Soto SOTO-G5 User manual

Operation Manual
SOTO-G5
MEDICAL AIR PURIFIER
Before operating the system,
please read this manual
thoroughly, and retain it for
future reference.
Top-Grade Air Purifier

This is Soto
If you have the opportunity to
experience SOTO air purifiers, please
remember that they are designed
with our dreams to meet your
expectations...

Contents
04
05
06
07
08
09
10-13
14-17
18
19
Consumer Limited Warranty
Safety Precautions
How it Works
Features and Specifications
Part Name
Installation
Operation
Care and Maintenance
Troubleshooting
Filter Maintenance Schedule

04
Consumer Limited Warranty
Congratulations on your investment
This warranty shall not apply if:
SOTO warrants that this product is free, under normal use and maintenance, from any defects in material
and workmanship. If any such defects should be found in this product within the applicable warranty
period. SOTO shall, at its option, repair or replace the product as specified herein.
SOTO will repair or replace, free of charge, to the original purchaser, any part that is found to be defective
in material or workmanship within one (1) year of the date of purchase. This limited warranty does not cover
there placement of expendable or consumable parts such as filters or UV lamps, and other parts subject to
normal wear unless they are defective in material or workmanship.
1. Any defects caused or repairs required because of abusive operation, negligence, accident, improper installation
or inappropriate use as outlined in the operation manual.
2. Any product tampered with modified, adjusted or repaired by any party other than SOTO.
3. Damaged caused or repairs because of the use with items not specified or approved by SOTO.
4. Any damage caused by external or environmental conditions (such as a fire or an earthquake), including but not
limited to the use of voltage other than indicated on the product.
5. The content on the warranty card is inconsistent with the product, or there is no valid evidence to prove that the
defective product is provided by SOTO.
SOTO gives you the following limited warranty for this product only if it was originally purchased from
SOTO or from an authorized dealer.

05
To reduce the risk of electrical shock, fire or injury to person(s) read the following:
Running Environment Cautions
Unit Operation
Use only a 220~240-volt outlet with grounding wire receptacle.
Do not use the unit in an enclosed space where oxygen, flammable, explosive or toxic vapors are given off
by oil base paint, paint thinner, some moth proofing substances. It may cause explosion or fire.
The product cannot be used in high-temperature, wet or watery places. Best working condition is 0-40
0
C
and relative humidity of < 75%.
Do not operate the unit without filters. Make sure remove plastic packaging from all the filters before operation.
Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loose.
When removing the power plug, always hold the plug and never pull by the cord.
Do not handle plug or appliance with wet hands. Electrical shock or fire from short circuit may occur.
To avoid causing fire do not attempt to disassemble the unit - only certified technicians should do this.
Stop the unit and unplug the power when maintenance.
Do not insert fingers or foreign objects into the intake or air outlet.
Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
Do not use the unit near or on hot objects, such as range or where it may be exposed to steam.
Do not wipe the outside, inside or any parts of the unit with flammable substances, it may cause fire!
Do not wash or reuse the Pre-filter, HEPA fillter and Carbon filter.
Always hold the unit body when moving it. Holding the back panel when carrying may cause it to detach,
and result in bodily harm.
Photo catalytic is permanent, never needs replacing. When there is dust on it, clean the dust off using a
vacuum cleaner dusting brush. Do not wash it in water.
Safety Precautions

1. The Pre-filter traps large dust particles.
2. The UV lamps kill bacteria and viral microorganisms such as influenza,
TB and Legionnaire's Disease as well as other harmful contaminants.
3. When UV light hits the photo catalytic filter, it creates e- and h+,
which have an excellent effect in the decomposition of odors.
4. The two-stage electrostatic adsorption device (Electronic cell) captures
airborne particles, as small as 0.01 microns.
5. The high efficiency HEPA filter removes microscopic particles in the air.
6. The activated carbon filter will absorb odors and gases.
7. The unit also generates negative ions that freshens the room air.
The air purifier functions as an air cleaner by helping to disinfect airborne microorganisms and removing
particulates from the air. The DC fan of the unit draw air through the bottom (Intake) of the unit. Then it passes
through the Pre-filter, UV lamp + Photo catalytic filter, Electronic cell (Electrostatic adsorption device), HEPA filter
and Activated carbon filter. The purified air is then released through the outlet on the top of the unit. The
Negative Ion Generators near the air outlet releases revitalizing negative ions into the air to refresh the air.
The air is cleansed in seven stages.
06
How it Works
1. The UV radiation destroys the DNA structure of bacteria and kills
pathogenic microorganisms.
2. The UV ray wavelength is 254 nm, and the average intensity of UV
ray irradiation is 186μW/cm2at a position 1m below the UV lamps.
Sterilization Factor

The unit has a Pre-filter (traps large dust particles), two-stage Electronic cell, HEPA Filter (remove particles),
Activated Carbon Filter (absorbs odors and gases), UV Lamp + Photo catalytic Nano-TiO2filter (killing airborne
pathogen) and Negative Ion generator (revitalize and refresh the air).
Model
Power Requirement
Rated Power
Negative Ion
UV Lamp
Fuse
Dimensions
Weight
SOTO-G5
220-240V~, 50/60Hz
208W
3x106/cm³
2x24W
250V, 3A
48cm x 48cm x H136.5cm
53kg
1. The odor and particle sensor can let the unit automatically select the appropriate fan speed depending on the
air quality detected.
2. The G5 can be operated completely with the wave of your hand, making it suitable in medical settings
to avoid cross contamination.
3. The indicator lights tell you when to replace the Pre-filter, HEPA filter and the Activated carbon filter or the
UV lamp.
4. When the filters need to be replaced, simply open the back panel and pull out the filters and replace a new
one in. No screws, hooks or tools are required.
07
Features and Specifications

Part Name
-01
-04
-05
-06
-07
-11
-12
-13
-14
16
-15
-17
-18
-19
-08
-09
-10
08
-03
-02
01- Unit Body
02- Front Panel
03- Back Panel
04- Fan motor
05- Main Circuit Board
06- UV Ballast
07- LED Display Board
08- Ion Generator
09- PC Display Panel
10- Pre-filter
11- Photo Catalytic Filter
12- UV Lamp
13- Electronic Cell
14- HEPA Filter
15- Activate Carbon Filter
16- Power supply
17- Handle
18- Back Panel Key
19- Castors

09
Installation
1. This product is used for indoor sterilization in unmanned environment. It cannot to be used in the
environment with inflammable and explosive gases.
2. This product satisfying the requirements of the China "General Hygienic Requirements for Air Sterilizer”.
Turn on the unit, UV lamp and negative ion on, operate it for 60 minutes at high speed in a 100m³ space.
Three repeated tests have all achieved the natural bacteria extinction rate of more than 90% for indoor air.
Applicable places and Operation
1. Before operating the unit, open the back panel and take out the pre-filter, HEPA filter and Carbon filter,
then remove plastic packaging from all the filters.
2. Plug the power cord of the unit into a nearby power outlet.
3. The unit has a remote control. Put the batteries into the remote control before using it.
Before operation
1. Power supply condition: Use only a 220-240 volt outlet with grounding wire receptacle.
2. Environmental conditions:Temperature:0℃~40℃; Relative humidity:<75%.
3. The unit should be installed in an indoor area with less personnel activities, and the unit should be set up
against the wall.

10
Button Operation
1 POWER Button
- Turns the unit On and Off.
- Hold the button for 2 seconds, the “ ” indicator light will
light up with beeping. In this mode, the panel is locked.
If you want to return to the default mode, do the reverse.
2 SPEED Button
When this button is pressed the airflow rate changes as
shown below: L … M… H ... AUTO.......
3 TIMER Button
Press this button to select the time for operation. The timer
setting switches as shown: 1 -- 2 -- 4 -- C (timer cycle
function) -- cancel timing.
4 NEG.ION Button
Turns Negative Ions on and off.
5 UV LAMP Button
When the button is pressed, it will turn off the UV lamps,
pressing again will turn on the UV light.
6 NIGHT Button
When pressed, all the indicator lights on the display panel
will go out.
AUTO
TVOC
°C
µg/
m³
RH
%
ON
OFF
EH C
14 523 6
Operation 1

11
Display Indicator Lights
1 SPEED indicator light: When the power is on, the
indicator light will light up, select the speed by
pressing the SPEED button.
2 AUTO MODE indicator light: When the indicator is
lighting up, the unit is at Auto mode.
3 TIMER indicator light: When the TIMER button
pressed, the indicator light will light up.
4 SCHEDULED OPERATION TIMER indicator light:
- Displays the current clock time when the unit has
no time set.
- When the scheduled operation time is set, the
“OFF” indicator will light up under the running state
and display the shutdown time. When in the power
off state, the “ON” indicator will light up and
display the power on time.
5 PM2.5 display: Real-time display the indoor
PM2.5 concentration (μg/m³).
6 Indoor TVOC pollution level display
7 Indoor Temperature display
8 Indoor Humidity display
9 CHECK indicator light: When the indicator light
flashes with beeping, please contact customer
service.
AUTO
TVOC
°C
µg/
m³
RH
%
ON
OFF
EH C
12
5
4
3
6
7
8
911
12 13
Operation 2

12
Gesture Sensing Operation
11 LOCK FUNCTION indicator light: In this mode, all the buttons will not work.
12 CLEAN or REPLACE Filters indicator light
- When the“ ” indicator light flashes, the Pre-filter needs to be replaced and the electronic cell needs to be washed.
- When the“ ” indicator light flashes, the HEPA filter needs to be replaced.
- When the“ ” indicator light flashes, the Carbon filter needs to be replaced.
13 Pollutant level display (See the chart) The different colors indicate the air quality:
Blue=Good, Orange=Unhealthy, Red=Hazardous
Use your hand to wave over the sensor, this waving
motion turns the unit on & off, and can also adjust the fan speed.
Hover & hold your hand over the sensor for 2 seconds and this will lock
the unit at the desired speed. This will prevent accidental or unwanted
speed changes.
Indicator Color
Blue
Orange
Red
PM2.5
≤75μg/m³
76~150μg/m³
>150μg/m³
TVOC Level
Speed
L
M
H
~
~
E
H
C
Operation 3
Display Indicator Lights

13
Operation 4
Remote Control Operation
8
1
3
4
5
2
7
6
1 Power (ON/OFF) Button
The unit will start operating when the POWER button is pressed.
Pressing the button again will stop operation.
2 Scheduled operation time Buttons
a. The first time press the “TIME” button, the digital clock on the display
panel is flashes, calibrate the current time by pressing the "+" or "-"
buttons.Then press the “ ” button, the minute display starts flashing.
Also calibrate the current minute by pressing the “+” or “-” buttons.
b. Press the “TIME” button a second time, the "ON" indicator light on the
display panel is light on. At this point, press the "+" or “-” buttons to set
the start time of the unit through the same time setting method.
c. Press the “TIME” button a third time, the “OFF” indicator light on the
display panel is light on. At this point, according to the same time setting
method, press the "+" or “-” buttons to set the unit’s shutdown time.
d. Press the “ ” button to confirm the above time setting. At this time,
the unit is turned on and off at the set time every day.
3 SPEED Button
The fan speed can be switched among L- M- H- Auto settings.
4 NIGHT Button
When pressed, all the indicator lights on the display panel will go out.
5 UV-C+ LAMP Button: Turns UV-C+ lights on and off.
6 NEG.ION Button: Turns Negative Ions on and off.
7 TIMER Button
The set time switches every time the button is pressed as shown below:1hr - 2hr - 4hr - Cycle - Cancel.
8 RESET Button
Pressing the reset button 3 times will reset the replacement indicator lights.

14
When the “ ” indicator light on the control panel flashes, the Pre-filter needs to be replaced.
Wipe with a dry, soft cloth for stubborn stains or dirt. Do not use volatile fluids, Benzene, paint thinner, polishing
powder, this may damage the surface. Do not use detergents, detergent ingredients may damage the unit.
Warning
To maintain optimum performance of this air purifier, the Pre-filter, the HEPA filter, the Activated carbon
filter and the UV-C+ lamp need to be replaced when the indicator lights are flashing.
When maintenance on the unit, be sure to unplug the power cord, and never handle the plug with wet hands.
If so, electrical shock and bodily injury may occur as a result.
Replacing the pre-filter
Main unit
1. Stop the operation and unplug the unit.
2. Rotate the door lock and pull the back panel toward to you then take off
the back panel.
3. Gently pull out the bottom pre-filter.
4. After replacing the pre-filter, hold the “ ” button 3 seconds to reset
the time for the pre-filter.
E
E
DO NOT reuse or clean the pre-filter with liquid, especially
alcohol, gasoline, paint thinner, etc. It may cause fire!
Care and Maintenance 1

15
When the “ ” indicator light on the control panel flashes, the Electronic cell needs to be cleaned.
Cleaning the electronic cell
Remove the electronic cell
1. Stop the operation and unplug the unit. Take off the back panel.
2. Hold the Electronic cell’s handle, pull it toward to you.
Cleaning the electronic cell
1. Use a large enough container, such as a laundry tub or trash container.
Dissolve detergent in warm water to cover the cell. After the detergent
has completely dissolved, place the cell in the container. Allow the cell
to soak for 15~30 minutes and rinse with clean water.
2. Dry the cell thoroughly with heat gun before reinstalling.
3. After cleaning the Electronic cell, hold the “ ” button 3 seconds or
press the reset button on the remote control to reset the time for the cell.
Warning
If the air quality is extremely poor and the cell is dirty, you may clean the cell before the indicator light flashes.
DO NOT clean the cell with alcohol, gasoline, paint thinner or other flammable substances. It may cause fire!
Before Remove the electronic cell, stop the operation and unplug the unit.
DO NOT reinstall the cell until it is completely dry. If the“ ” indicator light on the control panel flashes,
then the cell may still be wet.
Be careful not to snag or cut the ionizing wire. If the unit is operated with the ionizing wire cut, there will be
no dust collection.
E
E
Care and Maintenance 2

16
When the “ ” indicator light on the control panel flashes, the HEPA filter needs to be replaced.
When the “ ” indicator light on the control panel flashes, the Carbon filter needs to be replaced.
1. Stop the operation and unplug the unit. Take off the back panel. (See P14 replacing the pre-filter)
2. Hold the HEPA filter’s handle, pull it toward to you, then pull out the HEPA filter.
3. Hold the carbon filter’s handle, pull it toward to you, then pull out the Activated carbon filter.
Replacing the HEPA filter and the Carbon filter
Warning
DO NOT reuse or clean the Pre-filter, HEPA filter and the carbon filter.
DO NOT clean the Pre-filter, HEPA filter and the carbon filter with liquid, especially alcohol, gasoline,
paint thinner, etc. It may cause fire!
Remove plastic packaging from the
Pre-filter, HEPA filter and the carbon
filter before operation.
After replacing the filters, hold the
flashing indicator button 3 seconds or
press the reset button on the remote
control to reset the time for the filters.
Note
Take out the HEPA filter
Take out the Activated carbon filter
H
C
Care and Maintenance 3

17
处理方法
When the “ ” indicator light on the control panel flashes, it is time to replace the UV lamps.
1. Stop the operation and unplug the unit. Take off the back panel. (See P14 replacing the pre-filter)
2. Pull it toward to you and take off the photo catalytic filter.
3. Hold the UV lamp, pull it up and remove it from UV lamp holder.
4. After replacing the UV lamps, hold the “ ”button 3 seconds to reset the time for the UV lamps.
Replacing UV Lamps
Photo catalytic filter
Photo catalytic filter is permanent, never needs replacing. When there is dust on it, clean the dust off using
a vacuum cleaner dusting brush. Donot wash it in water.
Never look directly at UV lamps.
Direct exposure to germicidal light
can cause temporary or chronic
damage to your eyesight, or even
blindness.
Always unplug the unit before
servicing or replacing the UV lamps.
1. Remove the UV lamp
blocker.
2. Hold the UV lamp, pull it
toward and remove it
from UV lamp holder.
Care and Maintenance 4
Warning

18
Troubleshooting
Power failure?
Power plug disconnected?
Is the fuse brunt?
Back panel open or interlock switch
failure?
Is the“ ” light flashing?
There is too much dust on the
electronic cell?
There is too much dust on the
pre-filter, HEPA filter or carbon filter?
The air inlet or outlet blocked?
Check other electrical appliances.
Make sure to insert the plus.
Replace the FUSE with new one.
Install the back panel properly and
check the interlock switch.
The cell may be wet after cleaning. Dry it
thoroughly. If not, call the customer service.
The unit does not operate
When functions do not
work properly
Wash it and dry completely before
reinstalling it.
Replace the pre-filter, HEPA filter or the
carbon filter.
Get rid of foreign materials around
the inlet or outlet.
Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by
reviewing the following guide. All other servicing should be done by a SOTO authorized service center.
What to check MeasureCase

Filter Maintenance Schedule
19
Pre-filter Replace Reminder
Electronic Cell Wash Reminder
Year
J
F
M
A
M
J
J
A
S
O
N
D
Year
J
F
M
A
M
J
J
A
S
O
N
D

SOTO Air Purification Technology (Langfang) Co., Ltd.
Add: Certification Industrial Park, Dachang High and
New Technology Development Zone, Langfang City,
Hebei Province, China
Tel: 400-626-8883
Web: www.sotoairpurifier.com
Table of contents
Other Soto Air Cleaner manuals