lighting conditions can also see pressure.
2

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
6.- When the air pressure is lower than alarm threshold, it will alarm.
7.- There are warning lights.
8.- Using a large capacity battery.
9.- Display the battery power, low voltage will voice prompts.
10.- There are directional light function.
HUD Appearance
Greenlight, Yellow light and Redlight are the indicator light of air pressure status.
1.- Air pressure state
Green light: The pressure is more than 10MPa.
Yellow light: The pressure is more than 6MPa and less than 10MPa.
Red light: The pressure is less than 6MPa, and at the same time, the shocking reminder will
start.
2.- When HUD is at the status of low power, the yellow light will be flash, and it can keep working
for more than 2 hours.
3.- Temperature Alarm
When the temperature is higher than 60 degree, the white light will be on.
4.- Bright adjustment
When the external light intensity change occurs, the light will automatically adjust air pressure.
System Components
>10MPa
10 > Pressure value > 6MPa
Pressure Value < 6MPa
Green light
Yellow light
Red light flash
Pressure Value Pressure Status Indication
3

1.- Main technical parameter
2- Main technical parameter
Content
Working pressure
Maximum working
electric current
Continuous
working time
Wireless
communication
distance
Pressure
indication range
Pressure
indication mode
Explosion levels
Protection class
Environment
Temperature
Relative humidity
Weight
Dimensions
Parameter
DC 3.6V
123*39*65mm (Length*Width*Height)
<50g
Working: -20°C ~ +60°C;
Storage: -10°C ~ +45°C
Working: 5% ~ 95%RH;
Storage: 5% ~ 95%RH
IP65
Exia II CT3 Ga
LED light: green, yellow, red
0-30Pa
<25mA 83.6v)
>90h
>1.5m
Content
Working pressure
Continuous
working time
Wireless
communication
distance
Pressure
indication range
Explosion levels
Protection class
Environment
Temperature
Relative humidity
Weight
Dimension
Parameter
3V
62*39*106mm
<200g
Working: -20°C ~ +60°C;
Storage: -10°C ~ +45°C
Working: 10% ~ 94%RH;
Storage: 20% ~ 80%RH
IP67
Ex ia II C T3 Ga (Intrinsically Safe )
>24h
>1.5m
0~40MPa
HUD
The HUD and pressure sensor controller must be used at
same time. The user checks the LED light on the HUD to
see the air pressure status. (HUD receives the air pressure
information from pressure sensor controller).
4

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
1.- ON/OFF
Open the device: After fixing the HUD press the red button and then release, all the indicators
light after 2 seconds, the device is on.
Close the device: The HUD will close automatically, after the HUD hasn´t received any air pressu-
re data in 180 minutes.
When the HUD is on, press the right behind button, blue status light flashes once half a second,
after 2 times flashes, release and then all lights are off, the device is closed.
2.- Method of Matching
When it is the first time to use HUD, it must be matched with pressure sensor controller for one
time.
The matching is as follow. Within the distance of 15 meters, press the matching key of pressure
sensor controller and HUD matching key, the blue light on the HUD flashes, after the blue light is
off, the air pressure indicator lights is on, it shows the matching is succesful. Then release the
button, HUD is in the status of closing, it must be reopened when the user wants to use it.
Notice:
1.- When matching the devices, if there are many pressure sensor controller are sending data,
the lead time for matching will be longer.
2.- The matched HUD, if the user wants to match again, the HUD won´t show itsucceeds in
matching, but it will display the air pressure state directly.
3.- Replacing the battery.
When the battery is in low power, the yellow light will flash, HUD can still work for more than 2
hrs, remove the battery, replace the specified type of special batteries.
Battery type: CR123A
Digital Display
1.- ON/OFF
Open the device: In the status of off, press the left button three seconds, LCD
indicator light release the button, the boot was successful.
Close the device: Under the power-on state, long press the left button over
3 seconds. LCD off, release the button of successfully.
Digital/Analog Manometer
5

2.- Pressure Display
There are 3 digits on the LCD screen shows the air pressure, it shows 0-30MPs. Under normal
operating conditions, the pressure refreshed every two seconds.
3.- Backlighting, field temperature, and residual gas usage time switch.
Press the right button, lit the backlight display, it will display the air pressure, press the right
button again display the scene temperature when the backlight is on, and it also can display the
site temperature. Press the button the third time, it will show the rest usage time when it is light.
4.- Power display and tips function
There is an icon of show battery volume in the right comer of the LCD screen, total 4 tables. When
it is full, means the battery is more than 75% two tables means it is more than 50% but less than
75% one table means it is more than 25% but less than 10% the digital display will have a sound of
less pressure and reminding to change the battery, but it can kept using for about 2 hours after
reminding.
5.- Pre-alarm, strong alarm and manual alarm
When manometer is still for 30 seconds, it will have the sound of choppy alarm and while light
prompt, shake the equipment can cancel this situation.
6.- Low pressure alarm
When air pressure value is less than 6MPa, the alarm light will flash, and the buzzer will call, the
sound is more than 90db.
7.- Low battery alarm
When the battery remaining 20% the alarm light will flash to remind of changing.
8.- Method of matching the equipment
The radio receiving apparatus is HUD. Within the distance of 1.5m, press the right button, at the
same time, press the matching button of the HUD. When there is a flash light on the HUD, it
shows the matching is succeeded, and it will shows the air pressure value. Then it is ok to release
the HUD and pressure sensor controller button.
9.- Wireless transmission function
Under the power-on state. The pressure sensor controller will send the air pressure data 2
seconds one time, at the same time, the Azimuth indicator will flash shortly.
10.- Replace the battery
When the indicator shows the battery is not sufficient, please replace the battery, with a special
screwdriver to unscrew the battery compartment cover screws, open the cover, remove the
battery, follow the prompts to the battery positive and negative direction to place the new
battery.
Note: Don´t remove and replace the battery in an explosive environment. Replace the batteries must
be using the specified model, or it may damage the wireless pressure sensing controller. Battery
type: CR21
6

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
HUD
The HUD is installed inside the facemask, install it and fix it then can use directly.
Digital Display
After interface with hog-pressure pipe connected, plugged in fixed pin stuck interface, the fixed
pin bracket securely installed before use.
THIRD PART: Cautions in use
1.- When using and transporting, try to avoid falling and impact.
2.- Don´t disassemble the battery or replace the battery in explosive.
3.- When replacing the battery, it must be to use the specified type of battery.
Operation Manual of Communication Gas Mask
1.- General specifications.
1.0 Weight: 260g.
1.1 Speaker: 8 ohms.
1.2 Degree of protection: IP66-IP67
1.3 Working temperature: -25 to 60
1.4 Size of outer casing: 165’76’85 cm
1.5 PC and silicone.
2.- Working area
2.0 It could filter different harmful gases according to the type of filters. Widely used in chemical,
firefighting, warehouse, industrial had harmful enviroment.
2.1 Protective our face and eyes in harmful environment.
2.2 Used in military, police station, hospital, etc.
2.3 Protection of our breathing system.
3.- Application description
3.0 Put the battery on the right place, then check the speaker and headphone, make sure there
ir no damage on full face mask.
3.1 Put the filter on face mask, try to breathe.
3.2 Check it you could breathe and speak normally, and let other people listen to your speaking.
4.- Warning
4.0 Please check if the microphone ir tightened on mask after wearing.
4.1 Make sure the power is on when working.
4.2 Close the power and take the battery out when not working.
5.- Components introduction
5.0 Full face mask.
5.1 Power.
5.2 Loudspeaker.
5.3 Volume adjustment.
5.4 Put filter.
5.5 Connect walkie-talkie.
5.6 Battery compartment.
5.7 Headset
7

Mascarilla completa
Encendido/Apagado
Auriculares
Compartimiento de
la batería
Conectar walkie-talkie
Colocar filtro
Ajuste de volumen
Altavoz
8

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
WARNING
THE APPLIANCE MUST NOT BE USED UNTIL THE FOLLOWING TEST HAVE BEEN COMPLETED.
ANDY DISCREPANCY NOTED DURING THE PRE-USE AND INSPECTION CHECK SHOULD ONLY BE
CORRECTED BY AN AUTHORIZED PERSONNEL BEFORE BEGINNING TO USE THE APPLIANCE.
Manual SCBA SKÖLD PHANTÖM
Certification CE: EN 137:2006 /Equivalent NFPA 1997
Models:
SCBA-P30FC (30 minutes carbon fiber cylinder).
SCBA-P60FC (60 minutes carbon fiber cylinder)
SCBA-P120FC (2 cylinders of 60 minutes carbon fiber cylinder).
IMPORTANT POINTS: PLEASE READ CAREFULLY IF NOT USED AND KEEP
APPROPRIATE THIS PRODUCT MAY RESULT IN INJURY OR DEATH.
The Phantöm’s pneumatic system is designed to be simple to use and easy to maintain and will
operate for many years if given proper maintenance and cleaning. The care and use instructions
given in this manual should be read, understood and follower carefully before using the applian-
ce. The procedures in this manual DO NOT make Sköld Safety responsible for any loss or injury
resulting from any actions arising out of the use of the same Spare parts and accesories are
avaliable from your Sköld Safety authorized dealer. Spare parts and accessories are available
from your Sköld Safety authorized dealer. Replacement parts from elsewhere will void NIOSH
approvals. No additional service not recommended in this manual is recommended. If a problem
persists, you should remove the service device, label it for repair and send it to an authorized
Sköld Safety Dealer or factory for evaluation and/or repair.
TRAINING
Sköld Safety strongly recommends that the training program be accordance with the Occupatio-
nal Safety and Head Programs. Training and service programs are available upon request. Please
contact Sköld Safety or your local distributors for further details.
NIOSH/OSHA WARNINGS
The following warnings have been given in accordance with accepted safety conventions
and/or NIOSH/OSHA cough requirements, and apply to the use of breathing apparatus in
general.
HEALTH LIMITATIONS: SCBA users must be medically certified prior to use. In addition, there
are physiological and psychological limitations that must be considered before using SCBA.
These include, but are not limited to:
- Emphysema
- Chronic obstructive pulmonary disease
- Bronchial asthma
- Evidence of pneumonia radiography
- Evidence of reduced lung function
- Coronary artery disease
- Severe or progressive hypertension
- Epilepsy ( great evil or small evil)
- Pernicious anemia
- Diabetes (insipid or mellitus)
- Respiratory distress when using SCBA
- Claustrophobia or anxiety when using SCBA
- Abnormal electrocardiogram (ECG) or pressure test results.
- Broken or perforated eardrum
9

WORKING TEMPERATURES
The Phantöm is approved for respiratory protection during entry or exit of oxygen deficient
atmospheres, gas atmospheres, and atmospheres of vapors at temperatures above -25°F. When
used below the freezing point, care must be taken to prevent moisture from entering the
demand and exhalation valves. This includes when the cylinders are being changed.
DURATION OF USE:
Although the Phantöm has been approved as a 30-minute, 45-minute, or 60-minute respirator,
varying work pace, physical condition and other factors can substantially reduce the actual
useful life of the unit.
SCBA LIMITATIONS:
The SCBA can only protect the respiratory system of the protection may be necessary to avoid
contamination through skin absorption. If it is suspected that these types of materials may be
present, an effective full-body protector of impermeable material should be used with the SCBA.
Sköl Safety and HazMat suits manufactures have available a HazMar Class A universal suit for the
Phantöm.
FACIAL HAIR:
Facial hair or any item that may interfere with the mask seal on the face on the operation of the
exhalation valve should not be allowed. This includes beads, sideburns, mustache, beads, head
covers, or anything that may interfere with proper mask sealing to the face. We also have a hood
available a hood available for users who have facial hair.
EYES DEVICES:
Do not wear glasses when the temple bars interfere with the sealing.
PRECAUTIONS AND LIMITATIONS
- Air line respirations may only be used when supplied with breathable air that meets the require-
ments of CGA G-71 Grade D or higher quality. Use only the pressure and hose length scales
specified in the User Instructions.
- Failure to properly maintains and use this product could result in injury or death.
- Approved respirators must be selected, adapted sued and maintained in cordance with OSHA
documents and other regulations that may apply.
- Never replace, modify, add or omit parts. You should only use the exact factory-specified
replacement parts. Do not mark the unit with inks or paints that may be flammable. A vibrating
artifact can be used to record on all parts except the viewfinders, on the cylinder.
- Refer to User Instructions and/or maintenance manuals for information on use and maintenan-
ce of these respirators.
- The User´s Critical or Special Instructions and/or specific limitations of use apply. See User
instructions before putting on the appliance.
CRITICAL INSTRUCTIONS SPECIAL FOT THE USER
- Approved for respiratory protection during entry to or exit from oxygen deficient atmospheres.
Atmospheres of gases and atmospheres of vapors at temperatures above -25°F.
- Approved only when the compressed gas container (cylinder) is loaded with air that complies
with the requirements G-71 Grade D or higher quality CGA gauges having a spray point of -65°F
or lower and a maximum level of particles of 5 ml/m 3 of air.
- The compressed gas vessel (cylinder) must meet applicable DOT specifications.
- When used as a combined device, only 20% of the service.
- This approval applies only when the device is being supplied with 6 to 300 feet of hose
at air pressures between 80 to 120 pounds per square inch of measurement from a
pro-Autonomous vision of air.
- If the supplied air fails, open the cylinder valve and exit to fresh air
immediately.
- Wear suitable skin protection when worn on gases and vapors
that Poisoning by absorption through the skin (eg hydrocyanic
acid gas).
10

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
The Sköld Safety Phantöm is a self-contained breathing apparatus, compressed air and circuit.
Which is approved by the National Institute of Occupational Safety and Health (NIOSH). The
positive pressure is maintained inside the mask during use, this providing the highest degree of
protection. Respiratory protection in unbreakable atmospheres avoiding any filtration to the
interior.
The Phantöm consists of several important components described in the following paragraphs.
1.1 MASK OR HOOD
The Sköld Safety Full Mask Assembly has an adjustable, four point head harness. The internal
part of the visor can be purchased with an anti-impeller coating. The standard mask seal has a
special contour to ensure proper fit. An internal nosepiece mask reduces all air flowing within the
mask and accumulating C02.
1.2 VALVE OF DEMAND
Compact Demand Valve provides high flow and is low profile to facilitate user movement. The
exhalation valve greatly reduces respiratory resistance, which allows a longer duration in the use
of the cylinder.
1.3 FIRST-STAGE PRESSURE REDUCER
The air exists the cylinder, passes through a sintered bronze filter in the handle assembly and
then proceeds to the first stage pressure reducer where it is reduced to approximately 125 psi.
The reducer is a simple type of piston the requires no adjustment and incorporates a self-seated
automated pressure relief valve to protect the lowering of the low pressure components. It is
made of high quality aluminium and is fimly mounted to the cylinder.
1.4 REMOVE CYLINDER PRESSURE INDICATOR AND SERVICE TERM TIME INDICA-
TOR.
The remote pressure gauge and whistle are mounted on the chest on the right shoulder strap.
The pressure gauge (water gauge) is waterproof with a neoprene protective coating and features
a luminous dial and indicator tips. The indicator shows the fraction of pressure remaining in the
cylinder. The primary Service End Time indicator is a whistle that is programmed to sound at
23%-27% cylinder pressure measurement according to NIOSH requirements. The frame and
harness assembly has a quick disconnect cylinder strap that can be used for a wide variety of
cylinders, and comes with an adjustable latch to ensure perfect cylinder installation. The
material of the harness is made of a special fire-resistant fabric design with shoulder buckles that
slide easily allowing the Phantöm SCBA to be quickly put on.
1.5 CYLINDER AND VALVE ASSEMBLY
A variety of cylinder types and different capacities can be accommodated in Phantöm models of
2216 psi and 4500 psi. (Please refer to the table in Section 17 for specifications). The cylinder valve
is a forged aluminum construction with a permanent layer ot Teflon. Each valve has a safety
feature and a double reading pressure gauge. The valve protection is provided by an elastome-
tric bumper.
PRECAUTIONS OF HANDLING
NEVER STAND OR CARRY THE UNIT BY THE MASK HOSE OR BY ASSEMBLING THE GAUGE IF THE
HOSE OILS OR IS DAMAGED IN ANY WAY, IT MUST BE REPLACED. CHECK FOR DAMAGE NEAR
METAL HOSE TERMINALS.
11

2.0 ROUTINE CHECKS
2.1 UNPACKED
Open the storage box. Observe the positioning of the various components to be able to repacka-
ge it again. Remove the SCBA from it case and place it on a clean, dry surface. Remove the mask
from the protective bag.
2.2 INVENTORY AND EXAM
Examine the physical condition of the unit and the appearance of all components. Make sure the
following important components are included:
- The Mask or Hood
- The Frame Assembly and Arnes.
- The Cylinder Assembly and Valve
- The options sorted with the SCBA
2.3 ROUTINE CHECKS INSPECTIONS
The following procedure should be used for daily and future inspections of the apparatus. A
SCBA that is not routinely used, but stored for emergency use only, should be inspected at least
once a month. All other appliances should be inspected after each use.
4500
4500
Carbon and
Epoxy
Carbon and
Epoxi
1287 liters
45 ft3
2516 liters
88 ft3
30 min
60 min
11.0 lbs.
19.2 lbs.
5.4 in
7.1 in
3 years
3 years
PSIG
Pressure Material Free air
capacity
Average duration
@40 lpm NIOSH
Valve and cylinder
weight Cylinder’s diameter Hydrostatic Interval
Cylinder
(L)
5
6
2
3
6.8
13.6
9
Cylinder
(Mpa)
30
30
30
30
30
30
30
Max air
volume of (L)
1500
1800
600
900
2040
4080
2700
Air supply
flow >L/min
300
300
300
300
300
300
300
Mpa)Warning
Pressure (MPa)
5~6
5~6
5~6
5~6
5~6
5~6
5~6
Use time
(min)
50
60
20
30
60
120
90
Package
Dimensions (cm)
77x30x48
77x30x48
77x30x48
77x30x48
77x30x48
77x30x48
77x30x48
Apparatus
weight (kg)
<12
<14
<4
<4.5
<8.5
<14.5
<11.5
12

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
2.3.1 Visually inspect the entire appliance for worm parts and damaged components.
2.3.2 The basic cylinder inspection shall include:
A ) Inspect the indicator for damage.
B ) Inspect for mechanical damage to the cylinder (cracks, dents) or signs of heat or chemical
damage. (Refer to “Guidance for visual inspection and re-qualification of reinforced fiber high
pressure cylinders” for all cylinders).
C ) Check that the date of the hydrostatic test on the cylinder is current.
D ) Check that the cylinder valve threads are not damaged.
E ) Check that the valve body is not bent. Check that the safety disk output is clean and free
debris.
If you notice any of the situations listed above, decompress the cylinder to a slight positive
pressure, label it and remove it from service.
3.0 PUTTING PROCEDURES AND SAFETY CHECKS
MAINTENANCE BY A TECHNICIAN AFTER EVERY 100 HOURS OF USE, OR AT LEAST ONE TIME
PER YEAR, THE COMPLETE SCBA SHOULD BE RELEASED AND LABELED TO GIVE A GENERAL
MAINTENANCE BY A TRAINED.
3.1 PROCEDURES FOR PUTTING IT
3.1.1 Place the Phantom on the floor with the cylinder valve facing the user.
3.1.2 Extend the shoulder straps. Make sure that all the belt, side and waist assemblies are fully
extended and that the belt buckle assembly is not connected.
3.1.3 Grasp the left shoulder strap with your left hand. Lift the Phantom towards your left shoulder.
Place your right arm through the right shoulder strap.
3.1.4 Pull the shoulder straps straight down to adjust the position of the unit on the back.
3.1.5 Attach the belt buckle and adjust the belt until you feel comfortable. Fold excess belt strap
and shoulder strap through the belt.
3.1.6 To put on the mask, adjust the mask by pulling the lower straps back first before adjusting
the top straps.
3.1.7 Open the cylinder valve slowly by turning it counterclockwise to a fully open position. The
whistle must be activated when the cylinder valve is opened. There must be air flowing out of the
Compact Demand Valve (CDV).
3.1.8 Connect the Compact Demand Valve (CDV). with the mask or hood.
13

3.19 Turn and pull out the Compact Demand Valve (CDV) to verify that it is secured in the mask or
hood.
3.1.10 With the Compact Demand valve (CDV) secured, the whistle be turned off.
3.1.11 If the Compact Demand Valve (CDV) is attached to the hood or mask before putting it on,
open the cylinder valve before putting on the mask or hood. Once the mask or hood is fitted,
verify that the Compact Demand Valve (CDV) is property secured by turning is slightly and
pulling it out.
IMPORTANT: DON´T OVERTIGHTEN THE MASK TO BE TIGHTENED TOO MUCH MAY CAUSEMODITY
OR DEFORMATION AND FILTRATION IN THE MASK.
3.2 ROUTINE CHECKS WARNING
THESE SAFETY CHECKS SHOULD BE BEFORE ENTERING A HAZARDOUS AREA FAILURE TO DO
THESE CHECKS CAN RESULT IN RESPIRATORY INJURY OR DEATH.
3.2.1 POSITIVE PRESSURE CHECK: With the cylinder valve open, breathe normally. Insert two
fingers between the mask and face. Lift slightly the face mask seal and make sure there is a good
air flow coming out, this showing that the pressure inside the mask is positive. Seal the mask
again and stop breathing for three seconds. There should be no sound of air leaking from the
Compact Demand Valve and no air flow should be felt in the area of the eye within the mask.
NOTE: A negative pressure check is not necessary because the Compact Demand Valve and
mask are designed to be a positive pressure mask or hood.
3.2.2 ALARM CHECK: Close the cylinder valve and continue to breathe normally. Watch for the
pressure gauge and listen for the whistle to activate as the indicator needle moves into the red
zone. Open cylinder valve fully.
3.2.3 Breathe deeply two or three times to ensure that you are getting enough air into the mask.
The mask should not move towards your face.
3.2.4 RE-CHECK THE CYLINDER PRESSURE: Check that the pressure indicator on the right shoul-
der harness is indicating that is above 7/8 (more than half between and FULL). Breathe normally
and proceed.
4.1 NORMAL USE
4.1.1 Monitor cylinder pressure during use to monitor supply of Air left and allow enough time to
get out.
4.1.2 The Service-End-of-Service (whistle alarm) indicator activates when approximately 25% of
the air supply remains. Exit when the alarm ir activated.
WARNING 25% OF A FULL CYLINDER MAY NOT BE SUFFICIENT IN SOME CIRCUMSTANCES TO
EXIT OUT OF A PIVS ATMOSPHERE.
An example would be to enter a long distance into a continuous PIVS (Immediate Danger to Life
or Health) atmosphere. In such situations, start exiting before the End-of-Service indicator
is activated.
WARNINGS: IF ANY OF THE CHECKS
LISTED PREVIOUSLY FAIL, DON´T FOLLOW
DISPOSE OF THE SERVICE UNIT LABEL,
AND RETURN IT TO BE REPAIRED BY AN
AUTHORIZED PERSONNEL.
14

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
4.1.3 INSTRUCTIONS FOR CHANGING CYLINDERS.
4.1.3.1 Make sure that the cylinder valve is closed an that all air has been emptied from the
pneumatic system.
4.1.3.2 Lift the latch to release the tension of the cylinder belt.
4.1.3.3 Disconnect the handle from the cylinder valve and remove the cylinder by sliding it up
through the cylinder strap.
4.1.3.4 Insert a new full cylinder by sliding it through the cylinder strap until the cylinder rests
against the button of the retainer.
4.1.3.5 Connect the handle to the cylinder valve and position the cylinder.
4.1.3.6 Close the latch lock.
4.1.4 ADJUSTING THE CYLINDER BELT
4.1.4.1 Make sure that the cylinder valve is closed and air from the pneumatic system has been
emptied.
4.1.4.2 Lift the latch to release the tension of the cylinder. belt.
4.1.4.3 To release the cylinder strap, slide the outer cylinder strap through the latch and pull the
inner strap to enlarge the opening. To lighten the cylinder strap, grasp the outer strap and pull up
and away from the catch. Place what is on the remote latch strap, around the cylinder. Do not
over lighten the belt.
4.1.4.4 Connect the handle to the cylinder valve and position the cylinder.
4.2 EMERGENCY OUTPUT INDICATORS
If any of the following occur, immediately leave:
A ) Exposure to electrical shock.
B ) High Temperaure Exposure
C ) Chatter or unusual noises in the SCBA.
E. )Water immersion(Note: In this situation the PHANTOM will continue to supply air to a depth of
at least 3 meters).
F ) That the SCBA has been exposed to a strong impact such as a fall.
G ) The airflow decreases to such an extent that the mask moves inwardly and towards the face
during inhalation.
Exposure to unknown gases or chemicals that require the use of a Class “A” suit.
5.0 PROCEDURES AFTER USE
IMPORTANT: DON´T REMOVE ANY EQUIPMENT UNTIL YOU HAVE COME OUT OF PIVS ATMOSPHE-
RE
5.1 TO REMOVE THE APPLIANCE
5.1.1 Fully undo the head harness straps. The air should flow freely from the mask. Breath deeply.
5.1.2 Close the cylinder valve by turning it fully in the direction (clockwise).
5.1.3 Remove the mask.
5.1.4 Remove the hood by placing both hands under the collar seal and lift the hood by the front.
5.1.6 Remove the appliance.
5.1.7 Remove the cylinder and label it to fill the cylinder.
5.1.8 Don´t place or store the appliance until has “Cleaning after use”.
6.0 CLEANING AFTER USE
6.1 CLEANING THE MASK
6.1.1 Disconnect the Compact Demand Valve from the mask or hood by removing
the safety catch and removing the Compact Demande Valve. Wash the mask or
hood in cool or lukewarm soapy water. Use mild soap, non-detergent
washing.
15

WARNING:
IF IT´S VERY LIKELY THAT THE APPLICANCE IS STORED AT TEMPERATURES UNDER THE
FREEZING POINT (32°F), THE MASK OR HOOD SHOULD BE COMPLETELY DRY.
6.2 SCBA CLEANING
6.21 Fully extend the shoulder and waist straps to an open position. Clean any dirt with a
medium-bristled brush or sponge and mild, non-detergent dishwashing soap. DON´T USE LEAF
OR NO COMPOUND WHICH CONTAINS CHLORINE BECAUSE THIS CAN QUICKLY DETERIORA-
TE THE MATERIAL.
CAUTION: IF IT IS NECESSARY TO CLEAN THE EXTERIOR PART OF THE COMPACT DEMAND
VALVE, YOU SHOULD BE CAREFUL TO ENSURE THAT NO WATER TRACES ARE LEFT AT THE
OPENING. CONNECT THE UNIT TO THE FULL AIR CYLINDER TO BLOW OUT WATER, ESPECIA-
LLY IF THE APPLIANCE WILL BE USED OR STORED AT TEMPERATURES BELOW FREEZING
POINT.
WARNING: DON´T IMMERSE PNEUMATIC COMPONENTS IN WATER. PERFORM ALL TESTS AND
MAINTENANCE WORK IN A CLEAN ENVIRONMENT.
7.0 SCBA STORAGE
7.1 STORAGE OF SCBA.
7.1.5 Verify that the shoulder and waist straps are fully extended.
7.11 Complete the routine checks and inspection procedures specified in the Section 2.3 of this
manual.
7.12 Check that the whole appliance is clean and dry.
7.13 Verify that the headgear mask and harness straps are fully extended. Connect the CDV in the
mask or hood and store it in this box, placed in a way that prevents it from deforming.
7.14 Place the entire appliance in the storage box or in a suitable place for storage so that it can
be easily used in case of an emergency.
7.15 SCBA MOUNTING. When storing the SCBA using brackets, check that the brackets are
secure and that there is no possibility that the SCBA or cylinder will scratch any sharp or pointed
objects.
8.0 USER MAINTENANCE
8.1 PROCEDURES FOR FILLING THE CYLINDER.
8.1.1 Basic cylinder inspection shall include:
A.- Inspect the indicator for damage.
B.- Inspect the cylinder for any mechanical damage (cracks, Dents) or have some heat or
chemical damage. (Refer to CGA C-6.2 ”Guide for inspection Visual and Recalification of
Reinforced Fiber High-Pressure Cylinders” for all cylinders.
C.- Check that the date of the hydrostatic test on the cylinder is current.
D.- Check that the cylinder valve threads are not damaged.
E.- Check that the valve body is not bent.
NOTE:
THE COMPACT DEMAND VALVE CAN BE
PUT IN WATER.
6.12 Rinse thoroughly in clean water,
allowing water to flow through the mask.
6.13 After rising, shake to get rid of excess
water. Dry with soft, clean cloth.
NOTE: Make sure that all head harness
straps are fully extended, ready for use.
16

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
F. Check that the safety disk outlet is clean and free of debris.
G. If you notice any of the situations listed above, decompress the cylinder to a slight positive pressure, label it
and remove it from service.
CAUTION
IF IT´S NECESSARY TO CLEAN THE EXTERIOR PART OF THE COMPACT DEMAND VALVE, CARE MUST BE
CAREFUL TO ENSURE THAT WATER TRAILS WERE NO LEFT AT OPENING OF THE CDV. CONNECT THE UNIT
TO THE FULL AIR CYLINDER TO BLOW THE WATER OUT, ESPECIALLY IF THE APPLIANCE IS GOING TO BE
USED OR STORED AT TEMPERATURES BELOW FREEZING POINT.
WARNING
DON´T IMMERSE PNEUMATIC COMPONENTS IN WATER. PERFORM ALL TEST AND MAINTENANCE WORKS
IN A CLEAN ENVIRONMENT.
NOTE: Cylinders that have been labeled for repair should always be stored empty with the cylinder valve
closed to prevent contamination or condensation inside the cylinder.
8.11 Before filling the cylinder, follow the basic inspection procedures specified.
8.12 Cylinder air shall meet or exceed CGA G-71 Grade D or higher standards.
8.13 Fill cylinder to maximum pressure (FULL). Wait at least 30 minutes for the cylinder to cool, then add more
air to fill it to room temperature. (Note: Pressure decreases when cylinder temperature drops).
9.0 PHANTÖM OPTIONS
9.1 AIR LINE
Line connection of
9.11 The Air Line Connection is located on the left belt of the belt. It is approved by Foster, Hansen, HK
Hansen and Schrader connectors. Foster, Hansen and Hansen HK connectors include locking devices.
9.12 When filled air is used, the user must ensure that the cylinder valve is closed. Failure to do so may
result in a reduction in cylinder life.
9.13 Air-line respirators may only be used when respirators are supplied with breathable air that meets
the requirements of CGA G-17 Grade D or higher quality.
9.14 When used as a combined appliance, only 20% service pressure can be used at the inlet.
9.15 This approval applies only when the apparatus is supplied with breathable air through 6 to 300 feet
with an air pressure measurement of 80 to 120 pounds per square inch or an autonomous air supply.
9.16 Follow procedures for putting equipment located in Section 3.0 and Safety Checks
in Section 329.17. Connect the Phantöm airline hose to the air supply hose. The
supplied air pressure should be 80 to 120 psi Close the cylinder valve and continue to breathe
normally. If the supply air is interrupted, open the cylinder valve fully disconnect the air line
hose, and exit to safe area. Note: Be careful not to pull the supplied air hose. This may
cause the hosppliede to become damager or to fail .
9.18.It is necessary to monitor the pressure of the supply air source while
operating with supplied air .
9.1.9 To change from supplied air to cylinder air, first open
the valve of the cylinder and then disconnect
the supplied air hose.
17

10.0 PHANTÖM GUARANTY
Skold Safety warrants to the original owner that the Phantom SCBA is free from defects in
materials and workmanship for a period of one year from the date of original purchase to the
Sköld Safety factories. Sköld Safety’s obligation under this guaranty is limited to replacing or
repairing at Sköld Safety’s option, any deective parts if returned to Sköld Safety in Monterrey
Mexico at factory authorized repair center, with shipping charges prepaid by the purchaser, and
which, once inspected by Sköld Safety, must prove defective under normal use and services.
This guaranty does not apply to malfunction of the equipment or to damages resulting from an
accident, alteration, misuse, or abuse of the equipment. In addition, this guaranty are mask
lenses, compressed air cylinders and parts worn for normal use. The decision of what constitu-
tes normal use should be taken only by Sköld Safety. To maintain this guaranty, the buyers must
perform maintenance and inspections as prescribed in the owner´s instruction manual which
will include an immediate replacement or repair of parts Detective parts and replacement parts
according to the maintenance program specified in the owner´s instruction manual. To validate
this guaranty, the Guaranty and Regristation Card supplied with the device MUST be completed
and returned to Sköld Safety AT THE END OF 30 DAYS from the day o which the purchase was
made. This guaranty is given in lieu of all other guarantees, express or implied, and all other
obligations and liabilities on the part of Sköld Safety. Sköld Safety does not assume or authorize
any other firm or person to assume, for the benefit of Sköld Safety, any liability in any way
associated with the sale of Sköld Safety products.
Problems
There ir a continual
air flow in face piece
whem it is worn.
No air or too high
resistance when
inhaling.
Mask leakage
There is an excessive
resistance when
exhaling
There is a seal leakage
between face and face mask.
There is a leakage in the outlet
of air supply valve.
There is an accident
breakdown of valve
diaphragm
The switch of cylinder valve is
not fully opened.
The medium pressure pipe is
blocked.
Air supply valve failure.
Pressure-reducing failure.
There is a poor sealing
between double seal ring and
the face mask fit well.
There is a leakage in the
junction of mask and air supply
valve.
There is a leakage between
mask and seal ring.
There diaphragm of exhalation
valve gets tacky.
Check and clean the components of exhalation valve.
Replace the mask components.
Remove the air supply valve from the mask and clean
the rubber seal ring and install it after adding silicone
grease oil. If there is still an obvious leakage, the
rubber seal ring should be replaced. After that, if the
leakage is still exists, please return it to the facttory to
repair.
Weaber seal the mask again to well adjust the
mask and the face.
Return it to the manufacturer to debug and repair.
Return it to the manufacturer to repair.
Fully open the switch of the cylinder valve.
Replace with a new valve diaphragm.
Repeatedly insert and pull out the air supply valve.
Remove beards and longer hair on the temples.
Wear the face mask again and tighten the elastic and
to make the mask press against the face.
Replace a tested air supply valve with another
normally-functioned valve to check whether there is a
failure in air supply valve or in pressure-reduccing
valve. If there is still an excessive resistance when
inhaling, it shows that there is nothing wrong with the
air supply valve. The pressure-reducing valve should
be replaced.
Possible causes Failure Elimination
18

Sköld SCBA Phantöm NFPA 2002
INSTRUCTION MANUAL
Problems
System leak
There is an air loss
after turning off
the cylinder
There is leakage in the
junction of pressure-reducing
valve and cylinder valve.
Check whether there is some material in the joint
surface and whether the “O” sealing ring is aging
and cracking. It should be replaced with a new one.
If coupling spindle loosens, tighten it again.
Screw off the nipple of medium-pressure pipe with
a spanner to check whether the sealing gasket is
intact. If not, it should be replaced.
Check whether there is a damage and deformation
in the plug of medium-pressure pipe in the air
supply valve. If there is a deformation or scape, the
plug should be replaced. If the plug is intact, then it
indicates that there is a leakage in the plug of quick
connector. The medium-pressure pipe should be
removed to return to the factory for inspection and
repair.
Tighten the medium-pressure safety valve or
change the sealing ring with open end wrench.
When replacing the “O” sealing ring, grab the
exhalation valve in the mask with one hand and
press the circlip with a thumb, and at the same
time pull out the air supply valve with other hand.
Remove the pressure-reducing valve from the
back-up and return it to the factory for inspection
and repair.
Screw clockwise the handwheel switch again.
Let out all the compressed air in the cylinder. Note
that air given out should not be too much. Remove
the handwheel cover and valve head and
assemble. Replace the gasket after changing a new
valve head.
Let out all the compressed air in the cylinder. Note
that air given out should not be too much. Enswathe
and fix the cylinder body with soft material. Replace
the gasket after removing cylinder valve.
Screw the safety valve.
Let out the compressed air in the cylinder.
Remove the safety valve and replace the
diaphragm of safety and protection.
There is leakage in the
junction of medium-pressure
pipe and pressure-reducing
valve.
There is leakage in quick
joints.
There is leakage in the
junction of medium-pressure
safety and pressure-reducing
valve.
There is leakage between the
mask interface and air supply
valve socket.
There is leakage in the body
of pressure-reducing valve.
The handwheel of the
cylinder is not fully tightened.
The is damage to sealing
surface of the valve head.
The gasket between
bottleneck and cylinder valve
becomes aging.
Safety
valve
There is a leakage in
the junction.
There is a crack in the
diaphragm of safety
and protection.
Possible causes Failure Elimination
19