Soyal AR-727H User manual

SOYAL
ACCESS CONTROL SYSTEM
®AR-327 (H) / AR-727 (H) V140423
A. B.
A. B.
P1
P1
P2
P2
P3
P3
P4
P4
P1
P2
P3
P4
3
1
2
5
4
3
1
2
4
5
P1
P2
P3
P4
Contents
AR-327(H):Touch-panel Metal Case
AR-727 (H)
2User Guide
2User Guide
Installation
AR-327 (H)
AR-327 (H)
Pull the cables from the square hole of the mounting plate.
Use a screw to the mounting plate onto the wall.
Attach the water proof strip to the body, then connect the terminal cables
to the body and attach the body to the mounting plate.
Use the Allen key and screws (accessories supplied) to assemble the
body onto the mounting plate.
Turn on the power, the LED will light and hear the beep sound, you will
see "Ready"" on LCD board.
The communication wires and power line should NOT be bound in the same conduit or tubing.
Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the
reader malfunction.
The standard installation: Lock relay and lock use the same power supply, and reader use independent power supply.
Use AWG 22-24 Shielded Twist Pair it sould avoid star wiring.
1.Tubing:
2.Wire selection:
3.Power supply:
4.F4: At rst time use, if appears no screen and green LED ashes, please press [F4] for 2 seconds.
Attach the water proof strip to the mounting plate.
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the
mounting plate.
Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power, the LED will light and hear the beep sound, you will see
"Ready"" on LCD board.
AR-727 (H)
AR-727 (H)
1Products
1Products
3Terminal Cables
3Terminal Cables
4Tools
4Tools
5Water proof Strip
5Water proof Strip
Notice
AR-327(H) 13.56MHz Notice
Connector Table
Wire Application
Door Relay
Common-COM-Point
Door contact
Exit Switch
Alarm Relay
Power
Wire Application
Tamper Switch
Wire Application
Networking
Wiegand
Buzzer
LED
Wire Application
Arming Setting Input
Serial Port
Arming Status
indication (light)
Card existing indication
Description
(N.O.)DC24V1Amp
(N.C.)DC24V1Amp
(COM)DC24V1Amp
Negative Trigger Input
Negative Trigger Input
N.O./N.C. Options
(by jumper)
DC 12V
DC 0V
Description
N.C.
COM
N.O.
Description
RS-485 (B-)
RS-485 (A+)
WG DAT: 1 Inpu
ABA Data Input
WG DAT: 0 Input
ABA Clock Input
Buzzer Output 5V/100mA, MAX
LED Green Output 5V/20mA, MAX
LED Red Output 5V/20mA, MAX
Description
Latch type
Serial output (Transistor open
collector) (4800, N,8,1)
Arming output (Active low)/
Security trigger signal Output
Output LOW when card present
Color
Blue White
Purple White
White
Orange
Purple
Gray
Thick Red
Thick Black
Color
Red
Orange
Yellow
Color
Thick Green
Thick Blue
Blue
Green
Pink
Brown
Yellow
Color
Orange White
Yellow White
Red White
Brown White
Pin
1
2
3
4
5
6
7
8
Pin
1
2
3
Pin
1
2
3
4
5
6
7
Pin
1
2
3
4
P1Cable:
Cable:
Cable:
Cable:
P3
P2
P4
Sensing range of metal controller is small, the
proposed sensing card should step aside, do
not fully cover number keys.
V140423
12V
GND
WG 1
WG 0
BZ
GLED
RLED
12V
GND
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
WG 1
WG 0
BZ
GLED
RLED
GND
12V
12V
GND
P2 P1
B-
A+
B-
A+
B-
A+
Host
CH1
CH2
1
2
3
4
5
6
7
1
2
3
4
5
6
7
B-
A+
Host
GND
12V
A+
B-
B-
A+
B-
A+
P2 P2
EXIT
1
2
3
4
5
6
7
8
12V
GND
12V
GND
12V
GND
N.O.
N.O.
N.C.
COM
PB
12V
GND
P1
EXIT
1
2
3
4
5
6
7
8
12V
GND
12V
GND
12V
GND
N.O.
N.C.
N.O.
COM
PB
12V
GND
P1
1
2
3
4
5
6
7
8
COM
Door contact
ALM
12V
GND
12V
GND
12V
GND
12V
GND
P1
EXIT
1
2
3
4
5
6
7
8
4 3 2 1
N.C.
N.O.
COM
CTL
12V
GND
PB
P1
P4
12V
GND
ARM
LCD Access Controller
Metal Case / Standard
AR-327 (H) AR-727 (H)
Connect to Electric Bolt or Magnet Lock
Electric Bolt
Electric Bolt
Magnetic Lock
Controller
※ Security trigger signal: Please refer to the "Operation".
Controller
Connect to strengthen security with AR-721RB
Connect to Reader
Electric Strike
Alarm
Controller
ControllerReader
Controller
AR-716E
AR-716E
Converter
Node ID 001
Node ID 254
Door No. 1
Door No. 9
Door No. 8
Door No. 16
Request To ExitRequest To Exit
Request To Exit
Door Contact
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Connect to Door Contact
Controller
Controller
Controller
Controller
POWER
12VDC
Connect to Networking
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Connect to Electric Strike
Wiring Diagram
Front Panel & Indicator
18/02 FRI Duty:0 18/02 FRI Duty:0
10:49:34 10:49:34
Ready...... Ready......
Data
Week
Work Status
Data
Week
Work Shift Status
Arming Setting Input
Indicator (Green)
Card Present (Green)
Error OK
Arming Setting Input Indicator (Red)
Card Present (Green)
Operate Correct/Stand-by(Green)
Operate Error (Red)
Arming (Green)
Alarm (Red)
Host Receive (Green)
Host Transmit (Red)
Esc/Quit
Up
Down
Left
Right
Enter/OK
Arming(Green)
Alarm(Red)
RX TX
Esc/Quit
Up
Down
Left
Right
Enter/OK
F1
F2
F3
F4
Press 1 time
Duty on
Duty off
Overtime on
Overtime off
Press 2 time
Break out
Break RTN
Out
Return
Attendance
SOYAL
ACCESS CONTROL SYSTEM
®AR-327 (H) / AR-727 (H) V140423
A 18/02 15:45:25
FRI 00001 001
B. Enter/Escape Program Mode
C. Initial Setup
D. Security Trigger Signal
Enter program mode
Input 123456 or PPPPPP (PPPPPP= modied Master Code; Default= 123456)
[e.g.] If the Master Code= 876112, input 876112 → Enter program mode
※ If without any operation for 30 seconds access controller will escape program mode.
Escape program mode
Press continuously → Quit
6
6 8
8
[e.g.] AR-327H is the 8th slave reader under the 16th AR-716E.
Door-H input (door NO. of controller); Door-L input (door No. of the reader).
[e.g.] AR-727H is a controller and its Node ID is 8.
Door-H input ; Door-L input
1
8
Changing the Node ID of Reader
Enter program mode → Parameters[1] → Node ID → Input New Node ID:1~254(default value: 001)
→ Input: 1~4 to Show Card ID format? (1.No, 2.WG, 3.ABA, 4.HEX) → Input Door number H: 1~254(door
No. of its controllen) → Input Door number L: 1~254(door No. of reader) → Succeeded
3 1
Work Status Code
Date
Time
Serial NO.
User Add.
Week
A: Duty On
B: Duty Off
C: Overtime On
D: Overtime Off
E: Break Out
F: Break RTN
G: Out
H: Return
01: PWD/PIN Error
03: Invalid Card
04: Time-zone Error
11: Normal Access
16: Egress (Request to exit)
17: Alarm
31: Anti-pass back Error
Work Status Code:
Changing the Master Code
Enter program mode → Tools → Master Code → Input the 6-digit new master code → Succeeded
5 2
Restoring Factory Settings
Enter program mode → Parameters[2] → Factory Reset → select [1: Yes] → Succeeded...
4 9
Enable the Security Trigger signal
Enter program mode → Parameters[1] → Arming Pulse → Input [10](default value:1000) → become the Security Trigger signal Output
※ If Request To Exit connect to [AR-721RB], the Request To Exit can control the lock immediate.
3 9
Review the old events
Enter program mode → Tools → View Events → the display will show the history events.
5 0
Changing the Language
Enter program mode → Tools → Language → EN → Succeeded...
5 1 1
Adding and Deleting Card
Operation
A. Keyboard Lock/ Unlock
Lock/ Unlock
Hold down and buttons in simultaneously to lock/unlock the keyboard.
Mode4/Mode8
1
Enter program mode → Add/Delete → Add Card > ID → Input 5-digit user address → Input Site Code → Input Card Code
1
Adding Card by Card ID
1 5
Enter program mode → Add/Delete → Delete > Address → Input Start address → Input End address
Deleteing User Address
2 1
Enter program mode → User Setting → Password → Input 5-digit user address → Key in 4-digit PIN
Setting up the password
2 2
Enter program mode → User Setting → Access Mode → Input 5-digit user address → 1: Card; 2: or PIN; 3: & PIN; 4: Pause;
Setting up the access mode
Mode6
※In Mode6, user address is card code. Only suspend or recover to add or delete the cards.
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
1 2
Enter program mode → Add/Delete → Add > RF Learn → Input 5-digit user address →
Input Tag Units(pcs) → Close Tag into RF Area to induct.
Adding Card RF Induction
※For block Sequential cards, present the lowest card code card to the controller reader; for block
random cards, present all the cards one by one to the controller reader.
71
Enter program mode → Add/Delete → Recover > Address → Input Start address → Input End address
Adding Card
※For block Sequential cards, input the lowest card code as starting user address and input the hightest card code as ending user address; for block
random cards, input all the card codes one by one to the controller reader.
1 3
3 8
Enter program mode → Parameters[1] → Arming PWD → Input: 0000
Card Only
3 8
Enter program mode → Parameters[1] → Arming PWD → Key in 4-digit PIN [0001~9999, default value: 1234]
Card and PIN
4 8
Enter program mode → Parameters[2] → Duress Code → Key in 4-digit PIN [0001~9999, default value: 0000]
Card or PIN
Enter program mode → Add/Delete → Suspend > Address → Input Start address → Input End address
Deleting Card
※M6 access mode setting procedure is the same as the arming password/duress code setting procedure in M4.
※ First Update the Firware to 7v4_T2 later
V140423
LCD Access Controller
Metal Case / Standard
Enter program mode → Add/Delete → Antipass Group → Input Start address → Input End address → 1: Yes; 2: No;(select one)
1 9
Card set-up
Usually, anti-pass back is commonly applied to parking lots in order to prevent from multi-entry with one card, requires to set bith card and device
as the owings:
F. Anti-Pass Back(M4/M8 only)
Device set-up
Enter program mode → Parameters[2] → Anti-pass back → 1: Yes; 2: No;(select one) → 1: In; 2: Out;(select one)
4 7
G. Lift Control
Connect with AR-401RO16B to control which oors the user will be able to access.
Set Floor
1
0
17
0
9
0
25
0
1
2
3
0
19
0
11
0
27
0
2
0
18
0
10
0
26
0
4
0
20
0
12
0
28
0
5
0
21
0
13
0
29
0
6
0
22
0
14
0
30
0
7
0
23
0
15
0
31
0
8
1
24
0
16
1
32
0
Enter program mode → Tools → Termingal Port → 1
:
AR-401RO16
5 4
Setting Lift control
Enter program mode → User Setting → Single Floor → Input 5-digit user address → Input single oor number: 1~32
2 4
Single oor set-up
Enter program mode → User Setting → Single Floor → Input 5-digit user address → Select range: 1 or 2 → Input 16 digits multi oors
number [0:disable, 1: enable]
[e.g.] Set NO. 114, to access the 8th and the 16th oors.
Enter program mode → User Setting → Single Floor → 114 → 1 → 0000000100000001
2
2
5
5
Multi oors set-up
H.Arming Mode
Conditions:
1.Arming is enabled
2.Alarm system connected
Application:
1. Door left open warnings: these are generated when the door is held open for longer than the lock relay time and door
open time.
2. Force open (Unauthorized access alarms): these are generated when a door is opened without a valid card being
presented or a request to exit signal being received.
3. Door contact error: when the controller in arming status and power failure, reset power may activate alarm system.
Manu Tree
5. Tools
1. Language
2. Master Code
3. Master Range
4. Terminal Port
5. AR401RO16 Node
6. Open Time Zone
7. Information
8. Clock Setting
9. Control Mode
0. View Events
6. Quit
7. Quit & Arming
4. Parameters[2]
1. Auto Relock
2. Egress(R.T.E)
3. Attendance
4. Master Node
5. Force Open
6. Close & Stop
7. Anti-pass-back
8. Duress Code
9. Factory Reset
0. Key (#) is Bell
3. Parameters[1]
1. Node ID
2. Auto open Zone
3. Door Relay Tm
4. Door Close Tm
5. Alarm Relay Tm
6. Alarm Delay Tm
7. Arming Delay Tm
8. Arming PWD
9. Arming Pulse
0. Auto Alarm Tm
2. User Settings
1. Password
2. Access Mode
3.Extend Options
4. Single Floor
5.Multi Floor
1. Add/ Delete
1. Add Card >ID
2. Add > RF Learn
3. Suspend > Address
4. Suspend > ID #
5. Delete > Address
6. Delete > ID #
7. Recover > Address
8. Recover > ID #
9. Antipass Group
Enter program mode → Tools → Control Mode → 1:M4, 2:M6, 3:M8 (refer to following table) → Succeeded
5 9
E.Control Mode (M4/M6/M8)
※ The users up to 65,535 in Mode 6, since it reads CARD CODE(5 digits) only, unlike that Mode4/Mode8 read SITE CODE and CARD CODE(10 digits).
7Enter program mode → Quit
6
Enable/Disable Arming Mode:
Enable Arming Mode Disable Arming Mode
Program Mode
Door Open
Door Close
Access Mode → Input 4 digit arming code →
→ Input 4 digit arming code → Present the card to the controller reader → Input 4 digit arming code → Present the card to the controller reader
Access Mode → Input 4 digit arming code →
Enter program mode →Quit & Arming
Mode
Networking/
Standalone
Standalone
Networking/
Standalone
Networking/
Standalone
User
Capacity Access Mode
M4
M6
M8
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
32
No
32
11
No
11
Auto-show
Duty time
Event log
Capacity
120
Holidays
Anti
force
Time
Zone
Lift
Control
Anti-pass
back
1.Card only
2.Card and PIN (4-digit PIN)
3.Card or User address (5-digit) + Individual PIN
(4-digit individual PIN)
1.Card only
2.Card and PIN (4-digit public PIN= Arming PWD)
3.Card or PIN (4-digit public PIN= Duress code)
1.Card only
2.Card and PIN (4-digit individual PIN)
3.Card or PIN (4-digit individual PIN)
1,024(727H)
1,024(727H)
3,000(327H)
3,000(327H)
65,535
1,200(727H)
1,200(727H)
1,500(327H)
1,500(327H)
No
Điều Kiện Thương mại:
Sản phẩm mới 100% theo tiêu chuẩn của nhà sản xuất, cam kết chính hãng.
Quý khách vui lòng Liên hệ Vken để có báo giá chính xác của từng ngày.
Giao hàng trong vòng 02 ngày kể từ ngày ký kết hợp đồng hoặc xác nhận đơn đặt hàng.
Bảo hành theo tiêu chuẩn của nhà sản xuất.
Dịch vụ sau bán hàng:
Mọi chi tiết về thông số kỹ thuật của thiết bị, Quý khách vui lòng liên hệ tới VKEN :
0904 954 981
CATALOGUES
VKEN chúng tôi trân trọng gửi tới Quý Khách Hàng một số thông tin về sản phẩm do VKEN cung cấp, chúng tôi cam kết hàng bán
ra thị trường đều là chính hãng chất lượng cao. Rất mong nhận được sự hợp tác từ quý khách . Xin cảm ơn !
Kính chào Quý Khách Hàng !
VKEN xin cam kết với Quý Khách hàng trong thời hạn bảo hành thiết bị, công ty miễn phí bảo hành trong thời gian bảo hành . Trong
trường hợp thiết bị gặp sự cố, Vken sẽ nhánh chóng cử cán bộ kỹ thuật khắc phục trong vòng 02h kể từ khi nhận được thông báo
của Khách hàng !
Giới Thiệu về Vken : Vken Chuyên cung cấp: Các giải pháp an ninh giám sát, kiểm soát ra vào , quản lý nhân sự,hệ thống kiểm
soát ra vào tòa nhà.... cho các công trình, toà nhà, dự án lớn. VKEN Company luôn đảm bảo cung cấp đến khách hàng các sản
phẩm chính hãng với chất lượng tốt nhất, đáp ứng nền tảng công nghệ mới với giá cả phải chăng nhất.
Hotline:
CÔNG TY CỔ PHẦN THÀNH AN
Địa chỉ: Tầng 5 - Số 184 Nguyễn Tuân - Thanh Xuân- Hà nội Tel: 0904 954 981 Email: [email protected] MST: 0101219662 Website: www.Vken.vn

This manual suits for next models

3

Other Soyal Control Panel manuals

Soyal AR-716-E16 User manual

Soyal

Soyal AR-716-E16 User manual

Soyal AR-725 User manual

Soyal

Soyal AR-725 User manual

Soyal AR-716Ei User manual

Soyal

Soyal AR-716Ei User manual

Popular Control Panel manuals by other brands

Jung SP 9 KNX operating instructions

Jung

Jung SP 9 KNX operating instructions

Halma Ampac LoopSense Installation & commissioning

Halma

Halma Ampac LoopSense Installation & commissioning

Sentrol DIGI-KEY-IV-F owner's manual

Sentrol

Sentrol DIGI-KEY-IV-F owner's manual

Stahl 8220 Series operating instructions

Stahl

Stahl 8220 Series operating instructions

Ross Ultrix Acuity Operation manual

Ross

Ross Ultrix Acuity Operation manual

Siemens SINUMERIK 840D sl operating manual

Siemens

Siemens SINUMERIK 840D sl operating manual

DMP Electronics XR150FC Series System user's guide

DMP Electronics

DMP Electronics XR150FC Series System user's guide

Lofa CANplus CP600 Operation guide

Lofa

Lofa CANplus CP600 Operation guide

PS Engineering PMA7000H Pilot's Guide Pilot's Guide And Operation Manual Operation Manual

PS Engineering

PS Engineering PMA7000H Pilot's Guide Pilot's Guide And Operation Manual Operation Manual

Honeywell LT-32 Installation and user manual

Honeywell

Honeywell LT-32 Installation and user manual

meitav-tec PYROCON12 owner's manual

meitav-tec

meitav-tec PYROCON12 owner's manual

Arrowhead Alarm Products ESL-2 Installation & programming guide

Arrowhead Alarm Products

Arrowhead Alarm Products ESL-2 Installation & programming guide

Dea NET230N Operating instructions and warnings

Dea

Dea NET230N Operating instructions and warnings

Knight ILCS Edge Jr Programming manual

Knight

Knight ILCS Edge Jr Programming manual

Genesis Integrated Security System user manual

Genesis

Genesis Integrated Security System user manual

Johnson Controls FRICK QUANTUM LX/HD installation instructions

Johnson Controls

Johnson Controls FRICK QUANTUM LX/HD installation instructions

Serai CR/14 installation guide

Serai

Serai CR/14 installation guide

HEIDENHAIN TNC 640 user manual

HEIDENHAIN

HEIDENHAIN TNC 640 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.