installation ManUal
LX95 commerciaL soLar Lighting FiXtUre
Revision 3.0
1.2STORAGEANDHANDLING:
If you wish to store the luminaire, the battery needs to be recharged before
storing for a period of 15 days or more in order to prevent damage to the
battery. The luminaire must be stored at 20°C room temperature.
Theluminaireshouldneverbemanipulatedwhenthebatteryisin-
side.Usethequickaccessdoortoremovethebatterybeforehan-
dling.
1.3DEEPDISCHARGEPROTECTION
This protection signicantly increases battery lifespan. This protection
also prevents permanent damage to the battery caused by very deep dis-
charges during cold weather. Whenthebatteryreachesa50%stateof
charge, the battery is automatically disconnected from the system
untilit’s stateofchargereaches 85% i.e. about 1 day of sunshine in
summer and about 4 days of sunshine in winter.
1.4PIRSENSORTIMEDELAYFEATURE ADJUSTMENT
Pleasebecareful,thetimedelaytrimpotisafragilecomponent.
The Time Delay (30 seconds to 30 minutes) adjustment trimpot is located
under the lens assembly. The trimpot is accessed easily. Gently unscrew
the lens assembly. Do not remove the thumbscrew collar; it holds the sen-
sorinplaceonthexture. Set the time delay to the desired setting. The
time delay can be set from 30 seconds (fully counterclockwise) to 30 min-
utes (fully clockwise). We recommend not to go over 5 minutes. The time
delay starts when no more presence is detected.
1.5DAY-NIGHTTRANSITION
Thextureusesthesolarpaneltodetectdayandnightperiods.Thenight
transition requires a very low brightness level for 5 continuous minutes.
This constraint prevents false night transitions. Avoid exposing the lumi-
nairetoanarticiallightsourcethatmaycausesynchronizationerrorsby
simulatingtheday.Ifthextureoperateserratically,makesurethesolar
module is not covered with debris or heavy snow. The luminaire auto-
matically corrects synchronization errors after 24 hours. The occupancy
sensor has its own photocell, which does not activate when the ambient
brightness is too high.
P.3/4