Snap-On Level 5 VTC eLock 200 Series User manual

1
200/300 Series — VTC eLock Instructions
200/300 Series
– VTC eLock Instructions
Thank you for purchasing the VTC eLock.The information
contained in these instructions is intended to serve as a
guide so as to allow the eLock to be quickly and easily
put into service. 300 Series eLock can be configured to
work in conjunction with existing 802.11g or Ethernet
networks.
For complete set up and installation instructions for
networked and stand-alone eLocks, please see the
“Help” section in LockView NTC/VTC Software v4.
1. Dot matrix LCD
2. Network button (blue LED)
3. “UP” button
4. “NEXT/SELECT” button
5. “BACK/CANCEL” button
6. “MENU” button
7. “DOWN” button
8. + Button
9. - Button
10. Low battery indicator
(yellow LED)
11. Magstripe reader location
(if equipped)
12. HID Prox or HID iCLASS
reader location (if
equipped)
13. “ENTER” button
14. “CLEAR” button
15. Alpha-numeric keypad
1
2
3
4
5
6
78 9 10
15
14
13
12
11
VTC eLock controller
Network VTC eLock has three components:
Controller Motorized gear-driven latch Control module / battery compartment
Exterior mount
Interior mount
VTC

200/300 Series — VTC eLock Instructions
2
200/300 Series VTC eLock — Components
Front view:
eLock controller
Back view: VTC
eLock controller
Battery cable connector
Integrated Wi-Fi
antenna cable
included for 300
Series Wi-Fi version
200/300 Series VTC eLock Components
9V Battery
Jumper Port
USB Port for direct connection
to LockView software

3
200/300 Series — VTC eLock Instructions
200/300 Series VTC eLock — Components continued
Control module /
battery compartment
1 2 3 4 5 6 7
8
1. Door switch connector (door
switch not included)
2. Wi-Fi antenna cable connector
or Ethernet connector
(Wi-Fi
connector shown; 300 Series only)
3. Control module / battery cable
connector
4. 2.5 mm AC adapter plug-in
(adapter not included)
5. Ground terminal
6. Dual eLatch connector (Latch 2, if
equipped; one latch is included)
7. Latch connector (Latch 1; one
latch is included)
8. Battery pack cover (6-AA batteries
not included)

200/300 Series — VTC eLock Instructions
4
Unit Features:
wChoose 802.11g or Ethernet Networked configurations that
uses the facilities existing infrastructure for actual 2-way
read/write communication
wEach eLock can hold any combination of up to 3,000
Supervisors and Users
wChoose a model to use existing HID Prox, HID iCLASS, or
magstripe card credentials that can be programmed to
operate each eLock
wRemote Notification System with programmable escalating
alerts via SMTP email; SMS text, voice and fax (Networked
eLock & LockView NTC/VTC Software v4 required)
wSpring bolt latching mechanism provides automatic
relocking
wOptional second latch drive output (requires additional
hardware)
wDoor position switch input (requires additional hardware)
wMembrane keypads with stainless steel domes provides
durable performance and easy cleaning
What’s in the box?
w1 – eLock controller
w1 – motorized latch w/latch cable
w1 – control module / battery compartment with interconnect
cable
w1 – serial code sticker set
w1 – in-box instructions
What’s needed?
w6 – AA alkaline batteries
wT15 pin-in Torx (6-lobe) bit or driver
Care and Cleaning
The eLock is a battery operated device, therefore, it should
be part of a regular battery maintenance program.
Warning: install the batteries as shown in the battery
compartment. Polarity (+) or (-) must be correct. Replace
batteries as a set. Always use new batteries when replacing
the old set. Do not combine a used battery with a new one.
Only use alkaline batteries; do not mix battery types.
To clean the surface of the eLock, apply non-acid based
cleaner to a clean cotton cloth; do not spray cleaner directly
on the eLock. Wipe down keypad and housing taking care
around the beeper opening and edges of keypads. Wipe
excess cleaner off of all surfaces.
Setting up the eLock
Getting Started Out of the Box
If the eLock is stand-alone 200 Series (direct connection
via USB to LockView NTC/VTC Software v4) and will be
used in conjunction with LockView NTC/VTC Software v4,
please follow the LockView Mode Instructions on page 6.
For Networked (802.11g or Ethernet) 300 Series eLocks,
please follow the eLock Database & Network Configuration
& Install Manual and the LockView NTC/VTC Software v4
Instruction Manual before proceeding.
INITIAL PROGRAMMING:
The unit is shipped with a preprogrammed 2801 Supervisor
code.
Credential Menu
ADD CREDENTIAL
Note: There are two status levels; Supervisor and User. Each
eLock can hold any combination of up to 3,000 Supervisors
and Users.
Only Supervisors are allowed to ADD Users and Supervisors.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Enter 2801 and press “ENTER.”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT.”
4. Highlight ADD CREDENTIAL and press “NEXT/SELECT.”
5. CREDENTIAL TO ADD will be displayed. Scan new credential
or enter new 4-14 digit PIN and Press “ENTER.”
6. Adding credential will be displayed.
7. Default status is User. To change status to Supervisor press
the +button.
8. The new User/Supervisor will be added to the next available
slot number. To change the slot number, press “UP” and then
+/- to move to next available slot; or use the numeric keypad
to enter the desired slot number and press “NEXT/SELECT.”
200/300 Series VTC eLock — Instructions

5
200/300 Series — VTC eLock Instructions
9. CREDENTIAL NAME ENTRY will appear. Press 2 - 9 for A - Z;
press 1 for -, ., +or _; press 0 for “space”; press and hold
0 - 9 for numbers. (Maximum number of allowed characters
is 14.)
10. Press “ENTER” when done. STORED will be displayed when
complete.
Operating the eLock
Follow the instructions below to operate the eLock.
PIN CREDENTIAL
1. Enter a valid PIN (between 4 - 14 digits) and
2. Press “ENTER.”
CARD CREDENTIAL
If the eLock is equipped with a card reader (HID Prox, HID
iCLASS or a Magstripe)
1. Present a valid card within range of the HID reader or slide
the magstripe card through the magstripe reader.
DUAL CREDENTIAL
If the User or Supervisor requires a dual credential
1. Enter a valid PIN and press “ENTER” (for keypad credentials)
or present a valid card (for HID Prox or HID iCLASS or
Magstripe credentials).
2. Enter the second credential (4-14 digit PIN) and press
“ENTER.”
NOTE: THE SECOND CREDENTIAL MUST ALWAYS BE
A 4 - 14 DIGIT PIN
PASSAGE MODE
(LockView software required) To hold the latch bolt in the
open position indefinitely, there is a setting in LockView
called Passage Mode.
Passage Mode can be assigned to an eLock and/or a
Supervisor/User credential.
In LockView, via the Lock Editor, Passage Mode can be
selected so that every valid User or Supervisor that has
access rights to the eLock can place it in passage mode.
In LockView, via the User Editor, Passage Mode can be
selected. Users and Supervisors can place any eLock to which
they have access right into Passage Mode. This is regardless
of whether or not Passage Mode has been activated in the
eLock.
To place an eLock into Passage Mode:
PIN CREDENTIAL
1. Enter a valid PIN (between 4 - 14 digits) and press “ENTER.”
2. Press “ENTER” again. HOLD OPEN will flash; LOCK IS HELD
OPEN will appear in the upper left hand corner of the LCD.
CARD CREDENTIAL
If the eLock is equipped with a card reader (HID Prox, HID
iCLASS or Magstripe):
1. Present a valid card within range of the HID reader or slide
the magstripe card through the magstripe reader.
2. Press “ENTER.” HOLD OPEN will flash; LOCK IS HELD OPEN
will appear in the upper left hand corner of the LCD.
DUAL CREDENTIAL
If the User or Supervisor requires a dual credential:
1. Enter a valid PIN and press “ENTER” (for keypad credentials)
or present a valid card (for HID Prox, HID iCLASS or magstripe
credentials).
2. Enter the second credential (4-14 digit PIN) and press
“ENTER”
3. Press “ENTER” again. HOLD OPEN will flash; LOCK IS HELD
OPEN will appear in the upper left hand corner of the LCD.
NOTE: THE SECOND CREDENTIAL MUST ALWAYS BE A 4 - 14
DIGIT PIN
To EXIT Passage Mode (re-lock the unit/extend the eLock
latch bolt):
PIN CREDENTIAL
1. Enter a valid PIN (between 4 - 14 digits)
2. Press “ENTER.” EXITING PASSAGE MODE will flash on the
LCD and the latch bolt will extend.
CARD CREDENTIAL
If the eLock is equipped with a card reader (HID Prox, HID
iCLASS or Magstripe):
1. Present a valid card within range of the HID reader or slide
the magstripe card through the magstripe reader. EXITING
PASSAGE MODE will flash on the LCD and the latch bolt will
extend.
DUAL CREDENTIAL
If the User or Supervisor requires a dual credential:
1. Enter the primary valid PIN (for keypad credentials) and
press “ENTER” or present the valid card (for HID Prox, HID
200/300 Series VTC eLock — Instructions continued

200/300 Series — VTC eLock Instructions
6
iCLASS or Magstripe credentials). EXITING PASSAGE MODE
will flash on the LCD and the latch bolt will extend.
Methods to begin building
a database of eLocks in
LockView Software
Note: Supervisor, User and parameter changes that already
exist in the eLock will automatically be carried into
LockView once the eLock has been enrolled.
For Networked (802.11g or Ethernet) eLocks, please follow
the eLock Database & Network Configuration & Install
Manual and the LockView NTC/VTC Software Instruction
Manual before proceeding.
LockView Mode Instructions
(For complete details on how to build a database of
users and eLocks, see the LockView NTC/VTC Software
Instruction Manual and eLock Manual Programming Guide)
LockView NTC/VTC Software v4 must be installed and the
eLock must be in SETUP mode before continuing. (See
Setup Code section on page 10.)
Stand-alone eLocks (Direct USB connection to laptop
computer with LockView is required) There are two methods
that can be used to add eLocks to the LockView software.
Automatic Method
1. With the eLock in SETUP mode, connect the eLock via the
USB cable to the computer on which LockView is installed.
2. Login to LockView.
3. After 30 seconds, the below will appear.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.
4. Click Yes.
5. The below will appear. Type in the name of the lock.
**Once a Lock Name has been chosen in LockView, it can
not be changed. Please be sure the name that is chosen is
the one that will be used in the future.
6. Click Save when done.
7. Go to Lock Editor tab in Lock/User Editor.
8. Left click to highlight the name of the lock and then click Edit
Lock.
9. Verify and/or adjust all other lock parameters. (See LockView
NTC/VTC Software Instruction Manual for complete
details.)
10. Click OK when done.
Manual Method
1. Login to LockView.
2. Go to Lock/User Editor; Lock Editor tab and click Add Lock.
3. Enter the required information: Lock Name; Lock Serial
Number and Setup Code (supplied on green sticker set as
Setup Cd).
**Once the Lock Name has been chosen in LockView, it can
not be changed. Please be sure the name that is chosen is
the one that will be used in the future.
4. Verify and/or adjust all other lock parameters and click OK.
(See LockView NTC/VTC Software Instruction Manual for
complete details on these options)
5. With the eLock in SETUP mode, connect the eLock via the
USB cable to the computer on which LockView is installed.
6. After 30 seconds, the lock will be updated in LockView. Click
Refresh to prompt the update.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.
200/300 Series VTC eLock — Instructions continued

7
200/300 Series — VTC eLock Instructions
200/300 Series VTC eLock — Manual Programming
Credential Menu
ADD CREDENTIAL
Note: There are two status levels; Supervisor and User. Each
eLock can hold any combination of up to 3,000 Supervisors
and Users.
Only Supervisors are allowed to ADD Users and Supervisors.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT.”
4. Highlight ADD CREDENTIAL and press “NEXT/SELECT.”
5. CREDENTIAL TO ADD will be displayed. Scan new credential
or enter new 4-14 digit PIN and Press “ENTER.”
6. Adding credential will be displayed.
7. Default status is User. To change status to Supervisor press
the +button.
8. The new User/Supervisor will be added to the next available
slot number. To change the slot number, press “UP” and then
+/- to move to next available slot; or use the numeric keypad
to enter the desired slot number and press “NEXT/SELECT.”
9. CREDENTIAL NAME ENTRY will appear. Press 2 - 9 for A - Z;
press 1 for -, ., +or _; press 0 for “space”; press and hold
0 - 9 for numbers. (Maximum number of allowed characters
is 14.)
10. Press “ENTER” when done. STORED will be displayed when
complete.
DELETE CREDENTIAL
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to DELETE Users and
Supervisors.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
4. Highlight DELETE CREDENTIAL and press “NEXT/SELECT”
5. Credential to Delete will be displayed. All of the occupied
slots along with the name (if one exists) will be listed. If
the status of the credential is a supervisor, an asterisk (*)
appears next to the slot number. Press “MENU” to re-sort
by slot number, alphabetically by name, or showing all
supervisors first.
6. Press ‘UP” / “DOWN” to scroll by line or +/- to scroll by
page to highlight credential to be deleted and press “NEXT/
SELECT.”
7. Press “UP” and “NEXT/SELECT” to delete. DELETED will be
displayed when complete.
8. Press “BACK/CANCEL” to return to CREDENTIAL MENU.
VIEW CREDENTIAL
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to VIEW Users and Supervisors.
1. Press “MENU” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
4. Highlight VIEW CREDENTIAL and press “NEXT/SELECT”
5. Credential to View will be displayed. All of the occupied slots
along with the name (if one exists) will be listed. If the status
of the credential is a supervisor, an asterisk (*) appears next
to the slot number. Press “MENU” to re-sort by slot number,
alphabetically by name, or showing all supervisors first.
6. Press “UP”/“DOWN” to scroll by line or +/- to scroll by page to
highlight credential to be viewed and press “NEXT/SELECT.”
7. Press “NEXT/SELECT” to display NAME, SLOT NUMBER, LAST
ACCESS ATTEMPT.
8. Press “DOWN” to display CREDENTIAL TYPE (KEYPAD, PROXCARD
or MAGSTRIPE CARD)
9. Press “DOWN” again to display the ACCESS SCHEDULE
(TIME AND DAY RESTRICTIONS AS SET IN LOCKVIEW).
10. Press “BACK/CANCEL” to return to CREDENTIAL MENU.
EDIT CREDENTIAL
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to EDIT Users and Supervisors.
1. Press “MENU” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
4. Highlight EDIT CREDENTIAL and press “NEXT/SELECT”
5. Credential to Edit will be displayed. All of the occupied slots
along with the name (if one exists) will be listed. If the status
of the credential is a supervisor, an asterisk (*) appears next
to the slot number. Press “MENU” to re-sort by slot number,
alphabetically by name, or showing all supervisors first.

200/300 Series — VTC eLock Instructions
8
200/300 Series VTC eLock — Manual Programming continued
6. Press ‘UP” / “DOWN” to scroll by line or +/- to scroll by page
to highlight credential to be edited.
7. Press “NEXT/SELECT” to edit highlighted credential
8. Press +/- to change Level (Supervisor/User); press “UP/
DOWN” to highlight 2nd PIN. To add a new or change an
existing 2nd PIN, enter a 4 - 14 digit number using the
numeric keypad. Press “ENTER” when done. Confirm the
new/changed PIN by entering it again when prompted. Press
“ENTER” when done.
9. Press “BACK/CANCEL” to return to CREDENTIAL MENU.
SET/EDIT YOUR 2nd PIN
Note: There are two status levels; Supervisor and User.
Only Supervisors are allowed to SET/EDIT YOUR 2nd PIN.
The steps below will make the logged in credential a Dual
Credential Supervisor requiring a 2nd PIN.
Follow the EDIT CREDENTIAL steps to add/change dual
credential status for other Supervisors or Users.
1. Press “MENU” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER”
3. Press “DOWN” button to highlight CREDENTIAL MENU and
press “NEXT/SELECT”
4. Highlight SET YOUR 2nd PIN and press “NEXT/SELECT.” (EDIT
YOUR 2nd PIN will appear if a second PIN credential already
exists)
5. Type new 2nd PIN will be displayed. Enter new 4 - 14 digit
PIN and press “NEXT/SELECT.”
6. Type 2nd PIN again will appear. Enter the 4 - 14 digit PIN
again and press “NEXT/SELECT.” NEW PIN SET will appear.
Display Formats
Using DISPLAY FORMATS, the following can be adjusted:
HOURS: AM/PM or 24 HOUR
M-F/DATE:
wMON-SUN; MM/DD/YY;
wMON-SUN; MMM D ‘YY;
wMON-SUN; DD-MM-YY;
wMON-SUN; DD-MMM-YY
wMON-SUN; YYYY-MM-DD
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight DISPLAY FORMATS and
press “NEXT/SELECT.”
4. DISPLAY FORMATTING will be displayed.
5. Press “UP”/“DOWN” buttons to select and +/- buttons to
adjust.
6. Press “NEXT/SELECT” when done.
Set Date/Time
Using SET DATE/TIME, the following can be adjusted:
SETUP TIME ZONE (INCLUDING AUTO DAYLIGHT SAVING)
SET DATE (MONTH, DAY, YEAR)
SET TIME (HOUR, MINUTE, AM/PM)
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight SET DATE/TIME and press
“NEXT/SELECT.”
4. DATE/TIME MENU will be displayed.
5. Press “UP”/“DOWN” to scroll and “NEXT/SELECT” to modify.
6. Press “UP”/“DOWN” buttons to select and +/- buttons to
adjust.
7. Press “NEXT/SELECT” when done.
8. Press “BACK/CANCEL” to return to main menu.
Network Test (if equipped)
Using NETWORK TEST the strength and quality of the eLock
connection to the network is displayed. The IP and MAC
addresses are also shown here.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight NETWORK TEST and press
“NEXT/SELECT.”
4. NET STATUS will be displayed as well as Str: & Qual:, IP
address and MAC address.
5. Press “CLEAR” to exit.
LCD Contrast
Using LCD CONTRAST, the LCD contrast can be adjusted:
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight LCD CONTRAST and press
“NEXT/SELECT.”

9
200/300 Series — VTC eLock Instructions
200/300 Series VTC eLock — Manual Programming continued
4. LCD Contrast will be displayed.
5. Enter 1 - 9 on numeric keypad or +/- buttons to adjust.
6. Press “NEXT/SELECT” when done.
7. Press “BACK/CANCEL” to return to main menu.
LCD Backlight
Using LCD BACKLIGHT the brightness of the display can be
adjusted.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight LCD BACKLIGHT and press
“NEXT/SELECT.”
4. LCD Backlight will be displayed.
5. Enter 0 - 9 on numeric keypad or +/- buttons to adjust.
(“0” = OFF)
6. Press “NEXT/SELECT” when done.
Set Beep Volume
Using SET BEEP VOLUME, the audible beep can be
adjusted.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and press
“ENTER.”
3. Press “DOWN” button to highlight SET BEEP VOLUME and
press “NEXT/SELECT.”
4. Beep Volume will be displayed.
5. Enter 0 - 9 on numeric keypad or +/- buttons to adjust.
(“0” = MUTE)
6. Press “NEXT/SELECT” when done.
7. Press “BACK/CANCEL” to return to main menu.
Reset Net Schedule
A PROPERLY CONFIGURED AND ENABLED NETWORK eLock
IS REQUIRED TO MAKE USE OF THIS FEATURE.
Only Supervisors are allowed to RESET NET SCHED.
Using RESET NET SCHED. the scheduled network check-in
time can be set.
1. Press “MENU.” LOGIN PLEASE will be displayed.
2. Scan valid credential or enter 4-14 digit PIN and Press
“ENTER.”
3. Press “DOWN” button to highlight RESET NET SCHED. and
press “NEXT/SELECT.”
4. NETWORK TIMING RESET will be displayed. The eLock will
follow the programmed or default check-in frequency from
this time of day forward.
For example:
Programmed Update Interval as set in LockView is 12 hours
(twice/day). The time of day was 10 a.m. when the eLock
was initialized.
Therefore, the eLock update time is 10 a.m. and 10 p.m. The
desired update time is 6 a.m. and 6 p.m.
Using the RESET NET SCHED. feature, the above steps should
be followed at 6 a.m. or 6 p.m.
Name of last credential on LCD
The name, time, day and date of the last credential to
successfully access the eLock appears at the bottom of the
reader display.

200/300 Series — VTC eLock Instructions
10
Setup Code
**In order to ensure the security of the application on
which the eLock will be installed, the setup code (supplied
on green sticker set as Setup Cd) must be kept in a safe
location.**
If required, the eLock can be placed in setup mode.
1. Press and Hold “CLEAR” on eLock keypad. ENTER SETUP
CODE will appear.
2. Enter the setup code (supplied on green sticker set as Setup
Cd) and press “ENTER”
3. SETUP CODE will appear in the upper left hand corner of the
eLock LCD. (The eLock will exit setup mode after 5 minutes of
inactivity). Press “CLEAR” on the eLock keypad to exit SETUP
mode. READY will be displayed in the upper left hand corner
LCD)
SETUP mode would be necessary in the event that:
1-- eLock should be added to the database in LockView.
2-- It became necessary to restore the original factory settings,
(FACTORY RESET); disable the Wi-Fi or Ethernet module,
(TURN OFF/ON NETWORK); or disable the eLock temperature
probe, (TURN OFF THERM).
Factory Reset
In the event that it becomes necessary to erase ALL
Supervisors/Users and log entries from the eLock and reset
all settings to the original factory defaults, a FACTORY RESET
may be performed.
WARNING: ONCE A FACTORY RESET IS PERFORMED, IT
CANNOT BE REVERSED.
1. Press and hold “CLEAR” on the keypad.
2. ENTER SETUP CODE will be displayed. Enter the set up code
and press “NEXT/SELECT.”
3. SETUP will be appear in the upper left hand corner of the
eLock LCD.
4. Press the “MENU” button.
5. Press “UP” button to highlight FACTORY RESET and press
“NEXT/SELECT.”
6. Press “UP” button to highlight FULL RESET.
7. Press and Hold “NEXT/SELECT” to reset.
8. Factory will appear in the upper left hand corner of the
eLock LCD. Note: whenever eLock is in factory mode, it is
considered unsecured.
Stand-alone & Networked eLock
Alarm States
The eLock has programmable ALARM/ALERT STATES.
1) Battery Low
(A properly configured and enabled network eLock is
required to make use of this feature.)
Battery Low can be programmed to send an alert(s) via
LockView’s Remote Alert Messaging if the eLock battery
power drops below a defined level.
Note: There is no audible alarm that can be triggered at the eLock,
however there is a yellow LED low battery indicator (LOW BATT) on the
eLock keypad.
(See LockView Manual for NOTIFIER explanation)
2) Door Ajar
(Door switch – NOT INCLUDED – must be installed and enabled
in order to make use of this feature)
Door Ajar is intended to trigger an alarm at the eLock if the
application door has been left opened.
After the programmed or default eLock latch open time has
expired, the Door Ajar timer begins. The Door Ajar timer is
programmable in LockView in one second increments. The
door ajar alarm will be triggered if this time expires before
the door switch closes.
The eLock will stop alarming after the door switch closes.
(See LockView Manual for NOTIFIER explanation)
3) Unauthorized Entry
(Door switch – NOT INCLUDED – must be installed and enabled
in order to make use of this feature)
Unauthorized Entry is intended to trigger an alarm at
the eLock in the event of an application “break-in.” The
Unauthorized Entry alarm will sound when the door switch
opens and the eLock latch bolt is in the extended position.
The eLock will stop alarming after a valid credential is
presented.
(See LockView Manual for NOTIFIER explanation)
200/300 Series VTC eLock — Manual Programming continued

11
200/300 Series — VTC eLock Instructions
4) Overdue Network Check-in
(A properly configured and enabled networked eLock is
required to make use of this feature)
Overdue Network Check-in can be programmed to send an
alert(s) via LockView’s Remote Alert Messaging if the eLock
is Xminutes past the programmed scheduled check in
time. The overdue time is programmable in LockView in one
minute increments. The Overdue Network Check-in alert will
be triggered if this time expires before the eLock checks-in
to the network.
Note: There is no audible alarm that can be triggered at the
eLock; however, NETWORK TEST can be used to determine
Wi-Fi strength and quality.
(See LockView Manual for NOTIFIER explanation)
200/300 Series VTC eLock — Manual Programming continued
qAdd, edit, view and delete users / supervisors
and their credentials
qAdd, edit and delete VTC eLocks®
qAssign access rights between users / supervisors
and VTC eLocks®in the database
qUSB or network connection*
qDownload, view, save, print, archive and delete
audit trails
qDual credential access available
qSet real time clock
qTime based access restrictions
qCreate user groups
qWindowsTM based
qSet up Escalating Notification System*
qView Compliance Dashboard*
LockView®software
LockView is a Registered Trademark of CompX International. Windows is a trademark of the Microsoft Corporation. Specifications may vary based on user application.
* requires network eLock

12
Notes
Part #: 332986000000 Copyright 2012 © CompX Security Products
Any companies and/or products referred to herein are marks or registered trademarks of their respective companies, owners and/or mark holders.
This manual suits for next models
1
Table of contents
Other Snap-On Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

CIAT
CIAT DYNACIAT LG Series instruction manual

Festo
Festo HGR A Series operating instructions

SMC Networks
SMC Networks MGP-XB24 Mounting instructions

probst
probst FSZ-M operating instructions

Zimmer
Zimmer DVR1000 Series Installation and operating instructions

fine
fine SMART FAC-5700 TC Series Operation manual