Mier DA-500 User manual

DA-500 Drive-Alert Installation Manual
1 Sensor(s) buried 6-8 inches deep in PVC
detect(s) vehicle(s) entering a monitored area
2 A control panel receives a signal from the
sensor and triggers an alert-whistle inside the
control panel
3 Add a remote chime in the front room to alert
those on the rst oor
4 Add another chime in the basement to alert
those downstairs
5 Add a third chime in an upstairs bedroom to
alert those upstairs
6 Add a wireless or hard-wired timer controlled
light kit to turn on outdoor ood lights, indoor
lights and/or lamps to warn strangers or
welcome friends
7 Attach video surveillance to record activity
and display the driveway on a monitor inside
8 Add a repeater to send the signal another 1000
feet to trigger alerts in out buildings, or add a
DA-660 booster-antenna for buildings up to
8/10-mile away from the control panel
9 Activate signs, gates or other equipment
mp0100323
05/2021
11
2, 62, 6 33
44
55
77
THE BASICS
MORE OPTIONS
Cover
1 Introduction to the DA-500 and Accessories
2-3 Quick Installation Guide
4 Operation and Adjustment Instructions
5-7 Using the DA-500 to control chimes, lights, etc.
8 Accessories
9 Frequently Asked Questions
10 Troubleshooting Guide
11 Technical Support and Warranty Information

1
Model DA-500 Information and Most Common Accessories
Drive-Alerts are perfect for use in residential driveways, on farms, at drive-up windows,
in remote locations, and to protect valuable assets and equipment such as tractors or
construction vehicles. The Drive-Alert will detect a vehicle approaching, or whenever a
vehicle or metal equipment is moved.
Drive-Alerts detect metal which contain iron. It will not detect copper or aluminum.
The Drive-Alert’s method of operation is to sense the change in the magnetic eld. This
eld is always present, and is disrupted when a metal object moves through it.
The key element in the Drive-Alert installation is to locate the sensor/probe in the area
where you wish to detect this change. The usual installation is near the entrance of a
driveway, but located far enough away from roads or streets so as not to detect trafc.
Moving ferrous (iron) metal trips the sensor. Larger metal objects are detected easier
than smaller. Faster moving metal objects are detected easier than slower. Metal moving
nearer the probe is detected easier than metal moving farther away. These are the three
factors which determine the system’s range of detection. Therefore, trucks traveling 65
mph can be detected up to 50 feet; cars moving 5 mph up to 12 feet.
The Control Panel houses the electronics which allows the Drive-Alert to function. It also
contains an annunciator, and the terminal strip permits the attachment of the probe as
well as accessories or other devices. Adding a DA-500LKA Accessory adds even more
extra terminals for additional devices.
Longer lengths of cable are available. Simply order a DA-500CP (control panel only)
and a DA-051-___ where you ll in the blanks for the amount of cable needed in 50-foot
increments. Ex: DA-051-250 is a sensor with 250 feet.
A Hard-Wired DA-655 Chime with Volume is the most popular accessory for the
DA-500, and is HIGHLY recommended for all business, drive-up window, and high-
trafc areas where a DA-500 is used. The chime is far more pleasant than the standard
whistle inside the DA-500 Control Panel, and the volume control makes it far more
versatile.
The DA-505 and DA-505W Hard-Wired Timer Control units are housed in a separate
box and attached by wires to the terminal strip on the DA-500 Control Panel. This Timer
Control turns on lights for an adjustable period when a vehicle is detected.
The Hard-Wired DA-052V is and additional alert whistle accessory.
Wireless chimes are available with the DA-066MP Chime Transmitter which easily hooks
up to the contacts on a DA-500 and triggers DA-078 Wireless Chimes
Wireless light control is available with the DA-606LK with timer control.
Includes a DA-500CP Control Panel, Sensor, 100
feet of cable and UL Listed Power Supply
DA-505 and DA-505W Timer Control
DA-655 Chime with Volume
DA-066MP Wireless Chime Transmitter and the
DA-078 Wireless Chimes up to 100 feet away
DA-606LK Wireless Light Kit
DA-051-___ Probe with cable
DA-500LKA Additional Contacts
DA-500 Kit Contents:
• Solid-state Master Control Panel with Red LED power-on indicator
• Electronic whistle with “on-off” switch
• 100 feet of two-conductor shielded direct burial cable; other lengths available
• Weatherproof sensor
• SPDT relay output available
• UL Listed switching mode power supply, isolated from ground, with input voltage of
100 to 240 50/60HZ, which provides better lightening rejection. Output regulation
of 24VDC +/- 0.5A with output short circuit protection with current limit until fault
is cleared.
DA-REPEATER to signal DA-100CP Wireless
Chimes up to 1000 feet away, or up to 8/10-mile
away if using a DA-660 Booster Antenna
Accessories
DA-500 Kit

2
Installation page 1 of 2
The Control Panel is generally located in a closet, utility room, or garage. 120VAC power outlet must be available. If the only alert used
is the one contained within the control panel, the panel must be located where users can easily hear the “whistle.” Accessory chimes are
available. The control panel is not suitable for outdoor installation. The ease of routing the three-wire cable from the sensing probe should
be considered when deciding the location of the panel. The control panel is usually attached to the wall.
Improper installation is the No. 1 reason for system malfunction. Please use caution when installing the sensing probe to assure a properly
operating Drive-Alert.
The probe’s sensor is a coil of wire wrapped around an iron rod. Its DC resistance is 700-1100 ohms. The red and black wires connect to
the coil. It is encapsulated in epoxy to protect it from physical damage and moisture.
DO NOT CUT OR NICK THE CABLE JACKET!
If moisture enters, false alarms will be the result!
Mier HIGHLY recommends burying the cable within 1/2-inch PVC pipe for added protection to the cable.
The cable is made with an extra thick outer cover. There is a foil wrapper surrounding the red and black wires. There is a silver (bare) wire
in the foil. False alarms will occur if moisture gets into the foil wrapper. Nicks in the outer cover and improper splices allow moisture to
enter the cable. As moisture enters the cable, the resistance decreases. Resistance between the red or black wire to the shield wire must be
innite. (Use meter with ability to read resistance above 20 million megaohms).
The ideal installation is without any splices. The use of cable other than that which is designed for the Drive-Alert is undesirable and voids
the warranty. Improper splices and unsuitable cable are major causes of false alarms. If splicing is unavoidable, splice the cable using Mier’s
DA-054 Splice Kit, or equivalent.
The sensing probe does not know if it is in or out of the ground, but it must remain absolutely motionless. Most sensors and the direct burial
cable are buried 6 to 8 inches deep and parallel to the driveway. IT IS HIGHLY RECOMMENDED the sensor and the cable be buried in
PVC pipe to protect them over time from rocks migrating up or down in the ground, or landscaping mishaps.
The probe responds to changes in the magnetic eld around it. The signal produced by the coil is a few micro volts for a fraction of a
second. The probe and cable must not be within 20 feet of electric wires because they have changing magnetic elds of their own. Never
bury the sensor in the same trench with other electrical wires, including telephone wires and wires for lights, bells, etc.
The usual installation of the sensing probe is parallel to an already existing driveway. In this case, the sensor probe and cable can be buried
6 to 8 inches deep below the grass line, recommended in conduit. However, if vehicles are going to travel directly over the probe and
cable, they should be buried deeper (see next paragraph).
The burial of the probe is ideal in the center of the area being monitored, but often is not practical. If a new driveway is being put in, the
sensing probe could be buried a minimum of 12-24 inches deep. The sensor and cable should also be protected whenever vehicles move
over it.
You may wish to place a sensing probe atop the ground in the general area of where you wish to bury it, and connect the cable to the
control panel. **This will allow you to TEST the system in application BEFORE nal installation.** It would be acceptable to leave the
sensing probe and cable above the ground for a couple of days, but make certain it is not damaged during this period, and that it is held in
place so it will not move. This method should not be used permanently. See OPERATIONS INSTRUCTIONS for adjustments which may be
necessary.
The sensing probe may be placed up to 5,000 feet from the Control Panel. Up to 3 sensing probes can be attached to one panel, but each
additional probe reduces every probe’s sensitivity and the distance it is able to detect. The Drive-Alert will not know which sensing probe
detects a vehicle. If you wish to use “Zoning” with different alerts for different areas, consider a Mier DA-100 or DA-700 Drive-Alert
System.
* *

3
Installation page 2 of 2
Keep the probe, cable, and control panel at least 8 feet away from heavy power lines, power
panels, motors, arcing or sparking machinery, and radio transmitters. In some cases, moving the
panel and/or cable a few feet can solve interference problems. FIGURE 1 illustrates the contacts on
the bottom of the DA-500 Control Panel, with the sensor correctly attached.
When more than 1 probe is used, wire the units in parallel at the terminals on the DA-500 control
panel. DO NOT CUT/SPLICE the cables: doing so may allow moisture from entering the cable and
causing problems such as false alarms. (See FIGURE 2) The sensing probe is a 1x12 inches
cylinder containing a sealed sensor.
Be cautious when handling the
sensor and particularly careful to not
nick the cable attached to it.
Bury the probe at least 6 inches deep.
A typical installation is the probe 6
inches deep parallel to drive, which
will allow the probe to “sense” 12
feet across the driveway.
The ideal installation allows you
to extend your detection range by
installing the sensor under the center
of drive.
12’12’
12’12’
12’12’
RED WIRE
BLACK
SENSOR
SHEILD WIRE
FIGURE 1
One Probe attached
SENSOR
SENSOR
SENSOR
FIGURE 2
Multiple Probes attached

4
Operation and Adjustment Instructions
The Drive-Alert is adjusted at the factory for maximum sensitivity for the probe and minimum time for the whistle. To adjust these, open the
control panel and adjust the small pots according to the diagram on the inside cover (see FIGURE 2). The whistle “timer adjust” is
adjustable from 1-12 seconds and the LED 3 will light.
When rst plugged in, the red blanker LED 2 will remain on for only 1 minute, and the Drive-Alert will be muted for approximately 1
minute each time the electrical power is turned on. It provides time for the electronic circuits to initialize.
During normal operation, the noise blanker detects unwanted electrical interference and mutes the Drive-Alert for a few seconds. It has
been adjusted at the factory. The blanker light should be off during normal operation.
To test the Control Panel, it is possible to rub your nger simultaneously on the three terminals to which the sensing probe is attached. This
should cause the system to go into false alarm. This will occur with or without the sensing probe attached. Be sure the terminal screws are
tight while making the test. If the system responds to this test, in almost all instances it indicates a properly functioning control panel.
If false alarms occur, remove the sensing probe wires fron the Drive-Alert terminals. Let the power remain turned on to the control panel.
If the false alarm stops, then the most likely cause of the problem is moisture in the sensing probe cable. Radio transmitters, cell phones,
cordless phones, and wireless modems within 10 feet of the control panel may cause false alarms.
Additional devices can be attached to the Drive-Alert on its terminals at the bottom of the control panel. When the whistle switch is turned
off, the Drive-Alert terminals can switch customer provided electrical current up to 5 AMPS. Never attach any device that puts more than 30
volts DC on the Drive-Alert terminals. When the whistle switch is turned on, the Drive-Alert terminals have available 24 VDC at 100 MA.
Refer to the diagrams in this manual for hookup instructions.
Mier Products has a hard-wired “timer control” accessory available. The DA-505 Timer Control attaches to the Drive-Alert terminals. This
Timer Control is adjustable from 45 seconds to 45 minutes. It switches up to one thousand watts of 115 volt power for outside lights. Mier
Products also has a hard-wired chime available. The DA-655 Chime with Volume Control is the most popular accessory for the DA-500,
and is highly recommended for drive-up window or business applications. Mier also has a wireless “timer control” kit (DA-606LK) which
adjusts from 45 seconds to 45 minutes and includes a DA-071 Light Switch and DA-072 Lamp Module to control lights as an alert in addi-
tion to the audible alert. Furthermore, Mier has a chime transmitter (DA-066MP) which triggers wireless DA-078 Wireless Plug-in Chimes.
NOTE: When using multiple accessories, add a DA-500LKA which provides additional relay contacts to a DA-500.
Along with Mier’s accessories, the DA-500 can also trigger your other devices such as surveillance, bells,
sirens, signs, gates, and much more!
FIGURE 2
DA-500 CONTROL PANEL ADJUSTMENTS
BLANKER ADJUST
BLANKER
LED 2
TIMER ADJUST
MAX MIN
SENSITIVITY
MAXMIN
LED 3 ALARM
1 AMP FUSE
RELAY
POWER
LED 1
MAXIMUM CONTACT CURRENT IS 100 MILLIAMP AT
24 V WHEN USING DRIVE-ALERT VOLTAGE SUPPLY
SENSOR RELAY
DO NOT CONNECT TO 120V AC

5
DA-500 Connecting External Hard-Wired DA-655 Chime
DA-500 with whistle ON
RED BLACK SHLD NEG +24DC NO NC C
UN REG
1 2 3 4 5 6 7 8
Green
Black Red
Sensor DA-655
DA-500 with whistle OFF
RED BLACK SHLD NEG +24DC NO NC C
UN REG
1 2 3 4 5 6 7 8
Jumper
Green
Black Red
Sensor DA-655
C
DA-500 Connecting a DA-REPEATER Long-Range Chime Transmitter for DA-100CPs
Sensor Wires:
Red to #1
Black to #2
Silver Shield to #3
DA-REPEATER DA-100CP
1 2 3 4 5 6 7 8
SENSOR
DA-500 Connecting DA-066MP Wireless Chime Transmitter for DA-078s
Sensor Wires:
Red to #1
Black to #2
Silver Shield to #3
DA-066MP
DA-078
Black to #4 NEG/Ground
Red to #5 +24 Volt DC
White to #6, NO
C
C
Jumper from NEG/GND to C
DA-500 Whistle Switch
MUST be OFF 1 2 3 4 5 6 7 8
SENSOR
Note: up to three (3)
DA-655s can be used
with a maximum of fty
(50) feet of wire)
Note: If you only want
the chime as an alert,
but do not want the
internal whistle, you
must turn the whistle
swtich OFF, and use a
jumper on the control
panel (see illustration)

6
DA-500 and
Remote Hard-Wired DA-505 Timer Control Connection for Hard-Wired Lights
DA-500 and
Remote Wireless DA-606 Timer Control Connection for Wireless Lights
Green to #6 NO, normally open
Black to #4 NEG/Ground
Sensor Wires:
Red to #1
Black to #2
Silver Shiield to #3
Red to #5 +24 Volt DC
Black 16 gauge wire
120V Source (10amps max)
Black wires to lights
Internal Relay
Contact
1 2 3 4 5 6 7 8
SENSOR
DA-500 Whistle Switch
MUST be ON
Black Outer Cable Jacket
Sensor Wires:
Red to #1
Black to #2
Silver Shiield to #3
DA-606
DA-500 with whistle ON
If using with a DA-500LKA
RED BLACK SHLD NEG +24DC NO NC C
UN REG
NO C NO NC C
DA-500LKA
Black Red
1 2 3 4 5 6 7 8
SENSOR
When the DA-500 Whistle
Switch is OFF

7
DA-500 and Connection Using Dry Contacts and External Power
DA-500 and Connecting a DA-500LKA for Additional Contacts
DA-500 and Connecting the DA-052 Whistle, Bells or DA-091 Power Horns
1 2 3 4 5 6 7 8
SENSOR RELAY
BELL
DA-500 Whistle Switch
MUST be OFF
External Power
Capacitor
0.1 Microfarads 100 Volt (min)
Maximum current linited to 1 AMPERE
Maximum Voltage - 24 VOLTS (DO NOT apply 120VAC to terminals)
Sensor Wires:
Red to #1
Black to #2
Silver Shiield to #3
NOTE: Keep the DA-500 Whistle Switch on. However, if internal piezo whistle is not wanted, move the DA-500 Whistle Switch to the
OFF position and connect the jumper between +24 and the C Terminal
External 24VDC Whistle, Bell or Horn
with the DA-500 Whistle Switch ON
Black Outer Cable Jacket
Sensor Wires:
Red to #1
Black to #2
Silver Shiield to #3
BELL
or
1N4004 DIODE/Capacitor 0.1 Microfarads 100 Volt (min)
Adding a capacitor extends the life of the relay.
DA-052
Note: Limit of two (2) Bells.
Limit of two (2) DA-091 Power Horns.
Limit of ve (5) DA-052 Whistles
External Relay Hookup
24VDC
To AC operated
CHIMES/ALARMS
1 2 3 4 5 6 7 8
SENSOR RELAY
Sensor Wires:
Red to #1
Black to #2
Silver Shield to #3
DA-500LKA
Red to #6, NO, Normally Open
Black to #4 NEG/Ground
DA-500 Whistle Switch
MUST be ON 1 2 3 4 5 6 7 8
SENSOR

8
WIRELESS DRIVE-ALERT ACCESSORIES:
DA-066MP DA-078 DA-100CP DA-REPEATER DA-606 DA-071 DA-072 DA-073 DA-ROCK1
• The DA-066MP Remote Chime Transmitter is used in combination with the wireless DA-078 Remote Plug-in Chime(s) in applications where
more chimes are wanted in more rooms/areas. Unlimited quantities may be used.
• The DA-100CP Long Distance Remote Chime is actually a self-contained Control Panel/Receiver that receives a signal from up to 1000 feet
of any of Mier’s wireless Sensor/Transmitters, or a DA-REPEATER, and provides a pleasant tone as an alert. It also includes volume control.
• The DA-REPEATER can be attached to a DA-700 or DA-500 Control Panel/Receiver and repeats the signal to other wireless Control Panel/
Receivers (DA-100CP, DA-700CP) up to 1000 feet away, or up to 3/4-mile with the use of a DA-660 Antenna (see previous page).
• The DA-606LK Wireless Light Kit comes with a DA-606 Timer Control, one DA-071 Light-Switch, and one DA-072 Lamp Module. Any
number and combination of light-switches and lamp modules may be used. For heavy-duty applications the DA-073 Heavy-Duty Outlet
includes a top receptacle that handles up to a maximum of 1800 watts or maximum of 15 amps.
• The DA-ROCK1 is a popular accessory with all of our wireless systems, and is used to hide the DA-610 Sensor
HARD-WIRED DRIVE-ALERT ACCESSORIES:
DA-655 DA-500LKA DA-052V DA-505 DA-505W DA-050
• The Hard-Wired DA-655 Chime with Volume Control is our most popular accessory for the model DA-500 Drive-Alert in Drive-up Window
or business applications!
• The DA-500LKA is a set of Form C Dry Contacts that can be attached to the DA-700 or DA-500 Control Panels.
• The DA-052V Whistle with Volume Control – is used with the DA-700 when a second whistle is desired (hard-wired installation)
• The Hard-Wired DA-505 Timer Control will turn on 10 amps of lights, sirens or bells from 1-45 minutes. The DA-505 unit simply plugs into a
120 VAC outlet and contains its own receptacle to provide power to lights or alarms.
• The Hard-Wired DA-505 Timer Control will turn on lights, sirens or bells from 1-45 minutes. The DA-505W is a “stand alone” unit that gets
its power from the Drive-Alert, and provides a N.O., timed, dry contact to switch a load (lights, contactors, bells, etc) rated at 10 amps, 120
volts AC. The DA-505W is a terric intermediate interface with a “healthy” large relay within, that may be used to control other functions
such as triggering a large commercial lighting contactor, billboards, holiday lights, etc.
• The DA-050 Power Pack is a replacement power-pack/transformer for the Drive-Alerts.
If your Drive-Alert accessories do not look like these, you may have older models. Please call Mier’s free tech support line at 800-473-0213
Accessories

9
DA-500 Drive-Alert Frequently Asked Questions
Q: How many Sensor/Transmitters can be used?
A: Three hard-cabled sensors. However there is no way to discriminate which Sensor/Transmitter is causing the alert to sound.
Q: How many sound devices can be used?
A: See the following list and quantities supported:
•DA-063 8 inch Bell QTY 2
•DA-052V Hard-Wired Remote Whistle QTY 5
•DA-078 Wireless Plug-InChime QTY Unlimited
•DA-071 Wireless Light Switch QTY Unlimited
•DA-072 Wireless Lamp Module QTY Unlimited
•DA-655 Wired Chime QTY 3, with a maximum of 50 feet of wire
•Miscellaneous Sounder QTY # That adds to 100mA(max) load
Q: Does the unit have the capability when it determines an alarm is to be sounded, to trigger another device.
A: Each unit DOES have this capability as the 3 contacts from the alarm relay are available for use at the Terminal Block (Terminals 6-8). In models
that DO have an internal Whistle and corresponding switch these contacts normally switch +24 Volts but can become Form C dry contacts when
the Whistle Switch is in the OFF position. In those models that DO NOT have an internal Whistle, and corresponding switch, these contacts will
always be switching +24 Volts.
Q: Can a camera be activated by the Drive Alert.
A; Yes, by using the Form C dry contact mode or by buffering with an external relay in the non-dry contact mode.
Q: Can a gate be activated by the Drive Alert.
A: Yes, by using the Form C dry contact mode or by buffering with an external relay in the non-dry contact mode but safety care should be taken
for the event a person or vehicle in the gate’s path.
Q: Can vehicles be counted using the Drive Alert.
A: Yes, by using the Form C dry contact mode or by buffering with an external relay in the non-dry contact mode.
Q: Can the Drive Alert provide a contact closure for detection to open/lift an arm and then close it when the vehicle has cleared the area.
A: No, it does not provide intelligence beyond the simple sensing that the magnetic eld has been disturbed. Once disturbed a closure occurs for
a user dened time up to 12 seconds at which time the gate or arm will then return to its home position. For these types of functions external logic
and timing is required.
Q: Can the Drive Alert sense which way the vehicle is traveling?
A: No, it does not include this capability and would require either external methods or the use of two systems and most likely external logic to
sequence the two systems for this determination.
Q: How can I determine if something NOT a magnetic metal is moving?
A: Within the range of the sensor, attach a magnet or a metal that has magnetic characteristics such as steel. Now whenever it moves the sensor
senses it, transmits to the Receiver/Control Panel and the alarm is set off.
Q: Does the Drive Alert sense people?
A: No, it doesn’t sense people or animals, only changes that result in a magnetic eld disturbance. IF detecting people or animals is needed with a
Drive Alert, then a magnet or signicant magnetic metal must be on the person/animal.

10
DA-500 Drive-Alert Troubleshooting Tree
Step 1 - Check to make sure the Power Light is on. If not, replace the internal 1A fuse, or send to Mier Products for repair.
Step 2 - Make sure the sensor is attached correctly and securely to the control panel.
Step 3 - Make sure the sensor is located close enough to detect moving vehicles.
Step 4 - Make sure the sensor is at least 20 feet away from underground or overhead power/phone lines or an invisible fence, and the control panel
is at least 15 feet away from cellular or cordless phones, wireless routers, etc.
Step 5 - Make sure the sensor is at least 50 feet away from the street/road trafc to prevent false alarms.
Step 6 - Make sure there are no nicks or cuts in the cable allowing moisture to get inside and cause false alarms.
False Alarms No Detection or
Intermittent Detection
Check sensor to
make sure it’s
secure and placed
20’ away from Main
Power/phone lines
Check panel is 15’
from cell phones,
cordless phones,
routers, etc.
Check sensor is 50’
away from street
Call Mier Products’
Free Tech Support.
They will work with
you and might
recommend
returning the system
to Mier Products for
diagnosis and
repair.
Correct as
neded
Check sensor wire
connections at panel
for no shorting &
correct attachment
(Red=T1, Black=T2,
Ground = T3)
ExistingNew
Fix
Not xed
Not xed
Not xed
Still not xed
ExistingNew
Check for two-way
radio interaction
Not xed
Secure,
increase
distance, or
cross lines at
right angles
Fix
Increase
distances
Fix
Increase
distance or
reduce
sensitivity
Fix
Install on
cable RF
Cable Clamp
(Radio Shack
#273-105 or
eq.)
Fix
Remove all sensor
wires from terminal
block and see if
panel is “quiet.”
Remove all
accessory wires
from terminal block
and see if panel is
“quiet”
Replace
Sensor &
Cable
Remove Shield
(bare) wire from
terminal 3 of terminal
block and retry
Fix
Not xed
Not xed
Not xed
Replace
Accesso-
ries
Fix
Fix
Call Mier Products’
Free Tech Support.
They will work with
you and might
recommend
returning the system
to Mier Products for
diagnosis and
repair.
Check sensor
resistance at 900-
1100 OHMS Red to
Black
Check sensor wire
connections at panel
for no shorting &
correct attachment
(Red=T1, Black=T2,
Ground = T3)
Check Blanker LED
located on circuit
board is OFF, and if
not turn fully
counter-clockwise
Check sensor
placment 1 foot max
away from edge of
driveway and 1 foot
max deep in ground.
Not xed
Not xed
Not xed
Check panel
sensitivity at MAX
and do nger test
across BK and S
terminals
Not xed
Replace
Sensor &
Cable
Call Mier Products’
Free Tech Support.
They will work with
you and might
recommend
returning the system
to Mier Products for
diagnosis and
repair.
Still not xed
Place two ngers
across BK and S
terminals
Relay Clicked but there
was no Whistle
Call Mier
Tech
Support
Check Blanker LED
is OFF and if not
turn fully counter-
clockwise No Relay
Click or
Whistle
Not xed
Not xed
Replace
Sensor
and cable
Fix
Check sensor
resistance at 900-
1100 OHMS Red to
Black
Flip Whistle-Switch
25 times and try
again.
Call Mier
Tech
Support
Relay
Clicks but
no Whistle
Call Mier Products’
Free Tech Support.
They will work with
you and might
recommend
returning the system
to Mier Products for
diagnosis and
repair.
Still not xed
DA-500 Specications
• Input -- 120 VAC, 50-60Hz, 3.6 Watts
• Output -- 24 VDC at 100 Milliamps
• Surge protected from transients
• Adjustable sensor sensitivity
• Adjustable time control for electronic whistle
• Operating temperature -- 20 degree F to 160 degree F
• Provisions for activating optional timer control
• Weight -- six (6) pounds

11
Mier Products’ Drive-Alert Warranty
Limited Warranty for Drive-Alert Models and Accessories Manufactured by Mier Products, Inc.
Mier Products, Inc.’s Limited Warranty Program for Drive-Alert Series of Vehicle Detection Systems and Drive-Alert Accessories protects the
original owner for one year from the date of purchase against defects in original parts or workmanship. Mier Products, Inc. agrees to repair or
replace parts (Mier’s option) that are deemed defective by our Quality Control Team, without charge for parts or labor, if the defective unit is
returned prepaid to Mier Products, Inc., Kokomo, IN, within the one-year period.
Close inspection and testing, at the time of receipt by the customer, will quickly determine product quality. Thus, Mier Products, Inc. recommends
inspection of, and testing, the Drive-Alert models, direct burial cable, and accessories immediately upon receipt, before installation or driving to
an installation site, and contacting Mier Products, Inc. if quality issues arise.
NOTE: Sensors and cables that have been buried are not covered. Wireless sensors that have been sitting in ooded areas or standing water
are not covered.
Mier Products, Inc. does not assume responsibility for claims or damages caused by improper installation or use of these products, accessories,
and/or products connected to or stored within them. Mier Products, Inc. does not assume responsibility for damages to these products or their
accessories due to shipping damage or damage occurring while in a customer’s warehouse and/or possession. Mier Products, Inc. does not
assume responsibility for damage due to accident, faulty wiring, overload of Drive-Alert System or Drive-Alert accessory output, or components
attached to the Drive-Alert parts. Drive-Alert models and accessories must be shipped, handled, stored, and installed with strict adherence to
OEM installation instructions.
Drive-Alert accessories and parts built by other OEMs (including but not limited to chimes, lamp modules, light switches, bells, splice kits) are
covered under their respective OEM warranties.
This warranty constitutes the entire warranty with respect to Mier’s Drive-Alert Models and Accessories and IS IN LIEU OF ALL OTHERS,
EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OR MERCHANTABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE AND IN NO EVENT IS MIER PRODUCTS, INC., OR IT’S DISTRIBUTOR, DEALER, OR OEM PARTNERS, RESPONSIBLE FOR ANY
CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER.
Any warranty OR sales questions should be directed to Mier Products at 800-473-0213, or via e-mail to [email protected]
Any repair work not covered by this Warranty is available for a nominal charge.
Products which customers wish to return for reasons other than Warranty must rst call Mier Products, Inc. to receive a Return Material
Authorization Number (RMA#). Returns are subject to a 15% re-stocking fee as well as return shipping. NOTE: Special Order products, such as
Mier’s Temperature Controlled Enclosure line, are non-cancellable and non-returnable.
Mier Products, Inc. provides free telephone and email lifetime technical support for all of our Drive-Alert vehicle detection systems. Call us
between the hours of 8:00 am and 5:00 pm EST, send an email, or download our Cut-Sheets, Instruction Manuals, or FAQs from our website.
Mier Products’ Drive-Alert Technical Support