Install Instructions For:
Motion Sensor
1.435.647.9555
|
800.647.TUBE
|
www.soundtube.com
FP Series
FP Series
FP Series
Do not spec or install speaker near support beam, ventilation
duct or other structure that may interfere with speaker function
or dispersion.
Warning Warning
SoundTube speakers must be installed by a professional audio
installer/contractor. For safety and for optimum audio performance,
installer must follow all directions issued by SoundTube Entertainment.
© 2005 SoundTube Entertainment, Inc. All rights reserved. PN INS-FP6-MS REV 01.12.06
Dome Clamp
FP Speaker Pod
Motion Sensor
lens (narrow)
Motion Sensor
lens (wide)
Motion Sensor
Motion Sensor
Pod Cover
Motion Sensor Accessory Contents
1 FP Pod with wide lens
1 Narrow lens
(Optional, included)
(Standard)
The FP pod comes with the motion sensor lens preset to a wide angle and will trigger audio
activation from movement beyond the diameter of the dome. For applications with a narrow motion
sensor angle, follow these instructions. The narrow motion sensor lens will trigger audio activation
only when someone is standing directly underneath the dome.
ATTENTION
2. Remove motion sensor
pod cover.
3. Remove motion sensor lens. 4. Place narrow lens into pod
cover. Make sure lens is flush
with outside of pod cover.
Align the flat side of the lens w/
the flat side of the pod cover.
5. Place pod cover back on
FP unit.
6. Complete.
Install Instructions For:
To adjust the sensor from wide angle to narrow angle:
Motion Sensor
1.435.647.9555
|
800.647.TUBE
|
www.soundtube.com
FP Series
FP Series
FP Series
1. Unpack FP speaker pod
and FP Dome.
Orange White /
Orange
Blue White (unused)
Green (unused)
Brown White /
Brown
White/Green Signal wire
for 5 Volt ttl signal
Power supply and voltage sensor control
not included.
1. Attach the +12 V from the power supply to the
Orange white and orange wire pair.
2. Attach the ground from the power supply to the brown
white and brown wire pair.
3. Attach the ground from the voltage sensor controller to
the brown and white wire pair also.
4. Attach the signal wire to the white/green single wire.
5 Volt ttl signal (White/Green Signal wire)
• 0 Volts = motion detected
• 5 Volts = no motion detected
• The green and blue/white
wires are unused.
1k to 12 Volt pullup (Blue Signal wire)
• 12 Volts = motion detected
• 0 Volts = no motion detected
• The green and blue/white
wires are unused.
Wiring Diagram for Motion Sensor
Power Source
Cat V Wire From Pod
Voltage Sensor Controller
Blue Signal wire for
1k to 12 Volt pullup
Signal wire
Ground
Ground
Positive
(not included)
(not included)
SD-25 Audio Repeater
Gilderfluke & Company Burbank, califorina
Power
9-24 VDC
Line out
Left
Line out
right
Speakers
Left Right
Power
9-24 vdc
Running
status
Inputs
AB
Black Spk
Red Spk
Green Spk
White spk
Brown
White Brown
Cat V Pair
Orange
White Orange
Cat V Pair
Jumper wire
Pin 5 to 10
Blue
Cat V (Signal)
12 VDC
Power
supply
Install Instructions For:
SoundTube/Gilderfluke SD-25
FP6030-M FP6020-M Wiring diagram
1.435.647.9555 | 800.647.TUBE | www.soundtube.com
FP SeriesFP Series
Notes
1- 12 VDC is the maximum power
input from the power supply if using
soundtube motion sensor
2- If more volume is needed the SD-25
can be bridged and run in mono
mode. Internal jumpers need to be
set for this mode. Please see Sd-25
configuration & installation
instructions.
3- For operating and playback modes
please see SD-25 installation sheet.

This manual suits for next models

1

Popular Security Sensor manuals by other brands

Maxim RKI GX-6000 quick start guide

Maxim

Maxim RKI GX-6000 quick start guide

PCB Piezotronics M108A04 Installation and operating manual

PCB Piezotronics

PCB Piezotronics M108A04 Installation and operating manual

Siemens ADM-Q12 manual

Siemens

Siemens ADM-Q12 manual

ADT Ademco 5898 quick start guide

ADT

ADT Ademco 5898 quick start guide

Siemens FDB181C product manual

Siemens

Siemens FDB181C product manual

YUSHI YUT-28 Series manual

YUSHI

YUSHI YUT-28 Series manual

EpiSensor ZDI-20 user guide

EpiSensor

EpiSensor ZDI-20 user guide

Olimpia electronics BS-272 introduction

Olimpia electronics

Olimpia electronics BS-272 introduction

Baolong TMSS6A4 Operation manual

Baolong

Baolong TMSS6A4 Operation manual

Defender LL6170 owner's manual

Defender

Defender LL6170 owner's manual

Nortek Gocontrol WF00Z-1 instructions

Nortek

Nortek Gocontrol WF00Z-1 instructions

ETC Echo Dual Tech installation guide

ETC

ETC Echo Dual Tech installation guide

schmersal RSS 36-D-ST5 manual

schmersal

schmersal RSS 36-D-ST5 manual

RKI Instruments 35-3001-06-01 Operator's manual

RKI Instruments

RKI Instruments 35-3001-06-01 Operator's manual

Johnson Controls LC-203 quick start guide

Johnson Controls

Johnson Controls LC-203 quick start guide

YOKOGAWA TB820D user manual

YOKOGAWA

YOKOGAWA TB820D user manual

AJAX FireProtect 2 (Heat) Jeweller manual

AJAX

AJAX FireProtect 2 (Heat) Jeweller manual

Mier DA-500 installation manual

Mier

Mier DA-500 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.