Specifications
Width 1.65” (42 mm)
Height 4“ (102 mm)
Depth 4.25” (107mm)
Dispenser Rate Approximately
1.2 mL per use
Capacity 1000 mL bottle
Specifications are subject to change
without notice.
Table of Contents Page
Parts/Dimensions 2
Installation Instructions 3-5
Operation 6
Maintenance/Replacements 7
Emergency Measures 8
Consumables 8
Sensor-
Operated,
Deck-Mount
Foam Soap
Dispenser

OVERVIEW OF PARTS AND DIMENSIONS
Foam tank
case unit
Foam soap
dispenser
Foam soap
dispenser
Note: Deck mount foam soap dispenser
shown mounted with faucet for reference.
Power cord
Liquid soap
and air tubes
Wiring
2

INSTALLATION
Check that all parts are included in
original packaging for proper installation.
Package contents:
Foam soap dispenser (1)
Dispenser shank nut, washer and packing
Connector case, stainless steel panhead
screws (2) and adhesive pad (1)
Tubing (1)
Foam tank case unit (1)
Screw kit (4-screw kit x 1)
Foam tank case key (2)
Tube clamp (2)
Wire clip (2)
Tools needed:
Drill
1/8” drill bit
1/4” masonry bit (if attaching to
concrete wall)
1” hole drill for drilling through
countertop
Adjustable wrench or basin wrench
Phillips head and slotted screwdrivers
Utility knife
Hammer
Ruler/tape measure
Precautions
Before using the dispenser, thoroughly
read the “Precautions” attached to the
liquid products.
Immediately clean any spill on the floor
to help avoid falling, injuries or other
hazards.
Choosing Installation Placement
For indoor use only.
Do not install in areas with high humidity
or where the unit may be exposed to
direct sunlight.
Install the unit on a sturdy horizontal
surface that is in ambient temperature
(0-35°C).
Make sure foam tank case unit will be
accessable from the underside of sink.
Prior to Installation
An electrical outlet is needed for
operation. It should be protected from any
contact with water and be within the
range of the power cord (approx. 70”). If
no outlet is available, consult licensed
electrician.
Locate final position of foam soap
dispenser and drill 1” hole in counter top.
STEP 1.
Remove unnecessary components
Remove unnecessary components from
washbowl or horizontal surface that are
mounted on the area where the foam
soap dispenser will be installed.
STEP 2.
Install foam soap
dispenser
Insert the foam
soap dispenser
shank into the
mounting hole.
Secure the foam
soap dispenser to
the countertop
using shank
packing, washer
and nut.
Foam soap
dispenser
Shank
1” hole in
counter top
Packing
Washer
Nut
3

Removing tubes
When removing a tube from a fitting,
remove the clamp first and then pull out
the tube from the fitting.
To reconnect a removed tube to a fitting,
retrim tip of the tube at right angle prior
to connecting.
INSTALLATION
58
116
200
220
Foam soap tube
from foam soap
dispenser
Air tube from foam
soap dispenser
Foam soap tube
fitting Air tube fitting
Fittings
connection label
Foam tank
case unit
Tube clamps
STEP 3.
Install foam tank case unit to wall
Before installing on the wall, check that no
other piping and wiring is running behind
hole locations.Wall should sufficiently
reinforced or risk failure due to foam tank
case unit falling.
• Determine a temporary position for
mounting the foam tank case unit.
• Make sure unit is within reach of the
liquid soap and air tube from the foam
soap dispenser.
• Use the mounting bracket as a guide,
mark where holes need to be drilled.
Important: Make sure bracket and
foam tank case unit is mounted level.
• When installing onto a concrete wall,
drill holes 1.125” deep using a 1/4”
masonry drill bit. Insert wall anchors
into the holes and mount the dispenser
using screws.
• When installing onto a wood wall, drill
holes using a 1/8” drill bit and attach the
dispenser using screws.
STEP 4.
Connect foam soap tube and air tube
Connect the foam soap tube and air tube
from the foam soap dispenser into the
soap tube fitting and air tube fitting found
on top of the foam tank case unit,
respectively.
• Check soap tube tags and align with
correct fittings as indicated on the
fittings connection label.
• Cut the soap tube and the air tube at
suitable lengths. Ends should be cut at
right angles and tubes should be free of
kinks and bends when connected.
• Insert soap tube and air tube into
respective fittings and secure with
tube clamps.
4

58
116
200
220
Connect wiring
Connect the relay harness, which comes
from the bottom of the foam tank base
case unit, with the hand sensor harness,
which comes from the foam soap
dispenser.
Protect wire connections
Feed the connectors of the relay harness
and hand sensor harness into the
connector case as shown in illustration.
After positioning all wiring, fold the
connector case in half and close using two
stainless steel panhead screws.
• Be careful not to pinch the wiring in the
connector case.
Mount connector case
Completely clean the area where affixing
the connector case. Remove liner and affix
one side of the adhesive pad to the back
of the connector case.
Remove the adhesive liner on the pad
affixed on the connector case and attach
to the underside or back of basin or sink.
• When mounting the connector case,
screws must be accessable in case
wiring needs accessing.
• Harness openings must face down to
keep water from entering case.
Attach wire guide clips
• Attach wire guide clips to the bracket
and secure wires.
Plug in to electrical outlet
58
116
200
220
From foam soap
dispenser
Hand
sensor
harness
Relay
harness
From foam
tank case unit
Hand
sensor
harness
Connectors
Relay
harness
58
116
200
220
Connectors
Harness
openings
Connector case
Stainless
steel
panhead
screws
Adhesive
mounting pad
5
Wire guide
clips

6
Replacing Soap
The foam soap indicator light on the
foam soap dispenser blinks and stops
dispensing when the soap bottle in the
foam tank case unit runs out. Change the
soap bottle.
• Turn the key to open the foam tank
case unit
cabinet door.
• Remove the
joint cap and
dip tube and
discard empty
soap bottle.
• Insert the dip
tube and attach
the joint cap to
the new bottle and install the bottle in
the tank cabinet. Be sure to attach the
joint cap securely.
• Close the door and lock using key.
Cleaning
For reliable long-term use, perform regular
maintenance for the unit. Be sure to turn
off the operation switch and check that
the operation light is off when
maintenance is done. Remove soil with a
soft, dry cloth. If the unit is seriously
polluted on portions other than the hand
sensor, use wet cloths properly diluted
neutral detergent.Then remove the
detergent with a soft damp cloth and then
rub with a soft, dry cloth.
MAINTENANCE
Operation
Mount soap bottle to the foam tank case
unit. Press the reset switch, which begins
the pumping cycle to purge air from the
tube.This step may be required twice to
completely prime the unit.
Place hands under foam soap dispenser.
The sensor will detect the presence
(approximately 0.6 seconds) and dispense
foam soap from the foam soap dispenser.
Check for leaks from the bottle or
dispensing unit. Soap should only be
dispensed through the outlet spout.
NOTE: This procedure must be completed
every time a bottle is replaced.
OPERATION
Liquid soap
bottle
Reset switch
Operation light
Operation switch
Operation panel
Foam tank
case unit
Joint cap
Joint cap
Joint
cap

Cleaning foam soap dispenser
If the tip of the soap nozzle is clogged, the
dispensing capability may fail or function
partially. Clean the nozzle according to the
following procedure:
• Press the operation switch to OFF (the
operation light goes off).
• Remove the
foam soap
dispensing
nozzle and
then the
internal mesh.
Wash it with
lukewarm water.
• Turn ON the operation switch (the
operation light goes on). Check the
foam soap spraying state.
• Repeat as needed.
7
Cleaning the hand sensor
Clean the hand sensor periodically (about
once a month) according to the following
procedure:
• Press the operation switch to OFF (the
operation light goes off).
• Gently wipe the hand sensor area with a
cloth moistened with warm water.
• Press the operation switch to ON (the
operation light goes on).
• Make sure that the nozzles properly
dispenses foam soap.
NOTE: Do not leave water drops on the
hand sensor area. Remaining water drops
may cause a malfunction.
Mesh
Nozzle
Before Calling for Repair
Problem Action
Unit does not operate. Check operation switch is on.
Check power plug is securely inserted to the outlet.
Soap does not dispense Soap bottle needs replacing.
Check soap dispensing nozzle for clog.
Clean hand sensor.
Liquid soap is not in foam state Check mesh is mounted in the
foam-dispensing nozzle.

The information contained in this document is
subject to change without notice. For most current
information, refer to online installation and operating
instruction manuals at www.sloanjansan.com
SLOAN JANSAN
A Division of Sloan Valve Company
10500 Seymour Avenue
Franklin Park, IL 60131-1259
Phone: 877-6-JANSAN (877-652-6726)
Fax: 800-447-8329
www.sloanjansan.com
©2006 Sloan Valve Company
Sloan JANSAN
A Division of Sloan Valve Company
Printed in the U.S.A. JSD6061 11/06
CONSUMABLES
Product No. Description Order No.
SJS-1751 Sensor Deck-Mount Foam Soap 0700751
SJS-1751-1 Sensor Deck-Mount Foam Soap with Moisturizers 0700752
SJS-1751-2 Sensor Deck-Mount Antimicrobial Foam Soap 0700753
EMERGENCY MEASURES
Take action according to the chemical
being used as listed on the container. See
the Material Safety Data Sheets.
Eye Contact: Flush eyes with water for a
minimum of 15 minutes and consult a
physician immediately.
Ingestion: Drink water to induce vomiting
and consult a physician immediately.
Inhalation: Get fresh air immediately. If
condition does not improve, consult a
physician immediately.
Table of contents