SL SELECTION TABLE- 150W, 300W
150 Watt 300 Watt
kV mA Model mA Model
1 150 SL1PN150 300 SL1PN300
2 75 SL2PN150 150 SL2PN300
3 50 SL3PN150 100 SL3PN300
6 25 SL6PN150 50 SL6PN300
8 18.75 SL8PN150 37.5 SL8PN300
10 15 SL10*150 30 SL10*300
15 10 SL15*150 20 SL15*300
20 7.5 SL20*150 15 SL20*300
30 5.0 SL30*150 10 SL30*300
40 3.75 SL40*150 7.5 SL40*300
50 3.00 SL50*150 6.0 SL50*300
60 2.50 SL60*150 5.0 SL60*300
70 2.1 SL70*150 4.28 SL70*300
80 1.90 SL80*150 3.75 SL80*300
100 1.50 SL100*150 3.00 SL100*300
120 1.25 SL120*150 2.50 SL120*300
130 1.15 SL130*150 2.30 SL130*300
*Specify “P” for positive,
“N” for negative, or “PN”
for reversible polarity.
Higher voltage models
available on special order.
SL TERMINAL BLOCK 26 PIN
TB1 SIGNAL SIGNAL PARAMETERS
1 Power Supply Common Signal Ground
2 External Inhibit Ground=Inhibit, Open=HV On
3 External Interlock +15V at Open, <15mA at Closed
4 External Interlock Return Return for Interlock
5 Current Monitor 0 to 10V=0 to 100% Rated Output
6 kV Test Point 0 to 10V=0 to 100% Rated Output
7 +10Vdc Reference +10Vdc, 1mA Max
8 Remote Current Program In 0 to 10V=0 to 100% Rated Output
9 Local Current Program Out Front Panel Program Voltage
10 Remote Voltage Program In 0 to 10V=0 to 100% Rated Output
11 Local Voltage Program Out Front Panel Program Voltage
12 Power Monitor 0 to 10V=0 to 100% Rated Output
13 Remote Power Program In (Optional)
14 Local HV Off Out +15V at Open, <25mA at Closed
15 HV Off Comment to HV OFF for FP Operation
16 Remote HV On +15V, 10mA Max=HV Off
17 Remote HV Off Indicator 0=HV On, +15V, 10mA Max=HV Off
18 Remote HV On Indicator 0=HV Off, +15V, 10mA Max=HV On
19 Remote Voltage Mode
20 Remote Current Mode Open Collector 50V Max, 10mA Max
21 Remote Power Mode On=Active
22 Remote PS Fault 0=Fault, +15V, 0.1mA Max=No Fault
23 +15V Output +15V, 100mA Max
24 Power Supply Common Signal Ground
25 Spare Spare
26 Shield Return Chassis Ground
SL SELECTION TABLE- 600W, 1200W
600 Watt 1200 Watt
kV mA Model mA Model
1 600 SL1PN600 1200 SL1PN1200
2 300 SL2PN600 600 SL2PN1200
3 200 SL3PN600 400 SL3PN1200
6 100 SL6PN600 200 SL6PN1200
8 75 SL8PN600 150 SL8PN1200
10 60 SL10*600 120 SL10*1200
15 40 SL15*600 80 SL15*1200
20 30 SL20*600 60 SL20*1200
30 20 SL30*600 40 SL30*1200
40 15 SL40*600 30 SL40*1200
50 12 SL50*600 24 SL50*1200
60 10 SL60*600 20 SL60*1200
70 8.6 SL70*600 17 SL70*1200
80 7.5 SL80*600 15 SL80*1200
100 6.0 SL100*600 12 SL100*1200
120 5.0 SL120*600 10 SL120*1200
130 4.6 SL130*600 9.2 SL130*1200
*Specify “P” for positive,
“N” for negative, or “PN”
for reversible polarity.
Higher voltage models
available on special order.
PAGE 2 OF 4
*Specify “P” for positive, “N” for negative, or “PN” for reversible polarity.
Higher voltage models available on special order.
SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION
SL10W to 1200W
COMPACT HV POWER SUPPLY
SL SELECTION TABLE- 10W, 30W, 60W
10 Watt 30 Watt 60 Watt
kV mA Model mA Model mA Model
1 10 SL1PN10 30 SL1PN30 60 SL1PN60
2 5 SL2PN10 15 SL2PN30 30 SL2PN60
3 3.3 SL3PN10 10 SL3PN30 20 SL3PN60
6 1.7 SL6PN10 5 SL6PN30 10 SL6PN60
8 1.25 SL8PN10 3.75 SL8PN30 7.5 SL8PN60
10 1.0 SL10*10 3 SL10*30 6 SL10*60
15 0.67 SL15*10 2 SL15*30 4 SL15*60
20 0.50 SL20*10 1.5 SL20*30 3 SL20*60
30 0.33 SL30*10 1.0 SL30*30 2 SL30*60
40 0.25 SL40*10 0.75 SL40*30 1.5 SL40*60
50 0.20 SL50*10 0.60 SL50*30 1.2 SL50*60
60 0.17 SL60*10 0.50 SL60*30 1.0 SL60*60
70 0.14 SL70*10 0.43 SL70*30 0.85 SL70*60
80 0.13 SL80*10 0.38 SL80*30 0.75 SL80*60
100 0.10 SL100*10 0.30 SL100*30 0.60 SL100*60
120 0.10 SL120*10 0.25 SL120*30 0.50 SL120*60
130 0.10 SL130*10 0.25 SL130*30 0.46 SL130*60
1.75” (1U)
1.75” (1U)
3.50” (2U)
USA +1-631-630-3000 FAX: +1-631-435-1620
UK +44 (0)1798 877000 FAX: +44 (0)1798 872479
JAPAN +81 (0)48-447-6500 FAX: +81 (0)48-447-6501
CHINA +86 (0)512-67630010 FAX: +86 (0)512-67630030
e-mail: sales@spellmanhv.com
www.spellmanhv.com 128009-001 REV.T
Spellman High Voltage is an ISO 9001:2000 and ISO 14001:2004 registered company
How To Order:
Sample model number: SL80PN1200/NSS/DPM4
SL series unit, 80kV maximum output voltage,
reversible polarity output, 1200 watts, no slow start,
4.5 digit panel meters
There may be some restrictions on multiple option combinations.