L
N
2
10 min
0.5 s
PROG.
NL
1
2
3
4
OFF
1 4
23
N
L
230 V 50 Hz
Blue
Brown
Green - Yellow
PREPROGRAMMING A CONTROL POINT
PAIRING
From the Application
“Help me by Somfy”
scan the QR code here
to find complete
setting instructions.
“Help me by Somfy”
available on stores
Short installation guide
UP DOWN
the drive is supplied in lower end limit position. The mushroom can therefore be used to set the upper end limit position.
A minimum of 3 rotations of the drive shaft is required between the lower end limit and the upper end limit.
Factory setting :
You can go
to the step
Control point is temporary
programmed for 10 minutes.
DIRECTION OF ROTATION
END LIMITS SETTING
Control point is completely
programmed.
SETTING THE UPPER END LIMIT
Ensure that the EVB is at least 15 cm below the new desired upper end limit.
Other setting like Tilting travel, Obstacle detection, Automatic adjustment and more are available from the “Help me by Somfy” application
USE
This drive does not require any maintenance operation
UP MYSTOPDOWN
5156397A
EN
J4 io Protect

New Node
5
1
2 s
OFF
2
5 - 15 s
ON
3
2 s
OFF
4
ON
5
7 s
PROG. x 2
DRIVE RESETTING
Apply the double cutout only for the end-product to be reset.
This reset deletes all programmed control points, all sensors, all end limit settings and resets the favourite (my) position for the drive.
INSTRUCTIONS TO BE RESPECTED
These instructions apply to all J4 io Protect drive, the different versions of which are available in the current catalogue.
FIELD OF APPLICATION
The J4 drives are designed to drive all types of tiltable venetian blinds.
The J4 drives are designed to motorise all types of:
–
Tiltable venetian blinds which bottom lath can be lifted at least by 4cm when an upward force of 150N is applied to the bottom lath positioned at 16cm from the fully extended position.
LIABILITY
Please read these instructions carefully before
installing and using the drive. In addition to
following the instructions given in this guide, the
instructions detailed in the attached Safety
instructions document must also be observed.
The drive must be installed by a motorisation and
home automation professional, according to
instructions from Somfy and the regulations
applicable in the country in which it is
commissioned.
It is prohibited to use the drive outside the field of
application described above. Such use, and any
failure to comply with the instructions given in this
guide and in the attached Safety instructions
document, absolves Somfy of any liability and
invalidates the warranty.
The installer must inform its customers of the
operating and maintenance conditions for the drive
and must provide them with the instructions for use
and maintenance, and the attached Safety
instructions document, after installing the drive.
Any After-Sales Service operation on the drive
must be performed by a motorisation and home
automation professional.
If in doubt when installing the drive, or to obtain
additional information, contact a Somfy adviser or
go to the website www.somfy.com.
SAFETY INSTRUCTIONS FOR WIRING
Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.
If the drive is used outdoors, and if the power supply cable is a type H05-VVF cable, the cable should
be installed in a UV-resistant duct, e.g. under a gland.
Leave the drive power supply cable accessible: it must be possible to replace it easily.
Always make a loop in the power supply cable to prevent water entering the drive.
SPECIFIC INSTRUCTIONS
Do not connect the drive to an isolating transformer.
Do not use mains disconnection devices in conjunction with a drive.
Use only mechanical switches or electro-mechanical switches (ex: relays) to control drives.
The contacts of the relays must not be bypassed by capacitors.
In user mode, do not use electric switches allowing simultaneous Up or Down contact.
The drive must not be driven by a solid-state relay or triac relay.
Always refer to the control system instructions to do the proper wiring.
For control systems using an «automatic running time recognition procedure», please
consider the recommendations given by the producer of the controller: the N wire of the
controller has to be connected to the N wire of each drive.
Continuous orders of at least 200 ms must be sent to the drive to ensure proper execution.
Intervals between “Down” and “Up” orders must be at least 500 ms.
The drive can be wired in parallel. In this case take in consideration the maximal load of the
switch/controller used (starting current peak of the drive: 9 A in the first 3 ms).
Phases and neutrals of each drive must be connected respectively as shown below:
N
L
M M M
The drive must be installed by a professionally qualified person (electrical specialist according to DIN VDE 1000-10) for drives and automations in the building services sector in accordance with the Somfy
instructions and the applicable regulations in the country of commissioning.
Radio frequency
Frequency bands and Maximum power used
Power supply
868-870 MHz io-homecontrol® two-way Tri-band.
868.000 MHz - 868.600 MHz e.r.p. <25 mW
868.700 MHz - 869.200 MHz e.r.p. <25 mW
869.700 MHz - 870.000 MHz e.r.p. <25 mW
230 V ~ 50 Hz
SOMFY ACTIVITES SA, 74300 CLUSES FRANCE as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and used as intended according
to these instructions, is in compliance with the essential requirements of the applicable European Directives and in particular of the Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU. The
full text of the EU declaration of conformity is available at www.somfy.com/ce. Philippe Geoffroy, Approval manager, acting on behalf of Activity director, Cluses, 05/2021
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved collection point for recycling.
Images are not contractually binding - 100% recycled paper - Copyright © 2021. All rights reserved. SOMFY ACTIVITES SA, Société Anonyme, capital 35.000.000 Euros, RCS Annecy, 303.970.230 - 05/2021
SOMFY ACTIVITES SA 50 avenue du Nouveau Monde, 74300 CLUSES FRANCE www.somfy.com
Other manuals for J4 io
4
Table of contents
Other SOMFY Protection Device manuals
Popular Protection Device manuals by other brands

Silverline
Silverline MICE & RAT FREE 25 manual

3M
3M DBI-SALA 3400862 instruction manual

Scorpion Power System
Scorpion Power System Tribunus 06-120A ESC user guide

Burg Wächter
Burg Wächter TSE 5103 operating instructions

Endress+Hauser
Endress+Hauser FQG61 Series Safety instructions

MDR Electronics
MDR Electronics MX-2503 manual