Steam Traps
Universal
Connector and
Traps
466
UIB30 and UIB30H Sealed Inverted Bucket Steam Trap
(for use with Universal Connectors)
The trap contains an inverted bucket mechanism which responds to the
difference in density between steam and condensate. The discharge action
is cyclic. Condensate and non-condensibles are discharged close to steam
temperature. The UIB is designed to maintain the bucket in the proper plane
by means of a swivel connector. The trap is easily replaced without disturbing
the piping connections.
No. Part Material
1 Cover Stainless Steel ASTM A240 Gr 304
2 Body Stainless Steel ASTM A 351 CF8
3 Bucket Stainless Steel BS 1449 321 S 12
4 Valve Guide Plate Stainless Steel BS 1449 321 S 12
5 Valve Seat Stainless Steel AISI 440B
6 Valve Stainless Steel AISI 440B
7 Valve Lever Stainless Steel BS 1449 321 S 12
8 Internal Tube Stainless Steel BS 3605 304 S 14
9 Guide Stainless Steel BS 1449 304 S 16
10 Flange Alloy Steel ASTM A322 Gr 4130
12 Connector Screw Steel ASTM A 193 B7
13 Inlet Gasket Stainless Steel AISI 304 Strip
& Filler (Asbestos Free)
14 Outer Gasket Stainless Steel AISI 304 Strip
& Filler (Asbestos Free)
Note: The body/cover weld joint is to BS4870 (1981) and complies with ASME section IX.
Construction Materials
Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only.
In the interests of development and improvement of the product, we reserve the right to change the specification.
Typical Applications
Steam tracing, steam main drip stations, laundry equipment,
industrial dryers, and storage tanks.
Limiting Operating Conditions
Max. Operating Pressure UIB30/8 58 psig (4 barg)
(PMO) UIB30H/10 72 psig (5 barg)
UIB30/7 UIB30H/8 123 psig (8.5 barg)
UIB30/6 174 psig (12 barg)
UIB30/5 UIB30H/6 290 psig (20 barg)
UIB30/4 UIB30H/5 435 psig (30 barg)
Condensate kg/h
Differential Pressure bar
Capacities
TI-2-412-US 1.18
9
10
14
12
1,000
700
8 10 20 30 40
300
Condensate, lb/h
Differential Pressure, psi
600
500
400
300
100
UIB 30
60
800
UIB 30/8
900
200
UIB 30/7
UIB 30/6
UIB 30/5
UIB 30/4
58 80 200175125100 290 400
7
8
1
3
6
2
13
4
5
5 10 20 30
4
3
2
1
400
100
300
50
200
UIB 30H/10
/8
/5
/6
Envelope Pressure Range
400
300
200
100
0
0 145 290 435 580 725
Pressure psig
Pressure barg
0 10 20 30 40 50
Temperature °F
Temperature °C
752
572
392
206
32
Steam
saturation
curve
A
A
The product must not be used in this region.
*PMO Maximum operating pressure recommended.
A - A Flanged ANSI 300, screwed and socket weld
C - C Flanged ANSI 150
(Connector of choice sold separately)
See TI-2-519-US
Model UIB30, UIB30H
Trap
Construction Stainless Steel
Connector
Sizes ½”, ¾”, 1”
Connector
Connections NPT, SW
Connector
Construction
Straight or strainer type (left or right hand)
Stainless steel or cast steel
Connector
Options
SW connections to ANSI B16.11
Carbon steel
USTSII trap station
Steam Traps
Universal
Connector and
Traps
467
Dimensions (nominal) in inches and millimeters
Size A B C (UIB30) C (UB30H) D E Weight
1/2" 2.4 3.4 4.9 6.3 1.3 3.1 4.8 lb
61 86 125 160 34 80 2.19kg
3/4" 2.9 3.3 4.9 6.3 1.3 3.1 5.5 lb
74 84 125 160 34 80 2.22kg
1" 3.5 3.4 4.9 6.3 1.3 3.1 5.2 lb
90 87 125 160 34 80 2.38 kg
Spare Parts
Spirax Sarco, Inc., 1150 Northpoint Blvd, Blythewood, SC 29016 Telephone: (803) 714-2000 FAX (803) 714-2222
TI-2-412-US 1.18
Sample Specification
Steam trap shall be supplied with a pipe-
line connector which, once installed,
remains in the pipeline permanently. Trap
shall be attached to the connector by two
bolts to enable simple and rapid instal-
lation and replacement. The connection
is designed to allow installation on pipe-
work that is vertical, horizontal, or any
angle in between. The trap itself shall be
inverted bucket type of all-stainles steel
construction which resists distortion due
to freeze-up and waterhammer. Trap to
have a forged body and drawn cover fully
weld-sealed against leakage. Operation
shall be self-priming, with orifice size
selected for the capacity required by the
application, and suitable for working pres-
sures to 435 psig.
Installation
The connector can be installed in hori-
zontal or vertical lines. The connector
face must be in a vertical plane. The trap
should be fitted to the connector with the
body pointing downward. Full-port isolat-
ing valves should be installed upstream
and downstream of the connector.
Maintenance
The trap can be removed for repair or
replacement without disturbing the con-
nector piping connections. Complete iso-
lation of the connector from both the sup-
ply and return lines is required before the
trap is removed. Complete installation
and maintenance instructions are given
in the IMI sheet, which accompanies
the product.
A
Available spare parts are shown in
heavy outline. Parts drawn in broken
line are not supplied as spares.
Connector Screw
& Gasket Set A, B, C
Strainer Screen G
Blowdown Valve H
E
© Spirax Sarco, Inc. 2018
G
H
A
B
C
A
D
C
B
UIB30 and UIB30H Sealed Inverted Bucket Steam Trap
(for use with Universal Connectors)

Other manuals for UIB30

1

This manual suits for next models

1

Other Spirax Sarco Plumbing Product manuals

Spirax Sarco FT44 User manual

Spirax Sarco

Spirax Sarco FT44 User manual

Spirax Sarco FT Series User manual

Spirax Sarco

Spirax Sarco FT Series User manual

Spirax Sarco DT101F User manual

Spirax Sarco

Spirax Sarco DT101F User manual

Spirax Sarco FT 43 Series User manual

Spirax Sarco

Spirax Sarco FT 43 Series User manual

Spirax Sarco UIB30 User manual

Spirax Sarco

Spirax Sarco UIB30 User manual

Popular Plumbing Product manuals by other brands

Symmons Sereno Trim Series Installation & operation instructions

Symmons

Symmons Sereno Trim Series Installation & operation instructions

EdgeStar KC2000 Adjustment guide

EdgeStar

EdgeStar KC2000 Adjustment guide

BSP SF390 Installation, Maintenance & Operation Instructions

BSP

BSP SF390 Installation, Maintenance & Operation Instructions

Kohler K-2002 installation guide

Kohler

Kohler K-2002 installation guide

American Standard Renaissance RF Total Toilet 2444 installation instructions

American Standard

American Standard Renaissance RF Total Toilet 2444 installation instructions

American Standard Cadet 3 Elongated Toilet 2383.012 Specifications

American Standard

American Standard Cadet 3 Elongated Toilet 2383.012 Specifications

Hans Grohe Shower Select 15765000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Shower Select 15765000 Instructions for use/assembly instructions

Bossini OKI instruction manual

Bossini

Bossini OKI instruction manual

Moen WATERHILL TS516 Specifications

Moen

Moen WATERHILL TS516 Specifications

Hans Grohe Logis 71401 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Logis 71401 Series Instructions for use/assembly instructions

Sanela 01545 Instructions for use

Sanela

Sanela 01545 Instructions for use

Sanipex BAGNODESIGN BDS-ALP-485 Series installation guide

Sanipex

Sanipex BAGNODESIGN BDS-ALP-485 Series installation guide

Price Pfister Parisa 42 Series Instruction sheets

Price Pfister

Price Pfister Parisa 42 Series Instruction sheets

Galvin Specialised Ezy-Drink TD00L-RM Product installation guideline

Galvin Specialised

Galvin Specialised Ezy-Drink TD00L-RM Product installation guideline

FM Mattsson FMM 9000E Instruction

FM Mattsson

FM Mattsson FMM 9000E Instruction

Hugo Lahme FitStar X-Stream manual

Hugo Lahme

Hugo Lahme FitStar X-Stream manual

Lefroy Brooks M2-4302 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks M2-4302 Installation, operating, & maintenance instructions

Kohler K-18494 Homeowner's guide

Kohler

Kohler K-18494 Homeowner's guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.