* Add Suffix: (P)Packaged water boiler less tankless heater, (PT)Packaged water boiler with tankless heater, (PPT)Packaged water boiler with provision for tankless heater, (PZ)Packaged steam boiler less
tankless heater, (PZT)Packaged steam boiler with tankless heater.
† Ratings apply to the use of light oil at 140,000 Btu per gallon, and a .02% draft (negative pressure) over the fire.
‡ The net I=B=R output ratings shown are based on an allowance for piping and pickup of 1.15 (water) or 1.33 (steam). D.O.E. capacity gross output is divided by the allowance to obtain net rating.
The manufacturer should be consulted before selecting a boiler for unusual piping and pickup requirements such as intermittent system operation, extensive piping, etc.
§ Nominal clay tile liner dimensions.
** Tankless heater rating based on intermittent draw.
¶ Water boiler models TR-30, TR-40, TR-50, TR-60 and TR-70 have two firing rates. The boiler is factory shipped at the lower firing rate. To obtain the higher firing rate, refer to the Intrepid boiler installation
instructions for the appropriate field adjustments.
# I.B.R. gross output
∆Collar is oblong, will fit 6" diameter nominal
connector.
NOTE: All boilers under 300,000 Btuh input are
tested and rated for capacity under the U.S.
Department of Energy (D.O.E.) Test Procedures
for Boilers.
©Slant/Fin Corp. 2004. Printed in the U.S.A. 604. Publication No. TR-10.
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com
I
NTREPI
D
11B
11A
10
12
5A 5B
7
13 14 (Rear) 13
6
9
15
8
14 (Rear)
Front view STEAM Front view WATER Tapping
Location STEAM BOILER WATER BOILER
1 3" supply 11⁄2" supply
1A 2" supply tapping (rear section
of L-50, L-60 & L-70 models only) —
2 Second 1⁄4" siphon, pressure gauge
& pressure cut-out 3⁄4" air vent or expansion tank
33⁄4" steam safety valve 3⁄4" water relief valve
41⁄4" siphon, pressure gauge
& pressure cut-out —
5A — 1⁄2" tankless inlet
5B — 1⁄2" tankless outlet
6— 1⁄4" pressure temp. gauge
7— 1⁄2" hi limit, hi/lo or comb. control
83⁄4" low water cut-off, alternate —
91
1⁄2" skimmer tapping —
10 1⁄2" low limit for tankless —
11A 1⁄2" tankless inlet —
11B 1⁄2" tankless outlet —
12 1⁄2" steam gauge glass & 67 LWCO —
13 11⁄2" return & 3⁄4" drain cock 11⁄2" return & 3⁄4" drain cock
14 11⁄2" condensate return 11⁄2" alternate return
15 3⁄4" zone tapping —
Top view (Front section)
E
B
A
C
4"
A.S.M.E.
Relief
valve
Burner
Observation
port
Combustion Chamber
Left End—WATER & STEAM Front—STEAM BOILER Front—WATER BOILER
Supply
145⁄8"
25"
Combination
gauge
Tankless
heater
High/Lo limit
or combination
control for “P”
or “PT” boiler
Observation
Por t
LWCO
TR-20 0.75 105,000 91 — 79 — — 8 x 8 x 15 5 x 15 83.50 — 111⁄289⁄32 6∆11⁄4241⁄42 2.20 —
TR-30H 1.00 140,000 121 — 105 — — 8 x 8 x 15 6 x 15 86.00 — 147⁄8101⁄32 61
1⁄4275⁄83 3.00 —
TR-30¶1.10 154,000 134 134 117 101 421 8 x 8 x 15 6 x 15 84.85 84.15 147⁄8101⁄32 61
1⁄4275⁄83 3.20 3.00
1.25 175,000 151 — 131 — — 8 x 8 x 15 6 x 15 83.50 — 147⁄8101⁄32 61
1⁄4275⁄83 3.40 —
TR-40H 1.50 210,000 182 179 158 134 558 8 x 8 x 15 6 x 15 86.00 84.00 181⁄41123⁄32 71
1⁄431 4 3.80 3.40
TR-40¶1.60 224,000 195 195 170 146 608 8x8x15 7x15 84.45 83.80 181⁄41123⁄32 71
1⁄431 4 3.90 3.50
1.80 252,000 218 — 190 — — 8 x 8 x 15 7 x 15 83.33 — 181⁄41123⁄32 71
1⁄431 4 4.15 —
TR-50H 2.00 280,000 243 239 211 179 746 8 x 8 x 15 7 x 15 86.00 84.00 215⁄81313⁄32 81
1⁄2343⁄85 4.40 3.90
TR-50¶2.10 294,000 256 255 223 191 796 8 x 8 x 15 8 x 15 84.06 83.45 215⁄81313⁄32 81
1⁄2343⁄85 4.40 4.00
2.35 329,000 272#— 237 — — 8 x 12 x 15 8 x 15 — — 215⁄81313⁄32 81
1⁄2343⁄85 4.70 —
TR-60¶2.60 364,000 298#298#259 224 933 8 x 12 x 15 10 x 15 — — 25 153⁄32 81
1⁄2373⁄46 4.90 4.50
2.85 399,000 327#— 284 — — 8 x 12 x 15 10 x 15 — — 25 153⁄32 81
1⁄2373⁄46 5.20 —
TR-70¶3.10 434,000 352#354#306 266 1108 8 x 12 x 15 10 x 15 — — 283⁄81625⁄32 9— 41
1⁄87 5.45 5.00
3.35 469,000 381#— 331 — — 8 x 12 x 15 10 x 15 — — 283⁄81625⁄32 9— 41
1⁄87 5.70 —
Boiler
Model
No.
I=B=R Burner
Capacity
Oil Input
GPH†BTUH
D.O.E.
Heating
Capacity
MBH
Water Steam
I=B=R Burner
Net Ratings
Water
MBH‡Steam
MBH‡
Steam
Sq. Ft.
I=B=R Chimney Size
Nom. Rect.
x Height§
(in x in x ft)
I.D.Round
x Height
(in x ft)
A.F.U.E.
%
Water Steam
Dimensions (inches)
Boiler
Length
“A”
Front to
Flue
¢
“B”
Flue
Dia.
“C”
Return
Circulator
Flange
“D”
Overall
Length
“E”
Boiler
section
Tankless
Heater
GPM**
Water Steam
POP
safety
valve
Primary
control
Gauge glass
Gauge
Pressure
cut-out
control
Burner
251⁄2"
Water
line
Siphon
11⁄2"
skimmer
tapping
Primary
control
Burner
Drain
cock and
alternate
tapping
33⁄4"13⁄4"
31⁄2"
321
4
Flue
collector
317⁄8"
Service
switch
Tankless
limit
control
World class cast-iron oil-fired boilers
®