Sleavon D001F User manual

Home Dehumidifier
Please read the manual carefully
before using the unit
D001F
USER MANUAL
www.sleavon.com


Thank you for purchasing our dehumidifier.
Sleavon wishes that our products and services can bring convenience to your work
and life. We highly recommend that you keep the manual for reference if you
encounter unexpected events using the unit.
Please read the manual carefully to ensure proper use of the dehumidifier. Our
dehumidifiers are widely used in family bedrooms, bathrooms, basements, offices
and storage rooms, etc.
The dehumidifiers from provide quick and efficient operation to reduce Sleavon
room's humidity and bring you a healthy and comfortable life.
If there is any problem of the product, please contact Sleavon Customer Service
at with your Purchase Order ID to help you address the support@sleavon.com
problem more effectively.
FOR CUSTOMERS
TO ACCESS CUSTOMER SUPPORT FASTER

To prevent any internal damage, it is very important to keep
refrigeration units (like this one) upright throughout their journey.
Please leave it standing upright and outside the box for 24 HOURS
before plugging it in.
BEFORE FIRST USE:
88
%

TABLE OF CONTENTS
SAFETY INSTRUCTIONS .....................................................01
FEATURES & SPECIFICATIONS .......................................02
PRODUCT DRAWINGS ..........................................................03
MACHINE SETUP & OPERATION .....................................04
WATER DRAINAGE ................................................................06
MAINTENANCE & STORAGE.............................................09
TROUBLE SHOOTING...........................................................10
SPECIAL NOTES ......................................................................11
WARRANTY & CONTACT US ..............................................12

IMPORTANT NOTICE FOR FIRST USE:
For your safety, please read the manual carefully and keep the manual for future
reference. Please use this product according to the instructions of installation
and operation of this manual.
Don't try to repair, dismantle or modify this appliance, or it may cause damage.
Install the unit on flat and hard floor to diminish vibration or noise.
Never immerse the unit in water or other liquids.
Never operate the unit if the cable or other connector is damaged, or something abnormal may
happen, please call customer service for help.
Disconnect the unit from power supply when it is not in use, or before relocating or cleaning it.
Operate the unit only at the voltage specified.
The unit is for indoor use only. Don’t use it for other purpose.
Do not put heavy objects on the appliance.
Do not tip the unit to any side as spilled water may damage the appliance.
Never insert any other object into the unit body to avoid any hazard or unit failure.
Do not put the unit close to heat-generating devices or near flammable and dangerous materials.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
The appliance must be positioned so that the plug is accessible.
The appliance shall be installed in accordance with national wiring regulations.
The ambient temperature range for the appliance is 41℉- 95℉.
SAFETY INSTRUCTIONS

FEATURES & SPECIFICATIONS
SPECIFICATIONS
PRODUCT FEATURES
● 32 pints/day efficient dehumidification
● Three optional modes (AUTO, CNT, SLEEP)
● Compact and modern design
● Extremely quiet operation (36dB (A))
● Auto defrosting
This product can expose you to chemicals including Styrene and its compounds,
which are known to the State of California to cause cancer and birth defects or other
reproductive harm. For more information, please visit: www.P65Warning.ca.gov.
WARNING
Model No.
Power Source
Moisture Removal(65˚F,60%RH)
Moisture Removal(80˚F,60%RH)
Moisture Removal(86˚F,80%RH)
Moisture Removal(95˚F,90%RH)
IEF(65˚F, 60%RH)
HIGH PRESSURE
LOW PRESSURE
Noise
Refrigerant / Charge
Working Temp.
Product Dimensions
Net Weight
D001F
AC115V 60Hz
175W/1.9A
205W/2.1A
9 Pints/Day(4.2L/Day)
13 Pints/Day(6.1L/Day)
24 Pints/Day(11.3L/Day)
32 Pints/Day(15.1L/Day)
1.37 liters/kWh
204psi(1.41MPa)
88psi(0.60Mpa)
≤36dB(A)
R134a/3.35oz(95g)
41˚F - 95˚F
11*7.8*19.7in
11.0Kg/24.2 lbs
Power Consumption / Current(86°F,80%RH)
Power Consumption / Current(80°F,60%RH)

PRODUCT DRAWINGS
Front
Control Panel
Air Inlet
Air Outlet
Water Tank
Back
Continuous Drainage Outlet
Universal Castor
Display Screen
88
%

3. Mode
Auto Mode—Continuous Drying Mode cycle, press once to switch the mode from
one to each other, the corresponding indicator will light up.
MACHINE SETUP & OPERATION
Button Function
1. Power
In the standby status, press the "POWER" button to turn on the machine, the
operation indicator lights up, the default fan speed is high and the default
humidity is 50%. In the power-on status, press the "POWER" button to turn off
the machine, the running indicator light goes off and the compressor stops
immediately, and then the fan shut off after 30 seconds delay.
2. Humidity
Press the "HUMIDITY" button to check the current environment humidity, press again
to set the humidity. The range of target humidity is:
30%- 35% - 40% - 45% - 50% - 55%- 60% - 65% -70% - 75%- 80%.
After setting for 3 seconds, the system will confirm the input value and then the machine
exit setting status, and return the current humidity.
In the Drying Mode, the target humidity cannot be changed.
Long press the "HUMIDITY" button for 3 seconds will display the current ambient
temperature.
Blue
humidity<46%
Green
44%≤humidity≤66%
Red
humidity>64%
DIGITIAL DISPLAY
OPERATRIONS

4. Timer
Press the "TIMER" button to set the 0-24 hour timing function with the interval of 1 hour.
Each time you press this button, the value will increase by 1 hour and then the
corresponding timing value will be displayed on the screen.
When the value is set to be "00", it means to cancel the "TIMER" function, which will be
displayed by the indicator. After the timer has been successfully set, the indicator will be
on during the timing period.
After the timing is over, the indicator will turn off automatically.
In the machine-running status, set a time to turn off the machine.
In the standby status, set a time to turn on the machine.
5. Sleep mode
Press the "SLEEP" button, the button will light up and start the sleep feature.
If no more operation, all the indicators will turn dark gradually and the wind speed will
be automatically switched from high to low.
Press any button to wake up the indicator and touch the "SLEEP" button again will exit
the sleep mode.
The default humidity under Sleep Mode is 60% RH.
6. Fan
High wind— low wind cycle, press this button once to switch, the corresponding
indicator will light up.
In Continuous Drying Mode, Sleep Mode and Defrosting process, the wind speed can
not be adjusted.
7. Child-lock
Long press the "LOCK" button for 3 seconds to turn on/off the child-lock function.
MACHINE SETUP & OPERATION
Auto Mode: Machine will operate under the default humidity of 50% RH. Both
fan speed and humidity value can be adjusted under Auto Mode.
Continuous Drying Mode: The machine will continue to run, but the humidity
value can not be adjusted.

WATER DRAINAGE
Water Tank Full Alarm
Water Tank Indicator
When the tank is full for 5 seconds, it will activate the alarm, the water tank
indicator “ ” will turn red and the unit will buzz for 15 times.
Clear the alarm
When the alarm buzz is on, press any button to stop it. The compressor and fan will
shut off and all functions will suspend until the tank is emptied and put back in the
right position.
Empty the tank
Grab the notch at the bottom of the tank and pull it out with both your hands. Take
it out slowly and steadily in case spilling water.
Empty the water.
Put the water tank back in position. The dehumidifier will automatically start to
work again.

WATER DRAINAGE
PRECAUTIONS
Do not remove the float out of the
tank otherwise the dehumidifier
can not start up.
Ensure the water tank is in right
position when putting it back,
otherwise the dehumidifier can
not start up.
If the tank is dirty, wash it with cool/warm water. Do not use detergent,
steel balls, chemically treated dustproof cloth, gasoline, benzene, thinners
or other chemical solvents in case damage and leakage.
12
3
Working Distance
When the dehumidifier is in operation, make sure that the front and rear of the
dehumidifier maintains a minimum working distance of 20 cm from the
surrounding objects.
4

CONTINUOUS DRAINAGE
Take out the water tank
Use a water hose (diameter=9.5mm) to connect the water outlet.
Dress the water hose through the cutting hole of the tank and put the tank back
in place.
When continuous drainage, the end of the hose should not be submerged in the
water in case being blocked or damaged.
WATER DRAINAGE
Water Tank

Body Cleaning
Use a soft and slightly wet cloth to clean the dehumidifier body.
Filter Cleaning
1. Take off the filter mesh.
2. Use a vacuum cleaner to gently absorb the dust on the surface. If the filter is
very dirty, wash it with water and a soft cloth and dry it thoroughly afterwards.
3. Put the filter back.
MAINTENANCE & STORAGE
1. 2. 3.
STORAGE
When not using the product for a long time and intend to store it, please pay
attention to the following steps:
1. Empty the water in the water tank and wipe the water droplets at the bottom of
machine inside.
2. Roll up the power cord and tie it up.
3.Clean the filter.
4.Place the machine in a cool and dry environment.
MAINTENANCE

TROUBLE SHOOTING
Not working
No power supply.
Bad functioning
Water full indicator flashes.
No air intake
Is the air filter clogged?
Loud noise when running
Is the filter clogged?
Problem Possible Cause Solution
E2
Is the machine put in the plat place?
Humidity sensor problem.
Environmental humidity is below 20%.
Environmental humidity is above 90%.
FUNCTIONING TEMP.
41℉ ≤ Ambient Temp. ≤100 ℉
When the ambient temp. is lower or higher than the functioning temp., the dehumidifier
will stop operating.
When the machine is working between the ambient temperature of 41℉ and 61℉,the
compressor will automatically defrost at intervals.When defrosting, the compressor
will stop and the fan will keep running.
BEFORE CALLING FOR CUSTOMER SERVICE
Before contacting the professional service, you can take a time to review the Trouble
Shooting List that includes common occurrences that are not the result of defect in
workmanship or materials as below.
LO
HI
CL
CH
Room temperature ˂ 41℉, or ˃ 100 ℉.
Is the intake duct or discharge duct
obstructed?
Is the filter clogged?
Low temperature protection, the
environmental temperature<41℉.
High temperature protection, the
environmental temperature>100℉.
Connect to a functioning outlet and
switch on.
Drain water tank and reset it, or re-
position the water tank to right place.
Clean the air filter as instructed.
Wash the filter.
Put the machine on the plat ground.
Change a sensor.
The dehumidifier shuts down for
self- protection.
Self-protection designed to protect
the unit. Can not work under such
temperature.
Remove the obstruction from the
discharge duct or intake duct.
Wash the filter.

Do not insert thin rods and hard
objects into the machine body to
avoid malfunction and danger.
When cleaning the dehumidifier,
please use the wet textile to
wipe gently, do not shoot the
water directly.
Please clean the filter every two
weeks (do not use hot water
above 104°F, alcohol, gasoline
or toluene.)
When continuous drainage,
the drain hose must be
placed horizontally, without
unevenness and winding.
After cleaning the filter, please
do not dry it under direct
sunlight, in case deformation.
SPECIAL NOTES

P.12
Sleavon offers a 12-month warranty to all of our products together with the
original proof of purchase when a defect occured, including those newly
purchased and unused, from leavon or through an authorized reseller, wholly or S
substantially, or as a result of faulty manufacturing parts, or workmanship during
the Warranty Period.
The warranty does not apply if damage is caused by other factors, including but
without limitation of:
Register your product at to extend your 1-year warranty by an www.sleavon.com
additional year.
*Please fill out all required fields and inlcude your Order ID, Date of Purchased if
applicable.
Warranty
Extend Your Warranty by 1 Year
Customer Support
There are our general terms for the warranty service, but we always encourage our
customers to contact us if any issues, regardless of warranty terms.
If you are experiencing an issue with Sleavon product, you can reach out to us at
support@sleavon.com, we will dedicate our efforts to resolve it for you.
(a) Normal wear and tear;
(b) Abuse, mishandling, accident or failure to follow operating instructions;
(c) Exposure to liquid or infiltration of foreign particles;
(d) Servicing or modification of the product other than by Sleavon.
If you have any questions or concerns about your product, please feel free to
contact our expert support team. Sleavon customer service is here to help.
Sleavon Office
13211, Spring Street Baldwin Park, CA, US
Email: support@sleavon.com
Live Chat: www.sleavon.com
Support Hours
24 Hours available
*Please have your Order Number ready before contacting customer support.
WARRANTY & CONTACT US



We are expecting to see our products fulfill your life and hear your voice.
Your satisfaction means a lot to us.
Please tag us if you share a snap on your social media.
For FAQs and more information please visit:
www.sleavon.com
(Scan the QR Code for Live Chat)
www.sleavon.com
Sleavon
Sleavon
Sleavon
Sleavon
Table of contents
Other Sleavon Dehumidifier manuals
Popular Dehumidifier manuals by other brands

Gardner Denver
Gardner Denver DPB Series instruction manual

Meaco
Meaco 12L Low energy Dehumidifier user manual

Desert Aire
Desert Aire LW Installation and operation manual

SMC Networks
SMC Networks IDU3E-10 Operation manual

Parker
Parker CDAS HL 050 Series user guide

Bionaire
Bionaire BDH002X instruction manual