SMC Networks IZE11 Series Instruction Manual

Item IZE11
Analogue
output
Response time
(including sensor
response time)
200ms (No filter)
1.5s (with filter) or less
Indicator Accuracy ±0.5%F.S. ±1digit or less
Display method 3 1/2 digits 7 segment display, two color (red /green)
indication, sampling cycle : 5 times /1s
Indicator lamp OUT1 : Turns on when ON (green)
OUT2 : Turns on when ON (red)
Environmental resistance
Enclosure IP40
Operating temp.
range
Operation: 0 to 50°C, Storage : -10 to 60°C (No
condensation or freezing)
Operating humidity
range
Operation storage : 35 to 85% R.H.
(No condensation)
Withstand voltage 1000VAC 1 min.
Between live parts and enclosure at monitor alone
Insulation
resistance
50 Ω or more (at 500VDC mega)
Between live parts and enclosure at monitor alone
Vibration
resistance
10 to 150Hz smaller one 1.5mm or 98m/s2double
amplitude each in directions of X, Y, and Z for 2
hours (De-energizing)
Impact resistance
100m/s2
3 times each in directions of X, Y, and Z respectively
(De-energizing)
Temp. characteristic ±0.5%F.S. or less (25°C)
Connection Power and output lead wire : 5P connector
Connector for sensor lead wire : 4P connector
aterial Front case : PBT, Back case : PBT
Weight 30g (Power supply and output cable not included)
Standard CE marking, UL (CSA) standards
Note
Follow the instructions given below when operating the electrostatic
sensor monitor.
Otherwise, the electrostatic sensor monitor may be damaged or may
fail, thereby resulting in malfunction.
• Do not pull the lead wire forcefully, or lift the product by pulling the
lead wire.
• Do not use in a place where oil or chemical splashes may occur.
• Connect Terminal FG to the ground when using a switching regulator
obtained on the commercial market.
• Insert a noise filter (line noise filter, ferrite element or other element)
between the switching regulator and monitor when analog output is
used.
• Do not press the buttons with a sharp pointed object.
• To measure small electric potential, 20 to 30 min. of warm-up time is
necessary. Initial drift of about ±1% F.S. occurs immediately after
turning the power on.
• Start measurement by the monitor 3s after turning the power on.
easurement output will be inaccurate for the first 3s.
• The direct-current power supply to combine should use UL
authorization power supply which is the class 2 power supply based
on UL1310 or the power supply is using the transformer of a class 2
based on UL1585.
• Electrostatic sensor or monitor will not withstand lightning surges.
Protection against it must be provided for the device.
• Do not turn off the power supply while setting functions to avoid
storing of incorrect values or settings.
IZE11-TFK08GB-A
Installation & Maintenance Manual
Electrostatic Sensor Monitor
Series IZE11
1 Safety Instructions
If instructions are not followed there is a
possibility of serious injury or loss of life.
If instructions are not followed there is a
possibility of injury or equipment damage.
1 Safety Instructions (continued)
WARNING
CA TION
•This manual contains essential information for the protection of users
and others from possible injury and/or equipment damage.
• Read this manual before using the product, to ensure correct handling,
and read the manuals of related apparatus before use.
• Keep this manual in a safe place for future reference.
• These instructions indicate the level of potential hazard by label of
“DANGER”, “WARNING” or “CAUTION”, followed by important safety
information which must be carefully followed.
• To ensure safety of personnel and equipment the safety instructions in
this manual and the product catalogue must be observed, along with
other relevant safety practices.
WARNING
3 How to Order
2 Specifications
•Do not disassemble, modify (including change of printed circuit
board) or repair the product.
An injury or product failure may result.
•Do not operate the product beyond the specification range.
Fire, malfunction or equipment damage may result. Use the product
only after confirming the specifications.
•Do not use the product in the presence of flammable, explosive
or corrosive gas.
Fire, explosion or corrosion may result. This product does not have an
explosion proof construction.
•When using the product as part of an interlocking system:
1) Provide a double interlocking system, for example a mechanical
system.
2) Check the product regularly to ensure proper operation.
•Before performing maintenance, be sure of the following:
1) Turn off the power supply.
•Sensor to connect must be selected.
Actual potential can not be displayed unless selected value of the
connect sensor is correctly set.
At initial setting or when sensor connected, ensure the selected value
of the connected sensor and the type of used electrostatic sensor are
matched.
•Always perform a system check after maintenance.
Do not use the product if any error occurs.
Safety cannot be assured if caused by un-intentional malfunction.
•Provide grounding to ensure correct operation and to improve
noise resistance of the product.
This product should be individually grounded using a short cable.
•Follow the instructions given below when handling the product.
Failing to do so may result in product damage.
• aintenance space should always be provided around the product.
• Do not remove labels from the product.
• Do not drop, hit or apply excessive shock to the product.
•Follow all specified tightening torques.
• Do not bend, apply tensile force, or apply force by placing heavy loads,
on the cables.
• Connect wires and cables correctly, and do not connect while the power
is ON.
• Do not route wires and cables together with power or high-voltage
cables.
• Check the insulation of wires and cables.
• Take proper measures against noise, such as noise filters, when the
product is incorporated in equipment or devices.
• Select the required protection (IP) rating according to the environment
of operation.
• Take sufficient shielding measures when the product is to be used in
the following conditions:
(1) where noise due to static electricity is generated.
(2) where electro-magnetic field strength is high.
(3) where radioactivity is present.
(4) where power lines are located.
• Do not use the product in a place where electric surges are generated.
• Use suitable surge protection when a surge generating load such as a
solenoid valve are to be directly driven.
• Prevent any foreign matter from entering this product.
• Do not expose the product to vibration or impact.
• Use the product within the specified ambient temperature range.
• Do not expose the product to any heat radiation.
• Do not clean the product with chemicals such as benzene or thinners.
IZE11
-
Output specification
0
1
2
NPN open collector 2 outputs + Analogue output (1 to 5V)
ContentsModel
NPN open collector 2 outputs + Analogue output (4 to 20mA)
PNP open collector 2 outputs + Analogue output (1 to 5V)
3
PNP open collector 2 outputs + Analogue output (4 to 20mA)
Option 1
Nil No option
Contents
Model
Power and output lead wire with cable
L
Option 2
A
Nil No option
Contents
Model
Bracket
D
B Panel mount adapter
Panel mount adapter
+ Front face protective cover
Option 3
Nil
C
No option
Contents
Model
Connector for sensor lead wire
Option/Part number
Power and output lead wire with cable (2m)
Bracket
Connector for sensor lead wire
ZS-28-A
Part no.
Description
ZS-28-B
ZS-28-C
Panel mount adapter
Panel mount adapter
+ Front face protective cover
ZS-27-C
ZS-27-D
Note
1pc.
With M3 5L (2pcs.)
With M3 5L (2pcs.)
With M3 5L (2pcs.)
4 Mounting and Installation
M3 5L
Bracket
(Type ZS-28-B)
M3 5L
Panel mount adapter (Type ZS-27-C)
M3 8L
Panel
Front face protective cover
(Type ZS-27-01)
Panel mount adapter can be attached also
in the position turned 90 degrees.
31.5
26.5
8.8
3.2
4
1.6
7
4.2
10
15
30
20
35
22
3.2
Mounting
•
ount the optional bracket and panel mount adapter to the controller.
Mounting by bracket
•Fix the bracket to the controller with the set screws 3 5L (2pcs.) as
attached.
•The tightening torque of the set screws must be 0.5 to 0.7N∙m.
Mounting by Panel mount adapter
•Fix the panel mount adapter to the controller with the set screws 3
8L (2pcs.) as attached.
Note1) Rated value when the distance between charged object and the sensor is 25mm.
Note2) Rated value when the distance between charged object and the sensor is 50mm.
IZE11
Connected sensor Sensor for ±0.4kV Sensor for ± 20 kV
Rated measured range -0.4 kV to +0.4 kV Note. 1) -20 kV to +20 kV Note. 2)
Set min. unit 0.001 kV 0.1 kV
Set measurement distance 10 to 50 mm 25 to 75 mm
Power supply voltage 24VDC ±10% or less
(protection against reversed connection)
Current consumption 50mA or less (Except current consumption at sensor)
Sensor input 1to 5VDC (Input impedance : 1M )
Input number 1 input
Input protection Protection against excess voltage (up to 26.4V)
Hysteresis Hysteresis mode : Variable
Window comparator mode : Variable
NPN or PNP open collector output 2 outputs.
Max. load current 80 mA
Max. applied voltage
30VDC (@ NPN output)
Residual voltage 1V or less (@ 80mA load current)
Short circuit protection
Short circuit protection included
Response time
(including sensor
response time)
100ms or less
When anti-chattering function is used,
Response time is 500ms, 1s, 2s or less
Analogue output
Voltage output
Output voltage : 1 to 5V
(within rated measurement range)
Output impedance : Approx. 1k
Accuracy (to display
value 25°C) ±1%F.S. or less
Current output
Output current : 4 to 20mA (Rated measurement range)
Max. load impedance : 600 (@ 24VDC)
Min. load impedance : 50
±1%F.S. or less
Switch output
Item
Accuracy (to display
value 25°C)
CA TION

LCD display
Output (OUT1) display (Green)
Output (OUT2) display (Red)
button
button
button
IZE11-TFK08GB-A
6 Names / Functions of individual Parts 7 Internal Circuit and Wiring
Power and output lead wire
with cable
Connector for
sensor lead wire
Conductor size : 0.14mm2to 0.2mm2
Overall diameter : 0.8 to 1.0
Bracket
Front face protective cover
Panel mount adapter
Output (OUT1) display (Green) : Lit when OUT1 is ON.
Output (OUT2) display (Red) : Lit when OUT2 is ON.
LCD display : Displays the current status of charged potential, set mode
condition and error code. Four display modes can be selected
display always in red or green only, or changing from green to
red linked to output.
button : Selects a mode and increases a set ON/OFF value. Press this
button to change to the peak display mode.
button : Selects a mode and decreases a set ON/OFF value. Press
this button to change to the bottom display mode.
button : Changes the mode and sets a set value.
Options
Power and output lead wire with cable (2m) : ZS-28-A
Connector for sensor lead wire (1pc.) : ZS-28-C
Bracket with set screws 3 5L (2pcs.) : ZS-28-B
Panel mount adapter with set screws 3 8L (2pcs.) : ZS-27-C
Panel mount adapter with set screws 3 8L (2pcs.)
+ Front face protective cover : ZS-27-D
Front face protective cover : ZS-27-01
5 Outline dimensions (mm)
Notice when removing the controller
•The controller with adapter
for panel mounting can be
removed from facility by
opening hooks of the
controller as illustrated after
removing two screws.
Pressure sensor controller
and Panel mount adapter
may be damaged.
Hook
Hook
31
0
-0.4
31
0
-0.4
Note)
4-R2 or less
Panel Hole Dimensions Panel Thickness : 0.5 to 6mm
31 n+ 3.5 (n-1)
31
0
-0.4
more than 24
Note)
4-R2 or less
31
0
-0.4
31 n+ 3.5 (n-1)
more than 24
Note)
4-R2or less
Two or more in row
n : The number of controllers
Separate
Horizontal
Vertical
4 Mounting and Installation
(continued)
Attaching the connector to the lead wire
•Strip the sensor wire as shown in the figure.
(Do not strip the cable wire sheath)
•The core of the corresponding color shown
in the following table is put into the correct
pin number printed on the connector and
pushed to the back.
•The centre part A is pushed straight in
using a suitable tool, such as pliers.
•Re-use cannot be performed once the
connector has been closed completely.
When connection failure occurs such as
incorrect fitting of wires, or incomplete
insertion, please use a new connector.
•When the sensor cable is a short length, do not connect the shield wire.
(The shield wire is common with amplifier case. Frame ground should be
prepared at the amplifier case side.)
Connection
• ake connection after turning the power off.
•Install the lead wire separately from the route for power cable or high-voltage
cable. Otherwise, malfunction may potentially result due to noise.
•Be sure to ground Terminal FG when using a switching regulator obtained
on the commercial market. If analogue output is performed connecting to
a switching regulator obtained on the market, switching noise will be
superimposed and product specification can no longer be met. This can
be prevented by inserting a noise filter, such as a line noise filter and a
ferrite element, between the switching regulator and the controller, or by
using a series power supply instead of a switching regulator.
Wire Color
Brown (DC +)
NC
White (IN : 1 to 5VDC)
Blue (DC
-
)
Pin No.
1
2
4
3
more than 20mm
A
•Check that the above-mentioned preparation work has been performed
correctly, and A part shown in the figure is pushed by hand and makes
temporary connection.
4 Mounting and Installation
(continued)
Connector Connecting /Disconnecting
• When connecting the connector, insert it straight onto the pin holding
the lever and connector body and lock the connector by pushing the
lever claw into the square groove in the housing until connector clicks.
• When disconnecting the connector, push down the lever to disengage
the lever claw from the square groove. Then pull the connector straight
out.
Lever
Connector for sensor lead wire
Lever
Power and output lead wire
with connector
DC(
-
)
Blue 1
Analogue
Grey 2
OUT2
White 3
OUT1
Black 4
DC(+) Brown 5
Power and Output Connector Pin numbers
3.21.5
31
1.5
30
EDS MONITOR
20 0.1
Note) When R is required, specify
R2 or less.
6 Names / Functions of individual Parts
(continued)

IZE11-TFK08GB-A
7 Internal Circuit and Wiring
(continued)
IZE112
PNP Open Collector Output :
2 Outputs
ax. 80mA
Residual voltage 1V or less
Analogue Output : 1 to 5V
Output Impedance :
Approx.1kΩ
IZE113
PNP Open Collector Output :
2 Outputs
ax. 80mA
Residual voltage 1V or less
Analogue Output : 4 to 20mA
ax. Load Impedance :
600Ω (@ 24VDC)
in. Load Impedance :
50Ω
DC (+)
Main Circuit
24VDC
+
-
(Brown)
Load
Analogue Output
(Grey)
(Black)
(White)
(Blue)
OUT1
OUT2
DC (
-
)
Load
Load
Sensor
White
Blue
Brown
NC
4
3
2
1
DC (+)
Main Circuit
24VDC
+
-
(Brown)
Load
Analogue Output
(Grey)
(Black)
(White)
(Blue)
OUT1
OUT2
DC (
-
)
Load
Load
Sensor
White
Blue
Brown
NC
4
3
2
1
Output Specification
When the S C power and output lead wire (type ZS-28-A) is used, the
colors of wire (Brown, Black, White, Grey, Blue) will apply as shown on
the circuit diagram.
IZE110
NPN Open Collector Output :
2 Outputs
ax. 30V, 80mA
Residual voltage 1V or less
Analogue Output : 1 to 5V
Output Impedance :
Approx. 1kΩ
DC (+)
Main Circuit
24VDC
+
-
Load
(Brown)
Load
Analogue Output
(Grey)
(Black)
(White)
(Blue)
OUT1
OUT2
DC (
-
)Load
Sensor
White
Blue
Brown
NC
4
3
2
1
DC (+)
Main Circuit
24VDC
+
-
Load
(Brown)
Load
Analogue Output
(Grey)
(Black)
(White)
(Blue)
OUT1
OUT2
DC (
-
)Load
Sensor
White
Blue
Brown
NC
4
3
2
1
IZE111
NPN Open Collector Output :
2 Outputs
ax. 30V, 80mA
Residual voltage 1V or less
Analogue Output : 4 to 20mA
ax. Load Impedance:
600Ω (@ 24VDC)
in. Load Impedance:
50Ω
AU TRIA (43) 2262 62280 NETHERLAND (31) 20 531 8888
BELGIUM (32) 3 355 1464 NORWAY (47) 67 12 90 20
CZECH REP. (420) 541 424 611 POLAND (48) 22 211 9600
DENMARK (45) 7025 2900 PORTUGAL (351) 21 471 1880
FINLAND (358) 207 513513 LOVAKIA (421) 2 444 56725
FRANCE (33) 1 6476 1000 LOVENIA (386) 73 885 412
GERMANY (49) 6103 4020 PAIN (34) 945 184 100
GREECE (30) 210 271 7265 WEDEN (46) 8 603 1200
HUNGARY (36) 23 511 390 WITZERLAND (41) 52 396 3131
IRELAND (353) 1 403 9000 UNITED KINGDOM (44) 1908 563888
ITALY (39) 02 92711
URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)
pecifications are subject to change without prior notice from the manufacturer.
© MC Corporation All Rights Reserved.
8 Contacts
Other manuals for IZE11 Series
1
Other SMC Networks Monitor manuals